Loading…
Dorsal Tangential View of the Wrist to Detect Screw Penetration to the Dorsal Cortex of the Distal Radius after Volar Fixed-Angle Plating
Background Extensor tendon irritation and attritional tendon ruptures are well-recognized complications, secondary to dorsal screw penetration following volar plating of the distal radius. Lateral and oblique views of the wrist have limited ability to detect such penetration, particularly at the uln...
Saved in:
Published in: | Hand (New York, N.Y.) N.Y.), 2011-06, Vol.6 (2), p.190-193 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c3962-776aeab93f97f9a75efd4832e3085d451592748219ddc53edd5c462eff16465e3 |
---|---|
cites | cdi_FETCH-LOGICAL-c3962-776aeab93f97f9a75efd4832e3085d451592748219ddc53edd5c462eff16465e3 |
container_end_page | 193 |
container_issue | 2 |
container_start_page | 190 |
container_title | Hand (New York, N.Y.) |
container_volume | 6 |
creator | Ozer, Kagan Toker, Serdar |
description | Background
Extensor tendon irritation and attritional tendon ruptures are well-recognized complications, secondary to dorsal screw penetration following volar plating of the distal radius. Lateral and oblique views of the wrist have limited ability to detect such penetration, particularly at the ulnar side of the Lister's tubercle. In this report, we conducted an intraoperative fluoroscopic study to determine dorsal screw penetration in various positions of the wrist/forearm and compared the standard radiographic views (lateral, supination, and pronation views) with dorsal tangential view of the wrist.
Materials and Method
Standard lateral, oblique (in pronation and supination), and dorsal tangential views were obtained in 27 consecutive patients undergoing fixation a distal radius fractures using a volar plate. The number of penetrating screws in each dorsal compartment (second, third, fourth) was recorded in each view. Dorsal tangential view was obtained using a mini C-arm intraoperatively and sending the beam parallel to the dorsal aspect of the wrist in transverse plane.
Results
Of the 125 distal screws, 8 screws were seen to be penetrating the dorsal cortex in lateral and oblique views, whereas 11 screws were detected in dorsal tangential view.
Conclusion
The screw penetration to the third dorsal compartment was missed in standard views, but visualized in dorsal tangential view. We recommend the use of dorsal tangential view in addition to standard lateral and oblique views during volar plating of the distal radius. |
doi_str_mv | 10.1007/s11552-010-9316-2 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3092900</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1007_s11552-010-9316-2</sage_id><sourcerecordid>1018344884</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3962-776aeab93f97f9a75efd4832e3085d451592748219ddc53edd5c462eff16465e3</originalsourceid><addsrcrecordid>eNqNkU1PFTEYhRujEUR-gBvTpZuBfs60GxNyLygJiUQRlk2Zvh1K5k6x7Sj-BP-1vbmXG90YV33Tc87Tj4PQG0qOKCHdcaZUStYQShrNaduwZ2i_7qhGCymf72bR7aFXOd8TIlql9Eu0x1grRUf4Pvq1jCnbEV_ZaYCphDpeB_iBo8flDvBNCrngEvESCvQFf-lTFS9hgpJsCXFaa2vjFrOIqcDjU3pZw3Xzs3Vhztj6Aglfx9EmfBYewTUn0zACvhwraRpeoxfejhkOt-sB-np2erX42Fx8-nC-OLloeq5b1nRda8Heau5157XtJHgnFGfAiZJOSCo164RiVDvXSw7OyV60DLynrWgl8AP0fsN9mG9X4Pr66mRH85DCyqafJtpg_lamcGeG-N1wopkmpALebQEpfpshF7MKuYdxtBPEORtKqOJCKCWqlW6sfYo5J_C7Yygx6wrNpkJTKzTrCg2rmbd_3m-XeOqsGtjGkKtUW0vmPs5pqn_2T-rRNmQH-J_Ab37Htmc</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1018344884</pqid></control><display><type>article</type><title>Dorsal Tangential View of the Wrist to Detect Screw Penetration to the Dorsal Cortex of the Distal Radius after Volar Fixed-Angle Plating</title><source>Open Access: PubMed Central</source><source>SAGE</source><creator>Ozer, Kagan ; Toker, Serdar</creator><creatorcontrib>Ozer, Kagan ; Toker, Serdar</creatorcontrib><description>Background
Extensor tendon irritation and attritional tendon ruptures are well-recognized complications, secondary to dorsal screw penetration following volar plating of the distal radius. Lateral and oblique views of the wrist have limited ability to detect such penetration, particularly at the ulnar side of the Lister's tubercle. In this report, we conducted an intraoperative fluoroscopic study to determine dorsal screw penetration in various positions of the wrist/forearm and compared the standard radiographic views (lateral, supination, and pronation views) with dorsal tangential view of the wrist.
Materials and Method
Standard lateral, oblique (in pronation and supination), and dorsal tangential views were obtained in 27 consecutive patients undergoing fixation a distal radius fractures using a volar plate. The number of penetrating screws in each dorsal compartment (second, third, fourth) was recorded in each view. Dorsal tangential view was obtained using a mini C-arm intraoperatively and sending the beam parallel to the dorsal aspect of the wrist in transverse plane.
Results
Of the 125 distal screws, 8 screws were seen to be penetrating the dorsal cortex in lateral and oblique views, whereas 11 screws were detected in dorsal tangential view.
Conclusion
The screw penetration to the third dorsal compartment was missed in standard views, but visualized in dorsal tangential view. We recommend the use of dorsal tangential view in addition to standard lateral and oblique views during volar plating of the distal radius.</description><identifier>ISSN: 1558-9447</identifier><identifier>EISSN: 1558-9455</identifier><identifier>DOI: 10.1007/s11552-010-9316-2</identifier><identifier>PMID: 22654703</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><subject>AAHS Meeting ; AAHS Meeting Article ; Medicine ; Medicine & Public Health ; Orthopedics ; Plastic Surgery ; Surgery ; Surgical Orthopedics</subject><ispartof>Hand (New York, N.Y.), 2011-06, Vol.6 (2), p.190-193</ispartof><rights>American Association for Hand Surgery 2011</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3962-776aeab93f97f9a75efd4832e3085d451592748219ddc53edd5c462eff16465e3</citedby><cites>FETCH-LOGICAL-c3962-776aeab93f97f9a75efd4832e3085d451592748219ddc53edd5c462eff16465e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3092900/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3092900/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793,79364</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/22654703$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ozer, Kagan</creatorcontrib><creatorcontrib>Toker, Serdar</creatorcontrib><title>Dorsal Tangential View of the Wrist to Detect Screw Penetration to the Dorsal Cortex of the Distal Radius after Volar Fixed-Angle Plating</title><title>Hand (New York, N.Y.)</title><addtitle>HAND</addtitle><addtitle>Hand (N Y)</addtitle><description>Background
Extensor tendon irritation and attritional tendon ruptures are well-recognized complications, secondary to dorsal screw penetration following volar plating of the distal radius. Lateral and oblique views of the wrist have limited ability to detect such penetration, particularly at the ulnar side of the Lister's tubercle. In this report, we conducted an intraoperative fluoroscopic study to determine dorsal screw penetration in various positions of the wrist/forearm and compared the standard radiographic views (lateral, supination, and pronation views) with dorsal tangential view of the wrist.
Materials and Method
Standard lateral, oblique (in pronation and supination), and dorsal tangential views were obtained in 27 consecutive patients undergoing fixation a distal radius fractures using a volar plate. The number of penetrating screws in each dorsal compartment (second, third, fourth) was recorded in each view. Dorsal tangential view was obtained using a mini C-arm intraoperatively and sending the beam parallel to the dorsal aspect of the wrist in transverse plane.
Results
Of the 125 distal screws, 8 screws were seen to be penetrating the dorsal cortex in lateral and oblique views, whereas 11 screws were detected in dorsal tangential view.
Conclusion
The screw penetration to the third dorsal compartment was missed in standard views, but visualized in dorsal tangential view. We recommend the use of dorsal tangential view in addition to standard lateral and oblique views during volar plating of the distal radius.</description><subject>AAHS Meeting</subject><subject>AAHS Meeting Article</subject><subject>Medicine</subject><subject>Medicine & Public Health</subject><subject>Orthopedics</subject><subject>Plastic Surgery</subject><subject>Surgery</subject><subject>Surgical Orthopedics</subject><issn>1558-9447</issn><issn>1558-9455</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNqNkU1PFTEYhRujEUR-gBvTpZuBfs60GxNyLygJiUQRlk2Zvh1K5k6x7Sj-BP-1vbmXG90YV33Tc87Tj4PQG0qOKCHdcaZUStYQShrNaduwZ2i_7qhGCymf72bR7aFXOd8TIlql9Eu0x1grRUf4Pvq1jCnbEV_ZaYCphDpeB_iBo8flDvBNCrngEvESCvQFf-lTFS9hgpJsCXFaa2vjFrOIqcDjU3pZw3Xzs3Vhztj6Aglfx9EmfBYewTUn0zACvhwraRpeoxfejhkOt-sB-np2erX42Fx8-nC-OLloeq5b1nRda8Heau5157XtJHgnFGfAiZJOSCo164RiVDvXSw7OyV60DLynrWgl8AP0fsN9mG9X4Pr66mRH85DCyqafJtpg_lamcGeG-N1wopkmpALebQEpfpshF7MKuYdxtBPEORtKqOJCKCWqlW6sfYo5J_C7Yygx6wrNpkJTKzTrCg2rmbd_3m-XeOqsGtjGkKtUW0vmPs5pqn_2T-rRNmQH-J_Ab37Htmc</recordid><startdate>201106</startdate><enddate>201106</enddate><creator>Ozer, Kagan</creator><creator>Toker, Serdar</creator><general>SAGE Publications</general><general>Springer-Verlag</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>201106</creationdate><title>Dorsal Tangential View of the Wrist to Detect Screw Penetration to the Dorsal Cortex of the Distal Radius after Volar Fixed-Angle Plating</title><author>Ozer, Kagan ; Toker, Serdar</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3962-776aeab93f97f9a75efd4832e3085d451592748219ddc53edd5c462eff16465e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>AAHS Meeting</topic><topic>AAHS Meeting Article</topic><topic>Medicine</topic><topic>Medicine & Public Health</topic><topic>Orthopedics</topic><topic>Plastic Surgery</topic><topic>Surgery</topic><topic>Surgical Orthopedics</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ozer, Kagan</creatorcontrib><creatorcontrib>Toker, Serdar</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Hand (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ozer, Kagan</au><au>Toker, Serdar</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Dorsal Tangential View of the Wrist to Detect Screw Penetration to the Dorsal Cortex of the Distal Radius after Volar Fixed-Angle Plating</atitle><jtitle>Hand (New York, N.Y.)</jtitle><stitle>HAND</stitle><addtitle>Hand (N Y)</addtitle><date>2011-06</date><risdate>2011</risdate><volume>6</volume><issue>2</issue><spage>190</spage><epage>193</epage><pages>190-193</pages><issn>1558-9447</issn><eissn>1558-9455</eissn><abstract>Background
Extensor tendon irritation and attritional tendon ruptures are well-recognized complications, secondary to dorsal screw penetration following volar plating of the distal radius. Lateral and oblique views of the wrist have limited ability to detect such penetration, particularly at the ulnar side of the Lister's tubercle. In this report, we conducted an intraoperative fluoroscopic study to determine dorsal screw penetration in various positions of the wrist/forearm and compared the standard radiographic views (lateral, supination, and pronation views) with dorsal tangential view of the wrist.
Materials and Method
Standard lateral, oblique (in pronation and supination), and dorsal tangential views were obtained in 27 consecutive patients undergoing fixation a distal radius fractures using a volar plate. The number of penetrating screws in each dorsal compartment (second, third, fourth) was recorded in each view. Dorsal tangential view was obtained using a mini C-arm intraoperatively and sending the beam parallel to the dorsal aspect of the wrist in transverse plane.
Results
Of the 125 distal screws, 8 screws were seen to be penetrating the dorsal cortex in lateral and oblique views, whereas 11 screws were detected in dorsal tangential view.
Conclusion
The screw penetration to the third dorsal compartment was missed in standard views, but visualized in dorsal tangential view. We recommend the use of dorsal tangential view in addition to standard lateral and oblique views during volar plating of the distal radius.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>22654703</pmid><doi>10.1007/s11552-010-9316-2</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1558-9447 |
ispartof | Hand (New York, N.Y.), 2011-06, Vol.6 (2), p.190-193 |
issn | 1558-9447 1558-9455 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3092900 |
source | Open Access: PubMed Central; SAGE |
subjects | AAHS Meeting AAHS Meeting Article Medicine Medicine & Public Health Orthopedics Plastic Surgery Surgery Surgical Orthopedics |
title | Dorsal Tangential View of the Wrist to Detect Screw Penetration to the Dorsal Cortex of the Distal Radius after Volar Fixed-Angle Plating |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T00%3A31%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Dorsal%20Tangential%20View%20of%20the%20Wrist%20to%20Detect%20Screw%20Penetration%20to%20the%20Dorsal%20Cortex%20of%20the%20Distal%20Radius%20after%20Volar%20Fixed-Angle%20Plating&rft.jtitle=Hand%20(New%20York,%20N.Y.)&rft.au=Ozer,%20Kagan&rft.date=2011-06&rft.volume=6&rft.issue=2&rft.spage=190&rft.epage=193&rft.pages=190-193&rft.issn=1558-9447&rft.eissn=1558-9455&rft_id=info:doi/10.1007/s11552-010-9316-2&rft_dat=%3Cproquest_pubme%3E1018344884%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3962-776aeab93f97f9a75efd4832e3085d451592748219ddc53edd5c462eff16465e3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1018344884&rft_id=info:pmid/22654703&rft_sage_id=10.1007_s11552-010-9316-2&rfr_iscdi=true |