Development and use of iron oxide nanoparticles (Part 1): Synthesis of iron oxide nanoparticles for MRI

Contrast agents, such as iron oxide, enhance MR images by altering the relaxation times of tissues in which the agent is present. They can also be used to label targeted molecular imaging probes. Unfortunately, no molecular imaging probe is currently available on the clinical MRI market. A promising...

Full description

Saved in:
Bibliographic Details
Published in:Biomedical imaging and intervention journal 2010-04, Vol.6 (2), p.e12-e12
Main Authors: Lodhia, J, Mandarano, G, Ferris, Nj, Eu, P, Cowell, Sf
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3922-6101de7bcc727c15c35bc8d7b69a9b1f76c59f7f419d6e56ffeda4f97805b90f3
cites cdi_FETCH-LOGICAL-c3922-6101de7bcc727c15c35bc8d7b69a9b1f76c59f7f419d6e56ffeda4f97805b90f3
container_end_page e12
container_issue 2
container_start_page e12
container_title Biomedical imaging and intervention journal
container_volume 6
creator Lodhia, J
Mandarano, G
Ferris, Nj
Eu, P
Cowell, Sf
description Contrast agents, such as iron oxide, enhance MR images by altering the relaxation times of tissues in which the agent is present. They can also be used to label targeted molecular imaging probes. Unfortunately, no molecular imaging probe is currently available on the clinical MRI market. A promising platform for MRI contrast agent development is nanotechnology, where superparamagnetic iron oxide nanoparticles (SPIONS) are tailored for MR contrast enhancement, and/or for molecular imaging. SPIONs can be produced using a range of methods and the choice of method will be influenced by the characteristics most important for a particular application. In addition, the ability to attach molecular markers to SPIONS heralds their application in molecular imaging.There are many reviews on SPION synthesis for MRI; however, these tend to be targeted to a chemistry audience. The development of MRI contrast agents attracts experienced researchers from many fields including some researchers with little knowledge of medical imaging or MRI. This situation presents medical radiation practitioners with opportunities for involvement, collaboration or leadership in research depending on their level of commitment and their ability to learn. Medical radiation practitioners already possess a large portion of the understanding, knowledge and skills necessary for involvement in MRI development and molecular imaging. Their expertise in imaging technology, patient care and radiation safety provides them with skills that are directly applicable to research on the development and application of SPIONs and MRI.In this paper we argue that MRI SPIONs, currently limited to major research centres, will have widespread clinical use in the future. We believe that knowledge about this growing area of research provides an opportunity for medical radiation practitioners to enhance their specialised expertise to ensure best practice in a truly multi-disciplinary environment. This review outlines how and why SPIONs can be synthesised and examines their characteristics and limitations in the context of MR imaging.
doi_str_mv 10.2349/biij.6.2.e12
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3097763</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>868768678</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3922-6101de7bcc727c15c35bc8d7b69a9b1f76c59f7f419d6e56ffeda4f97805b90f3</originalsourceid><addsrcrecordid>eNp9kc9LHDEcxUNRXLXePEvAQxW62_yYJJMeCsVaXbC0WD2HTOYbzTKbrMmO1P_eEVdZPfT0ffD98HiPh9A-JRPGK_2lCWE2kRM2Aco-oG1aMz4WgpONNT1CO6XMCKkqzvQWGjEqKSW82kY3P-AeurSYQ1xiG1vcF8DJ45BTxOlfaAFHG9PC5mVwHRR89GeQmB5_xX8f4vIWSij_5X3K-Nfl9CPa9LYrsLe6u-j65-nVyfn44vfZ9OT7xdhxzdhYUkJbUI1ziilHheOicXWrGqmtbqhX0gntla-obiUI6T20tvJa1UQ0mni-i749-y76Zg6tG2pl25lFDnObH0yywbz9xHBrbtK94UQrJflg8GllkNNdD2Vp5qE46DobIfXF1LJWspaqHsjDd-Qs9TkO7QzVgrJKi1oM1OdnyuVUSgb_moUS8zSgeRrQSMPMMOCAH6znf4VfFuOPVtmYeA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1951249585</pqid></control><display><type>article</type><title>Development and use of iron oxide nanoparticles (Part 1): Synthesis of iron oxide nanoparticles for MRI</title><source>PubMed Central Free</source><source>ProQuest Publicly Available Content</source><creator>Lodhia, J ; Mandarano, G ; Ferris, Nj ; Eu, P ; Cowell, Sf</creator><creatorcontrib>Lodhia, J ; Mandarano, G ; Ferris, Nj ; Eu, P ; Cowell, Sf</creatorcontrib><description>Contrast agents, such as iron oxide, enhance MR images by altering the relaxation times of tissues in which the agent is present. They can also be used to label targeted molecular imaging probes. Unfortunately, no molecular imaging probe is currently available on the clinical MRI market. A promising platform for MRI contrast agent development is nanotechnology, where superparamagnetic iron oxide nanoparticles (SPIONS) are tailored for MR contrast enhancement, and/or for molecular imaging. SPIONs can be produced using a range of methods and the choice of method will be influenced by the characteristics most important for a particular application. In addition, the ability to attach molecular markers to SPIONS heralds their application in molecular imaging.There are many reviews on SPION synthesis for MRI; however, these tend to be targeted to a chemistry audience. The development of MRI contrast agents attracts experienced researchers from many fields including some researchers with little knowledge of medical imaging or MRI. This situation presents medical radiation practitioners with opportunities for involvement, collaboration or leadership in research depending on their level of commitment and their ability to learn. Medical radiation practitioners already possess a large portion of the understanding, knowledge and skills necessary for involvement in MRI development and molecular imaging. Their expertise in imaging technology, patient care and radiation safety provides them with skills that are directly applicable to research on the development and application of SPIONs and MRI.In this paper we argue that MRI SPIONs, currently limited to major research centres, will have widespread clinical use in the future. We believe that knowledge about this growing area of research provides an opportunity for medical radiation practitioners to enhance their specialised expertise to ensure best practice in a truly multi-disciplinary environment. This review outlines how and why SPIONs can be synthesised and examines their characteristics and limitations in the context of MR imaging.</description><identifier>ISSN: 1823-5530</identifier><identifier>EISSN: 1823-5530</identifier><identifier>DOI: 10.2349/biij.6.2.e12</identifier><identifier>PMID: 21611034</identifier><language>eng</language><publisher>Malaysia: University of Malaya</publisher><subject>Nanoparticles ; Review</subject><ispartof>Biomedical imaging and intervention journal, 2010-04, Vol.6 (2), p.e12-e12</ispartof><rights>2010 Biomedical Imaging and Intervention Journal. This work is licensed under the Creative Commons Attribution License (https://creativecommons.org/licenses/by/3.0/) (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>2010 Biomedical Imaging and Intervention Journal 2010</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3922-6101de7bcc727c15c35bc8d7b69a9b1f76c59f7f419d6e56ffeda4f97805b90f3</citedby><cites>FETCH-LOGICAL-c3922-6101de7bcc727c15c35bc8d7b69a9b1f76c59f7f419d6e56ffeda4f97805b90f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/1951249585/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/1951249585?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/21611034$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lodhia, J</creatorcontrib><creatorcontrib>Mandarano, G</creatorcontrib><creatorcontrib>Ferris, Nj</creatorcontrib><creatorcontrib>Eu, P</creatorcontrib><creatorcontrib>Cowell, Sf</creatorcontrib><title>Development and use of iron oxide nanoparticles (Part 1): Synthesis of iron oxide nanoparticles for MRI</title><title>Biomedical imaging and intervention journal</title><addtitle>Biomed Imaging Interv J</addtitle><description>Contrast agents, such as iron oxide, enhance MR images by altering the relaxation times of tissues in which the agent is present. They can also be used to label targeted molecular imaging probes. Unfortunately, no molecular imaging probe is currently available on the clinical MRI market. A promising platform for MRI contrast agent development is nanotechnology, where superparamagnetic iron oxide nanoparticles (SPIONS) are tailored for MR contrast enhancement, and/or for molecular imaging. SPIONs can be produced using a range of methods and the choice of method will be influenced by the characteristics most important for a particular application. In addition, the ability to attach molecular markers to SPIONS heralds their application in molecular imaging.There are many reviews on SPION synthesis for MRI; however, these tend to be targeted to a chemistry audience. The development of MRI contrast agents attracts experienced researchers from many fields including some researchers with little knowledge of medical imaging or MRI. This situation presents medical radiation practitioners with opportunities for involvement, collaboration or leadership in research depending on their level of commitment and their ability to learn. Medical radiation practitioners already possess a large portion of the understanding, knowledge and skills necessary for involvement in MRI development and molecular imaging. Their expertise in imaging technology, patient care and radiation safety provides them with skills that are directly applicable to research on the development and application of SPIONs and MRI.In this paper we argue that MRI SPIONs, currently limited to major research centres, will have widespread clinical use in the future. We believe that knowledge about this growing area of research provides an opportunity for medical radiation practitioners to enhance their specialised expertise to ensure best practice in a truly multi-disciplinary environment. This review outlines how and why SPIONs can be synthesised and examines their characteristics and limitations in the context of MR imaging.</description><subject>Nanoparticles</subject><subject>Review</subject><issn>1823-5530</issn><issn>1823-5530</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNp9kc9LHDEcxUNRXLXePEvAQxW62_yYJJMeCsVaXbC0WD2HTOYbzTKbrMmO1P_eEVdZPfT0ffD98HiPh9A-JRPGK_2lCWE2kRM2Aco-oG1aMz4WgpONNT1CO6XMCKkqzvQWGjEqKSW82kY3P-AeurSYQ1xiG1vcF8DJ45BTxOlfaAFHG9PC5mVwHRR89GeQmB5_xX8f4vIWSij_5X3K-Nfl9CPa9LYrsLe6u-j65-nVyfn44vfZ9OT7xdhxzdhYUkJbUI1ziilHheOicXWrGqmtbqhX0gntla-obiUI6T20tvJa1UQ0mni-i749-y76Zg6tG2pl25lFDnObH0yywbz9xHBrbtK94UQrJflg8GllkNNdD2Vp5qE46DobIfXF1LJWspaqHsjDd-Qs9TkO7QzVgrJKi1oM1OdnyuVUSgb_moUS8zSgeRrQSMPMMOCAH6znf4VfFuOPVtmYeA</recordid><startdate>201004</startdate><enddate>201004</enddate><creator>Lodhia, J</creator><creator>Mandarano, G</creator><creator>Ferris, Nj</creator><creator>Eu, P</creator><creator>Cowell, Sf</creator><general>University of Malaya</general><general>Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Malaysia</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M7P</scope><scope>PHGZM</scope><scope>PHGZT</scope><scope>PIMPY</scope><scope>PKEHL</scope><scope>PQEST</scope><scope>PQGLB</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>201004</creationdate><title>Development and use of iron oxide nanoparticles (Part 1): Synthesis of iron oxide nanoparticles for MRI</title><author>Lodhia, J ; Mandarano, G ; Ferris, Nj ; Eu, P ; Cowell, Sf</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3922-6101de7bcc727c15c35bc8d7b69a9b1f76c59f7f419d6e56ffeda4f97805b90f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Nanoparticles</topic><topic>Review</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lodhia, J</creatorcontrib><creatorcontrib>Mandarano, G</creatorcontrib><creatorcontrib>Ferris, Nj</creatorcontrib><creatorcontrib>Eu, P</creatorcontrib><creatorcontrib>Cowell, Sf</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>ProQuest Central</collection><collection>Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Biological Science Database</collection><collection>ProQuest Central (New)</collection><collection>ProQuest One Academic (New)</collection><collection>ProQuest Publicly Available Content</collection><collection>ProQuest One Academic Middle East (New)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Applied &amp; Life Sciences</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Biomedical imaging and intervention journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lodhia, J</au><au>Mandarano, G</au><au>Ferris, Nj</au><au>Eu, P</au><au>Cowell, Sf</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development and use of iron oxide nanoparticles (Part 1): Synthesis of iron oxide nanoparticles for MRI</atitle><jtitle>Biomedical imaging and intervention journal</jtitle><addtitle>Biomed Imaging Interv J</addtitle><date>2010-04</date><risdate>2010</risdate><volume>6</volume><issue>2</issue><spage>e12</spage><epage>e12</epage><pages>e12-e12</pages><issn>1823-5530</issn><eissn>1823-5530</eissn><abstract>Contrast agents, such as iron oxide, enhance MR images by altering the relaxation times of tissues in which the agent is present. They can also be used to label targeted molecular imaging probes. Unfortunately, no molecular imaging probe is currently available on the clinical MRI market. A promising platform for MRI contrast agent development is nanotechnology, where superparamagnetic iron oxide nanoparticles (SPIONS) are tailored for MR contrast enhancement, and/or for molecular imaging. SPIONs can be produced using a range of methods and the choice of method will be influenced by the characteristics most important for a particular application. In addition, the ability to attach molecular markers to SPIONS heralds their application in molecular imaging.There are many reviews on SPION synthesis for MRI; however, these tend to be targeted to a chemistry audience. The development of MRI contrast agents attracts experienced researchers from many fields including some researchers with little knowledge of medical imaging or MRI. This situation presents medical radiation practitioners with opportunities for involvement, collaboration or leadership in research depending on their level of commitment and their ability to learn. Medical radiation practitioners already possess a large portion of the understanding, knowledge and skills necessary for involvement in MRI development and molecular imaging. Their expertise in imaging technology, patient care and radiation safety provides them with skills that are directly applicable to research on the development and application of SPIONs and MRI.In this paper we argue that MRI SPIONs, currently limited to major research centres, will have widespread clinical use in the future. We believe that knowledge about this growing area of research provides an opportunity for medical radiation practitioners to enhance their specialised expertise to ensure best practice in a truly multi-disciplinary environment. This review outlines how and why SPIONs can be synthesised and examines their characteristics and limitations in the context of MR imaging.</abstract><cop>Malaysia</cop><pub>University of Malaya</pub><pmid>21611034</pmid><doi>10.2349/biij.6.2.e12</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1823-5530
ispartof Biomedical imaging and intervention journal, 2010-04, Vol.6 (2), p.e12-e12
issn 1823-5530
1823-5530
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3097763
source PubMed Central Free; ProQuest Publicly Available Content
subjects Nanoparticles
Review
title Development and use of iron oxide nanoparticles (Part 1): Synthesis of iron oxide nanoparticles for MRI
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-03-06T11%3A11%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20and%20use%20of%20iron%20oxide%20nanoparticles%20(Part%201):%20Synthesis%20of%20iron%20oxide%20nanoparticles%20for%20MRI&rft.jtitle=Biomedical%20imaging%20and%20intervention%20journal&rft.au=Lodhia,%20J&rft.date=2010-04&rft.volume=6&rft.issue=2&rft.spage=e12&rft.epage=e12&rft.pages=e12-e12&rft.issn=1823-5530&rft.eissn=1823-5530&rft_id=info:doi/10.2349/biij.6.2.e12&rft_dat=%3Cproquest_pubme%3E868768678%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3922-6101de7bcc727c15c35bc8d7b69a9b1f76c59f7f419d6e56ffeda4f97805b90f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1951249585&rft_id=info:pmid/21611034&rfr_iscdi=true