Adding a radial dimension to the assessment of esophagogastric junction relaxation: validation studies of the 3D-eSleeve

High-resolution manometry (HRM) with esophageal pressure topography (EPT) allowed for the establishment of an objective quantitative measurement of esophagogastric junction (EGJ) relaxation, the integrated relaxation pressure (IRP). This study assessed whether or not a novel 3D-HRM assembly could im...

Full description

Saved in:
Bibliographic Details
Published in:American journal of physiology: Gastrointestinal and liver physiology 2012-08, Vol.303 (3), p.G275-G280
Main Authors: Nicodème, Frédéric, Pandolfino, John E, Lin, Zhiyue, Xiao, Yinglian, Escobar, Gabriela, Kahrilas, Peter J
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:High-resolution manometry (HRM) with esophageal pressure topography (EPT) allowed for the establishment of an objective quantitative measurement of esophagogastric junction (EGJ) relaxation, the integrated relaxation pressure (IRP). This study assessed whether or not a novel 3D-HRM assembly could improve on this measurement. Twenty-five normal subjects were studied with both a standard HRM assembly and a novel hybrid assembly (3D-HRM), including a 9.0 cm 3D-HRM segment composed of 96 radially dispersed independent pressure sensors. The standard IRP was computed using each assembly and compared with a novel paradigm, the 3D-IRP, an analysis premised on finding the axial maximum and radial minimum pressure at each sensor ring along the sleeve segment. Fourteen additional subjects underwent barium swallows with 3D-HRM and concurrent videofluoroscopy to compare the electronic sleeve (eSleeve) paradigm (circumferential average) to the 3D eSleeve paradigm (radial minimum) as a predictor of transphincteric flow. The 3D-IRP was significantly less than all other calculations of IRP with the upper limit of normal being 12 mmHg vs. 17 mmHg for the standard IRP. The sensitivity (0.78) and the specificity (0.88) of the 3D-eSleeve were also better than the standard eSleeve (0.55 and 0.85, respectively) for predicting flow permissive time verified fluoroscopically. The 3D-IRP and 3D-eSleeve calculated using the radial pressure minimum lowered the normative range of EGJ relaxation (upper limit of normal 12 mmHg) and yielded intraluminal pressure gradients that better correlated with bolus flow than did analysis paradigms based on circumferentially averaged pressure.
ISSN:0193-1857
1522-1547
DOI:10.1152/ajpgi.00063.2012