Loading…
Muscle Plasticity and Ankle Control After Repetitive Use of a Functional Electrical Stimulation Device for Foot Drop in Cerebral Palsy
Background/Objectives. The primary goal was to determine whether repetitive functional electrical stimulation (FES) for unilateral foot drop increases tibialis anterior (TA) muscle size compared with an untreated baseline and the contralateral side in cerebral palsy (CP). Secondary goals were to det...
Saved in:
Published in: | Neurorehabilitation and neural repair 2013-03, Vol.27 (3), p.200-207 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c533t-2927d769086f3ec066ce841fc6c22f5bea3d4c336e5c215cbfe694accd2f23ba3 |
---|---|
cites | cdi_FETCH-LOGICAL-c533t-2927d769086f3ec066ce841fc6c22f5bea3d4c336e5c215cbfe694accd2f23ba3 |
container_end_page | 207 |
container_issue | 3 |
container_start_page | 200 |
container_title | Neurorehabilitation and neural repair |
container_volume | 27 |
creator | Damiano, Diane L. Prosser, Laura A. Curatalo, Lindsey A. Alter, Katharine E. |
description | Background/Objectives. The primary goal was to determine whether repetitive functional electrical stimulation (FES) for unilateral foot drop increases tibialis anterior (TA) muscle size compared with an untreated baseline and the contralateral side in cerebral palsy (CP). Secondary goals were to determine whether positive changes in muscle size and gait, if found, accumulated during the 3 intervals during which participants used the device. FES devices differ from traditional orthoses that often restrict muscle activation and may exacerbate weakness, promote continued dependence on orthoses, or precipitate functional decline. Methods. Participants were 14 independent ambulators with inadequate dorsiflexion in swing, with a mean age of 13.1 years, evaluated before and after the 3-month baseline, 1-month device accommodation, 3-month primary intervention, and 3-month follow-up phases. The FES device (WalkAide) stimulated the common fibular nerve to dorsiflex the ankle and evert the foot while monitoring use. TA muscle ultrasound, gait velocity, and ankle kinematic data for barefoot and device conditions are reported. Results. Ultrasound measures of TA anatomic cross-sectional area and muscle thickness increased in the intervention compared with baseline and with the contralateral side and were maintained at follow-up. Maximum ankle dorsiflexion decreased at baseline but improved or was maintained during the intervention phase with and without the device, respectively. Muscle size gains were preserved at follow-up, but barefoot ankle motion returned to baseline values. Conclusions. This FES device produced evidence of use-dependent muscle plasticity in CP. Permanent improvements in voluntary ankle control after repetitive stimulation were not demonstrated. |
doi_str_mv | 10.1177/1545968312461716 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3579660</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1545968312461716</sage_id><sourcerecordid>1312171753</sourcerecordid><originalsourceid>FETCH-LOGICAL-c533t-2927d769086f3ec066ce841fc6c22f5bea3d4c336e5c215cbfe694accd2f23ba3</originalsourceid><addsrcrecordid>eNqNUU1vEzEQtRCItoE7J-QjlwV_7-4FKUobilREBfRseb3j4uKsg-2NlD_A78ZRSgVISJxmNO_N07x5CL2g5DWlbfuGSiF71XHKhKItVY_QKZWSNaoT4vGhF7I54CfoLOc7QhjvevIUnTBOBOu4OEU_PszZBsDXweTirS97bKYRL6dvdbiKU0kx4KUrkPAn2ELxxe8A32TA0WGD1_Nki4-TCfgigC3J29p-Ln4zB3MA8DnsvAXsYsLrGAs-T3GL_YRXkGBIlXxtQt4_Q09crfD8vi7Qzfriy-qyufr47v1qedVYyXlpWM_asVU96ZTjYIlSFjpBnVWWMScHMHwUlnMF0jIq7eBA9cJYOzLH-GD4Ar096m7nYQOjhWrQBL1NfmPSXkfj9Z_I5L_q27jTXLa9UqQKvLoXSPH7DLnojc8WQjATxDlryuuPCZOk_Q8qZTW0tjpbIHKk2hRzTuAeLqJEH5LWfyddV17-7uRh4Ve0ldAcCdncgr6Lc6op5X8L_gQr_7LL</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1312171753</pqid></control><display><type>article</type><title>Muscle Plasticity and Ankle Control After Repetitive Use of a Functional Electrical Stimulation Device for Foot Drop in Cerebral Palsy</title><source>SAGE</source><creator>Damiano, Diane L. ; Prosser, Laura A. ; Curatalo, Lindsey A. ; Alter, Katharine E.</creator><creatorcontrib>Damiano, Diane L. ; Prosser, Laura A. ; Curatalo, Lindsey A. ; Alter, Katharine E.</creatorcontrib><description>Background/Objectives. The primary goal was to determine whether repetitive functional electrical stimulation (FES) for unilateral foot drop increases tibialis anterior (TA) muscle size compared with an untreated baseline and the contralateral side in cerebral palsy (CP). Secondary goals were to determine whether positive changes in muscle size and gait, if found, accumulated during the 3 intervals during which participants used the device. FES devices differ from traditional orthoses that often restrict muscle activation and may exacerbate weakness, promote continued dependence on orthoses, or precipitate functional decline. Methods. Participants were 14 independent ambulators with inadequate dorsiflexion in swing, with a mean age of 13.1 years, evaluated before and after the 3-month baseline, 1-month device accommodation, 3-month primary intervention, and 3-month follow-up phases. The FES device (WalkAide) stimulated the common fibular nerve to dorsiflex the ankle and evert the foot while monitoring use. TA muscle ultrasound, gait velocity, and ankle kinematic data for barefoot and device conditions are reported. Results. Ultrasound measures of TA anatomic cross-sectional area and muscle thickness increased in the intervention compared with baseline and with the contralateral side and were maintained at follow-up. Maximum ankle dorsiflexion decreased at baseline but improved or was maintained during the intervention phase with and without the device, respectively. Muscle size gains were preserved at follow-up, but barefoot ankle motion returned to baseline values. Conclusions. This FES device produced evidence of use-dependent muscle plasticity in CP. Permanent improvements in voluntary ankle control after repetitive stimulation were not demonstrated.</description><identifier>ISSN: 1545-9683</identifier><identifier>EISSN: 1552-6844</identifier><identifier>DOI: 10.1177/1545968312461716</identifier><identifier>PMID: 23042834</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><subject>Adolescent ; Age ; Ankle - diagnostic imaging ; Ankle - physiopathology ; Cerebral Palsy - diagnostic imaging ; Cerebral Palsy - physiopathology ; Cerebral Palsy - therapy ; Child ; Electric Stimulation Therapy - instrumentation ; Electric Stimulation Therapy - methods ; Equipment and Supplies - standards ; Female ; Gait Disorders, Neurologic - physiopathology ; Humans ; Male ; Muscle, Skeletal - diagnostic imaging ; Muscle, Skeletal - physiopathology ; Secondary Prevention ; Treatment Outcome ; Ultrasonography ; Young Adult</subject><ispartof>Neurorehabilitation and neural repair, 2013-03, Vol.27 (3), p.200-207</ispartof><rights>The Author(s) 2013</rights><rights>The Author(s) 2012 2012</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c533t-2927d769086f3ec066ce841fc6c22f5bea3d4c336e5c215cbfe694accd2f23ba3</citedby><cites>FETCH-LOGICAL-c533t-2927d769086f3ec066ce841fc6c22f5bea3d4c336e5c215cbfe694accd2f23ba3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27923,27924,79235</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23042834$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Damiano, Diane L.</creatorcontrib><creatorcontrib>Prosser, Laura A.</creatorcontrib><creatorcontrib>Curatalo, Lindsey A.</creatorcontrib><creatorcontrib>Alter, Katharine E.</creatorcontrib><title>Muscle Plasticity and Ankle Control After Repetitive Use of a Functional Electrical Stimulation Device for Foot Drop in Cerebral Palsy</title><title>Neurorehabilitation and neural repair</title><addtitle>Neurorehabil Neural Repair</addtitle><description>Background/Objectives. The primary goal was to determine whether repetitive functional electrical stimulation (FES) for unilateral foot drop increases tibialis anterior (TA) muscle size compared with an untreated baseline and the contralateral side in cerebral palsy (CP). Secondary goals were to determine whether positive changes in muscle size and gait, if found, accumulated during the 3 intervals during which participants used the device. FES devices differ from traditional orthoses that often restrict muscle activation and may exacerbate weakness, promote continued dependence on orthoses, or precipitate functional decline. Methods. Participants were 14 independent ambulators with inadequate dorsiflexion in swing, with a mean age of 13.1 years, evaluated before and after the 3-month baseline, 1-month device accommodation, 3-month primary intervention, and 3-month follow-up phases. The FES device (WalkAide) stimulated the common fibular nerve to dorsiflex the ankle and evert the foot while monitoring use. TA muscle ultrasound, gait velocity, and ankle kinematic data for barefoot and device conditions are reported. Results. Ultrasound measures of TA anatomic cross-sectional area and muscle thickness increased in the intervention compared with baseline and with the contralateral side and were maintained at follow-up. Maximum ankle dorsiflexion decreased at baseline but improved or was maintained during the intervention phase with and without the device, respectively. Muscle size gains were preserved at follow-up, but barefoot ankle motion returned to baseline values. Conclusions. This FES device produced evidence of use-dependent muscle plasticity in CP. Permanent improvements in voluntary ankle control after repetitive stimulation were not demonstrated.</description><subject>Adolescent</subject><subject>Age</subject><subject>Ankle - diagnostic imaging</subject><subject>Ankle - physiopathology</subject><subject>Cerebral Palsy - diagnostic imaging</subject><subject>Cerebral Palsy - physiopathology</subject><subject>Cerebral Palsy - therapy</subject><subject>Child</subject><subject>Electric Stimulation Therapy - instrumentation</subject><subject>Electric Stimulation Therapy - methods</subject><subject>Equipment and Supplies - standards</subject><subject>Female</subject><subject>Gait Disorders, Neurologic - physiopathology</subject><subject>Humans</subject><subject>Male</subject><subject>Muscle, Skeletal - diagnostic imaging</subject><subject>Muscle, Skeletal - physiopathology</subject><subject>Secondary Prevention</subject><subject>Treatment Outcome</subject><subject>Ultrasonography</subject><subject>Young Adult</subject><issn>1545-9683</issn><issn>1552-6844</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNqNUU1vEzEQtRCItoE7J-QjlwV_7-4FKUobilREBfRseb3j4uKsg-2NlD_A78ZRSgVISJxmNO_N07x5CL2g5DWlbfuGSiF71XHKhKItVY_QKZWSNaoT4vGhF7I54CfoLOc7QhjvevIUnTBOBOu4OEU_PszZBsDXweTirS97bKYRL6dvdbiKU0kx4KUrkPAn2ELxxe8A32TA0WGD1_Nki4-TCfgigC3J29p-Ln4zB3MA8DnsvAXsYsLrGAs-T3GL_YRXkGBIlXxtQt4_Q09crfD8vi7Qzfriy-qyufr47v1qedVYyXlpWM_asVU96ZTjYIlSFjpBnVWWMScHMHwUlnMF0jIq7eBA9cJYOzLH-GD4Ar096m7nYQOjhWrQBL1NfmPSXkfj9Z_I5L_q27jTXLa9UqQKvLoXSPH7DLnojc8WQjATxDlryuuPCZOk_Q8qZTW0tjpbIHKk2hRzTuAeLqJEH5LWfyddV17-7uRh4Ve0ldAcCdncgr6Lc6op5X8L_gQr_7LL</recordid><startdate>20130301</startdate><enddate>20130301</enddate><creator>Damiano, Diane L.</creator><creator>Prosser, Laura A.</creator><creator>Curatalo, Lindsey A.</creator><creator>Alter, Katharine E.</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7TK</scope><scope>5PM</scope></search><sort><creationdate>20130301</creationdate><title>Muscle Plasticity and Ankle Control After Repetitive Use of a Functional Electrical Stimulation Device for Foot Drop in Cerebral Palsy</title><author>Damiano, Diane L. ; Prosser, Laura A. ; Curatalo, Lindsey A. ; Alter, Katharine E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c533t-2927d769086f3ec066ce841fc6c22f5bea3d4c336e5c215cbfe694accd2f23ba3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Adolescent</topic><topic>Age</topic><topic>Ankle - diagnostic imaging</topic><topic>Ankle - physiopathology</topic><topic>Cerebral Palsy - diagnostic imaging</topic><topic>Cerebral Palsy - physiopathology</topic><topic>Cerebral Palsy - therapy</topic><topic>Child</topic><topic>Electric Stimulation Therapy - instrumentation</topic><topic>Electric Stimulation Therapy - methods</topic><topic>Equipment and Supplies - standards</topic><topic>Female</topic><topic>Gait Disorders, Neurologic - physiopathology</topic><topic>Humans</topic><topic>Male</topic><topic>Muscle, Skeletal - diagnostic imaging</topic><topic>Muscle, Skeletal - physiopathology</topic><topic>Secondary Prevention</topic><topic>Treatment Outcome</topic><topic>Ultrasonography</topic><topic>Young Adult</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Damiano, Diane L.</creatorcontrib><creatorcontrib>Prosser, Laura A.</creatorcontrib><creatorcontrib>Curatalo, Lindsey A.</creatorcontrib><creatorcontrib>Alter, Katharine E.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Neurosciences Abstracts</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Neurorehabilitation and neural repair</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Damiano, Diane L.</au><au>Prosser, Laura A.</au><au>Curatalo, Lindsey A.</au><au>Alter, Katharine E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Muscle Plasticity and Ankle Control After Repetitive Use of a Functional Electrical Stimulation Device for Foot Drop in Cerebral Palsy</atitle><jtitle>Neurorehabilitation and neural repair</jtitle><addtitle>Neurorehabil Neural Repair</addtitle><date>2013-03-01</date><risdate>2013</risdate><volume>27</volume><issue>3</issue><spage>200</spage><epage>207</epage><pages>200-207</pages><issn>1545-9683</issn><eissn>1552-6844</eissn><abstract>Background/Objectives. The primary goal was to determine whether repetitive functional electrical stimulation (FES) for unilateral foot drop increases tibialis anterior (TA) muscle size compared with an untreated baseline and the contralateral side in cerebral palsy (CP). Secondary goals were to determine whether positive changes in muscle size and gait, if found, accumulated during the 3 intervals during which participants used the device. FES devices differ from traditional orthoses that often restrict muscle activation and may exacerbate weakness, promote continued dependence on orthoses, or precipitate functional decline. Methods. Participants were 14 independent ambulators with inadequate dorsiflexion in swing, with a mean age of 13.1 years, evaluated before and after the 3-month baseline, 1-month device accommodation, 3-month primary intervention, and 3-month follow-up phases. The FES device (WalkAide) stimulated the common fibular nerve to dorsiflex the ankle and evert the foot while monitoring use. TA muscle ultrasound, gait velocity, and ankle kinematic data for barefoot and device conditions are reported. Results. Ultrasound measures of TA anatomic cross-sectional area and muscle thickness increased in the intervention compared with baseline and with the contralateral side and were maintained at follow-up. Maximum ankle dorsiflexion decreased at baseline but improved or was maintained during the intervention phase with and without the device, respectively. Muscle size gains were preserved at follow-up, but barefoot ankle motion returned to baseline values. Conclusions. This FES device produced evidence of use-dependent muscle plasticity in CP. Permanent improvements in voluntary ankle control after repetitive stimulation were not demonstrated.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>23042834</pmid><doi>10.1177/1545968312461716</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1545-9683 |
ispartof | Neurorehabilitation and neural repair, 2013-03, Vol.27 (3), p.200-207 |
issn | 1545-9683 1552-6844 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3579660 |
source | SAGE |
subjects | Adolescent Age Ankle - diagnostic imaging Ankle - physiopathology Cerebral Palsy - diagnostic imaging Cerebral Palsy - physiopathology Cerebral Palsy - therapy Child Electric Stimulation Therapy - instrumentation Electric Stimulation Therapy - methods Equipment and Supplies - standards Female Gait Disorders, Neurologic - physiopathology Humans Male Muscle, Skeletal - diagnostic imaging Muscle, Skeletal - physiopathology Secondary Prevention Treatment Outcome Ultrasonography Young Adult |
title | Muscle Plasticity and Ankle Control After Repetitive Use of a Functional Electrical Stimulation Device for Foot Drop in Cerebral Palsy |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T07%3A56%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Muscle%20Plasticity%20and%20Ankle%20Control%20After%20Repetitive%20Use%20of%20a%20Functional%20Electrical%20Stimulation%20Device%20for%20Foot%20Drop%20in%20Cerebral%20Palsy&rft.jtitle=Neurorehabilitation%20and%20neural%20repair&rft.au=Damiano,%20Diane%20L.&rft.date=2013-03-01&rft.volume=27&rft.issue=3&rft.spage=200&rft.epage=207&rft.pages=200-207&rft.issn=1545-9683&rft.eissn=1552-6844&rft_id=info:doi/10.1177/1545968312461716&rft_dat=%3Cproquest_pubme%3E1312171753%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c533t-2927d769086f3ec066ce841fc6c22f5bea3d4c336e5c215cbfe694accd2f23ba3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1312171753&rft_id=info:pmid/23042834&rft_sage_id=10.1177_1545968312461716&rfr_iscdi=true |