Muscle Plasticity and Ankle Control After Repetitive Use of a Functional Electrical Stimulation Device for Foot Drop in Cerebral Palsy

Background/Objectives. The primary goal was to determine whether repetitive functional electrical stimulation (FES) for unilateral foot drop increases tibialis anterior (TA) muscle size compared with an untreated baseline and the contralateral side in cerebral palsy (CP). Secondary goals were to det...

Full description

Saved in:
Bibliographic Details
Published in:Neurorehabilitation and neural repair 2013-03, Vol.27 (3), p.200-207
Main Authors: Damiano, Diane L., Prosser, Laura A., Curatalo, Lindsey A., Alter, Katharine E.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c533t-2927d769086f3ec066ce841fc6c22f5bea3d4c336e5c215cbfe694accd2f23ba3
cites cdi_FETCH-LOGICAL-c533t-2927d769086f3ec066ce841fc6c22f5bea3d4c336e5c215cbfe694accd2f23ba3
container_end_page 207
container_issue 3
container_start_page 200
container_title Neurorehabilitation and neural repair
container_volume 27
creator Damiano, Diane L.
Prosser, Laura A.
Curatalo, Lindsey A.
Alter, Katharine E.
description Background/Objectives. The primary goal was to determine whether repetitive functional electrical stimulation (FES) for unilateral foot drop increases tibialis anterior (TA) muscle size compared with an untreated baseline and the contralateral side in cerebral palsy (CP). Secondary goals were to determine whether positive changes in muscle size and gait, if found, accumulated during the 3 intervals during which participants used the device. FES devices differ from traditional orthoses that often restrict muscle activation and may exacerbate weakness, promote continued dependence on orthoses, or precipitate functional decline. Methods. Participants were 14 independent ambulators with inadequate dorsiflexion in swing, with a mean age of 13.1 years, evaluated before and after the 3-month baseline, 1-month device accommodation, 3-month primary intervention, and 3-month follow-up phases. The FES device (WalkAide) stimulated the common fibular nerve to dorsiflex the ankle and evert the foot while monitoring use. TA muscle ultrasound, gait velocity, and ankle kinematic data for barefoot and device conditions are reported. Results. Ultrasound measures of TA anatomic cross-sectional area and muscle thickness increased in the intervention compared with baseline and with the contralateral side and were maintained at follow-up. Maximum ankle dorsiflexion decreased at baseline but improved or was maintained during the intervention phase with and without the device, respectively. Muscle size gains were preserved at follow-up, but barefoot ankle motion returned to baseline values. Conclusions. This FES device produced evidence of use-dependent muscle plasticity in CP. Permanent improvements in voluntary ankle control after repetitive stimulation were not demonstrated.
doi_str_mv 10.1177/1545968312461716
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3579660</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1545968312461716</sage_id><sourcerecordid>1312171753</sourcerecordid><originalsourceid>FETCH-LOGICAL-c533t-2927d769086f3ec066ce841fc6c22f5bea3d4c336e5c215cbfe694accd2f23ba3</originalsourceid><addsrcrecordid>eNqNUU1vEzEQtRCItoE7J-QjlwV_7-4FKUobilREBfRseb3j4uKsg-2NlD_A78ZRSgVISJxmNO_N07x5CL2g5DWlbfuGSiF71XHKhKItVY_QKZWSNaoT4vGhF7I54CfoLOc7QhjvevIUnTBOBOu4OEU_PszZBsDXweTirS97bKYRL6dvdbiKU0kx4KUrkPAn2ELxxe8A32TA0WGD1_Nki4-TCfgigC3J29p-Ln4zB3MA8DnsvAXsYsLrGAs-T3GL_YRXkGBIlXxtQt4_Q09crfD8vi7Qzfriy-qyufr47v1qedVYyXlpWM_asVU96ZTjYIlSFjpBnVWWMScHMHwUlnMF0jIq7eBA9cJYOzLH-GD4Ar096m7nYQOjhWrQBL1NfmPSXkfj9Z_I5L_q27jTXLa9UqQKvLoXSPH7DLnojc8WQjATxDlryuuPCZOk_Q8qZTW0tjpbIHKk2hRzTuAeLqJEH5LWfyddV17-7uRh4Ve0ldAcCdncgr6Lc6op5X8L_gQr_7LL</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1312171753</pqid></control><display><type>article</type><title>Muscle Plasticity and Ankle Control After Repetitive Use of a Functional Electrical Stimulation Device for Foot Drop in Cerebral Palsy</title><source>SAGE</source><creator>Damiano, Diane L. ; Prosser, Laura A. ; Curatalo, Lindsey A. ; Alter, Katharine E.</creator><creatorcontrib>Damiano, Diane L. ; Prosser, Laura A. ; Curatalo, Lindsey A. ; Alter, Katharine E.</creatorcontrib><description>Background/Objectives. The primary goal was to determine whether repetitive functional electrical stimulation (FES) for unilateral foot drop increases tibialis anterior (TA) muscle size compared with an untreated baseline and the contralateral side in cerebral palsy (CP). Secondary goals were to determine whether positive changes in muscle size and gait, if found, accumulated during the 3 intervals during which participants used the device. FES devices differ from traditional orthoses that often restrict muscle activation and may exacerbate weakness, promote continued dependence on orthoses, or precipitate functional decline. Methods. Participants were 14 independent ambulators with inadequate dorsiflexion in swing, with a mean age of 13.1 years, evaluated before and after the 3-month baseline, 1-month device accommodation, 3-month primary intervention, and 3-month follow-up phases. The FES device (WalkAide) stimulated the common fibular nerve to dorsiflex the ankle and evert the foot while monitoring use. TA muscle ultrasound, gait velocity, and ankle kinematic data for barefoot and device conditions are reported. Results. Ultrasound measures of TA anatomic cross-sectional area and muscle thickness increased in the intervention compared with baseline and with the contralateral side and were maintained at follow-up. Maximum ankle dorsiflexion decreased at baseline but improved or was maintained during the intervention phase with and without the device, respectively. Muscle size gains were preserved at follow-up, but barefoot ankle motion returned to baseline values. Conclusions. This FES device produced evidence of use-dependent muscle plasticity in CP. Permanent improvements in voluntary ankle control after repetitive stimulation were not demonstrated.</description><identifier>ISSN: 1545-9683</identifier><identifier>EISSN: 1552-6844</identifier><identifier>DOI: 10.1177/1545968312461716</identifier><identifier>PMID: 23042834</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><subject>Adolescent ; Age ; Ankle - diagnostic imaging ; Ankle - physiopathology ; Cerebral Palsy - diagnostic imaging ; Cerebral Palsy - physiopathology ; Cerebral Palsy - therapy ; Child ; Electric Stimulation Therapy - instrumentation ; Electric Stimulation Therapy - methods ; Equipment and Supplies - standards ; Female ; Gait Disorders, Neurologic - physiopathology ; Humans ; Male ; Muscle, Skeletal - diagnostic imaging ; Muscle, Skeletal - physiopathology ; Secondary Prevention ; Treatment Outcome ; Ultrasonography ; Young Adult</subject><ispartof>Neurorehabilitation and neural repair, 2013-03, Vol.27 (3), p.200-207</ispartof><rights>The Author(s) 2013</rights><rights>The Author(s) 2012 2012</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c533t-2927d769086f3ec066ce841fc6c22f5bea3d4c336e5c215cbfe694accd2f23ba3</citedby><cites>FETCH-LOGICAL-c533t-2927d769086f3ec066ce841fc6c22f5bea3d4c336e5c215cbfe694accd2f23ba3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27923,27924,79235</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23042834$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Damiano, Diane L.</creatorcontrib><creatorcontrib>Prosser, Laura A.</creatorcontrib><creatorcontrib>Curatalo, Lindsey A.</creatorcontrib><creatorcontrib>Alter, Katharine E.</creatorcontrib><title>Muscle Plasticity and Ankle Control After Repetitive Use of a Functional Electrical Stimulation Device for Foot Drop in Cerebral Palsy</title><title>Neurorehabilitation and neural repair</title><addtitle>Neurorehabil Neural Repair</addtitle><description>Background/Objectives. The primary goal was to determine whether repetitive functional electrical stimulation (FES) for unilateral foot drop increases tibialis anterior (TA) muscle size compared with an untreated baseline and the contralateral side in cerebral palsy (CP). Secondary goals were to determine whether positive changes in muscle size and gait, if found, accumulated during the 3 intervals during which participants used the device. FES devices differ from traditional orthoses that often restrict muscle activation and may exacerbate weakness, promote continued dependence on orthoses, or precipitate functional decline. Methods. Participants were 14 independent ambulators with inadequate dorsiflexion in swing, with a mean age of 13.1 years, evaluated before and after the 3-month baseline, 1-month device accommodation, 3-month primary intervention, and 3-month follow-up phases. The FES device (WalkAide) stimulated the common fibular nerve to dorsiflex the ankle and evert the foot while monitoring use. TA muscle ultrasound, gait velocity, and ankle kinematic data for barefoot and device conditions are reported. Results. Ultrasound measures of TA anatomic cross-sectional area and muscle thickness increased in the intervention compared with baseline and with the contralateral side and were maintained at follow-up. Maximum ankle dorsiflexion decreased at baseline but improved or was maintained during the intervention phase with and without the device, respectively. Muscle size gains were preserved at follow-up, but barefoot ankle motion returned to baseline values. Conclusions. This FES device produced evidence of use-dependent muscle plasticity in CP. Permanent improvements in voluntary ankle control after repetitive stimulation were not demonstrated.</description><subject>Adolescent</subject><subject>Age</subject><subject>Ankle - diagnostic imaging</subject><subject>Ankle - physiopathology</subject><subject>Cerebral Palsy - diagnostic imaging</subject><subject>Cerebral Palsy - physiopathology</subject><subject>Cerebral Palsy - therapy</subject><subject>Child</subject><subject>Electric Stimulation Therapy - instrumentation</subject><subject>Electric Stimulation Therapy - methods</subject><subject>Equipment and Supplies - standards</subject><subject>Female</subject><subject>Gait Disorders, Neurologic - physiopathology</subject><subject>Humans</subject><subject>Male</subject><subject>Muscle, Skeletal - diagnostic imaging</subject><subject>Muscle, Skeletal - physiopathology</subject><subject>Secondary Prevention</subject><subject>Treatment Outcome</subject><subject>Ultrasonography</subject><subject>Young Adult</subject><issn>1545-9683</issn><issn>1552-6844</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNqNUU1vEzEQtRCItoE7J-QjlwV_7-4FKUobilREBfRseb3j4uKsg-2NlD_A78ZRSgVISJxmNO_N07x5CL2g5DWlbfuGSiF71XHKhKItVY_QKZWSNaoT4vGhF7I54CfoLOc7QhjvevIUnTBOBOu4OEU_PszZBsDXweTirS97bKYRL6dvdbiKU0kx4KUrkPAn2ELxxe8A32TA0WGD1_Nki4-TCfgigC3J29p-Ln4zB3MA8DnsvAXsYsLrGAs-T3GL_YRXkGBIlXxtQt4_Q09crfD8vi7Qzfriy-qyufr47v1qedVYyXlpWM_asVU96ZTjYIlSFjpBnVWWMScHMHwUlnMF0jIq7eBA9cJYOzLH-GD4Ar096m7nYQOjhWrQBL1NfmPSXkfj9Z_I5L_q27jTXLa9UqQKvLoXSPH7DLnojc8WQjATxDlryuuPCZOk_Q8qZTW0tjpbIHKk2hRzTuAeLqJEH5LWfyddV17-7uRh4Ve0ldAcCdncgr6Lc6op5X8L_gQr_7LL</recordid><startdate>20130301</startdate><enddate>20130301</enddate><creator>Damiano, Diane L.</creator><creator>Prosser, Laura A.</creator><creator>Curatalo, Lindsey A.</creator><creator>Alter, Katharine E.</creator><general>SAGE Publications</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>7TK</scope><scope>5PM</scope></search><sort><creationdate>20130301</creationdate><title>Muscle Plasticity and Ankle Control After Repetitive Use of a Functional Electrical Stimulation Device for Foot Drop in Cerebral Palsy</title><author>Damiano, Diane L. ; Prosser, Laura A. ; Curatalo, Lindsey A. ; Alter, Katharine E.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c533t-2927d769086f3ec066ce841fc6c22f5bea3d4c336e5c215cbfe694accd2f23ba3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Adolescent</topic><topic>Age</topic><topic>Ankle - diagnostic imaging</topic><topic>Ankle - physiopathology</topic><topic>Cerebral Palsy - diagnostic imaging</topic><topic>Cerebral Palsy - physiopathology</topic><topic>Cerebral Palsy - therapy</topic><topic>Child</topic><topic>Electric Stimulation Therapy - instrumentation</topic><topic>Electric Stimulation Therapy - methods</topic><topic>Equipment and Supplies - standards</topic><topic>Female</topic><topic>Gait Disorders, Neurologic - physiopathology</topic><topic>Humans</topic><topic>Male</topic><topic>Muscle, Skeletal - diagnostic imaging</topic><topic>Muscle, Skeletal - physiopathology</topic><topic>Secondary Prevention</topic><topic>Treatment Outcome</topic><topic>Ultrasonography</topic><topic>Young Adult</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Damiano, Diane L.</creatorcontrib><creatorcontrib>Prosser, Laura A.</creatorcontrib><creatorcontrib>Curatalo, Lindsey A.</creatorcontrib><creatorcontrib>Alter, Katharine E.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>Neurosciences Abstracts</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Neurorehabilitation and neural repair</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Damiano, Diane L.</au><au>Prosser, Laura A.</au><au>Curatalo, Lindsey A.</au><au>Alter, Katharine E.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Muscle Plasticity and Ankle Control After Repetitive Use of a Functional Electrical Stimulation Device for Foot Drop in Cerebral Palsy</atitle><jtitle>Neurorehabilitation and neural repair</jtitle><addtitle>Neurorehabil Neural Repair</addtitle><date>2013-03-01</date><risdate>2013</risdate><volume>27</volume><issue>3</issue><spage>200</spage><epage>207</epage><pages>200-207</pages><issn>1545-9683</issn><eissn>1552-6844</eissn><abstract>Background/Objectives. The primary goal was to determine whether repetitive functional electrical stimulation (FES) for unilateral foot drop increases tibialis anterior (TA) muscle size compared with an untreated baseline and the contralateral side in cerebral palsy (CP). Secondary goals were to determine whether positive changes in muscle size and gait, if found, accumulated during the 3 intervals during which participants used the device. FES devices differ from traditional orthoses that often restrict muscle activation and may exacerbate weakness, promote continued dependence on orthoses, or precipitate functional decline. Methods. Participants were 14 independent ambulators with inadequate dorsiflexion in swing, with a mean age of 13.1 years, evaluated before and after the 3-month baseline, 1-month device accommodation, 3-month primary intervention, and 3-month follow-up phases. The FES device (WalkAide) stimulated the common fibular nerve to dorsiflex the ankle and evert the foot while monitoring use. TA muscle ultrasound, gait velocity, and ankle kinematic data for barefoot and device conditions are reported. Results. Ultrasound measures of TA anatomic cross-sectional area and muscle thickness increased in the intervention compared with baseline and with the contralateral side and were maintained at follow-up. Maximum ankle dorsiflexion decreased at baseline but improved or was maintained during the intervention phase with and without the device, respectively. Muscle size gains were preserved at follow-up, but barefoot ankle motion returned to baseline values. Conclusions. This FES device produced evidence of use-dependent muscle plasticity in CP. Permanent improvements in voluntary ankle control after repetitive stimulation were not demonstrated.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>23042834</pmid><doi>10.1177/1545968312461716</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1545-9683
ispartof Neurorehabilitation and neural repair, 2013-03, Vol.27 (3), p.200-207
issn 1545-9683
1552-6844
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3579660
source SAGE
subjects Adolescent
Age
Ankle - diagnostic imaging
Ankle - physiopathology
Cerebral Palsy - diagnostic imaging
Cerebral Palsy - physiopathology
Cerebral Palsy - therapy
Child
Electric Stimulation Therapy - instrumentation
Electric Stimulation Therapy - methods
Equipment and Supplies - standards
Female
Gait Disorders, Neurologic - physiopathology
Humans
Male
Muscle, Skeletal - diagnostic imaging
Muscle, Skeletal - physiopathology
Secondary Prevention
Treatment Outcome
Ultrasonography
Young Adult
title Muscle Plasticity and Ankle Control After Repetitive Use of a Functional Electrical Stimulation Device for Foot Drop in Cerebral Palsy
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T07%3A56%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Muscle%20Plasticity%20and%20Ankle%20Control%20After%20Repetitive%20Use%20of%20a%20Functional%20Electrical%20Stimulation%20Device%20for%20Foot%20Drop%20in%20Cerebral%20Palsy&rft.jtitle=Neurorehabilitation%20and%20neural%20repair&rft.au=Damiano,%20Diane%20L.&rft.date=2013-03-01&rft.volume=27&rft.issue=3&rft.spage=200&rft.epage=207&rft.pages=200-207&rft.issn=1545-9683&rft.eissn=1552-6844&rft_id=info:doi/10.1177/1545968312461716&rft_dat=%3Cproquest_pubme%3E1312171753%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c533t-2927d769086f3ec066ce841fc6c22f5bea3d4c336e5c215cbfe694accd2f23ba3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1312171753&rft_id=info:pmid/23042834&rft_sage_id=10.1177_1545968312461716&rfr_iscdi=true