Superior haemodynamic stability during off-pump coronary surgery with thoracic epidural anaesthesia: results from a prospective randomized controlled trial
OBJECTIVES Off-pump coronary artery bypass (OPCAB) surgery is a technically more demanding strategy of myocardial revascularization compared with the standard on-pump technique. Thoracic epidural anaesthesia, by reducing sympathetic stress, may ameliorate the haemodynamic changes occurring during OP...
Saved in:
Published in: | Interactive cardiovascular and thoracic surgery 2013-05, Vol.16 (5), p.602-607 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Request full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | OBJECTIVES
Off-pump coronary artery bypass (OPCAB) surgery is a technically more demanding strategy of myocardial revascularization compared with the standard on-pump technique. Thoracic epidural anaesthesia, by reducing sympathetic stress, may ameliorate the haemodynamic changes occurring during OPCAB surgery. The aim of this randomized controlled trial was to evaluate the impact of thoracic epidural anaesthesia on intraoperative haemodynamics in patients undergoing OPCAB surgery.
METHODS
Two hundred and twenty-six patients were randomized to either general anaesthesia plus epidural (GAE) (n = 109) or general anaesthesia (GA) only (n = 117). Mean arterial blood pressure (MAP), heart rate (HR) and central venous pressure (CVP) were measured before sternotomy and subsequently after positioning the heart for each distal anastomosis.
RESULTS
Both groups were well balanced with respect to baseline characteristics and received a standardized anaesthesia. The MAP decreased in both groups with no significant difference (mean difference (GAE minus GA) −1.11, 95% CI −3.06 to 0.84, P = 0.26). The HR increased in both groups after sternotomy but was significantly less in the GAE group (mean difference (GAE minus GA) −4.29, 95% CI −7.10 to −1.48, P = 0.003). The CVP also increased in both groups after sternotomy, but the difference between the groups varied over time (P = 0.05). A difference was observed at the third anastomosis when the heart was in position for the revascularization of the circumflex artery (mean difference (GAE minus GA) +2.09, 95% CI 0.21-3.96, P = 0.03), but not at other time points. The incidence of new arrhythmias was also significantly lower in the GAE compared with the GA group (OR = 0.41, 95% CI 0.22-0.78, P = 0.01).
CONCLUSION
Thoracic epidural with general anaesthesia minimizes the intraoperative haemodynamic changes that occur during heart positioning and stabilization for distal coronary anastomosis in OPCAB surgery. |
---|---|