Determination of square equivalent field for rectangular field in electron therapy
Equivalent field for electron beams is considered by using pencil beam theory. According to the Fermi-Eyges model the dose distribution of an electron pencil beam has a Gaussian profile. For this function determination of mean square radial displacement scattering of electrons is important. In this...
Saved in:
Published in: | Journal of medical physics 2013-04, Vol.38 (2), p.82-86 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | cdi_FETCH-LOGICAL-c540n-1524d9b264e109493a11fe61cf9206e3f43ccce84461e0963e90bb58f3b68e23 |
container_end_page | 86 |
container_issue | 2 |
container_start_page | 82 |
container_title | Journal of medical physics |
container_volume | 38 |
creator | Tahmasebi Birgani, Mohammad Behrouz, Mohammad Aliakbari, Saeedeh Hosseini, Seyed Khezerloo, Davood |
description | Equivalent field for electron beams is considered by using pencil beam theory. According to the Fermi-Eyges model the dose distribution of an electron pencil beam has a Gaussian profile. For this function determination of mean square radial displacement scattering of electrons is important. In this study the contribution of back scatter electron has been taken into account by using the multiple scattering theories for calculating mean square radial displacement scattering. The dimension of standard equivalent field depends on depth and shape of treatment field. Here the depth under study is the depth that mean square radial displacement scattering is extremum and the shape of treatment field is rectangular. In this study four energies were used 6, 9,12 and 15 MeV electron beams of 2100C/D Varian Linac. Findings of this study are based on analytical calculations, which are in good agreement with other experimental data. The findings of this study that were resulted from formula, shows, for all circular fields of radius ≥LSE (lateral scattering equilibrium) were considered broad field and equivalent. For validating the findings, Percentage Depth Dose (PDD) and Output factors were measured in 15 MeV electron beams for 7 × 3-cm, 6 × 4-cm and 4 × 2-cm and their equivalent squares and equivalent circular fields and compared. |
doi_str_mv | 10.4103/0971-6203.111317 |
format | article |
fullrecord | <record><control><sourceid>gale_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3683305</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A330727857</galeid><sourcerecordid>A330727857</sourcerecordid><originalsourceid>FETCH-LOGICAL-c540n-1524d9b264e109493a11fe61cf9206e3f43ccce84461e0963e90bb58f3b68e23</originalsourceid><addsrcrecordid>eNptks9r2zAcxcXYWLNu952GYZddnOlrybJ1GYR2v6AwGL0LWfkqVStLiWw39L-fQtLQjMgHwVef9yQ_HiEfgc45UPaVygZKUVE2BwAGzSsyAynbkklgr8nseHxB3g3DPaW8lpy_JRcVaxrBAGbk7zWOmHoX9OhiKKIths2kExa4mdyj9hjGwjr0y8LGVCQ0ow6ryet0mLpQoM_TlMXjHSa9fnpP3ljtB_xw2C_J7Y_vt1e_yps_P39fLW5KU3MaSqgrvpRdJTgClVwyDWBRgLGyogKZ5cwYgy3nApBKwVDSrqtbyzrRYsUuybe97Xrqelya_NKkvVon1-v0pKJ26vQkuDu1io-KiZYxWmeDLweDFDcTDqPq3WDQex0wToMCJnJ-goLI6Of_0Ps4pZD_LlM1qxtgeR2pVc5NuWBjvtfsTNUi39hUTVs3mSrPUCsMOTwfA1qXxyf8_AyfvyX2zpwV0L3ApDgMCe0xE6BqVxu164Xa9ULta5Mln15meRQ89yQDiz2wjT73ZXjw0xaTyuxDiNsT4_KFsWor9Vww9g_i1NB8</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1353571333</pqid></control><display><type>article</type><title>Determination of square equivalent field for rectangular field in electron therapy</title><source>Open Access: PubMed Central</source><source>Medknow Open Access Medical Journals</source><source>Publicly Available Content (ProQuest)</source><source>IngentaConnect Journals</source><creator>Tahmasebi Birgani, Mohammad ; Behrouz, Mohammad ; Aliakbari, Saeedeh ; Hosseini, Seyed ; Khezerloo, Davood</creator><creatorcontrib>Tahmasebi Birgani, Mohammad ; Behrouz, Mohammad ; Aliakbari, Saeedeh ; Hosseini, Seyed ; Khezerloo, Davood</creatorcontrib><description>Equivalent field for electron beams is considered by using pencil beam theory. According to the Fermi-Eyges model the dose distribution of an electron pencil beam has a Gaussian profile. For this function determination of mean square radial displacement scattering of electrons is important. In this study the contribution of back scatter electron has been taken into account by using the multiple scattering theories for calculating mean square radial displacement scattering. The dimension of standard equivalent field depends on depth and shape of treatment field. Here the depth under study is the depth that mean square radial displacement scattering is extremum and the shape of treatment field is rectangular. In this study four energies were used 6, 9,12 and 15 MeV electron beams of 2100C/D Varian Linac. Findings of this study are based on analytical calculations, which are in good agreement with other experimental data. The findings of this study that were resulted from formula, shows, for all circular fields of radius ≥LSE (lateral scattering equilibrium) were considered broad field and equivalent. For validating the findings, Percentage Depth Dose (PDD) and Output factors were measured in 15 MeV electron beams for 7 × 3-cm, 6 × 4-cm and 4 × 2-cm and their equivalent squares and equivalent circular fields and compared.</description><identifier>ISSN: 0971-6203</identifier><identifier>EISSN: 1998-3913</identifier><identifier>DOI: 10.4103/0971-6203.111317</identifier><identifier>PMID: 23776311</identifier><language>eng</language><publisher>India: Medknow Publications Pvt Ltd</publisher><subject>Nuclear medicine ; Original ; Software ; Studies</subject><ispartof>Journal of medical physics, 2013-04, Vol.38 (2), p.82-86</ispartof><rights>COPYRIGHT 2013 Medknow Publications and Media Pvt. Ltd.</rights><rights>Copyright Medknow Publications & Media Pvt Ltd Apr 2013</rights><rights>Copyright: © Journal of Medical Physics 2013</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c540n-1524d9b264e109493a11fe61cf9206e3f43ccce84461e0963e90bb58f3b68e23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3683305/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/1353571333?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,25752,27457,27923,27924,37011,37012,44589,53790,53792</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23776311$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Tahmasebi Birgani, Mohammad</creatorcontrib><creatorcontrib>Behrouz, Mohammad</creatorcontrib><creatorcontrib>Aliakbari, Saeedeh</creatorcontrib><creatorcontrib>Hosseini, Seyed</creatorcontrib><creatorcontrib>Khezerloo, Davood</creatorcontrib><title>Determination of square equivalent field for rectangular field in electron therapy</title><title>Journal of medical physics</title><addtitle>J Med Phys</addtitle><description>Equivalent field for electron beams is considered by using pencil beam theory. According to the Fermi-Eyges model the dose distribution of an electron pencil beam has a Gaussian profile. For this function determination of mean square radial displacement scattering of electrons is important. In this study the contribution of back scatter electron has been taken into account by using the multiple scattering theories for calculating mean square radial displacement scattering. The dimension of standard equivalent field depends on depth and shape of treatment field. Here the depth under study is the depth that mean square radial displacement scattering is extremum and the shape of treatment field is rectangular. In this study four energies were used 6, 9,12 and 15 MeV electron beams of 2100C/D Varian Linac. Findings of this study are based on analytical calculations, which are in good agreement with other experimental data. The findings of this study that were resulted from formula, shows, for all circular fields of radius ≥LSE (lateral scattering equilibrium) were considered broad field and equivalent. For validating the findings, Percentage Depth Dose (PDD) and Output factors were measured in 15 MeV electron beams for 7 × 3-cm, 6 × 4-cm and 4 × 2-cm and their equivalent squares and equivalent circular fields and compared.</description><subject>Nuclear medicine</subject><subject>Original</subject><subject>Software</subject><subject>Studies</subject><issn>0971-6203</issn><issn>1998-3913</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNptks9r2zAcxcXYWLNu952GYZddnOlrybJ1GYR2v6AwGL0LWfkqVStLiWw39L-fQtLQjMgHwVef9yQ_HiEfgc45UPaVygZKUVE2BwAGzSsyAynbkklgr8nseHxB3g3DPaW8lpy_JRcVaxrBAGbk7zWOmHoX9OhiKKIths2kExa4mdyj9hjGwjr0y8LGVCQ0ow6ryet0mLpQoM_TlMXjHSa9fnpP3ljtB_xw2C_J7Y_vt1e_yps_P39fLW5KU3MaSqgrvpRdJTgClVwyDWBRgLGyogKZ5cwYgy3nApBKwVDSrqtbyzrRYsUuybe97Xrqelya_NKkvVon1-v0pKJ26vQkuDu1io-KiZYxWmeDLweDFDcTDqPq3WDQex0wToMCJnJ-goLI6Of_0Ps4pZD_LlM1qxtgeR2pVc5NuWBjvtfsTNUi39hUTVs3mSrPUCsMOTwfA1qXxyf8_AyfvyX2zpwV0L3ApDgMCe0xE6BqVxu164Xa9ULta5Mln15meRQ89yQDiz2wjT73ZXjw0xaTyuxDiNsT4_KFsWor9Vww9g_i1NB8</recordid><startdate>20130401</startdate><enddate>20130401</enddate><creator>Tahmasebi Birgani, Mohammad</creator><creator>Behrouz, Mohammad</creator><creator>Aliakbari, Saeedeh</creator><creator>Hosseini, Seyed</creator><creator>Khezerloo, Davood</creator><general>Medknow Publications Pvt Ltd</general><general>Medknow Publications and Media Pvt. Ltd</general><general>Medknow Publications & Media Pvt. Ltd</general><general>Medknow Publications & Media Pvt Ltd</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FE</scope><scope>8FG</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>M0S</scope><scope>M2O</scope><scope>MBDVC</scope><scope>P5Z</scope><scope>P62</scope><scope>PADUT</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>Q9U</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20130401</creationdate><title>Determination of square equivalent field for rectangular field in electron therapy</title><author>Tahmasebi Birgani, Mohammad ; Behrouz, Mohammad ; Aliakbari, Saeedeh ; Hosseini, Seyed ; Khezerloo, Davood</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c540n-1524d9b264e109493a11fe61cf9206e3f43ccce84461e0963e90bb58f3b68e23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><topic>Nuclear medicine</topic><topic>Original</topic><topic>Software</topic><topic>Studies</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tahmasebi Birgani, Mohammad</creatorcontrib><creatorcontrib>Behrouz, Mohammad</creatorcontrib><creatorcontrib>Aliakbari, Saeedeh</creatorcontrib><creatorcontrib>Hosseini, Seyed</creatorcontrib><creatorcontrib>Khezerloo, Davood</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>ProQuest - Health & Medical Complete保健、医学与药学数据库</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>ProQuest research library</collection><collection>Research Library (Corporate)</collection><collection>Advanced Technologies & Aerospace Database</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>Research Library China</collection><collection>Publicly Available Content (ProQuest)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of medical physics</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tahmasebi Birgani, Mohammad</au><au>Behrouz, Mohammad</au><au>Aliakbari, Saeedeh</au><au>Hosseini, Seyed</au><au>Khezerloo, Davood</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Determination of square equivalent field for rectangular field in electron therapy</atitle><jtitle>Journal of medical physics</jtitle><addtitle>J Med Phys</addtitle><date>2013-04-01</date><risdate>2013</risdate><volume>38</volume><issue>2</issue><spage>82</spage><epage>86</epage><pages>82-86</pages><issn>0971-6203</issn><eissn>1998-3913</eissn><abstract>Equivalent field for electron beams is considered by using pencil beam theory. According to the Fermi-Eyges model the dose distribution of an electron pencil beam has a Gaussian profile. For this function determination of mean square radial displacement scattering of electrons is important. In this study the contribution of back scatter electron has been taken into account by using the multiple scattering theories for calculating mean square radial displacement scattering. The dimension of standard equivalent field depends on depth and shape of treatment field. Here the depth under study is the depth that mean square radial displacement scattering is extremum and the shape of treatment field is rectangular. In this study four energies were used 6, 9,12 and 15 MeV electron beams of 2100C/D Varian Linac. Findings of this study are based on analytical calculations, which are in good agreement with other experimental data. The findings of this study that were resulted from formula, shows, for all circular fields of radius ≥LSE (lateral scattering equilibrium) were considered broad field and equivalent. For validating the findings, Percentage Depth Dose (PDD) and Output factors were measured in 15 MeV electron beams for 7 × 3-cm, 6 × 4-cm and 4 × 2-cm and their equivalent squares and equivalent circular fields and compared.</abstract><cop>India</cop><pub>Medknow Publications Pvt Ltd</pub><pmid>23776311</pmid><doi>10.4103/0971-6203.111317</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0971-6203 |
ispartof | Journal of medical physics, 2013-04, Vol.38 (2), p.82-86 |
issn | 0971-6203 1998-3913 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3683305 |
source | Open Access: PubMed Central; Medknow Open Access Medical Journals; Publicly Available Content (ProQuest); IngentaConnect Journals |
subjects | Nuclear medicine Original Software Studies |
title | Determination of square equivalent field for rectangular field in electron therapy |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T07%3A56%3A53IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Determination%20of%20square%20equivalent%20field%20for%20rectangular%20field%20in%20electron%20therapy&rft.jtitle=Journal%20of%20medical%20physics&rft.au=Tahmasebi%20Birgani,%20Mohammad&rft.date=2013-04-01&rft.volume=38&rft.issue=2&rft.spage=82&rft.epage=86&rft.pages=82-86&rft.issn=0971-6203&rft.eissn=1998-3913&rft_id=info:doi/10.4103/0971-6203.111317&rft_dat=%3Cgale_pubme%3EA330727857%3C/gale_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c540n-1524d9b264e109493a11fe61cf9206e3f43ccce84461e0963e90bb58f3b68e23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1353571333&rft_id=info:pmid/23776311&rft_galeid=A330727857&rfr_iscdi=true |