A comparison between the effects of simple and traction splints on pain intensity in patients with femur fractures

Fractures of femur are among the most important causes of mortality in musculoskeletal injuries. Owning to lack of adequate research to compare various techniques of fracture stabilization, there has not yet been an agreement over a protocol to utilize a specific type of splint for femoral fracture...

Full description

Saved in:
Bibliographic Details
Published in:Iranian journal of nursing and midwifery research 2012-11, Vol.17 (7), p.530-533
Main Authors: Irajpour, Alireza, Kaji, Nariman Sadeghi, Nazari, Fatemeh, Azizkhani, Reza, Zadeh, Akbar Hassan
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites
container_end_page 533
container_issue 7
container_start_page 530
container_title Iranian journal of nursing and midwifery research
container_volume 17
creator Irajpour, Alireza
Kaji, Nariman Sadeghi
Nazari, Fatemeh
Azizkhani, Reza
Zadeh, Akbar Hassan
description Fractures of femur are among the most important causes of mortality in musculoskeletal injuries. Owning to lack of adequate research to compare various techniques of fracture stabilization, there has not yet been an agreement over a protocol to utilize a specific type of splint for femoral fracture immobilization. This study was thus conducted to compare the effects of simple and traction splints on pain intensityimmediately after and at the 1(st), 6(th), and 12(th)h after splinting among patients with femur fracture in the centers affiliated to Isfahan University of Medical Sciences (Isfahan, Iran). This quasi-experimental study was performed on 32 patients with femur fractures. Prehospital emergency ambulances were divided into two groups of simple and traction splints using a table of random numbers. Continuous convenient sampling was employed in each group to use either a simple or a traction splint for the patients with femur fractures. Pain intensity of the patients was then measured by a visual analogue scale (VAS) immediately, 1 h, 6 h, and 12 h after splinting. The effects of the two techniques were finally compared. After splinting, pain intensity decreased significantly in both groups (P = 0.0001 in both groups). The reductions were significantly more in the traction splint group at the 1(st), 6(th)(P = 0.0001), and 12(th)h after splinting (P = 0.02) compared with the simple splint group. There was no significant difference in pain intensity immediately after splintingbetween the two groups (P = 0.441). The significant difference in pain reduction between the simple and traction splint groups at the 1(st), 6(th), and 12(th)h after splinting emphasizes the superiority of traction splints.
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3730458</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1418644748</sourcerecordid><originalsourceid>FETCH-LOGICAL-p1118-542f9db74919cc66aac09d0413c20a878200372a48295a383c70d5ccb80f2d233</originalsourceid><addsrcrecordid>eNpVUEtLxDAQDqK4y7p_QXL0UsirTXIRlsUXLHjRc0nTxI20aU1Sl_33priKzmUe38z3zcwZWBJCRFGWiJ2DJea0LCSqqgVYx_iOsjFJuGCXYEGoJKRCeAnCBuqhH1VwcfCwMelgjIdpb6Cx1ugU4WBhdP3YGah8C1NQOrncGsfO-Rn2cFTOw5wYH1065ihXkjMzenBpD63ppwDtPDkFE6_AhVVdNOuTX4HX-7uX7WOxe3542m52xYgxzmcwYmXbcCax1LqqlNJItohhqglSgguCEOVEMUFkqaigmqO21LoRyJKWULoCt9-849T0ptV5oaC6egyuV-FYD8rV_xHv9vXb8FlTThErRSa4ORGE4WMyMdW9i9p0nfJmmGKNGRYVY5zNrdd_tX5Ffh5NvwA5P33A</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1418644748</pqid></control><display><type>article</type><title>A comparison between the effects of simple and traction splints on pain intensity in patients with femur fractures</title><source>PubMed Central</source><creator>Irajpour, Alireza ; Kaji, Nariman Sadeghi ; Nazari, Fatemeh ; Azizkhani, Reza ; Zadeh, Akbar Hassan</creator><creatorcontrib>Irajpour, Alireza ; Kaji, Nariman Sadeghi ; Nazari, Fatemeh ; Azizkhani, Reza ; Zadeh, Akbar Hassan</creatorcontrib><description>Fractures of femur are among the most important causes of mortality in musculoskeletal injuries. Owning to lack of adequate research to compare various techniques of fracture stabilization, there has not yet been an agreement over a protocol to utilize a specific type of splint for femoral fracture immobilization. This study was thus conducted to compare the effects of simple and traction splints on pain intensityimmediately after and at the 1(st), 6(th), and 12(th)h after splinting among patients with femur fracture in the centers affiliated to Isfahan University of Medical Sciences (Isfahan, Iran). This quasi-experimental study was performed on 32 patients with femur fractures. Prehospital emergency ambulances were divided into two groups of simple and traction splints using a table of random numbers. Continuous convenient sampling was employed in each group to use either a simple or a traction splint for the patients with femur fractures. Pain intensity of the patients was then measured by a visual analogue scale (VAS) immediately, 1 h, 6 h, and 12 h after splinting. The effects of the two techniques were finally compared. After splinting, pain intensity decreased significantly in both groups (P = 0.0001 in both groups). The reductions were significantly more in the traction splint group at the 1(st), 6(th)(P = 0.0001), and 12(th)h after splinting (P = 0.02) compared with the simple splint group. There was no significant difference in pain intensity immediately after splintingbetween the two groups (P = 0.441). The significant difference in pain reduction between the simple and traction splint groups at the 1(st), 6(th), and 12(th)h after splinting emphasizes the superiority of traction splints.</description><identifier>ISSN: 1735-9066</identifier><identifier>EISSN: 2228-5504</identifier><identifier>PMID: 23922601</identifier><language>eng</language><publisher>India: Medknow Publications &amp; Media Pvt Ltd</publisher><subject>Original</subject><ispartof>Iranian journal of nursing and midwifery research, 2012-11, Vol.17 (7), p.530-533</ispartof><rights>Copyright: © Iranian Journal of Nursing and Midwifery Research 2012</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3730458/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC3730458/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/23922601$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Irajpour, Alireza</creatorcontrib><creatorcontrib>Kaji, Nariman Sadeghi</creatorcontrib><creatorcontrib>Nazari, Fatemeh</creatorcontrib><creatorcontrib>Azizkhani, Reza</creatorcontrib><creatorcontrib>Zadeh, Akbar Hassan</creatorcontrib><title>A comparison between the effects of simple and traction splints on pain intensity in patients with femur fractures</title><title>Iranian journal of nursing and midwifery research</title><addtitle>Iran J Nurs Midwifery Res</addtitle><description>Fractures of femur are among the most important causes of mortality in musculoskeletal injuries. Owning to lack of adequate research to compare various techniques of fracture stabilization, there has not yet been an agreement over a protocol to utilize a specific type of splint for femoral fracture immobilization. This study was thus conducted to compare the effects of simple and traction splints on pain intensityimmediately after and at the 1(st), 6(th), and 12(th)h after splinting among patients with femur fracture in the centers affiliated to Isfahan University of Medical Sciences (Isfahan, Iran). This quasi-experimental study was performed on 32 patients with femur fractures. Prehospital emergency ambulances were divided into two groups of simple and traction splints using a table of random numbers. Continuous convenient sampling was employed in each group to use either a simple or a traction splint for the patients with femur fractures. Pain intensity of the patients was then measured by a visual analogue scale (VAS) immediately, 1 h, 6 h, and 12 h after splinting. The effects of the two techniques were finally compared. After splinting, pain intensity decreased significantly in both groups (P = 0.0001 in both groups). The reductions were significantly more in the traction splint group at the 1(st), 6(th)(P = 0.0001), and 12(th)h after splinting (P = 0.02) compared with the simple splint group. There was no significant difference in pain intensity immediately after splintingbetween the two groups (P = 0.441). The significant difference in pain reduction between the simple and traction splint groups at the 1(st), 6(th), and 12(th)h after splinting emphasizes the superiority of traction splints.</description><subject>Original</subject><issn>1735-9066</issn><issn>2228-5504</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2012</creationdate><recordtype>article</recordtype><recordid>eNpVUEtLxDAQDqK4y7p_QXL0UsirTXIRlsUXLHjRc0nTxI20aU1Sl_33priKzmUe38z3zcwZWBJCRFGWiJ2DJea0LCSqqgVYx_iOsjFJuGCXYEGoJKRCeAnCBuqhH1VwcfCwMelgjIdpb6Cx1ugU4WBhdP3YGah8C1NQOrncGsfO-Rn2cFTOw5wYH1065ihXkjMzenBpD63ppwDtPDkFE6_AhVVdNOuTX4HX-7uX7WOxe3542m52xYgxzmcwYmXbcCax1LqqlNJItohhqglSgguCEOVEMUFkqaigmqO21LoRyJKWULoCt9-849T0ptV5oaC6egyuV-FYD8rV_xHv9vXb8FlTThErRSa4ORGE4WMyMdW9i9p0nfJmmGKNGRYVY5zNrdd_tX5Ffh5NvwA5P33A</recordid><startdate>201211</startdate><enddate>201211</enddate><creator>Irajpour, Alireza</creator><creator>Kaji, Nariman Sadeghi</creator><creator>Nazari, Fatemeh</creator><creator>Azizkhani, Reza</creator><creator>Zadeh, Akbar Hassan</creator><general>Medknow Publications &amp; Media Pvt Ltd</general><scope>NPM</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>201211</creationdate><title>A comparison between the effects of simple and traction splints on pain intensity in patients with femur fractures</title><author>Irajpour, Alireza ; Kaji, Nariman Sadeghi ; Nazari, Fatemeh ; Azizkhani, Reza ; Zadeh, Akbar Hassan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p1118-542f9db74919cc66aac09d0413c20a878200372a48295a383c70d5ccb80f2d233</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2012</creationdate><topic>Original</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Irajpour, Alireza</creatorcontrib><creatorcontrib>Kaji, Nariman Sadeghi</creatorcontrib><creatorcontrib>Nazari, Fatemeh</creatorcontrib><creatorcontrib>Azizkhani, Reza</creatorcontrib><creatorcontrib>Zadeh, Akbar Hassan</creatorcontrib><collection>PubMed</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Iranian journal of nursing and midwifery research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Irajpour, Alireza</au><au>Kaji, Nariman Sadeghi</au><au>Nazari, Fatemeh</au><au>Azizkhani, Reza</au><au>Zadeh, Akbar Hassan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A comparison between the effects of simple and traction splints on pain intensity in patients with femur fractures</atitle><jtitle>Iranian journal of nursing and midwifery research</jtitle><addtitle>Iran J Nurs Midwifery Res</addtitle><date>2012-11</date><risdate>2012</risdate><volume>17</volume><issue>7</issue><spage>530</spage><epage>533</epage><pages>530-533</pages><issn>1735-9066</issn><eissn>2228-5504</eissn><abstract>Fractures of femur are among the most important causes of mortality in musculoskeletal injuries. Owning to lack of adequate research to compare various techniques of fracture stabilization, there has not yet been an agreement over a protocol to utilize a specific type of splint for femoral fracture immobilization. This study was thus conducted to compare the effects of simple and traction splints on pain intensityimmediately after and at the 1(st), 6(th), and 12(th)h after splinting among patients with femur fracture in the centers affiliated to Isfahan University of Medical Sciences (Isfahan, Iran). This quasi-experimental study was performed on 32 patients with femur fractures. Prehospital emergency ambulances were divided into two groups of simple and traction splints using a table of random numbers. Continuous convenient sampling was employed in each group to use either a simple or a traction splint for the patients with femur fractures. Pain intensity of the patients was then measured by a visual analogue scale (VAS) immediately, 1 h, 6 h, and 12 h after splinting. The effects of the two techniques were finally compared. After splinting, pain intensity decreased significantly in both groups (P = 0.0001 in both groups). The reductions were significantly more in the traction splint group at the 1(st), 6(th)(P = 0.0001), and 12(th)h after splinting (P = 0.02) compared with the simple splint group. There was no significant difference in pain intensity immediately after splintingbetween the two groups (P = 0.441). The significant difference in pain reduction between the simple and traction splint groups at the 1(st), 6(th), and 12(th)h after splinting emphasizes the superiority of traction splints.</abstract><cop>India</cop><pub>Medknow Publications &amp; Media Pvt Ltd</pub><pmid>23922601</pmid><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1735-9066
ispartof Iranian journal of nursing and midwifery research, 2012-11, Vol.17 (7), p.530-533
issn 1735-9066
2228-5504
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_3730458
source PubMed Central
subjects Original
title A comparison between the effects of simple and traction splints on pain intensity in patients with femur fractures
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T14%3A52%3A15IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20comparison%20between%20the%20effects%20of%20simple%20and%20traction%20splints%20on%20pain%20intensity%20in%20patients%20with%20femur%20fractures&rft.jtitle=Iranian%20journal%20of%20nursing%20and%20midwifery%20research&rft.au=Irajpour,%20Alireza&rft.date=2012-11&rft.volume=17&rft.issue=7&rft.spage=530&rft.epage=533&rft.pages=530-533&rft.issn=1735-9066&rft.eissn=2228-5504&rft_id=info:doi/&rft_dat=%3Cproquest_pubme%3E1418644748%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-p1118-542f9db74919cc66aac09d0413c20a878200372a48295a383c70d5ccb80f2d233%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1418644748&rft_id=info:pmid/23922601&rfr_iscdi=true