Loading…
Point shear wave elastography method for assessing liver stiffness
AIM:To estimate the validity of the point shear-wave elastography method by evaluating its reproducibility and accuracy for assessing liver stiffness.METHODS:This was a single-center,cross-sectional study.Consecutive patients with chronic viral hepatitis scheduled for liver biopsy(LB)(Group 1)and he...
Saved in:
Published in: | World journal of gastroenterology : WJG 2014-04, Vol.20 (16), p.4787-4796 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c506t-2ecb21b286af9a92cf3acdea2da8b8b9cad374aaf72d2003c0b0bbd65775b13c3 |
---|---|
cites | |
container_end_page | 4796 |
container_issue | 16 |
container_start_page | 4787 |
container_title | World journal of gastroenterology : WJG |
container_volume | 20 |
creator | Ferraioli, Giovanna Tinelli, Carmine Lissandrin, Raffaella Zicchetti, Mabel Dal Bello, Barbara Filice, Gaetano Filice, Carlo |
description | AIM:To estimate the validity of the point shear-wave elastography method by evaluating its reproducibility and accuracy for assessing liver stiffness.METHODS:This was a single-center,cross-sectional study.Consecutive patients with chronic viral hepatitis scheduled for liver biopsy(LB)(Group 1)and healthy volunteers(Group 2)were studied.In each subject 10 consecutive point shear-wave elastography(PSWE)measurements were performed using the iU22 ultrasound system(Philips Medical Systems,Bothell,WA,United States).Patients in Group 1 underwent PSWE,transient elastography(TE)using FibroScan(Echosens,Paris,France)and ultrasound-assisted LB.For the assessment of PSWE reproducibility two expert raters(rater 1 and rater 2)independently performed the examinations.The performance of PSWE was compared to that of TE using LB as a reference standard.Fibrosis was staged according to the METAVIR scoring system.Receiver operating characteristic curve analyses were performed to calculate the area under the receiver operating characteristic curve(AUC)for F≥2,F≥3and F=4.The intraobserver and interobserver reproducibility of PSWE were assessed by calculating Lin’s concordance correlation coefficient.RESULTS:To assess the performance of PSWE,134consecutive patients in Group 1 were studied.The median values of PSWE and TE(in kilopascals)were 4.7(IQR=3.8-5.4)and 5.5(IQR=4.7-6.5),respectively,in patients at the F0-F1 stage and 3.5(IQR=3.2-4.0)and 4.4(IQR=3.5-4.9),respectively,in the healthy volunteers in Group 2(P<10-5).In the univariate analysis,the PSWE and TE values showed a high correlation with the fibrosis stage;low correlations with the degree of necroinflammation,aspartate aminotransferase and gamma-glutamyl transferase(GGT);and a moderate negative correlation with the platelet count.A multiple regression analysis confirmed the correlations of both PSWE and TE with fibrosis stage and GGT but not with any other variables.The following AUC values were found:0.80(0.71-0.87)for PSWE and 0.82(0.73-0.89)for TE(P=0.42);0.88(0.80-0.94)for PSWE and 0.95(0.88-0.98)for TE(P=0.06);and 0.95(0.89-0.99)for PSWE and 0.92(0.85-0.97)for TE(P=0.30)for F≥2,F≥3 and F=4,respectively.To assess PSWE reproducibility,116 subjects were studied,including 47consecutive patients scheduled for LB(Group 1)and 69 consecutive healthy volunteers(Group 2).The intraobserver agreement ranged from 0.83(95%CI:0.79-0.88)to 0.96(95%CI:0.95-0.97)for rater 1 and from 0.84(95%CI:0.79-0.88)to 0.96(95%CI:0.95-0.97)fo |
doi_str_mv | 10.3748/wjg.v20.i16.4787 |
format | article |
fullrecord | <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4000517</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>90888889504849524954485152</cqvip_id><sourcerecordid>24782633</sourcerecordid><originalsourceid>FETCH-LOGICAL-c506t-2ecb21b286af9a92cf3acdea2da8b8b9cad374aaf72d2003c0b0bbd65775b13c3</originalsourceid><addsrcrecordid>eNpVkFtLJDEQhcPiso6Xd5-k_0C3lUqnk34RdNhdBcF92H0OlXT6IjPdY9KO-O83g-OgBUVB6pxT5GPsgkMhVKmvXp-6YotQDLwqSqXVN7ZA5HWOuoQjtuAAKq8FqmN2EuMTAAoh8Qc7xiTGSogFu_0zDeOcxd5TyF5p6zO_ojhPXaBN_5at_dxPTdZOIaMYfYzD2GWrYetDFuehbcf0dMa-t7SK_nw_T9m_Xz__Lu_yh8ff98ubh9xJqOYcvbPILeqK2ppqdK0g13jChrTVtnbUpD8RtQobBBAOLFjbVFIpablw4pRdv-duXuzaN86Pc6CV2YRhTeHNTDSYr5tx6E03bU0JAJKrFADvAS5MMQbfHrwczI6nSTxN4mkST7PjmSyXn28eDB8Ak0DsM_tp7J4TnoOmBr2rWkKpy1pi6rLUkksU_wENBYT8</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Point shear wave elastography method for assessing liver stiffness</title><source>PubMed Central</source><creator>Ferraioli, Giovanna ; Tinelli, Carmine ; Lissandrin, Raffaella ; Zicchetti, Mabel ; Dal Bello, Barbara ; Filice, Gaetano ; Filice, Carlo</creator><creatorcontrib>Ferraioli, Giovanna ; Tinelli, Carmine ; Lissandrin, Raffaella ; Zicchetti, Mabel ; Dal Bello, Barbara ; Filice, Gaetano ; Filice, Carlo</creatorcontrib><description>AIM:To estimate the validity of the point shear-wave elastography method by evaluating its reproducibility and accuracy for assessing liver stiffness.METHODS:This was a single-center,cross-sectional study.Consecutive patients with chronic viral hepatitis scheduled for liver biopsy(LB)(Group 1)and healthy volunteers(Group 2)were studied.In each subject 10 consecutive point shear-wave elastography(PSWE)measurements were performed using the iU22 ultrasound system(Philips Medical Systems,Bothell,WA,United States).Patients in Group 1 underwent PSWE,transient elastography(TE)using FibroScan(Echosens,Paris,France)and ultrasound-assisted LB.For the assessment of PSWE reproducibility two expert raters(rater 1 and rater 2)independently performed the examinations.The performance of PSWE was compared to that of TE using LB as a reference standard.Fibrosis was staged according to the METAVIR scoring system.Receiver operating characteristic curve analyses were performed to calculate the area under the receiver operating characteristic curve(AUC)for F≥2,F≥3and F=4.The intraobserver and interobserver reproducibility of PSWE were assessed by calculating Lin’s concordance correlation coefficient.RESULTS:To assess the performance of PSWE,134consecutive patients in Group 1 were studied.The median values of PSWE and TE(in kilopascals)were 4.7(IQR=3.8-5.4)and 5.5(IQR=4.7-6.5),respectively,in patients at the F0-F1 stage and 3.5(IQR=3.2-4.0)and 4.4(IQR=3.5-4.9),respectively,in the healthy volunteers in Group 2(P&lt;10-5).In the univariate analysis,the PSWE and TE values showed a high correlation with the fibrosis stage;low correlations with the degree of necroinflammation,aspartate aminotransferase and gamma-glutamyl transferase(GGT);and a moderate negative correlation with the platelet count.A multiple regression analysis confirmed the correlations of both PSWE and TE with fibrosis stage and GGT but not with any other variables.The following AUC values were found:0.80(0.71-0.87)for PSWE and 0.82(0.73-0.89)for TE(P=0.42);0.88(0.80-0.94)for PSWE and 0.95(0.88-0.98)for TE(P=0.06);and 0.95(0.89-0.99)for PSWE and 0.92(0.85-0.97)for TE(P=0.30)for F≥2,F≥3 and F=4,respectively.To assess PSWE reproducibility,116 subjects were studied,including 47consecutive patients scheduled for LB(Group 1)and 69 consecutive healthy volunteers(Group 2).The intraobserver agreement ranged from 0.83(95%CI:0.79-0.88)to 0.96(95%CI:0.95-0.97)for rater 1 and from 0.84(95%CI:0.79-0.88)to 0.96(95%CI:0.95-0.97)for rater 2.The interobserver agreement yielded values from0.83(95%CI:0.78-0.88)to 0.93(95%CI:0.91-0.95).CONCLUSION:PSWE is a reproducible method for assessing liver stiffness,and it compares with TE.Compared with patients with nonsignificant fibrosis,healthy volunteers showed significantly lower values.</description><identifier>ISSN: 1007-9327</identifier><identifier>EISSN: 2219-2840</identifier><identifier>DOI: 10.3748/wjg.v20.i16.4787</identifier><identifier>PMID: 24782633</identifier><language>eng</language><publisher>United States: Baishideng Publishing Group Co., Limited</publisher><subject>Adult ; Area Under Curve ; Biopsy ; Case-Control Studies ; Chronic ; Cross-Sectional Studies ; Elasticity ; Elasticity Imaging Techniques - methods ; Female ; fibrosi ; hepatitis ; Hepatitis C, Chronic - diagnostic imaging ; Hepatitis C, Chronic - pathology ; Humans ; Italy ; Liver ; Liver - diagnostic imaging ; Liver - pathology ; Liver Cirrhosis - diagnostic imaging ; Liver Cirrhosis - pathology ; Liver Cirrhosis - virology ; Male ; Middle Aged ; Observational Study ; Observer Variation ; Predictive Value of Tests ; Reproducibility of Results ; ROC Curve ; Severity of Illness Index ; viral</subject><ispartof>World journal of gastroenterology : WJG, 2014-04, Vol.20 (16), p.4787-4796</ispartof><rights>2014 Baishideng Publishing Group Co., Limited. All rights reserved. 2014</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c506t-2ecb21b286af9a92cf3acdea2da8b8b9cad374aaf72d2003c0b0bbd65775b13c3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/84123X/84123X.jpg</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4000517/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4000517/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,724,777,781,882,27905,27906,53772,53774</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/24782633$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Ferraioli, Giovanna</creatorcontrib><creatorcontrib>Tinelli, Carmine</creatorcontrib><creatorcontrib>Lissandrin, Raffaella</creatorcontrib><creatorcontrib>Zicchetti, Mabel</creatorcontrib><creatorcontrib>Dal Bello, Barbara</creatorcontrib><creatorcontrib>Filice, Gaetano</creatorcontrib><creatorcontrib>Filice, Carlo</creatorcontrib><title>Point shear wave elastography method for assessing liver stiffness</title><title>World journal of gastroenterology : WJG</title><addtitle>World Journal of Gastroenterology</addtitle><description>AIM:To estimate the validity of the point shear-wave elastography method by evaluating its reproducibility and accuracy for assessing liver stiffness.METHODS:This was a single-center,cross-sectional study.Consecutive patients with chronic viral hepatitis scheduled for liver biopsy(LB)(Group 1)and healthy volunteers(Group 2)were studied.In each subject 10 consecutive point shear-wave elastography(PSWE)measurements were performed using the iU22 ultrasound system(Philips Medical Systems,Bothell,WA,United States).Patients in Group 1 underwent PSWE,transient elastography(TE)using FibroScan(Echosens,Paris,France)and ultrasound-assisted LB.For the assessment of PSWE reproducibility two expert raters(rater 1 and rater 2)independently performed the examinations.The performance of PSWE was compared to that of TE using LB as a reference standard.Fibrosis was staged according to the METAVIR scoring system.Receiver operating characteristic curve analyses were performed to calculate the area under the receiver operating characteristic curve(AUC)for F≥2,F≥3and F=4.The intraobserver and interobserver reproducibility of PSWE were assessed by calculating Lin’s concordance correlation coefficient.RESULTS:To assess the performance of PSWE,134consecutive patients in Group 1 were studied.The median values of PSWE and TE(in kilopascals)were 4.7(IQR=3.8-5.4)and 5.5(IQR=4.7-6.5),respectively,in patients at the F0-F1 stage and 3.5(IQR=3.2-4.0)and 4.4(IQR=3.5-4.9),respectively,in the healthy volunteers in Group 2(P&lt;10-5).In the univariate analysis,the PSWE and TE values showed a high correlation with the fibrosis stage;low correlations with the degree of necroinflammation,aspartate aminotransferase and gamma-glutamyl transferase(GGT);and a moderate negative correlation with the platelet count.A multiple regression analysis confirmed the correlations of both PSWE and TE with fibrosis stage and GGT but not with any other variables.The following AUC values were found:0.80(0.71-0.87)for PSWE and 0.82(0.73-0.89)for TE(P=0.42);0.88(0.80-0.94)for PSWE and 0.95(0.88-0.98)for TE(P=0.06);and 0.95(0.89-0.99)for PSWE and 0.92(0.85-0.97)for TE(P=0.30)for F≥2,F≥3 and F=4,respectively.To assess PSWE reproducibility,116 subjects were studied,including 47consecutive patients scheduled for LB(Group 1)and 69 consecutive healthy volunteers(Group 2).The intraobserver agreement ranged from 0.83(95%CI:0.79-0.88)to 0.96(95%CI:0.95-0.97)for rater 1 and from 0.84(95%CI:0.79-0.88)to 0.96(95%CI:0.95-0.97)for rater 2.The interobserver agreement yielded values from0.83(95%CI:0.78-0.88)to 0.93(95%CI:0.91-0.95).CONCLUSION:PSWE is a reproducible method for assessing liver stiffness,and it compares with TE.Compared with patients with nonsignificant fibrosis,healthy volunteers showed significantly lower values.</description><subject>Adult</subject><subject>Area Under Curve</subject><subject>Biopsy</subject><subject>Case-Control Studies</subject><subject>Chronic</subject><subject>Cross-Sectional Studies</subject><subject>Elasticity</subject><subject>Elasticity Imaging Techniques - methods</subject><subject>Female</subject><subject>fibrosi</subject><subject>hepatitis</subject><subject>Hepatitis C, Chronic - diagnostic imaging</subject><subject>Hepatitis C, Chronic - pathology</subject><subject>Humans</subject><subject>Italy</subject><subject>Liver</subject><subject>Liver - diagnostic imaging</subject><subject>Liver - pathology</subject><subject>Liver Cirrhosis - diagnostic imaging</subject><subject>Liver Cirrhosis - pathology</subject><subject>Liver Cirrhosis - virology</subject><subject>Male</subject><subject>Middle Aged</subject><subject>Observational Study</subject><subject>Observer Variation</subject><subject>Predictive Value of Tests</subject><subject>Reproducibility of Results</subject><subject>ROC Curve</subject><subject>Severity of Illness Index</subject><subject>viral</subject><issn>1007-9327</issn><issn>2219-2840</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNpVkFtLJDEQhcPiso6Xd5-k_0C3lUqnk34RdNhdBcF92H0OlXT6IjPdY9KO-O83g-OgBUVB6pxT5GPsgkMhVKmvXp-6YotQDLwqSqXVN7ZA5HWOuoQjtuAAKq8FqmN2EuMTAAoh8Qc7xiTGSogFu_0zDeOcxd5TyF5p6zO_ojhPXaBN_5at_dxPTdZOIaMYfYzD2GWrYetDFuehbcf0dMa-t7SK_nw_T9m_Xz__Lu_yh8ff98ubh9xJqOYcvbPILeqK2ppqdK0g13jChrTVtnbUpD8RtQobBBAOLFjbVFIpablw4pRdv-duXuzaN86Pc6CV2YRhTeHNTDSYr5tx6E03bU0JAJKrFADvAS5MMQbfHrwczI6nSTxN4mkST7PjmSyXn28eDB8Ak0DsM_tp7J4TnoOmBr2rWkKpy1pi6rLUkksU_wENBYT8</recordid><startdate>20140428</startdate><enddate>20140428</enddate><creator>Ferraioli, Giovanna</creator><creator>Tinelli, Carmine</creator><creator>Lissandrin, Raffaella</creator><creator>Zicchetti, Mabel</creator><creator>Dal Bello, Barbara</creator><creator>Filice, Gaetano</creator><creator>Filice, Carlo</creator><general>Baishideng Publishing Group Co., Limited</general><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>W91</scope><scope>~WA</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>5PM</scope></search><sort><creationdate>20140428</creationdate><title>Point shear wave elastography method for assessing liver stiffness</title><author>Ferraioli, Giovanna ; Tinelli, Carmine ; Lissandrin, Raffaella ; Zicchetti, Mabel ; Dal Bello, Barbara ; Filice, Gaetano ; Filice, Carlo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c506t-2ecb21b286af9a92cf3acdea2da8b8b9cad374aaf72d2003c0b0bbd65775b13c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Adult</topic><topic>Area Under Curve</topic><topic>Biopsy</topic><topic>Case-Control Studies</topic><topic>Chronic</topic><topic>Cross-Sectional Studies</topic><topic>Elasticity</topic><topic>Elasticity Imaging Techniques - methods</topic><topic>Female</topic><topic>fibrosi</topic><topic>hepatitis</topic><topic>Hepatitis C, Chronic - diagnostic imaging</topic><topic>Hepatitis C, Chronic - pathology</topic><topic>Humans</topic><topic>Italy</topic><topic>Liver</topic><topic>Liver - diagnostic imaging</topic><topic>Liver - pathology</topic><topic>Liver Cirrhosis - diagnostic imaging</topic><topic>Liver Cirrhosis - pathology</topic><topic>Liver Cirrhosis - virology</topic><topic>Male</topic><topic>Middle Aged</topic><topic>Observational Study</topic><topic>Observer Variation</topic><topic>Predictive Value of Tests</topic><topic>Reproducibility of Results</topic><topic>ROC Curve</topic><topic>Severity of Illness Index</topic><topic>viral</topic><toplevel>online_resources</toplevel><creatorcontrib>Ferraioli, Giovanna</creatorcontrib><creatorcontrib>Tinelli, Carmine</creatorcontrib><creatorcontrib>Lissandrin, Raffaella</creatorcontrib><creatorcontrib>Zicchetti, Mabel</creatorcontrib><creatorcontrib>Dal Bello, Barbara</creatorcontrib><creatorcontrib>Filice, Gaetano</creatorcontrib><creatorcontrib>Filice, Carlo</creatorcontrib><collection>维普_期刊</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库-医药卫生</collection><collection>中文科技期刊数据库- 镜像站点</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>World journal of gastroenterology : WJG</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ferraioli, Giovanna</au><au>Tinelli, Carmine</au><au>Lissandrin, Raffaella</au><au>Zicchetti, Mabel</au><au>Dal Bello, Barbara</au><au>Filice, Gaetano</au><au>Filice, Carlo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Point shear wave elastography method for assessing liver stiffness</atitle><jtitle>World journal of gastroenterology : WJG</jtitle><addtitle>World Journal of Gastroenterology</addtitle><date>2014-04-28</date><risdate>2014</risdate><volume>20</volume><issue>16</issue><spage>4787</spage><epage>4796</epage><pages>4787-4796</pages><issn>1007-9327</issn><eissn>2219-2840</eissn><abstract>AIM:To estimate the validity of the point shear-wave elastography method by evaluating its reproducibility and accuracy for assessing liver stiffness.METHODS:This was a single-center,cross-sectional study.Consecutive patients with chronic viral hepatitis scheduled for liver biopsy(LB)(Group 1)and healthy volunteers(Group 2)were studied.In each subject 10 consecutive point shear-wave elastography(PSWE)measurements were performed using the iU22 ultrasound system(Philips Medical Systems,Bothell,WA,United States).Patients in Group 1 underwent PSWE,transient elastography(TE)using FibroScan(Echosens,Paris,France)and ultrasound-assisted LB.For the assessment of PSWE reproducibility two expert raters(rater 1 and rater 2)independently performed the examinations.The performance of PSWE was compared to that of TE using LB as a reference standard.Fibrosis was staged according to the METAVIR scoring system.Receiver operating characteristic curve analyses were performed to calculate the area under the receiver operating characteristic curve(AUC)for F≥2,F≥3and F=4.The intraobserver and interobserver reproducibility of PSWE were assessed by calculating Lin’s concordance correlation coefficient.RESULTS:To assess the performance of PSWE,134consecutive patients in Group 1 were studied.The median values of PSWE and TE(in kilopascals)were 4.7(IQR=3.8-5.4)and 5.5(IQR=4.7-6.5),respectively,in patients at the F0-F1 stage and 3.5(IQR=3.2-4.0)and 4.4(IQR=3.5-4.9),respectively,in the healthy volunteers in Group 2(P&lt;10-5).In the univariate analysis,the PSWE and TE values showed a high correlation with the fibrosis stage;low correlations with the degree of necroinflammation,aspartate aminotransferase and gamma-glutamyl transferase(GGT);and a moderate negative correlation with the platelet count.A multiple regression analysis confirmed the correlations of both PSWE and TE with fibrosis stage and GGT but not with any other variables.The following AUC values were found:0.80(0.71-0.87)for PSWE and 0.82(0.73-0.89)for TE(P=0.42);0.88(0.80-0.94)for PSWE and 0.95(0.88-0.98)for TE(P=0.06);and 0.95(0.89-0.99)for PSWE and 0.92(0.85-0.97)for TE(P=0.30)for F≥2,F≥3 and F=4,respectively.To assess PSWE reproducibility,116 subjects were studied,including 47consecutive patients scheduled for LB(Group 1)and 69 consecutive healthy volunteers(Group 2).The intraobserver agreement ranged from 0.83(95%CI:0.79-0.88)to 0.96(95%CI:0.95-0.97)for rater 1 and from 0.84(95%CI:0.79-0.88)to 0.96(95%CI:0.95-0.97)for rater 2.The interobserver agreement yielded values from0.83(95%CI:0.78-0.88)to 0.93(95%CI:0.91-0.95).CONCLUSION:PSWE is a reproducible method for assessing liver stiffness,and it compares with TE.Compared with patients with nonsignificant fibrosis,healthy volunteers showed significantly lower values.</abstract><cop>United States</cop><pub>Baishideng Publishing Group Co., Limited</pub><pmid>24782633</pmid><doi>10.3748/wjg.v20.i16.4787</doi><tpages>10</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1007-9327 |
ispartof | World journal of gastroenterology : WJG, 2014-04, Vol.20 (16), p.4787-4796 |
issn | 1007-9327 2219-2840 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4000517 |
source | PubMed Central |
subjects | Adult Area Under Curve Biopsy Case-Control Studies Chronic Cross-Sectional Studies Elasticity Elasticity Imaging Techniques - methods Female fibrosi hepatitis Hepatitis C, Chronic - diagnostic imaging Hepatitis C, Chronic - pathology Humans Italy Liver Liver - diagnostic imaging Liver - pathology Liver Cirrhosis - diagnostic imaging Liver Cirrhosis - pathology Liver Cirrhosis - virology Male Middle Aged Observational Study Observer Variation Predictive Value of Tests Reproducibility of Results ROC Curve Severity of Illness Index viral |
title | Point shear wave elastography method for assessing liver stiffness |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-18T21%3A16%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Point%20shear%20wave%20elastography%20method%20for%20assessing%20liver%20stiffness&rft.jtitle=World%20journal%20of%20gastroenterology%20:%20WJG&rft.au=Ferraioli,%20Giovanna&rft.date=2014-04-28&rft.volume=20&rft.issue=16&rft.spage=4787&rft.epage=4796&rft.pages=4787-4796&rft.issn=1007-9327&rft.eissn=2219-2840&rft_id=info:doi/10.3748/wjg.v20.i16.4787&rft_dat=%3Cpubmed_cross%3E24782633%3C/pubmed_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c506t-2ecb21b286af9a92cf3acdea2da8b8b9cad374aaf72d2003c0b0bbd65775b13c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/24782633&rft_cqvip_id=90888889504849524954485152&rfr_iscdi=true |