Loading…
Minimizing projection artifacts for accurate presentation of choroidal neovascularization in OCT micro-angiography
Current optical coherence tomography (OCT) based micro-angiography is prone to a projection (or tailing) effect due to the high scattering property of blood within overlying patent vessels, creating artifacts that interfere with the interpretation of retinal angiographic results. In this work, the p...
Saved in:
Published in: | Biomedical optics express 2015-10, Vol.6 (10), p.4130-4143 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c450t-76104ec4cb3e44c6840a8a4da99959f47d4fec48cdaf0ccf34b841b92e0ab8023 |
---|---|
cites | cdi_FETCH-LOGICAL-c450t-76104ec4cb3e44c6840a8a4da99959f47d4fec48cdaf0ccf34b841b92e0ab8023 |
container_end_page | 4143 |
container_issue | 10 |
container_start_page | 4130 |
container_title | Biomedical optics express |
container_volume | 6 |
creator | Zhang, Anqi Zhang, Qinqin Wang, Ruikang K |
description | Current optical coherence tomography (OCT) based micro-angiography is prone to a projection (or tailing) effect due to the high scattering property of blood within overlying patent vessels, creating artifacts that interfere with the interpretation of retinal angiographic results. In this work, the projection effect in OCT micro-angiography is examined and its causality is explained by strong light scattering and photon propagation within blood. A simple practical approach is then introduced to minimize these artifacts presented in the outer retinal avascular space, especially useful for examining clinical cases with choroidal neovascularization (CNV). Demonstrated through in-vivo human posterior eye imaging of healthy and CNV subjects, the proposed method is shown effective to eliminate the projection artifacts in outer retinal space of OCT micro-angiography, resulting in better visualization of the pathological neovascularization when compared with the current common approaches. In addition, it is also shown that the proposed method is applicable to minimize the projection artifacts appearing in deep retinal layers. |
doi_str_mv | 10.1364/BOE.6.004130 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4605069</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1727992315</sourcerecordid><originalsourceid>FETCH-LOGICAL-c450t-76104ec4cb3e44c6840a8a4da99959f47d4fec48cdaf0ccf34b841b92e0ab8023</originalsourceid><addsrcrecordid>eNpVkUFv2zAMhYVhRRN0ufU8-LjDnFI2LduXAVvQbQU65NKeBVqWEgW2lUp2gfTXV1vSIuOFBN6HRxKPsWsOS54LvPmxvl2KJQDyHD6wecYLkZZQFR_P5hlbhLCDWIgl5NUlm2WiABQC5sz_sYPt7YsdNsneu51Wo3VDQn60htQYEuN8QkpNnkYdCR30MNI_xplEbZ13tqUuGbR7pqCmjrx9Oep2SNarh6S3yruUho11G0_77eETuzDUBb049Sv2-PP2YfU7vV__ult9v08VFjCmpeCAWqFqco2oRIVAFWFLdV0XtcGyRRPlSrVkQCmTY1Mhb-pMAzUVZPkV-3b03U9Nr1sVD_fUyb23PfmDdGTl_8pgt3LjniUKKEDU0eDLycC7p0mHUfY2KN11FL-dguRlVtZ1lvMiol-PaPw1BK_N-xoO8m9SMiYlhTwmFfHP56e9w2-55K8xdJJ-</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1727992315</pqid></control><display><type>article</type><title>Minimizing projection artifacts for accurate presentation of choroidal neovascularization in OCT micro-angiography</title><source>PubMed Central</source><source>EZB Electronic Journals Library</source><creator>Zhang, Anqi ; Zhang, Qinqin ; Wang, Ruikang K</creator><creatorcontrib>Zhang, Anqi ; Zhang, Qinqin ; Wang, Ruikang K</creatorcontrib><description>Current optical coherence tomography (OCT) based micro-angiography is prone to a projection (or tailing) effect due to the high scattering property of blood within overlying patent vessels, creating artifacts that interfere with the interpretation of retinal angiographic results. In this work, the projection effect in OCT micro-angiography is examined and its causality is explained by strong light scattering and photon propagation within blood. A simple practical approach is then introduced to minimize these artifacts presented in the outer retinal avascular space, especially useful for examining clinical cases with choroidal neovascularization (CNV). Demonstrated through in-vivo human posterior eye imaging of healthy and CNV subjects, the proposed method is shown effective to eliminate the projection artifacts in outer retinal space of OCT micro-angiography, resulting in better visualization of the pathological neovascularization when compared with the current common approaches. In addition, it is also shown that the proposed method is applicable to minimize the projection artifacts appearing in deep retinal layers.</description><identifier>ISSN: 2156-7085</identifier><identifier>EISSN: 2156-7085</identifier><identifier>DOI: 10.1364/BOE.6.004130</identifier><identifier>PMID: 26504660</identifier><language>eng</language><publisher>United States: Optical Society of America</publisher><ispartof>Biomedical optics express, 2015-10, Vol.6 (10), p.4130-4143</ispartof><rights>2015 Optical Society of America 2015 Optical Society of America</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c450t-76104ec4cb3e44c6840a8a4da99959f47d4fec48cdaf0ccf34b841b92e0ab8023</citedby><cites>FETCH-LOGICAL-c450t-76104ec4cb3e44c6840a8a4da99959f47d4fec48cdaf0ccf34b841b92e0ab8023</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4605069/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4605069/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,723,776,780,881,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26504660$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zhang, Anqi</creatorcontrib><creatorcontrib>Zhang, Qinqin</creatorcontrib><creatorcontrib>Wang, Ruikang K</creatorcontrib><title>Minimizing projection artifacts for accurate presentation of choroidal neovascularization in OCT micro-angiography</title><title>Biomedical optics express</title><addtitle>Biomed Opt Express</addtitle><description>Current optical coherence tomography (OCT) based micro-angiography is prone to a projection (or tailing) effect due to the high scattering property of blood within overlying patent vessels, creating artifacts that interfere with the interpretation of retinal angiographic results. In this work, the projection effect in OCT micro-angiography is examined and its causality is explained by strong light scattering and photon propagation within blood. A simple practical approach is then introduced to minimize these artifacts presented in the outer retinal avascular space, especially useful for examining clinical cases with choroidal neovascularization (CNV). Demonstrated through in-vivo human posterior eye imaging of healthy and CNV subjects, the proposed method is shown effective to eliminate the projection artifacts in outer retinal space of OCT micro-angiography, resulting in better visualization of the pathological neovascularization when compared with the current common approaches. In addition, it is also shown that the proposed method is applicable to minimize the projection artifacts appearing in deep retinal layers.</description><issn>2156-7085</issn><issn>2156-7085</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNpVkUFv2zAMhYVhRRN0ufU8-LjDnFI2LduXAVvQbQU65NKeBVqWEgW2lUp2gfTXV1vSIuOFBN6HRxKPsWsOS54LvPmxvl2KJQDyHD6wecYLkZZQFR_P5hlbhLCDWIgl5NUlm2WiABQC5sz_sYPt7YsdNsneu51Wo3VDQn60htQYEuN8QkpNnkYdCR30MNI_xplEbZ13tqUuGbR7pqCmjrx9Oep2SNarh6S3yruUho11G0_77eETuzDUBb049Sv2-PP2YfU7vV__ult9v08VFjCmpeCAWqFqco2oRIVAFWFLdV0XtcGyRRPlSrVkQCmTY1Mhb-pMAzUVZPkV-3b03U9Nr1sVD_fUyb23PfmDdGTl_8pgt3LjniUKKEDU0eDLycC7p0mHUfY2KN11FL-dguRlVtZ1lvMiol-PaPw1BK_N-xoO8m9SMiYlhTwmFfHP56e9w2-55K8xdJJ-</recordid><startdate>20151001</startdate><enddate>20151001</enddate><creator>Zhang, Anqi</creator><creator>Zhang, Qinqin</creator><creator>Wang, Ruikang K</creator><general>Optical Society of America</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20151001</creationdate><title>Minimizing projection artifacts for accurate presentation of choroidal neovascularization in OCT micro-angiography</title><author>Zhang, Anqi ; Zhang, Qinqin ; Wang, Ruikang K</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c450t-76104ec4cb3e44c6840a8a4da99959f47d4fec48cdaf0ccf34b841b92e0ab8023</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhang, Anqi</creatorcontrib><creatorcontrib>Zhang, Qinqin</creatorcontrib><creatorcontrib>Wang, Ruikang K</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Biomedical optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhang, Anqi</au><au>Zhang, Qinqin</au><au>Wang, Ruikang K</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Minimizing projection artifacts for accurate presentation of choroidal neovascularization in OCT micro-angiography</atitle><jtitle>Biomedical optics express</jtitle><addtitle>Biomed Opt Express</addtitle><date>2015-10-01</date><risdate>2015</risdate><volume>6</volume><issue>10</issue><spage>4130</spage><epage>4143</epage><pages>4130-4143</pages><issn>2156-7085</issn><eissn>2156-7085</eissn><abstract>Current optical coherence tomography (OCT) based micro-angiography is prone to a projection (or tailing) effect due to the high scattering property of blood within overlying patent vessels, creating artifacts that interfere with the interpretation of retinal angiographic results. In this work, the projection effect in OCT micro-angiography is examined and its causality is explained by strong light scattering and photon propagation within blood. A simple practical approach is then introduced to minimize these artifacts presented in the outer retinal avascular space, especially useful for examining clinical cases with choroidal neovascularization (CNV). Demonstrated through in-vivo human posterior eye imaging of healthy and CNV subjects, the proposed method is shown effective to eliminate the projection artifacts in outer retinal space of OCT micro-angiography, resulting in better visualization of the pathological neovascularization when compared with the current common approaches. In addition, it is also shown that the proposed method is applicable to minimize the projection artifacts appearing in deep retinal layers.</abstract><cop>United States</cop><pub>Optical Society of America</pub><pmid>26504660</pmid><doi>10.1364/BOE.6.004130</doi><tpages>14</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2156-7085 |
ispartof | Biomedical optics express, 2015-10, Vol.6 (10), p.4130-4143 |
issn | 2156-7085 2156-7085 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4605069 |
source | PubMed Central; EZB Electronic Journals Library |
title | Minimizing projection artifacts for accurate presentation of choroidal neovascularization in OCT micro-angiography |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T23%3A58%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Minimizing%20projection%20artifacts%20for%20accurate%20presentation%20of%20choroidal%20neovascularization%20in%20OCT%20micro-angiography&rft.jtitle=Biomedical%20optics%20express&rft.au=Zhang,%20Anqi&rft.date=2015-10-01&rft.volume=6&rft.issue=10&rft.spage=4130&rft.epage=4143&rft.pages=4130-4143&rft.issn=2156-7085&rft.eissn=2156-7085&rft_id=info:doi/10.1364/BOE.6.004130&rft_dat=%3Cproquest_pubme%3E1727992315%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c450t-76104ec4cb3e44c6840a8a4da99959f47d4fec48cdaf0ccf34b841b92e0ab8023%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1727992315&rft_id=info:pmid/26504660&rfr_iscdi=true |