Minimizing projection artifacts for accurate presentation of choroidal neovascularization in OCT micro-angiography

Current optical coherence tomography (OCT) based micro-angiography is prone to a projection (or tailing) effect due to the high scattering property of blood within overlying patent vessels, creating artifacts that interfere with the interpretation of retinal angiographic results. In this work, the p...

Full description

Saved in:
Bibliographic Details
Published in:Biomedical optics express 2015-10, Vol.6 (10), p.4130-4143
Main Authors: Zhang, Anqi, Zhang, Qinqin, Wang, Ruikang K
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c450t-76104ec4cb3e44c6840a8a4da99959f47d4fec48cdaf0ccf34b841b92e0ab8023
cites cdi_FETCH-LOGICAL-c450t-76104ec4cb3e44c6840a8a4da99959f47d4fec48cdaf0ccf34b841b92e0ab8023
container_end_page 4143
container_issue 10
container_start_page 4130
container_title Biomedical optics express
container_volume 6
creator Zhang, Anqi
Zhang, Qinqin
Wang, Ruikang K
description Current optical coherence tomography (OCT) based micro-angiography is prone to a projection (or tailing) effect due to the high scattering property of blood within overlying patent vessels, creating artifacts that interfere with the interpretation of retinal angiographic results. In this work, the projection effect in OCT micro-angiography is examined and its causality is explained by strong light scattering and photon propagation within blood. A simple practical approach is then introduced to minimize these artifacts presented in the outer retinal avascular space, especially useful for examining clinical cases with choroidal neovascularization (CNV). Demonstrated through in-vivo human posterior eye imaging of healthy and CNV subjects, the proposed method is shown effective to eliminate the projection artifacts in outer retinal space of OCT micro-angiography, resulting in better visualization of the pathological neovascularization when compared with the current common approaches. In addition, it is also shown that the proposed method is applicable to minimize the projection artifacts appearing in deep retinal layers.
doi_str_mv 10.1364/BOE.6.004130
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4605069</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1727992315</sourcerecordid><originalsourceid>FETCH-LOGICAL-c450t-76104ec4cb3e44c6840a8a4da99959f47d4fec48cdaf0ccf34b841b92e0ab8023</originalsourceid><addsrcrecordid>eNpVkUFv2zAMhYVhRRN0ufU8-LjDnFI2LduXAVvQbQU65NKeBVqWEgW2lUp2gfTXV1vSIuOFBN6HRxKPsWsOS54LvPmxvl2KJQDyHD6wecYLkZZQFR_P5hlbhLCDWIgl5NUlm2WiABQC5sz_sYPt7YsdNsneu51Wo3VDQn60htQYEuN8QkpNnkYdCR30MNI_xplEbZ13tqUuGbR7pqCmjrx9Oep2SNarh6S3yruUho11G0_77eETuzDUBb049Sv2-PP2YfU7vV__ult9v08VFjCmpeCAWqFqco2oRIVAFWFLdV0XtcGyRRPlSrVkQCmTY1Mhb-pMAzUVZPkV-3b03U9Nr1sVD_fUyb23PfmDdGTl_8pgt3LjniUKKEDU0eDLycC7p0mHUfY2KN11FL-dguRlVtZ1lvMiol-PaPw1BK_N-xoO8m9SMiYlhTwmFfHP56e9w2-55K8xdJJ-</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1727992315</pqid></control><display><type>article</type><title>Minimizing projection artifacts for accurate presentation of choroidal neovascularization in OCT micro-angiography</title><source>PubMed Central</source><source>EZB Electronic Journals Library</source><creator>Zhang, Anqi ; Zhang, Qinqin ; Wang, Ruikang K</creator><creatorcontrib>Zhang, Anqi ; Zhang, Qinqin ; Wang, Ruikang K</creatorcontrib><description>Current optical coherence tomography (OCT) based micro-angiography is prone to a projection (or tailing) effect due to the high scattering property of blood within overlying patent vessels, creating artifacts that interfere with the interpretation of retinal angiographic results. In this work, the projection effect in OCT micro-angiography is examined and its causality is explained by strong light scattering and photon propagation within blood. A simple practical approach is then introduced to minimize these artifacts presented in the outer retinal avascular space, especially useful for examining clinical cases with choroidal neovascularization (CNV). Demonstrated through in-vivo human posterior eye imaging of healthy and CNV subjects, the proposed method is shown effective to eliminate the projection artifacts in outer retinal space of OCT micro-angiography, resulting in better visualization of the pathological neovascularization when compared with the current common approaches. In addition, it is also shown that the proposed method is applicable to minimize the projection artifacts appearing in deep retinal layers.</description><identifier>ISSN: 2156-7085</identifier><identifier>EISSN: 2156-7085</identifier><identifier>DOI: 10.1364/BOE.6.004130</identifier><identifier>PMID: 26504660</identifier><language>eng</language><publisher>United States: Optical Society of America</publisher><ispartof>Biomedical optics express, 2015-10, Vol.6 (10), p.4130-4143</ispartof><rights>2015 Optical Society of America 2015 Optical Society of America</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c450t-76104ec4cb3e44c6840a8a4da99959f47d4fec48cdaf0ccf34b841b92e0ab8023</citedby><cites>FETCH-LOGICAL-c450t-76104ec4cb3e44c6840a8a4da99959f47d4fec48cdaf0ccf34b841b92e0ab8023</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4605069/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC4605069/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,723,776,780,881,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26504660$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zhang, Anqi</creatorcontrib><creatorcontrib>Zhang, Qinqin</creatorcontrib><creatorcontrib>Wang, Ruikang K</creatorcontrib><title>Minimizing projection artifacts for accurate presentation of choroidal neovascularization in OCT micro-angiography</title><title>Biomedical optics express</title><addtitle>Biomed Opt Express</addtitle><description>Current optical coherence tomography (OCT) based micro-angiography is prone to a projection (or tailing) effect due to the high scattering property of blood within overlying patent vessels, creating artifacts that interfere with the interpretation of retinal angiographic results. In this work, the projection effect in OCT micro-angiography is examined and its causality is explained by strong light scattering and photon propagation within blood. A simple practical approach is then introduced to minimize these artifacts presented in the outer retinal avascular space, especially useful for examining clinical cases with choroidal neovascularization (CNV). Demonstrated through in-vivo human posterior eye imaging of healthy and CNV subjects, the proposed method is shown effective to eliminate the projection artifacts in outer retinal space of OCT micro-angiography, resulting in better visualization of the pathological neovascularization when compared with the current common approaches. In addition, it is also shown that the proposed method is applicable to minimize the projection artifacts appearing in deep retinal layers.</description><issn>2156-7085</issn><issn>2156-7085</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNpVkUFv2zAMhYVhRRN0ufU8-LjDnFI2LduXAVvQbQU65NKeBVqWEgW2lUp2gfTXV1vSIuOFBN6HRxKPsWsOS54LvPmxvl2KJQDyHD6wecYLkZZQFR_P5hlbhLCDWIgl5NUlm2WiABQC5sz_sYPt7YsdNsneu51Wo3VDQn60htQYEuN8QkpNnkYdCR30MNI_xplEbZ13tqUuGbR7pqCmjrx9Oep2SNarh6S3yruUho11G0_77eETuzDUBb049Sv2-PP2YfU7vV__ult9v08VFjCmpeCAWqFqco2oRIVAFWFLdV0XtcGyRRPlSrVkQCmTY1Mhb-pMAzUVZPkV-3b03U9Nr1sVD_fUyb23PfmDdGTl_8pgt3LjniUKKEDU0eDLycC7p0mHUfY2KN11FL-dguRlVtZ1lvMiol-PaPw1BK_N-xoO8m9SMiYlhTwmFfHP56e9w2-55K8xdJJ-</recordid><startdate>20151001</startdate><enddate>20151001</enddate><creator>Zhang, Anqi</creator><creator>Zhang, Qinqin</creator><creator>Wang, Ruikang K</creator><general>Optical Society of America</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20151001</creationdate><title>Minimizing projection artifacts for accurate presentation of choroidal neovascularization in OCT micro-angiography</title><author>Zhang, Anqi ; Zhang, Qinqin ; Wang, Ruikang K</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c450t-76104ec4cb3e44c6840a8a4da99959f47d4fec48cdaf0ccf34b841b92e0ab8023</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhang, Anqi</creatorcontrib><creatorcontrib>Zhang, Qinqin</creatorcontrib><creatorcontrib>Wang, Ruikang K</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Biomedical optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhang, Anqi</au><au>Zhang, Qinqin</au><au>Wang, Ruikang K</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Minimizing projection artifacts for accurate presentation of choroidal neovascularization in OCT micro-angiography</atitle><jtitle>Biomedical optics express</jtitle><addtitle>Biomed Opt Express</addtitle><date>2015-10-01</date><risdate>2015</risdate><volume>6</volume><issue>10</issue><spage>4130</spage><epage>4143</epage><pages>4130-4143</pages><issn>2156-7085</issn><eissn>2156-7085</eissn><abstract>Current optical coherence tomography (OCT) based micro-angiography is prone to a projection (or tailing) effect due to the high scattering property of blood within overlying patent vessels, creating artifacts that interfere with the interpretation of retinal angiographic results. In this work, the projection effect in OCT micro-angiography is examined and its causality is explained by strong light scattering and photon propagation within blood. A simple practical approach is then introduced to minimize these artifacts presented in the outer retinal avascular space, especially useful for examining clinical cases with choroidal neovascularization (CNV). Demonstrated through in-vivo human posterior eye imaging of healthy and CNV subjects, the proposed method is shown effective to eliminate the projection artifacts in outer retinal space of OCT micro-angiography, resulting in better visualization of the pathological neovascularization when compared with the current common approaches. In addition, it is also shown that the proposed method is applicable to minimize the projection artifacts appearing in deep retinal layers.</abstract><cop>United States</cop><pub>Optical Society of America</pub><pmid>26504660</pmid><doi>10.1364/BOE.6.004130</doi><tpages>14</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2156-7085
ispartof Biomedical optics express, 2015-10, Vol.6 (10), p.4130-4143
issn 2156-7085
2156-7085
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4605069
source PubMed Central; EZB Electronic Journals Library
title Minimizing projection artifacts for accurate presentation of choroidal neovascularization in OCT micro-angiography
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-05T23%3A58%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Minimizing%20projection%20artifacts%20for%20accurate%20presentation%20of%20choroidal%20neovascularization%20in%20OCT%20micro-angiography&rft.jtitle=Biomedical%20optics%20express&rft.au=Zhang,%20Anqi&rft.date=2015-10-01&rft.volume=6&rft.issue=10&rft.spage=4130&rft.epage=4143&rft.pages=4130-4143&rft.issn=2156-7085&rft.eissn=2156-7085&rft_id=info:doi/10.1364/BOE.6.004130&rft_dat=%3Cproquest_pubme%3E1727992315%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c450t-76104ec4cb3e44c6840a8a4da99959f47d4fec48cdaf0ccf34b841b92e0ab8023%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1727992315&rft_id=info:pmid/26504660&rfr_iscdi=true