Effectiveness of thyroid gland shielding in dental CBCT using a paediatric anthropomorphic phantom

The purpose of the study is to evaluate the effectiveness of thyroid shielding in dental CBCT examinations using a paediatric anthropomorphic phantom. An ATOM(®) 706-C anthropomorphic phantom (Computerized Imaging Reference Systems Inc., Norfolk, VA) representing a 10-year-old child was loaded with...

Full description

Saved in:
Bibliographic Details
Published in:Dento-maxillo-facial radiology 2015-03, Vol.44 (3), p.20140285-20140285
Main Authors: Hidalgo, A, Davies, J, Horner, K, Theodorakou, C
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c387t-b23249e13d14c19a30260bcf8695f7cd359217c5872426359340eda49ad128723
cites cdi_FETCH-LOGICAL-c387t-b23249e13d14c19a30260bcf8695f7cd359217c5872426359340eda49ad128723
container_end_page 20140285
container_issue 3
container_start_page 20140285
container_title Dento-maxillo-facial radiology
container_volume 44
creator Hidalgo, A
Davies, J
Horner, K
Theodorakou, C
description The purpose of the study is to evaluate the effectiveness of thyroid shielding in dental CBCT examinations using a paediatric anthropomorphic phantom. An ATOM(®) 706-C anthropomorphic phantom (Computerized Imaging Reference Systems Inc., Norfolk, VA) representing a 10-year-old child was loaded with six thermoluminescent dosemeters positioned at the level of the thyroid gland. Absorbed doses to the thyroid were measured for five commercially available thyroid shields using a large field of view (FOV). A statistically significant thyroid gland dose reduction was found using thyroid shielding for paediatric CBCT examinations for a large FOV. In addition, a statistically significant difference in thyroid gland doses was found depending on the position of the thyroid gland. There was little difference in the effectiveness of thyroid shielding when using a lead vs a lead-equivalent thyroid shield. Similar dose reduction was found using 0.25- and 0.50-mm lead-equivalent thyroid shields. Thyroid shields are to be recommended when undertaking large FOV CBCT examinations on young patients.
doi_str_mv 10.1259/dmfr.20140285
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4614166</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1658419044</sourcerecordid><originalsourceid>FETCH-LOGICAL-c387t-b23249e13d14c19a30260bcf8695f7cd359217c5872426359340eda49ad128723</originalsourceid><addsrcrecordid>eNpVUU1LxDAUDKLo-nH0Kjl6qeblq-1F0MUvELyssLeQTdJtpG1q0hX892bxAz09Zt4wb3iD0CmQC6CivrR9Ey8oAU5oJXbQDHgpC8HpchfNCBWkqBhdHqDDlF4JIZwJuY8OqOAAJZAZWt02jTOTf3eDSwmHBk_tRwze4nWnB4tT611n_bDGfsDWDZPu8PxmvsCbtCU1HrWzXk_RG6yHqY1hDH2IY5vx2GYm9Mdor9Fdciff8wi93N0u5g_F0_P94_z6qTCsKqdiRRnltQNmgRuoNSNUkpVpKlmLpjSWiZpCaURVUk5lRowTZzWvtQWaSXaErr58x82qd9bksFF3aoy-1_FDBe3V_83gW7UO74pL4CBlNjj_NojhbePSpHqfjOvyI1zYJAVSVBxqwnmWFl9SE0NK0TW_Z4CobS9q24v66SXrz_5m-1X_FME-AQ2VioE</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1658419044</pqid></control><display><type>article</type><title>Effectiveness of thyroid gland shielding in dental CBCT using a paediatric anthropomorphic phantom</title><source>Oxford Journals Online</source><creator>Hidalgo, A ; Davies, J ; Horner, K ; Theodorakou, C</creator><creatorcontrib>Hidalgo, A ; Davies, J ; Horner, K ; Theodorakou, C</creatorcontrib><description>The purpose of the study is to evaluate the effectiveness of thyroid shielding in dental CBCT examinations using a paediatric anthropomorphic phantom. An ATOM(®) 706-C anthropomorphic phantom (Computerized Imaging Reference Systems Inc., Norfolk, VA) representing a 10-year-old child was loaded with six thermoluminescent dosemeters positioned at the level of the thyroid gland. Absorbed doses to the thyroid were measured for five commercially available thyroid shields using a large field of view (FOV). A statistically significant thyroid gland dose reduction was found using thyroid shielding for paediatric CBCT examinations for a large FOV. In addition, a statistically significant difference in thyroid gland doses was found depending on the position of the thyroid gland. There was little difference in the effectiveness of thyroid shielding when using a lead vs a lead-equivalent thyroid shield. Similar dose reduction was found using 0.25- and 0.50-mm lead-equivalent thyroid shields. Thyroid shields are to be recommended when undertaking large FOV CBCT examinations on young patients.</description><identifier>ISSN: 0250-832X</identifier><identifier>EISSN: 1476-542X</identifier><identifier>DOI: 10.1259/dmfr.20140285</identifier><identifier>PMID: 25411710</identifier><language>eng</language><publisher>England: The British Institute of Radiology</publisher><subject>Child ; Cone-Beam Computed Tomography ; Dentistry ; Humans ; Phantoms, Imaging ; Radiation Dosage ; Radiation Protection - instrumentation ; Thermoluminescent Dosimetry ; Thyroid Gland - radiation effects</subject><ispartof>Dento-maxillo-facial radiology, 2015-03, Vol.44 (3), p.20140285-20140285</ispartof><rights>2015 The Authors. Published by the British Institute of Radiology 2015 The British Institute of Radiology</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c387t-b23249e13d14c19a30260bcf8695f7cd359217c5872426359340eda49ad128723</citedby><cites>FETCH-LOGICAL-c387t-b23249e13d14c19a30260bcf8695f7cd359217c5872426359340eda49ad128723</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,777,781,882,27906,27907</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/25411710$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hidalgo, A</creatorcontrib><creatorcontrib>Davies, J</creatorcontrib><creatorcontrib>Horner, K</creatorcontrib><creatorcontrib>Theodorakou, C</creatorcontrib><title>Effectiveness of thyroid gland shielding in dental CBCT using a paediatric anthropomorphic phantom</title><title>Dento-maxillo-facial radiology</title><addtitle>Dentomaxillofac Radiol</addtitle><description>The purpose of the study is to evaluate the effectiveness of thyroid shielding in dental CBCT examinations using a paediatric anthropomorphic phantom. An ATOM(®) 706-C anthropomorphic phantom (Computerized Imaging Reference Systems Inc., Norfolk, VA) representing a 10-year-old child was loaded with six thermoluminescent dosemeters positioned at the level of the thyroid gland. Absorbed doses to the thyroid were measured for five commercially available thyroid shields using a large field of view (FOV). A statistically significant thyroid gland dose reduction was found using thyroid shielding for paediatric CBCT examinations for a large FOV. In addition, a statistically significant difference in thyroid gland doses was found depending on the position of the thyroid gland. There was little difference in the effectiveness of thyroid shielding when using a lead vs a lead-equivalent thyroid shield. Similar dose reduction was found using 0.25- and 0.50-mm lead-equivalent thyroid shields. Thyroid shields are to be recommended when undertaking large FOV CBCT examinations on young patients.</description><subject>Child</subject><subject>Cone-Beam Computed Tomography</subject><subject>Dentistry</subject><subject>Humans</subject><subject>Phantoms, Imaging</subject><subject>Radiation Dosage</subject><subject>Radiation Protection - instrumentation</subject><subject>Thermoluminescent Dosimetry</subject><subject>Thyroid Gland - radiation effects</subject><issn>0250-832X</issn><issn>1476-542X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2015</creationdate><recordtype>article</recordtype><recordid>eNpVUU1LxDAUDKLo-nH0Kjl6qeblq-1F0MUvELyssLeQTdJtpG1q0hX892bxAz09Zt4wb3iD0CmQC6CivrR9Ey8oAU5oJXbQDHgpC8HpchfNCBWkqBhdHqDDlF4JIZwJuY8OqOAAJZAZWt02jTOTf3eDSwmHBk_tRwze4nWnB4tT611n_bDGfsDWDZPu8PxmvsCbtCU1HrWzXk_RG6yHqY1hDH2IY5vx2GYm9Mdor9Fdciff8wi93N0u5g_F0_P94_z6qTCsKqdiRRnltQNmgRuoNSNUkpVpKlmLpjSWiZpCaURVUk5lRowTZzWvtQWaSXaErr58x82qd9bksFF3aoy-1_FDBe3V_83gW7UO74pL4CBlNjj_NojhbePSpHqfjOvyI1zYJAVSVBxqwnmWFl9SE0NK0TW_Z4CobS9q24v66SXrz_5m-1X_FME-AQ2VioE</recordid><startdate>20150301</startdate><enddate>20150301</enddate><creator>Hidalgo, A</creator><creator>Davies, J</creator><creator>Horner, K</creator><creator>Theodorakou, C</creator><general>The British Institute of Radiology</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20150301</creationdate><title>Effectiveness of thyroid gland shielding in dental CBCT using a paediatric anthropomorphic phantom</title><author>Hidalgo, A ; Davies, J ; Horner, K ; Theodorakou, C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c387t-b23249e13d14c19a30260bcf8695f7cd359217c5872426359340eda49ad128723</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2015</creationdate><topic>Child</topic><topic>Cone-Beam Computed Tomography</topic><topic>Dentistry</topic><topic>Humans</topic><topic>Phantoms, Imaging</topic><topic>Radiation Dosage</topic><topic>Radiation Protection - instrumentation</topic><topic>Thermoluminescent Dosimetry</topic><topic>Thyroid Gland - radiation effects</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hidalgo, A</creatorcontrib><creatorcontrib>Davies, J</creatorcontrib><creatorcontrib>Horner, K</creatorcontrib><creatorcontrib>Theodorakou, C</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Dento-maxillo-facial radiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hidalgo, A</au><au>Davies, J</au><au>Horner, K</au><au>Theodorakou, C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effectiveness of thyroid gland shielding in dental CBCT using a paediatric anthropomorphic phantom</atitle><jtitle>Dento-maxillo-facial radiology</jtitle><addtitle>Dentomaxillofac Radiol</addtitle><date>2015-03-01</date><risdate>2015</risdate><volume>44</volume><issue>3</issue><spage>20140285</spage><epage>20140285</epage><pages>20140285-20140285</pages><issn>0250-832X</issn><eissn>1476-542X</eissn><abstract>The purpose of the study is to evaluate the effectiveness of thyroid shielding in dental CBCT examinations using a paediatric anthropomorphic phantom. An ATOM(®) 706-C anthropomorphic phantom (Computerized Imaging Reference Systems Inc., Norfolk, VA) representing a 10-year-old child was loaded with six thermoluminescent dosemeters positioned at the level of the thyroid gland. Absorbed doses to the thyroid were measured for five commercially available thyroid shields using a large field of view (FOV). A statistically significant thyroid gland dose reduction was found using thyroid shielding for paediatric CBCT examinations for a large FOV. In addition, a statistically significant difference in thyroid gland doses was found depending on the position of the thyroid gland. There was little difference in the effectiveness of thyroid shielding when using a lead vs a lead-equivalent thyroid shield. Similar dose reduction was found using 0.25- and 0.50-mm lead-equivalent thyroid shields. Thyroid shields are to be recommended when undertaking large FOV CBCT examinations on young patients.</abstract><cop>England</cop><pub>The British Institute of Radiology</pub><pmid>25411710</pmid><doi>10.1259/dmfr.20140285</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0250-832X
ispartof Dento-maxillo-facial radiology, 2015-03, Vol.44 (3), p.20140285-20140285
issn 0250-832X
1476-542X
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_4614166
source Oxford Journals Online
subjects Child
Cone-Beam Computed Tomography
Dentistry
Humans
Phantoms, Imaging
Radiation Dosage
Radiation Protection - instrumentation
Thermoluminescent Dosimetry
Thyroid Gland - radiation effects
title Effectiveness of thyroid gland shielding in dental CBCT using a paediatric anthropomorphic phantom
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-17T08%3A47%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effectiveness%20of%20thyroid%20gland%20shielding%20in%20dental%20CBCT%20using%20a%20paediatric%20anthropomorphic%20phantom&rft.jtitle=Dento-maxillo-facial%20radiology&rft.au=Hidalgo,%20A&rft.date=2015-03-01&rft.volume=44&rft.issue=3&rft.spage=20140285&rft.epage=20140285&rft.pages=20140285-20140285&rft.issn=0250-832X&rft.eissn=1476-542X&rft_id=info:doi/10.1259/dmfr.20140285&rft_dat=%3Cproquest_pubme%3E1658419044%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c387t-b23249e13d14c19a30260bcf8695f7cd359217c5872426359340eda49ad128723%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1658419044&rft_id=info:pmid/25411710&rfr_iscdi=true