Loading…
Radon level in a Nigerian University Campus
Globally, radon is a natural contaminant that affects indoor air quality. Several epidemiological studies have implicated high radon levels in the causality of lung cancer. The study therefore determined the environmental level of radon in selective offices in the Obafemi Awolowo University, Ile-Ife...
Saved in:
Published in: | BMC research notes 2015-11, Vol.8 (675), p.677-677, Article 677 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Globally, radon is a natural contaminant that affects indoor air quality. Several epidemiological studies have implicated high radon levels in the causality of lung cancer. The study therefore determined the environmental level of radon in selective offices in the Obafemi Awolowo University, Ile-Ife. The study employed a descriptive cross-sectional design. A Pro 3-series radon detector was used to determine the radon levels in randomly selected offices. The instrument was set-up in each office and after 48 h, reading was taken and recorded on a proforma data sheet. The structural characteristics of the offices were also assessed by observation.
The result revealed that the radon level obtained in the sampled offices ranged from 0.0 to 5.3 pCi/L (196 Bq/m(3)). The median concentration of radon obtained from sampled offices was 0.9 pCi/L. Almost all (95 %) of the offices had radon levels within the 'permissible' reference level recommended by World Health Organization. Radon levels also showed a statistically significant decline with height of office building with the mean concentration of radon in offices located on the basement, ground floor and first floor being 1.54 ± 1.32, 0.99 ± 0.56, 0.63 ± 0.41 pCi/L respectively, (F statistic 5.8, p < 0.001).
The radon levels obtained in most assessed offices in Obafemi Awolowo University were found to be within the permissible reference levels. Mitigation measures should be put in place in the few offices above permissible levels. |
---|---|
ISSN: | 1756-0500 1756-0500 |
DOI: | 10.1186/s13104-015-1447-7 |