Loading…

An ultrasensitive reverse transcription polymerase chain reaction assay to detect asymptomatic low-density Plasmodium falciparum and Plasmodium vivax infections in small volume blood samples

Highly sensitive, scalable diagnostic methods are needed to guide malaria elimination interventions. While traditional microscopy and rapid diagnostic tests (RDTs) are suitable for the diagnosis of symptomatic malaria infection, more sensitive tests are needed to screen for low-density, asymptomatic...

Full description

Saved in:
Bibliographic Details
Published in:Malaria journal 2015-12, Vol.14 (514), p.520-520, Article 520
Main Authors: Adams, Matthew, Joshi, Sudhaunshu N, Mbambo, Gillian, Mu, Amy Z, Roemmich, Shay M, Shrestha, Biraj, Strauss, Kathy A, Johnson, Nicole Eddington, Oo, Khine Zaw, Hlaing, Tin Maung, Han, Zay Yar, Han, Kay Thwe, Thura, Si, Richards, Adam K, Huang, Fang, Nyunt, Myaing M, Plowe, Christopher V
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Highly sensitive, scalable diagnostic methods are needed to guide malaria elimination interventions. While traditional microscopy and rapid diagnostic tests (RDTs) are suitable for the diagnosis of symptomatic malaria infection, more sensitive tests are needed to screen for low-density, asymptomatic infections that are targeted by interventions aiming to eliminate the entire reservoir of malaria infection in humans. A reverse transcription polymerase chain reaction (RT- PCR) was developed for multiplexed detection of the 18S ribosomal RNA gene and ribosomal RNA of Plasmodium falciparum and Plasmodium vivax. Simulated field samples stored for 14 days with sample preservation buffer were used to assess the analytical sensitivity and specificity. Additionally, 1750 field samples from Southeastern Myanmar were tested both by RDT and ultrasensitive RT-PCR. Limits of detection (LoD) were determined under simulated field conditions. When 0.3 mL blood samples were stored for 14 days at 28 °C and 80% humidity, the LoD was less than 16 parasites/mL for P. falciparum and 19.7 copies/µL for P. vivax (using a plasmid surrogate), about 10,000-fold lower than RDTs. Of the 1739 samples successfully evaluated by both ultrasensitive RT-PCR and RDT, only two were RDT positive while 24 were positive for P. falciparum, 108 were positive for P. vivax, and 127 were positive for either P. vivax and/or P. falciparum using ultrasensitive RT-PCR. This ultrasensitive RT-PCR method is a robust, field-tested screening method that is vastly more sensitive than RDTs. Further optimization may result in a truly scalable tool suitable for widespread surveillance of low-level asymptomatic P. falciparum and P. vivax parasitaemia.
ISSN:1475-2875
1475-2875
DOI:10.1186/s12936-015-1038-z