Development of a low-dose protocol for cone beam CT examinations of the anterior maxilla in children

The aim of this study was to develop a low-dose protocol suitable for cone beam CT (CBCT) examination of an impacted maxillary canine in children by using a combination of dosimetry with subjective and objective image quality assessment. Radiation dose and image quality measurements were made using...

Full description

Saved in:
Bibliographic Details
Published in:British journal of radiology 2015-10, Vol.88 (1054), p.20150559-20150559
Main Authors: Hidalgo Rivas, Jose A, Horner, Keith, Thiruvenkatachari, Badri, Davies, Jonathan, Theodorakou, Chrysoula
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The aim of this study was to develop a low-dose protocol suitable for cone beam CT (CBCT) examination of an impacted maxillary canine in children by using a combination of dosimetry with subjective and objective image quality assessment. Radiation dose and image quality measurements were made using a dental CBCT machine. An image quality phantom was used to investigate the relationship between objective image quality and dose-area product (DAP) for a broad range of exposure settings. Subjective image quality assessment was achieved using a paediatric skull phantom submerged in a water bath for the same range of exposure settings. Eight clinicians assessed each CBCT data set for nine aspects of image quality using a five-point rating scale of agreement. Acceptable image quality, defined using subjective judgements by the clinicians of the skull phantom images, was achievable with DAP values of 127 mGy cm(2) or greater and a polytetrafluoroethylene (PTFE) contrast-to-noise ratio (CNR) of 4.8 or greater. A cautious choice was made to recommend a low-dose protocol of 80 kV and 3 mA for implementation into clinical practice, corresponding to a DAP value of 146 mGy cm(2) and a PTFE CNR of 5.0. A low-dose protocol for this particular CBCT machine was established which represents as much as a 50% reduction compared with manufacturer's recommendations. To the authors' best knowledge, this is the first study that addresses dose optimization in paediatric clinical protocols in dental CBCT. Furthermore, this study explores the relationship between radiation dose, objective and subjective image quality.
ISSN:0007-1285
1748-880X
DOI:10.1259/bjr.20150559