Loading…

Emtricitabine-Triphosphate in Dried Blood Spots as a Marker of Recent Dosing

New objective measures of antiretroviral adherence are needed. We determined if emtricitabine triphosphate (FTC-TP) in dried blood spots (DBS) can be used as a marker of recent dosing with tenofovir disoproxil fumarate-emtricitabine (TDF-FTC). The half-life of FTC-TP was estimated in DBS samples obt...

Full description

Saved in:
Bibliographic Details
Published in:Antimicrobial agents and chemotherapy 2016-11, Vol.60 (11), p.6692-6697
Main Authors: Castillo-Mancilla, Jose, Seifert, Sharon, Campbell, Kayla, Coleman, Stacey, McAllister, Kevin, Zheng, Jia-Hua, Gardner, Edward M, Liu, Albert, Glidden, David V, Grant, Robert, Hosek, Sybil, Wilson, Craig M, Bushman, Lane R, MaWhinney, Samantha, Anderson, Peter L
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:New objective measures of antiretroviral adherence are needed. We determined if emtricitabine triphosphate (FTC-TP) in dried blood spots (DBS) can be used as a marker of recent dosing with tenofovir disoproxil fumarate-emtricitabine (TDF-FTC). The half-life of FTC-TP was estimated in DBS samples obtained from an intensive pharmacokinetic (PK) study of coformulated TDF-FTC in HIV-negative and HIV-infected participants. The concordance of quantifiable FTC-TP in DBS with tenofovir (TFV)/FTC in plasma was evaluated by utilizing paired plasma-DBS samples from participants enrolled in 2 large preexposure prophylaxis (PrEP) open-label trials. The time to FTC-TP nondetectability after TDF-FTC dosing was evaluated utilizing DBS from HIV-negative participants enrolled in a directly observed therapy study of variable adherence to TDF-FTC. The mean (95% confidence interval [CI]) terminal half-life of FTC-TP in the PK study was 35 (23 to 47) h. A total of 143/163 (88%) samples obtained 0 to 48 h post-TDF-FTC dose had quantifiable FTC-TP in DBS, compared with 2/93 (2%) and 0/87 (0%) obtained >48 and >96 h postdose. In 746 paired plasma-DBS samples from 445 participants enrolled in PrEP trials, when both TFV/FTC in plasma were below the limit of quantification, FTC-TP was as well in 98.9% of the samples, and when either TFV or FTC in plasma was quantifiable, FTC-TP was as well in 90.5% of the samples. The half-life of FTC-TP in DBS is short relative to that of TFV-diphosphate (TFV-DP), making it a surrogate for TFV-FTC detection in plasma. FTC-TP can be quantified in DBS simultaneously with TFV-DP, which quantifies cumulative adherence to TDF-FTC. (The clinical trials discussed in this article have been registered at ClinicalTrials.gov under identifiers NCT01040091, NCT02022657, NCT00458393, NCT01772823, and NCT02012621.).
ISSN:0066-4804
1098-6596
DOI:10.1128/AAC.01017-16