Loading…

Characterization of transfer function, resolution and depth of field of a soft X-ray microscope applied to tomography enhancement by Wiener deconvolution

Full field soft X-ray microscopy is becoming a powerful imaging technique to analyze whole cells preserved under cryo conditions. Images obtained in these X-ray microscopes can be combined by tomographic reconstruction to quantitatively estimate the three-dimensional (3D) distribution of absorption...

Full description

Saved in:
Bibliographic Details
Published in:Biomedical optics express 2016-12, Vol.7 (12), p.5092-5103
Main Authors: Otón, Joaquín, Pereiro, Eva, Pérez-Berná, Ana J, Millach, Laia, Sorzano, Carlos Oscar S, Marabini, Roberto, Carazo, José M
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c384t-141235ea04b0c2fa830260ff1cab9fc435dc342f67f537b2db74b0e69bf89dce3
cites cdi_FETCH-LOGICAL-c384t-141235ea04b0c2fa830260ff1cab9fc435dc342f67f537b2db74b0e69bf89dce3
container_end_page 5103
container_issue 12
container_start_page 5092
container_title Biomedical optics express
container_volume 7
creator Otón, Joaquín
Pereiro, Eva
Pérez-Berná, Ana J
Millach, Laia
Sorzano, Carlos Oscar S
Marabini, Roberto
Carazo, José M
description Full field soft X-ray microscopy is becoming a powerful imaging technique to analyze whole cells preserved under cryo conditions. Images obtained in these X-ray microscopes can be combined by tomographic reconstruction to quantitatively estimate the three-dimensional (3D) distribution of absorption coefficients inside the cell. The impulse response of an imaging system is one of the factors that limits the quality of the X-ray microscope reconstructions. The main goal of this work is to experimentally measure the 3D impulse response and to assess the optical resolution and depth of field of the Mistral microscope at ALBA synchrotron (Barcelona, Spain). To this end we measure the microscope apparent transfer function (ATF) and we use it to design a deblurring Wiener filter, obtaining an increase in the image quality when applied to experimental datasets collected at ALBA.
doi_str_mv 10.1364/BOE.7.005092
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5175554</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1853350167</sourcerecordid><originalsourceid>FETCH-LOGICAL-c384t-141235ea04b0c2fa830260ff1cab9fc435dc342f67f537b2db74b0e69bf89dce3</originalsourceid><addsrcrecordid>eNpVkU9rFTEUxYMottTuXEuWLjrP_J3M2wj6aKtQ6MZSdyGTuelEZpIxmSk8v4nf1ozvWWoI5HLz45ybHITeUrKhvBYfPt9ebtSGEEm27AU6ZVTWlSKNfPmsPkHnOf8gZQmhCG9eoxPWENoopk7R711vkrEzJP_LzD4GHB2ekwnZQcJuCXZtXuAEOQ7LX8CEDncwzf2KOg9DtxYG5-hm_L1KZo9Hb1PMNk6AzTQNHjo8x7LH-JDM1O8xhN4ECyOEGbd7fO8hFLsObAyPR5836JUzQ4bz43mG7q4uv-2-VDe31193n24qyxsxV1RQxiUYIlpimTMNJ6wmzlFr2q2zgsvOcsFcrZzkqmVdqwoJ9bZ1zbazwM_Qx4PutLQjlE4ozx_0lPxo0l5H4_X_N8H3-iE-akmVlFIUgfdHgRR_LpBnPfpsYRhMgLhkTRvJuSS0VgW9OKDr9-QE7smGEr0GqkugWulDoAV_93y0J_hffPwPg5-gaQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1853350167</pqid></control><display><type>article</type><title>Characterization of transfer function, resolution and depth of field of a soft X-ray microscope applied to tomography enhancement by Wiener deconvolution</title><source>Open Access: PubMed Central</source><source>EZB Electronic Journals Library</source><creator>Otón, Joaquín ; Pereiro, Eva ; Pérez-Berná, Ana J ; Millach, Laia ; Sorzano, Carlos Oscar S ; Marabini, Roberto ; Carazo, José M</creator><creatorcontrib>Otón, Joaquín ; Pereiro, Eva ; Pérez-Berná, Ana J ; Millach, Laia ; Sorzano, Carlos Oscar S ; Marabini, Roberto ; Carazo, José M</creatorcontrib><description>Full field soft X-ray microscopy is becoming a powerful imaging technique to analyze whole cells preserved under cryo conditions. Images obtained in these X-ray microscopes can be combined by tomographic reconstruction to quantitatively estimate the three-dimensional (3D) distribution of absorption coefficients inside the cell. The impulse response of an imaging system is one of the factors that limits the quality of the X-ray microscope reconstructions. The main goal of this work is to experimentally measure the 3D impulse response and to assess the optical resolution and depth of field of the Mistral microscope at ALBA synchrotron (Barcelona, Spain). To this end we measure the microscope apparent transfer function (ATF) and we use it to design a deblurring Wiener filter, obtaining an increase in the image quality when applied to experimental datasets collected at ALBA.</description><identifier>ISSN: 2156-7085</identifier><identifier>EISSN: 2156-7085</identifier><identifier>DOI: 10.1364/BOE.7.005092</identifier><identifier>PMID: 28018727</identifier><language>eng</language><publisher>United States: Optical Society of America</publisher><ispartof>Biomedical optics express, 2016-12, Vol.7 (12), p.5092-5103</ispartof><rights>2016 Optical Society of America 2016 Optical Society of America</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c384t-141235ea04b0c2fa830260ff1cab9fc435dc342f67f537b2db74b0e69bf89dce3</citedby><cites>FETCH-LOGICAL-c384t-141235ea04b0c2fa830260ff1cab9fc435dc342f67f537b2db74b0e69bf89dce3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5175554/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5175554/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28018727$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Otón, Joaquín</creatorcontrib><creatorcontrib>Pereiro, Eva</creatorcontrib><creatorcontrib>Pérez-Berná, Ana J</creatorcontrib><creatorcontrib>Millach, Laia</creatorcontrib><creatorcontrib>Sorzano, Carlos Oscar S</creatorcontrib><creatorcontrib>Marabini, Roberto</creatorcontrib><creatorcontrib>Carazo, José M</creatorcontrib><title>Characterization of transfer function, resolution and depth of field of a soft X-ray microscope applied to tomography enhancement by Wiener deconvolution</title><title>Biomedical optics express</title><addtitle>Biomed Opt Express</addtitle><description>Full field soft X-ray microscopy is becoming a powerful imaging technique to analyze whole cells preserved under cryo conditions. Images obtained in these X-ray microscopes can be combined by tomographic reconstruction to quantitatively estimate the three-dimensional (3D) distribution of absorption coefficients inside the cell. The impulse response of an imaging system is one of the factors that limits the quality of the X-ray microscope reconstructions. The main goal of this work is to experimentally measure the 3D impulse response and to assess the optical resolution and depth of field of the Mistral microscope at ALBA synchrotron (Barcelona, Spain). To this end we measure the microscope apparent transfer function (ATF) and we use it to design a deblurring Wiener filter, obtaining an increase in the image quality when applied to experimental datasets collected at ALBA.</description><issn>2156-7085</issn><issn>2156-7085</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNpVkU9rFTEUxYMottTuXEuWLjrP_J3M2wj6aKtQ6MZSdyGTuelEZpIxmSk8v4nf1ozvWWoI5HLz45ybHITeUrKhvBYfPt9ebtSGEEm27AU6ZVTWlSKNfPmsPkHnOf8gZQmhCG9eoxPWENoopk7R711vkrEzJP_LzD4GHB2ekwnZQcJuCXZtXuAEOQ7LX8CEDncwzf2KOg9DtxYG5-hm_L1KZo9Hb1PMNk6AzTQNHjo8x7LH-JDM1O8xhN4ECyOEGbd7fO8hFLsObAyPR5836JUzQ4bz43mG7q4uv-2-VDe31193n24qyxsxV1RQxiUYIlpimTMNJ6wmzlFr2q2zgsvOcsFcrZzkqmVdqwoJ9bZ1zbazwM_Qx4PutLQjlE4ozx_0lPxo0l5H4_X_N8H3-iE-akmVlFIUgfdHgRR_LpBnPfpsYRhMgLhkTRvJuSS0VgW9OKDr9-QE7smGEr0GqkugWulDoAV_93y0J_hffPwPg5-gaQ</recordid><startdate>20161201</startdate><enddate>20161201</enddate><creator>Otón, Joaquín</creator><creator>Pereiro, Eva</creator><creator>Pérez-Berná, Ana J</creator><creator>Millach, Laia</creator><creator>Sorzano, Carlos Oscar S</creator><creator>Marabini, Roberto</creator><creator>Carazo, José M</creator><general>Optical Society of America</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20161201</creationdate><title>Characterization of transfer function, resolution and depth of field of a soft X-ray microscope applied to tomography enhancement by Wiener deconvolution</title><author>Otón, Joaquín ; Pereiro, Eva ; Pérez-Berná, Ana J ; Millach, Laia ; Sorzano, Carlos Oscar S ; Marabini, Roberto ; Carazo, José M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c384t-141235ea04b0c2fa830260ff1cab9fc435dc342f67f537b2db74b0e69bf89dce3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Otón, Joaquín</creatorcontrib><creatorcontrib>Pereiro, Eva</creatorcontrib><creatorcontrib>Pérez-Berná, Ana J</creatorcontrib><creatorcontrib>Millach, Laia</creatorcontrib><creatorcontrib>Sorzano, Carlos Oscar S</creatorcontrib><creatorcontrib>Marabini, Roberto</creatorcontrib><creatorcontrib>Carazo, José M</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Biomedical optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Otón, Joaquín</au><au>Pereiro, Eva</au><au>Pérez-Berná, Ana J</au><au>Millach, Laia</au><au>Sorzano, Carlos Oscar S</au><au>Marabini, Roberto</au><au>Carazo, José M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Characterization of transfer function, resolution and depth of field of a soft X-ray microscope applied to tomography enhancement by Wiener deconvolution</atitle><jtitle>Biomedical optics express</jtitle><addtitle>Biomed Opt Express</addtitle><date>2016-12-01</date><risdate>2016</risdate><volume>7</volume><issue>12</issue><spage>5092</spage><epage>5103</epage><pages>5092-5103</pages><issn>2156-7085</issn><eissn>2156-7085</eissn><abstract>Full field soft X-ray microscopy is becoming a powerful imaging technique to analyze whole cells preserved under cryo conditions. Images obtained in these X-ray microscopes can be combined by tomographic reconstruction to quantitatively estimate the three-dimensional (3D) distribution of absorption coefficients inside the cell. The impulse response of an imaging system is one of the factors that limits the quality of the X-ray microscope reconstructions. The main goal of this work is to experimentally measure the 3D impulse response and to assess the optical resolution and depth of field of the Mistral microscope at ALBA synchrotron (Barcelona, Spain). To this end we measure the microscope apparent transfer function (ATF) and we use it to design a deblurring Wiener filter, obtaining an increase in the image quality when applied to experimental datasets collected at ALBA.</abstract><cop>United States</cop><pub>Optical Society of America</pub><pmid>28018727</pmid><doi>10.1364/BOE.7.005092</doi><tpages>12</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2156-7085
ispartof Biomedical optics express, 2016-12, Vol.7 (12), p.5092-5103
issn 2156-7085
2156-7085
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5175554
source Open Access: PubMed Central; EZB Electronic Journals Library
title Characterization of transfer function, resolution and depth of field of a soft X-ray microscope applied to tomography enhancement by Wiener deconvolution
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T12%3A25%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Characterization%20of%20transfer%20function,%20resolution%20and%20depth%20of%20field%20of%20a%20soft%20X-ray%20microscope%20applied%20to%20tomography%20enhancement%20by%20Wiener%20deconvolution&rft.jtitle=Biomedical%20optics%20express&rft.au=Ot%C3%B3n,%20Joaqu%C3%ADn&rft.date=2016-12-01&rft.volume=7&rft.issue=12&rft.spage=5092&rft.epage=5103&rft.pages=5092-5103&rft.issn=2156-7085&rft.eissn=2156-7085&rft_id=info:doi/10.1364/BOE.7.005092&rft_dat=%3Cproquest_pubme%3E1853350167%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c384t-141235ea04b0c2fa830260ff1cab9fc435dc342f67f537b2db74b0e69bf89dce3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1853350167&rft_id=info:pmid/28018727&rfr_iscdi=true