Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography
The aim of this study was to evaluate, using cone-beam computed tomography (CBCT), transportation and centralization of different nickel-titanium (NiTi) rotary instruments. One hundred and twenty eight mandibular premolars were selected and instrumented using the following brands of NiTi files: Wave...
Saved in:
Published in: | The open dentistry journal 2017-01, Vol.11 (1), p.71-78 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c405t-d08406e86a79730e9fd663f2bf739ba978893ee3d7a481e56f133ceddf5e1e4f3 |
---|---|
cites | cdi_FETCH-LOGICAL-c405t-d08406e86a79730e9fd663f2bf739ba978893ee3d7a481e56f133ceddf5e1e4f3 |
container_end_page | 78 |
container_issue | 1 |
container_start_page | 71 |
container_title | The open dentistry journal |
container_volume | 11 |
creator | Mamede-Neto, Iussif Borges, Alvaro Henrique Guedes, Orlando Aguirre de Oliveira, Durvalino Pedro, Fábio Luis Miranda Estrela, Carlos |
description | The aim of this study was to evaluate, using cone-beam computed tomography (CBCT), transportation and centralization of different nickel-titanium (NiTi) rotary instruments.
One hundred and twenty eight mandibular premolars were selected and instrumented using the following brands of NiTi files: WaveOne, WaveOne Gold, Reciproc, ProTaper Next, ProTaper Gold, Mtwo, BioRaCe and RaCe. CBCT imaging was performed before and after root canal preparation to obtain measurements of mesial and distal dentin walls and calculations of root canal transportation and centralization. A normal distribution of data was confirmed by the Kolmogorov-Smirnov and Levene tests, and results were assessed using the Kruskal-Wallis test. Statistical significance was set at 5%.
ProTaper Gold produced the lowest canal transportation values, and RaCe, the highest. ProTaper Gold files also showed the highest values for centering ability, whereas BioRaCe showed the lowest. No significant differences were found across the different instruments in terms of canal transportation and centering ability (P > 0.05).
Based on the methodology employed, all instruments used for root canal preparation of mandibular premolars performed similarly with regard to canal transportation and centering ability. |
doi_str_mv | 10.2174/1874210601711010071 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5345325</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1882497606</sourcerecordid><originalsourceid>FETCH-LOGICAL-c405t-d08406e86a79730e9fd663f2bf739ba978893ee3d7a481e56f133ceddf5e1e4f3</originalsourceid><addsrcrecordid>eNptUV2L1DAUDaK46-gvECSPvtRNmjZJX4SxrLqwfrDMPoe0vZmNNklNUmH-ir_WDPvBCsKFHM695yQ3B6HXlLyrqWjOqBRNTQknVFBKKCGCPkGnR7Y60k8f4RP0IqUfhHBGJH-OTmrJWkEIOUV_rkLIuNdez3gXtU9LiFlnGzzWfsI9-AzR-j3eDna2-YCDwV_t-BPmamez9nZ1-CpkHQ_4wqccV1cUCVuPvxS9HdZZR_w9ggsFJLxNCUpN-DodTfvgofoA2hXkljWXxi64sI96uTm8RM-MnhO8ujs36Prj-a7_XF1--3TRby-rsSFtriYiG8JBci06wQh0ZuKcmXowgnWD7oSUHQNgk9CNpNByQxkbYZpMCxQawzbo_a3vsg4OprEsEPWslmhdWUsFbdW_HW9v1D78Vi1rWla3xeDtnUEMv1ZIWTmbRphn7SGsSVEp66YTvHz_BrHb0TGGlCKYh2soUcdU1X9SLao3j1_4oLmPkf0Fd1WhQw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1882497606</pqid></control><display><type>article</type><title>Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography</title><source>PubMed (Medline)</source><source>Bentham Science Publishers OA</source><creator>Mamede-Neto, Iussif ; Borges, Alvaro Henrique ; Guedes, Orlando Aguirre ; de Oliveira, Durvalino ; Pedro, Fábio Luis Miranda ; Estrela, Carlos</creator><creatorcontrib>Mamede-Neto, Iussif ; Borges, Alvaro Henrique ; Guedes, Orlando Aguirre ; de Oliveira, Durvalino ; Pedro, Fábio Luis Miranda ; Estrela, Carlos</creatorcontrib><description>The aim of this study was to evaluate, using cone-beam computed tomography (CBCT), transportation and centralization of different nickel-titanium (NiTi) rotary instruments.
One hundred and twenty eight mandibular premolars were selected and instrumented using the following brands of NiTi files: WaveOne, WaveOne Gold, Reciproc, ProTaper Next, ProTaper Gold, Mtwo, BioRaCe and RaCe. CBCT imaging was performed before and after root canal preparation to obtain measurements of mesial and distal dentin walls and calculations of root canal transportation and centralization. A normal distribution of data was confirmed by the Kolmogorov-Smirnov and Levene tests, and results were assessed using the Kruskal-Wallis test. Statistical significance was set at 5%.
ProTaper Gold produced the lowest canal transportation values, and RaCe, the highest. ProTaper Gold files also showed the highest values for centering ability, whereas BioRaCe showed the lowest. No significant differences were found across the different instruments in terms of canal transportation and centering ability (P > 0.05).
Based on the methodology employed, all instruments used for root canal preparation of mandibular premolars performed similarly with regard to canal transportation and centering ability.</description><identifier>ISSN: 1874-2106</identifier><identifier>EISSN: 1874-2106</identifier><identifier>DOI: 10.2174/1874210601711010071</identifier><identifier>PMID: 28357000</identifier><language>eng</language><publisher>United Arab Emirates: Bentham Open</publisher><ispartof>The open dentistry journal, 2017-01, Vol.11 (1), p.71-78</ispartof><rights>2017 Mamede-Neto 2017 Bentham Open</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c405t-d08406e86a79730e9fd663f2bf739ba978893ee3d7a481e56f133ceddf5e1e4f3</citedby><cites>FETCH-LOGICAL-c405t-d08406e86a79730e9fd663f2bf739ba978893ee3d7a481e56f133ceddf5e1e4f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5345325/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5345325/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,3727,27900,27901,53765,53767</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28357000$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mamede-Neto, Iussif</creatorcontrib><creatorcontrib>Borges, Alvaro Henrique</creatorcontrib><creatorcontrib>Guedes, Orlando Aguirre</creatorcontrib><creatorcontrib>de Oliveira, Durvalino</creatorcontrib><creatorcontrib>Pedro, Fábio Luis Miranda</creatorcontrib><creatorcontrib>Estrela, Carlos</creatorcontrib><title>Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography</title><title>The open dentistry journal</title><addtitle>Open Dent J</addtitle><description>The aim of this study was to evaluate, using cone-beam computed tomography (CBCT), transportation and centralization of different nickel-titanium (NiTi) rotary instruments.
One hundred and twenty eight mandibular premolars were selected and instrumented using the following brands of NiTi files: WaveOne, WaveOne Gold, Reciproc, ProTaper Next, ProTaper Gold, Mtwo, BioRaCe and RaCe. CBCT imaging was performed before and after root canal preparation to obtain measurements of mesial and distal dentin walls and calculations of root canal transportation and centralization. A normal distribution of data was confirmed by the Kolmogorov-Smirnov and Levene tests, and results were assessed using the Kruskal-Wallis test. Statistical significance was set at 5%.
ProTaper Gold produced the lowest canal transportation values, and RaCe, the highest. ProTaper Gold files also showed the highest values for centering ability, whereas BioRaCe showed the lowest. No significant differences were found across the different instruments in terms of canal transportation and centering ability (P > 0.05).
Based on the methodology employed, all instruments used for root canal preparation of mandibular premolars performed similarly with regard to canal transportation and centering ability.</description><issn>1874-2106</issn><issn>1874-2106</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNptUV2L1DAUDaK46-gvECSPvtRNmjZJX4SxrLqwfrDMPoe0vZmNNklNUmH-ir_WDPvBCsKFHM695yQ3B6HXlLyrqWjOqBRNTQknVFBKKCGCPkGnR7Y60k8f4RP0IqUfhHBGJH-OTmrJWkEIOUV_rkLIuNdez3gXtU9LiFlnGzzWfsI9-AzR-j3eDna2-YCDwV_t-BPmamez9nZ1-CpkHQ_4wqccV1cUCVuPvxS9HdZZR_w9ggsFJLxNCUpN-DodTfvgofoA2hXkljWXxi64sI96uTm8RM-MnhO8ujs36Prj-a7_XF1--3TRby-rsSFtriYiG8JBci06wQh0ZuKcmXowgnWD7oSUHQNgk9CNpNByQxkbYZpMCxQawzbo_a3vsg4OprEsEPWslmhdWUsFbdW_HW9v1D78Vi1rWla3xeDtnUEMv1ZIWTmbRphn7SGsSVEp66YTvHz_BrHb0TGGlCKYh2soUcdU1X9SLao3j1_4oLmPkf0Fd1WhQw</recordid><startdate>20170101</startdate><enddate>20170101</enddate><creator>Mamede-Neto, Iussif</creator><creator>Borges, Alvaro Henrique</creator><creator>Guedes, Orlando Aguirre</creator><creator>de Oliveira, Durvalino</creator><creator>Pedro, Fábio Luis Miranda</creator><creator>Estrela, Carlos</creator><general>Bentham Open</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20170101</creationdate><title>Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography</title><author>Mamede-Neto, Iussif ; Borges, Alvaro Henrique ; Guedes, Orlando Aguirre ; de Oliveira, Durvalino ; Pedro, Fábio Luis Miranda ; Estrela, Carlos</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c405t-d08406e86a79730e9fd663f2bf739ba978893ee3d7a481e56f133ceddf5e1e4f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mamede-Neto, Iussif</creatorcontrib><creatorcontrib>Borges, Alvaro Henrique</creatorcontrib><creatorcontrib>Guedes, Orlando Aguirre</creatorcontrib><creatorcontrib>de Oliveira, Durvalino</creatorcontrib><creatorcontrib>Pedro, Fábio Luis Miranda</creatorcontrib><creatorcontrib>Estrela, Carlos</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>The open dentistry journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mamede-Neto, Iussif</au><au>Borges, Alvaro Henrique</au><au>Guedes, Orlando Aguirre</au><au>de Oliveira, Durvalino</au><au>Pedro, Fábio Luis Miranda</au><au>Estrela, Carlos</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography</atitle><jtitle>The open dentistry journal</jtitle><addtitle>Open Dent J</addtitle><date>2017-01-01</date><risdate>2017</risdate><volume>11</volume><issue>1</issue><spage>71</spage><epage>78</epage><pages>71-78</pages><issn>1874-2106</issn><eissn>1874-2106</eissn><abstract>The aim of this study was to evaluate, using cone-beam computed tomography (CBCT), transportation and centralization of different nickel-titanium (NiTi) rotary instruments.
One hundred and twenty eight mandibular premolars were selected and instrumented using the following brands of NiTi files: WaveOne, WaveOne Gold, Reciproc, ProTaper Next, ProTaper Gold, Mtwo, BioRaCe and RaCe. CBCT imaging was performed before and after root canal preparation to obtain measurements of mesial and distal dentin walls and calculations of root canal transportation and centralization. A normal distribution of data was confirmed by the Kolmogorov-Smirnov and Levene tests, and results were assessed using the Kruskal-Wallis test. Statistical significance was set at 5%.
ProTaper Gold produced the lowest canal transportation values, and RaCe, the highest. ProTaper Gold files also showed the highest values for centering ability, whereas BioRaCe showed the lowest. No significant differences were found across the different instruments in terms of canal transportation and centering ability (P > 0.05).
Based on the methodology employed, all instruments used for root canal preparation of mandibular premolars performed similarly with regard to canal transportation and centering ability.</abstract><cop>United Arab Emirates</cop><pub>Bentham Open</pub><pmid>28357000</pmid><doi>10.2174/1874210601711010071</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1874-2106 |
ispartof | The open dentistry journal, 2017-01, Vol.11 (1), p.71-78 |
issn | 1874-2106 1874-2106 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5345325 |
source | PubMed (Medline); Bentham Science Publishers OA |
title | Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-24T17%3A25%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Root%20Canal%20Transportation%20and%20Centering%20Ability%20of%20Nickel-Titanium%20Rotary%20Instruments%20in%20Mandibular%20Premolars%20Assessed%20Using%20Cone-Beam%20Computed%20Tomography&rft.jtitle=The%20open%20dentistry%20journal&rft.au=Mamede-Neto,%20Iussif&rft.date=2017-01-01&rft.volume=11&rft.issue=1&rft.spage=71&rft.epage=78&rft.pages=71-78&rft.issn=1874-2106&rft.eissn=1874-2106&rft_id=info:doi/10.2174/1874210601711010071&rft_dat=%3Cproquest_pubme%3E1882497606%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c405t-d08406e86a79730e9fd663f2bf739ba978893ee3d7a481e56f133ceddf5e1e4f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1882497606&rft_id=info:pmid/28357000&rfr_iscdi=true |