Loading…

Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography

The aim of this study was to evaluate, using cone-beam computed tomography (CBCT), transportation and centralization of different nickel-titanium (NiTi) rotary instruments. One hundred and twenty eight mandibular premolars were selected and instrumented using the following brands of NiTi files: Wave...

Full description

Saved in:
Bibliographic Details
Published in:The open dentistry journal 2017-01, Vol.11 (1), p.71-78
Main Authors: Mamede-Neto, Iussif, Borges, Alvaro Henrique, Guedes, Orlando Aguirre, de Oliveira, Durvalino, Pedro, Fábio Luis Miranda, Estrela, Carlos
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c405t-d08406e86a79730e9fd663f2bf739ba978893ee3d7a481e56f133ceddf5e1e4f3
cites cdi_FETCH-LOGICAL-c405t-d08406e86a79730e9fd663f2bf739ba978893ee3d7a481e56f133ceddf5e1e4f3
container_end_page 78
container_issue 1
container_start_page 71
container_title The open dentistry journal
container_volume 11
creator Mamede-Neto, Iussif
Borges, Alvaro Henrique
Guedes, Orlando Aguirre
de Oliveira, Durvalino
Pedro, Fábio Luis Miranda
Estrela, Carlos
description The aim of this study was to evaluate, using cone-beam computed tomography (CBCT), transportation and centralization of different nickel-titanium (NiTi) rotary instruments. One hundred and twenty eight mandibular premolars were selected and instrumented using the following brands of NiTi files: WaveOne, WaveOne Gold, Reciproc, ProTaper Next, ProTaper Gold, Mtwo, BioRaCe and RaCe. CBCT imaging was performed before and after root canal preparation to obtain measurements of mesial and distal dentin walls and calculations of root canal transportation and centralization. A normal distribution of data was confirmed by the Kolmogorov-Smirnov and Levene tests, and results were assessed using the Kruskal-Wallis test. Statistical significance was set at 5%. ProTaper Gold produced the lowest canal transportation values, and RaCe, the highest. ProTaper Gold files also showed the highest values for centering ability, whereas BioRaCe showed the lowest. No significant differences were found across the different instruments in terms of canal transportation and centering ability (P > 0.05). Based on the methodology employed, all instruments used for root canal preparation of mandibular premolars performed similarly with regard to canal transportation and centering ability.
doi_str_mv 10.2174/1874210601711010071
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5345325</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1882497606</sourcerecordid><originalsourceid>FETCH-LOGICAL-c405t-d08406e86a79730e9fd663f2bf739ba978893ee3d7a481e56f133ceddf5e1e4f3</originalsourceid><addsrcrecordid>eNptUV2L1DAUDaK46-gvECSPvtRNmjZJX4SxrLqwfrDMPoe0vZmNNklNUmH-ir_WDPvBCsKFHM695yQ3B6HXlLyrqWjOqBRNTQknVFBKKCGCPkGnR7Y60k8f4RP0IqUfhHBGJH-OTmrJWkEIOUV_rkLIuNdez3gXtU9LiFlnGzzWfsI9-AzR-j3eDna2-YCDwV_t-BPmamez9nZ1-CpkHQ_4wqccV1cUCVuPvxS9HdZZR_w9ggsFJLxNCUpN-DodTfvgofoA2hXkljWXxi64sI96uTm8RM-MnhO8ujs36Prj-a7_XF1--3TRby-rsSFtriYiG8JBci06wQh0ZuKcmXowgnWD7oSUHQNgk9CNpNByQxkbYZpMCxQawzbo_a3vsg4OprEsEPWslmhdWUsFbdW_HW9v1D78Vi1rWla3xeDtnUEMv1ZIWTmbRphn7SGsSVEp66YTvHz_BrHb0TGGlCKYh2soUcdU1X9SLao3j1_4oLmPkf0Fd1WhQw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1882497606</pqid></control><display><type>article</type><title>Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography</title><source>PubMed (Medline)</source><source>Bentham Science Publishers OA</source><creator>Mamede-Neto, Iussif ; Borges, Alvaro Henrique ; Guedes, Orlando Aguirre ; de Oliveira, Durvalino ; Pedro, Fábio Luis Miranda ; Estrela, Carlos</creator><creatorcontrib>Mamede-Neto, Iussif ; Borges, Alvaro Henrique ; Guedes, Orlando Aguirre ; de Oliveira, Durvalino ; Pedro, Fábio Luis Miranda ; Estrela, Carlos</creatorcontrib><description>The aim of this study was to evaluate, using cone-beam computed tomography (CBCT), transportation and centralization of different nickel-titanium (NiTi) rotary instruments. One hundred and twenty eight mandibular premolars were selected and instrumented using the following brands of NiTi files: WaveOne, WaveOne Gold, Reciproc, ProTaper Next, ProTaper Gold, Mtwo, BioRaCe and RaCe. CBCT imaging was performed before and after root canal preparation to obtain measurements of mesial and distal dentin walls and calculations of root canal transportation and centralization. A normal distribution of data was confirmed by the Kolmogorov-Smirnov and Levene tests, and results were assessed using the Kruskal-Wallis test. Statistical significance was set at 5%. ProTaper Gold produced the lowest canal transportation values, and RaCe, the highest. ProTaper Gold files also showed the highest values for centering ability, whereas BioRaCe showed the lowest. No significant differences were found across the different instruments in terms of canal transportation and centering ability (P &gt; 0.05). Based on the methodology employed, all instruments used for root canal preparation of mandibular premolars performed similarly with regard to canal transportation and centering ability.</description><identifier>ISSN: 1874-2106</identifier><identifier>EISSN: 1874-2106</identifier><identifier>DOI: 10.2174/1874210601711010071</identifier><identifier>PMID: 28357000</identifier><language>eng</language><publisher>United Arab Emirates: Bentham Open</publisher><ispartof>The open dentistry journal, 2017-01, Vol.11 (1), p.71-78</ispartof><rights>2017 Mamede-Neto 2017 Bentham Open</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c405t-d08406e86a79730e9fd663f2bf739ba978893ee3d7a481e56f133ceddf5e1e4f3</citedby><cites>FETCH-LOGICAL-c405t-d08406e86a79730e9fd663f2bf739ba978893ee3d7a481e56f133ceddf5e1e4f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5345325/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5345325/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,3727,27900,27901,53765,53767</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/28357000$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Mamede-Neto, Iussif</creatorcontrib><creatorcontrib>Borges, Alvaro Henrique</creatorcontrib><creatorcontrib>Guedes, Orlando Aguirre</creatorcontrib><creatorcontrib>de Oliveira, Durvalino</creatorcontrib><creatorcontrib>Pedro, Fábio Luis Miranda</creatorcontrib><creatorcontrib>Estrela, Carlos</creatorcontrib><title>Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography</title><title>The open dentistry journal</title><addtitle>Open Dent J</addtitle><description>The aim of this study was to evaluate, using cone-beam computed tomography (CBCT), transportation and centralization of different nickel-titanium (NiTi) rotary instruments. One hundred and twenty eight mandibular premolars were selected and instrumented using the following brands of NiTi files: WaveOne, WaveOne Gold, Reciproc, ProTaper Next, ProTaper Gold, Mtwo, BioRaCe and RaCe. CBCT imaging was performed before and after root canal preparation to obtain measurements of mesial and distal dentin walls and calculations of root canal transportation and centralization. A normal distribution of data was confirmed by the Kolmogorov-Smirnov and Levene tests, and results were assessed using the Kruskal-Wallis test. Statistical significance was set at 5%. ProTaper Gold produced the lowest canal transportation values, and RaCe, the highest. ProTaper Gold files also showed the highest values for centering ability, whereas BioRaCe showed the lowest. No significant differences were found across the different instruments in terms of canal transportation and centering ability (P &gt; 0.05). Based on the methodology employed, all instruments used for root canal preparation of mandibular premolars performed similarly with regard to canal transportation and centering ability.</description><issn>1874-2106</issn><issn>1874-2106</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNptUV2L1DAUDaK46-gvECSPvtRNmjZJX4SxrLqwfrDMPoe0vZmNNklNUmH-ir_WDPvBCsKFHM695yQ3B6HXlLyrqWjOqBRNTQknVFBKKCGCPkGnR7Y60k8f4RP0IqUfhHBGJH-OTmrJWkEIOUV_rkLIuNdez3gXtU9LiFlnGzzWfsI9-AzR-j3eDna2-YCDwV_t-BPmamez9nZ1-CpkHQ_4wqccV1cUCVuPvxS9HdZZR_w9ggsFJLxNCUpN-DodTfvgofoA2hXkljWXxi64sI96uTm8RM-MnhO8ujs36Prj-a7_XF1--3TRby-rsSFtriYiG8JBci06wQh0ZuKcmXowgnWD7oSUHQNgk9CNpNByQxkbYZpMCxQawzbo_a3vsg4OprEsEPWslmhdWUsFbdW_HW9v1D78Vi1rWla3xeDtnUEMv1ZIWTmbRphn7SGsSVEp66YTvHz_BrHb0TGGlCKYh2soUcdU1X9SLao3j1_4oLmPkf0Fd1WhQw</recordid><startdate>20170101</startdate><enddate>20170101</enddate><creator>Mamede-Neto, Iussif</creator><creator>Borges, Alvaro Henrique</creator><creator>Guedes, Orlando Aguirre</creator><creator>de Oliveira, Durvalino</creator><creator>Pedro, Fábio Luis Miranda</creator><creator>Estrela, Carlos</creator><general>Bentham Open</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20170101</creationdate><title>Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography</title><author>Mamede-Neto, Iussif ; Borges, Alvaro Henrique ; Guedes, Orlando Aguirre ; de Oliveira, Durvalino ; Pedro, Fábio Luis Miranda ; Estrela, Carlos</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c405t-d08406e86a79730e9fd663f2bf739ba978893ee3d7a481e56f133ceddf5e1e4f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mamede-Neto, Iussif</creatorcontrib><creatorcontrib>Borges, Alvaro Henrique</creatorcontrib><creatorcontrib>Guedes, Orlando Aguirre</creatorcontrib><creatorcontrib>de Oliveira, Durvalino</creatorcontrib><creatorcontrib>Pedro, Fábio Luis Miranda</creatorcontrib><creatorcontrib>Estrela, Carlos</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>The open dentistry journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mamede-Neto, Iussif</au><au>Borges, Alvaro Henrique</au><au>Guedes, Orlando Aguirre</au><au>de Oliveira, Durvalino</au><au>Pedro, Fábio Luis Miranda</au><au>Estrela, Carlos</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography</atitle><jtitle>The open dentistry journal</jtitle><addtitle>Open Dent J</addtitle><date>2017-01-01</date><risdate>2017</risdate><volume>11</volume><issue>1</issue><spage>71</spage><epage>78</epage><pages>71-78</pages><issn>1874-2106</issn><eissn>1874-2106</eissn><abstract>The aim of this study was to evaluate, using cone-beam computed tomography (CBCT), transportation and centralization of different nickel-titanium (NiTi) rotary instruments. One hundred and twenty eight mandibular premolars were selected and instrumented using the following brands of NiTi files: WaveOne, WaveOne Gold, Reciproc, ProTaper Next, ProTaper Gold, Mtwo, BioRaCe and RaCe. CBCT imaging was performed before and after root canal preparation to obtain measurements of mesial and distal dentin walls and calculations of root canal transportation and centralization. A normal distribution of data was confirmed by the Kolmogorov-Smirnov and Levene tests, and results were assessed using the Kruskal-Wallis test. Statistical significance was set at 5%. ProTaper Gold produced the lowest canal transportation values, and RaCe, the highest. ProTaper Gold files also showed the highest values for centering ability, whereas BioRaCe showed the lowest. No significant differences were found across the different instruments in terms of canal transportation and centering ability (P &gt; 0.05). Based on the methodology employed, all instruments used for root canal preparation of mandibular premolars performed similarly with regard to canal transportation and centering ability.</abstract><cop>United Arab Emirates</cop><pub>Bentham Open</pub><pmid>28357000</pmid><doi>10.2174/1874210601711010071</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1874-2106
ispartof The open dentistry journal, 2017-01, Vol.11 (1), p.71-78
issn 1874-2106
1874-2106
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5345325
source PubMed (Medline); Bentham Science Publishers OA
title Root Canal Transportation and Centering Ability of Nickel-Titanium Rotary Instruments in Mandibular Premolars Assessed Using Cone-Beam Computed Tomography
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-24T17%3A25%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Root%20Canal%20Transportation%20and%20Centering%20Ability%20of%20Nickel-Titanium%20Rotary%20Instruments%20in%20Mandibular%20Premolars%20Assessed%20Using%20Cone-Beam%20Computed%20Tomography&rft.jtitle=The%20open%20dentistry%20journal&rft.au=Mamede-Neto,%20Iussif&rft.date=2017-01-01&rft.volume=11&rft.issue=1&rft.spage=71&rft.epage=78&rft.pages=71-78&rft.issn=1874-2106&rft.eissn=1874-2106&rft_id=info:doi/10.2174/1874210601711010071&rft_dat=%3Cproquest_pubme%3E1882497606%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c405t-d08406e86a79730e9fd663f2bf739ba978893ee3d7a481e56f133ceddf5e1e4f3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1882497606&rft_id=info:pmid/28357000&rfr_iscdi=true