Behavior of steel-sheathed shear walls subjected to seismic and fire loads

A series of tests was conducted on six 2.7m×3.7m shear wall specimens consisting of cold-formed steel framing sheathed on one side with sheet steel adhered to gypsum board and on the opposite side with plain gypsum board. The specimens were subjected to various sequences of simulated seismic shear d...

Full description

Saved in:
Bibliographic Details
Published in:Fire safety journal 2017-07, Vol.91, p.524-531
Main Authors: Hoehler, Matthew S., Smith, Christopher M., Hutchinson, Tara C., Wang, Xiang, Meacham, Brian J., Kamath, Praveen
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A series of tests was conducted on six 2.7m×3.7m shear wall specimens consisting of cold-formed steel framing sheathed on one side with sheet steel adhered to gypsum board and on the opposite side with plain gypsum board. The specimens were subjected to various sequences of simulated seismic shear deformation and fire exposure to study the influence of multi-hazard interactions on the lateral load resistance of the walls. The test program was designed to complement a parallel effort at the University of California, San Diego to investigate a six-story building subjected to earthquakes and fires. The test results reported here indicate that the fire exposure caused a shift in the failure mode of the walls from local buckling of the sheet steel in cases without fire exposure, to global buckling of the sheet steel with an accompanying 35% reduction in lateral load capacity after the wall had been exposed to fire. This behavior appears to be predictable, which is encouraging from the standpoint of residual lateral load capacity under these severe multi-hazard actions.
ISSN:0379-7112
1873-7226
DOI:10.1016/j.firesaf.2017.03.021