Loading…

A Feasibility Study on Ribs as Anatomical Landmarks for Motion Tracking of Lung and Liver Tumors at External Beam Radiotherapy

At external beam radiotherapy for some tumors located at thorax region due to lack of information in gray scale fluoroscopic images tumor position determination is problematic. One of the clinical strategies is to implant clip as internal fiducial marker inside or near tumor to represent tumor posit...

Full description

Saved in:
Bibliographic Details
Published in:Technology in cancer research & treatment 2017-02, Vol.16 (1), p.99-111
Main Authors: Nankali, Saber, Torshabi, Ahmad Esmaili, Miandoab, Payam Samadi
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Request full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c462t-e65630a7d4063ab9280bebee7a94637ef11ba2b4f7074ce6b5bc1004789569883
cites cdi_FETCH-LOGICAL-c462t-e65630a7d4063ab9280bebee7a94637ef11ba2b4f7074ce6b5bc1004789569883
container_end_page 111
container_issue 1
container_start_page 99
container_title Technology in cancer research & treatment
container_volume 16
creator Nankali, Saber
Torshabi, Ahmad Esmaili
Miandoab, Payam Samadi
description At external beam radiotherapy for some tumors located at thorax region due to lack of information in gray scale fluoroscopic images tumor position determination is problematic. One of the clinical strategies is to implant clip as internal fiducial marker inside or near tumor to represent tumor position while the contrast of implanted clip is highly observable rather than tumor. As alternative, using natural anatomical landmarks located at thorax region of patient body is proposed to extract tumor position information without implanting clips that is invasive method with possible side effect. Among natural landmarks, ribs of rib-cage structure that result proper visualization at X-ray images may be optimal as representative for tumor motion. In this study, we investigated the existence of possible correlation between ribs as natural anatomical landmarks and various lung and liver tumors located at different sites as challenging issue. A simulation study was performed using data extracted from 4-dimensional extended cardiac-torso anthropomorphic phantom that is able to simulate motion effect of dynamic organs, as well. Several tumor sites with predefined distances originated from chosen ribs at anterior–posterior direction were simulated at 3 upper, middle, and lower parts of chest. Correlation coefficient between ribs and tumors was calculated to investigate the robustness of ribs as anatomical landmarks for tumor motion tracking. Moreover, a consistent correlation model was taken into account to track tumor motion with a rib as best candidate among selected ribs. Final results represent availability of using rib cage as anatomical landmark to track lung and liver tumors in a noninvasive way. Observations of our calculations showed a proper correlation between tumors and ribs while the degree of this correlation is changing depends on tumor site while lung tumors are more varied and complex with less correlation with ribs motion against liver tumors.
doi_str_mv 10.1177/1533034615595737
format article
fullrecord <record><control><sourceid>proquest_AFRWT</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5616108</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1533034615595737</sage_id><sourcerecordid>1826629401</sourcerecordid><originalsourceid>FETCH-LOGICAL-c462t-e65630a7d4063ab9280bebee7a94637ef11ba2b4f7074ce6b5bc1004789569883</originalsourceid><addsrcrecordid>eNp1kcFv0zAUhy0EYqNw54QsceESsGPHTi5I3bQBUhDSKGfrOX3pvCVxsZ2JXvjbcdVRYBKnZ9nf--znHyEvOXvLudbveCUEE1LxqmoqLfQjcrrfKpgQ9ePjWqoT8izGG8ZKpQR_Sk5KVTKllT4lP5f0EiE66waXdvRrmtc76id65WykEOlyguRH18FAW5jWI4TbSHsf6GefXOZWAbpbN22o72k755oh2ro7DHQ1jz5kSaIXPxKGKSvOEEZ6BWvn0zUG2O6ekyc9DBFf3NcF-XZ5sTr_WLRfPnw6X7ZFJ1WZClSVEgz0WjIlwDZlzSxaRA2NVEJjz7mF0speMy07VLayHWdM6rqpVFPXYkHeH7zb2Y647nBKAQazDS5PtDMenPn3ZHLXZuPvTKW44mwveHMvCP77jDGZ0cUOhwEm9HM0vM5_WzaS8Yy-foDe-Hk_fjSlLLVsVJVzWRB2oLrgYwzYHx_DmdmHax6Gm1te_T3EseF3mhkoDkCEDf659b_CXwHtrG0</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2427496553</pqid></control><display><type>article</type><title>A Feasibility Study on Ribs as Anatomical Landmarks for Motion Tracking of Lung and Liver Tumors at External Beam Radiotherapy</title><source>Sage Journals GOLD Open Access 2024</source><creator>Nankali, Saber ; Torshabi, Ahmad Esmaili ; Miandoab, Payam Samadi</creator><creatorcontrib>Nankali, Saber ; Torshabi, Ahmad Esmaili ; Miandoab, Payam Samadi</creatorcontrib><description>At external beam radiotherapy for some tumors located at thorax region due to lack of information in gray scale fluoroscopic images tumor position determination is problematic. One of the clinical strategies is to implant clip as internal fiducial marker inside or near tumor to represent tumor position while the contrast of implanted clip is highly observable rather than tumor. As alternative, using natural anatomical landmarks located at thorax region of patient body is proposed to extract tumor position information without implanting clips that is invasive method with possible side effect. Among natural landmarks, ribs of rib-cage structure that result proper visualization at X-ray images may be optimal as representative for tumor motion. In this study, we investigated the existence of possible correlation between ribs as natural anatomical landmarks and various lung and liver tumors located at different sites as challenging issue. A simulation study was performed using data extracted from 4-dimensional extended cardiac-torso anthropomorphic phantom that is able to simulate motion effect of dynamic organs, as well. Several tumor sites with predefined distances originated from chosen ribs at anterior–posterior direction were simulated at 3 upper, middle, and lower parts of chest. Correlation coefficient between ribs and tumors was calculated to investigate the robustness of ribs as anatomical landmarks for tumor motion tracking. Moreover, a consistent correlation model was taken into account to track tumor motion with a rib as best candidate among selected ribs. Final results represent availability of using rib cage as anatomical landmark to track lung and liver tumors in a noninvasive way. Observations of our calculations showed a proper correlation between tumors and ribs while the degree of this correlation is changing depends on tumor site while lung tumors are more varied and complex with less correlation with ribs motion against liver tumors.</description><identifier>ISSN: 1533-0346</identifier><identifier>EISSN: 1533-0338</identifier><identifier>DOI: 10.1177/1533034615595737</identifier><identifier>PMID: 26206767</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><subject>Algorithms ; Biomarkers ; Feasibility studies ; Humans ; Information processing ; Liver ; Liver cancer ; Liver Neoplasms - radiotherapy ; Lung cancer ; Lung Neoplasms - radiotherapy ; Models, Theoretical ; Motion ; Phantoms, Imaging ; Radiation therapy ; Radiotherapy, Image-Guided - methods ; Rib ; Ribs - anatomy &amp; histology ; Tomography, X-Ray Computed ; Tumors ; Workflow</subject><ispartof>Technology in cancer research &amp; treatment, 2017-02, Vol.16 (1), p.99-111</ispartof><rights>The Author(s) 2015</rights><rights>The Author(s) 2015. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the associated terms available at: https://uk.sagepub.com/en-gb/eur/reusing-open-access-and-sage-choice-content</rights><rights>The Author(s) 2015 2015 SAGE Publications</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c462t-e65630a7d4063ab9280bebee7a94637ef11ba2b4f7074ce6b5bc1004789569883</citedby><cites>FETCH-LOGICAL-c462t-e65630a7d4063ab9280bebee7a94637ef11ba2b4f7074ce6b5bc1004789569883</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5616108/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2427496553?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,724,777,781,882,21947,25734,27834,27905,27906,36993,36994,44571,44926,45314,53772,53774</link.rule.ids><linktorsrc>$$Uhttps://journals.sagepub.com/doi/full/10.1177/1533034615595737?utm_source=summon&amp;utm_medium=discovery-provider$$EView_record_in_SAGE_Publications$$FView_record_in_$$GSAGE_Publications</linktorsrc><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/26206767$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Nankali, Saber</creatorcontrib><creatorcontrib>Torshabi, Ahmad Esmaili</creatorcontrib><creatorcontrib>Miandoab, Payam Samadi</creatorcontrib><title>A Feasibility Study on Ribs as Anatomical Landmarks for Motion Tracking of Lung and Liver Tumors at External Beam Radiotherapy</title><title>Technology in cancer research &amp; treatment</title><addtitle>Technol Cancer Res Treat</addtitle><description>At external beam radiotherapy for some tumors located at thorax region due to lack of information in gray scale fluoroscopic images tumor position determination is problematic. One of the clinical strategies is to implant clip as internal fiducial marker inside or near tumor to represent tumor position while the contrast of implanted clip is highly observable rather than tumor. As alternative, using natural anatomical landmarks located at thorax region of patient body is proposed to extract tumor position information without implanting clips that is invasive method with possible side effect. Among natural landmarks, ribs of rib-cage structure that result proper visualization at X-ray images may be optimal as representative for tumor motion. In this study, we investigated the existence of possible correlation between ribs as natural anatomical landmarks and various lung and liver tumors located at different sites as challenging issue. A simulation study was performed using data extracted from 4-dimensional extended cardiac-torso anthropomorphic phantom that is able to simulate motion effect of dynamic organs, as well. Several tumor sites with predefined distances originated from chosen ribs at anterior–posterior direction were simulated at 3 upper, middle, and lower parts of chest. Correlation coefficient between ribs and tumors was calculated to investigate the robustness of ribs as anatomical landmarks for tumor motion tracking. Moreover, a consistent correlation model was taken into account to track tumor motion with a rib as best candidate among selected ribs. Final results represent availability of using rib cage as anatomical landmark to track lung and liver tumors in a noninvasive way. Observations of our calculations showed a proper correlation between tumors and ribs while the degree of this correlation is changing depends on tumor site while lung tumors are more varied and complex with less correlation with ribs motion against liver tumors.</description><subject>Algorithms</subject><subject>Biomarkers</subject><subject>Feasibility studies</subject><subject>Humans</subject><subject>Information processing</subject><subject>Liver</subject><subject>Liver cancer</subject><subject>Liver Neoplasms - radiotherapy</subject><subject>Lung cancer</subject><subject>Lung Neoplasms - radiotherapy</subject><subject>Models, Theoretical</subject><subject>Motion</subject><subject>Phantoms, Imaging</subject><subject>Radiation therapy</subject><subject>Radiotherapy, Image-Guided - methods</subject><subject>Rib</subject><subject>Ribs - anatomy &amp; histology</subject><subject>Tomography, X-Ray Computed</subject><subject>Tumors</subject><subject>Workflow</subject><issn>1533-0346</issn><issn>1533-0338</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNp1kcFv0zAUhy0EYqNw54QsceESsGPHTi5I3bQBUhDSKGfrOX3pvCVxsZ2JXvjbcdVRYBKnZ9nf--znHyEvOXvLudbveCUEE1LxqmoqLfQjcrrfKpgQ9ePjWqoT8izGG8ZKpQR_Sk5KVTKllT4lP5f0EiE66waXdvRrmtc76id65WykEOlyguRH18FAW5jWI4TbSHsf6GefXOZWAbpbN22o72k755oh2ro7DHQ1jz5kSaIXPxKGKSvOEEZ6BWvn0zUG2O6ekyc9DBFf3NcF-XZ5sTr_WLRfPnw6X7ZFJ1WZClSVEgz0WjIlwDZlzSxaRA2NVEJjz7mF0speMy07VLayHWdM6rqpVFPXYkHeH7zb2Y647nBKAQazDS5PtDMenPn3ZHLXZuPvTKW44mwveHMvCP77jDGZ0cUOhwEm9HM0vM5_WzaS8Yy-foDe-Hk_fjSlLLVsVJVzWRB2oLrgYwzYHx_DmdmHax6Gm1te_T3EseF3mhkoDkCEDf659b_CXwHtrG0</recordid><startdate>20170201</startdate><enddate>20170201</enddate><creator>Nankali, Saber</creator><creator>Torshabi, Ahmad Esmaili</creator><creator>Miandoab, Payam Samadi</creator><general>SAGE Publications</general><general>Sage Publications Ltd</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7TO</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>H94</scope><scope>K9.</scope><scope>M0S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20170201</creationdate><title>A Feasibility Study on Ribs as Anatomical Landmarks for Motion Tracking of Lung and Liver Tumors at External Beam Radiotherapy</title><author>Nankali, Saber ; Torshabi, Ahmad Esmaili ; Miandoab, Payam Samadi</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c462t-e65630a7d4063ab9280bebee7a94637ef11ba2b4f7074ce6b5bc1004789569883</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Algorithms</topic><topic>Biomarkers</topic><topic>Feasibility studies</topic><topic>Humans</topic><topic>Information processing</topic><topic>Liver</topic><topic>Liver cancer</topic><topic>Liver Neoplasms - radiotherapy</topic><topic>Lung cancer</topic><topic>Lung Neoplasms - radiotherapy</topic><topic>Models, Theoretical</topic><topic>Motion</topic><topic>Phantoms, Imaging</topic><topic>Radiation therapy</topic><topic>Radiotherapy, Image-Guided - methods</topic><topic>Rib</topic><topic>Ribs - anatomy &amp; histology</topic><topic>Tomography, X-Ray Computed</topic><topic>Tumors</topic><topic>Workflow</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nankali, Saber</creatorcontrib><creatorcontrib>Torshabi, Ahmad Esmaili</creatorcontrib><creatorcontrib>Miandoab, Payam Samadi</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Oncogenes and Growth Factors Abstracts</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Technology in cancer research &amp; treatment</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Nankali, Saber</au><au>Torshabi, Ahmad Esmaili</au><au>Miandoab, Payam Samadi</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Feasibility Study on Ribs as Anatomical Landmarks for Motion Tracking of Lung and Liver Tumors at External Beam Radiotherapy</atitle><jtitle>Technology in cancer research &amp; treatment</jtitle><addtitle>Technol Cancer Res Treat</addtitle><date>2017-02-01</date><risdate>2017</risdate><volume>16</volume><issue>1</issue><spage>99</spage><epage>111</epage><pages>99-111</pages><issn>1533-0346</issn><eissn>1533-0338</eissn><abstract>At external beam radiotherapy for some tumors located at thorax region due to lack of information in gray scale fluoroscopic images tumor position determination is problematic. One of the clinical strategies is to implant clip as internal fiducial marker inside or near tumor to represent tumor position while the contrast of implanted clip is highly observable rather than tumor. As alternative, using natural anatomical landmarks located at thorax region of patient body is proposed to extract tumor position information without implanting clips that is invasive method with possible side effect. Among natural landmarks, ribs of rib-cage structure that result proper visualization at X-ray images may be optimal as representative for tumor motion. In this study, we investigated the existence of possible correlation between ribs as natural anatomical landmarks and various lung and liver tumors located at different sites as challenging issue. A simulation study was performed using data extracted from 4-dimensional extended cardiac-torso anthropomorphic phantom that is able to simulate motion effect of dynamic organs, as well. Several tumor sites with predefined distances originated from chosen ribs at anterior–posterior direction were simulated at 3 upper, middle, and lower parts of chest. Correlation coefficient between ribs and tumors was calculated to investigate the robustness of ribs as anatomical landmarks for tumor motion tracking. Moreover, a consistent correlation model was taken into account to track tumor motion with a rib as best candidate among selected ribs. Final results represent availability of using rib cage as anatomical landmark to track lung and liver tumors in a noninvasive way. Observations of our calculations showed a proper correlation between tumors and ribs while the degree of this correlation is changing depends on tumor site while lung tumors are more varied and complex with less correlation with ribs motion against liver tumors.</abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>26206767</pmid><doi>10.1177/1533034615595737</doi><tpages>13</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier ISSN: 1533-0346
ispartof Technology in cancer research & treatment, 2017-02, Vol.16 (1), p.99-111
issn 1533-0346
1533-0338
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5616108
source Sage Journals GOLD Open Access 2024
subjects Algorithms
Biomarkers
Feasibility studies
Humans
Information processing
Liver
Liver cancer
Liver Neoplasms - radiotherapy
Lung cancer
Lung Neoplasms - radiotherapy
Models, Theoretical
Motion
Phantoms, Imaging
Radiation therapy
Radiotherapy, Image-Guided - methods
Rib
Ribs - anatomy & histology
Tomography, X-Ray Computed
Tumors
Workflow
title A Feasibility Study on Ribs as Anatomical Landmarks for Motion Tracking of Lung and Liver Tumors at External Beam Radiotherapy
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-18T23%3A30%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_AFRWT&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Feasibility%20Study%20on%20Ribs%20as%20Anatomical%20Landmarks%20for%20Motion%20Tracking%20of%20Lung%20and%20Liver%20Tumors%20at%20External%20Beam%20Radiotherapy&rft.jtitle=Technology%20in%20cancer%20research%20&%20treatment&rft.au=Nankali,%20Saber&rft.date=2017-02-01&rft.volume=16&rft.issue=1&rft.spage=99&rft.epage=111&rft.pages=99-111&rft.issn=1533-0346&rft.eissn=1533-0338&rft_id=info:doi/10.1177/1533034615595737&rft_dat=%3Cproquest_AFRWT%3E1826629401%3C/proquest_AFRWT%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c462t-e65630a7d4063ab9280bebee7a94637ef11ba2b4f7074ce6b5bc1004789569883%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2427496553&rft_id=info:pmid/26206767&rft_sage_id=10.1177_1533034615595737&rfr_iscdi=true