Loading…
Influence of internal fixation systems on radiation therapy for spinal tumor
In this study, the influence of internal fixation systems on radiation therapy for spinal tumor was investigated in order to derive a theoretical basis for adjustment of radiation dose for patients with spinal tumor and internal fixation. Based on a common method of internal fixation after resection...
Saved in:
Published in: | Journal of applied clinical medical physics 2015-07, Vol.16 (4), p.279-289 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | In this study, the influence of internal fixation systems on radiation therapy for spinal tumor was investigated in order to derive a theoretical basis for adjustment of radiation dose for patients with spinal tumor and internal fixation. Based on a common method of internal fixation after resection of spinal tumor, different models of spinal internal fixation were constructed using the lumbar vertebra of fresh domestic pigs and titanium alloy as the internal fixation system. Variations in radiation dose in the vertebral body and partial spinal cord in different types of internal fixation were studied under the same radiation condition (6 MV and 600 mGy) in different fixation models and compared with those irradiated based on the treatment planning system (TPS). Our results showed that spinal internal fixation materials have great impact on the radiation dose absorbed by spinal tumors. Under the same radiation condition, the influence of anterior internal fixation material or combined anterior and posterior approach on radiation dose at the anterior border of the vertebral body was the greatest. Regardless of the kinds of internal fixation method employed, radiation dose at the anterior border of the vertebral body was significantly different from that at other positions. Notably, the influence of posterior internal fixation material on the anterior wall of the vertebral canal was the greatest. X‐ray attenuation and scattering should be taken into consideration for most patients with bone metastasis that receive fixation of metal implants. Further evaluation should then be conducted with modified TPS in order to minimize the potentially harmful effects of inappropriate radiation dose.
PACS number: 87.55.D‐ |
---|---|
ISSN: | 1526-9914 1526-9914 |
DOI: | 10.1120/jacmp.v16i4.5450 |