Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging
Tissue polarimetric imaging measures Mueller matrices of tissues or Stokes vectors of the emergent light from tissues (normally using incidence with a fixed polarization state) over a field of view, and has demonstrated utility in a number of surgical and diagnostic applications. Here we introduce a...
Saved in:
Published in: | Biomedical optics express 2017-11, Vol.8 (11), p.4933-4946 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c384t-5502fee543926c7ba155aad42af18a2f5c7207882815bcd52f8b862d421244ca3 |
---|---|
cites | cdi_FETCH-LOGICAL-c384t-5502fee543926c7ba155aad42af18a2f5c7207882815bcd52f8b862d421244ca3 |
container_end_page | 4946 |
container_issue | 11 |
container_start_page | 4933 |
container_title | Biomedical optics express |
container_volume | 8 |
creator | Qi, Ji He, Chao Elson, Daniel S |
description | Tissue polarimetric imaging measures Mueller matrices of tissues or Stokes vectors of the emergent light from tissues (normally using incidence with a fixed polarization state) over a field of view, and has demonstrated utility in a number of surgical and diagnostic applications. Here we introduce a compact complete Stokes polarimetric imager that can work for multiple wavelength bands with a frame-rate suitable for real-time applications. The imager was validated with standard polarizing components, and then employed as a polarization state analyzer of a Mueller imaging polarimeter and a standalone Stokes imaging polarimeter respectively to image the process of dehydration of bovine tendon tissue. The results obtained in this work suggested that the polarization properties of the samples rich of collagen fibres can change with the degree of dehydration, and therefore, dehydration of the samples prepared for polarimetric imaging (e.g. polarimetric microscopy) should be carefully controlled. |
doi_str_mv | 10.1364/BOE.8.004933 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5695942</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1970629629</sourcerecordid><originalsourceid>FETCH-LOGICAL-c384t-5502fee543926c7ba155aad42af18a2f5c7207882815bcd52f8b862d421244ca3</originalsourceid><addsrcrecordid>eNplkV1LwzAUhoMoKnN3XksuvbAzSZM2vRF0-AXCwI_rcJqezmrbzKQb6K83simKIZDA-_CcAy8hh5xNeJrJ04vZ5URPGJNFmm6RfcFVluRMq-1f_z0yDuGFxSNlzlK9S_ZEwbVmhdgnq3uElg5Nh9S6btHigPRhcK8Y6MK14GMw-MbSpoM5elpCwIq6ngJtmx7Bb6iPmIH38E4tdOiB1s5HawhL_O9p-vkB2amhDTjevCPydHX5OL1J7mbXt9Pzu8SmWg6JUkzUiEqmhchsXgJXCqCSAmquQdTK5oLlWgvNVWkrJWpd6kxEgAspLaQjcrb2LpZlh5XFfvDQmkXcB_y7cdCYv0nfPJu5WxmVFaqQIgqONwLv3pYYBtM1wWLbQo9uGQwvcpaJIt6InqxR610IHuufMZyZr7ZMbMtos24r4ke_V_uBv7tJPwGvJpJC</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1970629629</pqid></control><display><type>article</type><title>Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging</title><source>PubMed Central</source><source>EZB Electronic Journals Library</source><creator>Qi, Ji ; He, Chao ; Elson, Daniel S</creator><creatorcontrib>Qi, Ji ; He, Chao ; Elson, Daniel S</creatorcontrib><description>Tissue polarimetric imaging measures Mueller matrices of tissues or Stokes vectors of the emergent light from tissues (normally using incidence with a fixed polarization state) over a field of view, and has demonstrated utility in a number of surgical and diagnostic applications. Here we introduce a compact complete Stokes polarimetric imager that can work for multiple wavelength bands with a frame-rate suitable for real-time applications. The imager was validated with standard polarizing components, and then employed as a polarization state analyzer of a Mueller imaging polarimeter and a standalone Stokes imaging polarimeter respectively to image the process of dehydration of bovine tendon tissue. The results obtained in this work suggested that the polarization properties of the samples rich of collagen fibres can change with the degree of dehydration, and therefore, dehydration of the samples prepared for polarimetric imaging (e.g. polarimetric microscopy) should be carefully controlled.</description><identifier>ISSN: 2156-7085</identifier><identifier>EISSN: 2156-7085</identifier><identifier>DOI: 10.1364/BOE.8.004933</identifier><identifier>PMID: 29188092</identifier><language>eng</language><publisher>United States: Optical Society of America</publisher><ispartof>Biomedical optics express, 2017-11, Vol.8 (11), p.4933-4946</ispartof><rights>Published by The Optical Society under the terms of the . Further distribution of this work must maintain attribution to the author(s) and the published article's title, journal citation, and DOI. 2017</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c384t-5502fee543926c7ba155aad42af18a2f5c7207882815bcd52f8b862d421244ca3</citedby><cites>FETCH-LOGICAL-c384t-5502fee543926c7ba155aad42af18a2f5c7207882815bcd52f8b862d421244ca3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5695942/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5695942/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29188092$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Qi, Ji</creatorcontrib><creatorcontrib>He, Chao</creatorcontrib><creatorcontrib>Elson, Daniel S</creatorcontrib><title>Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging</title><title>Biomedical optics express</title><addtitle>Biomed Opt Express</addtitle><description>Tissue polarimetric imaging measures Mueller matrices of tissues or Stokes vectors of the emergent light from tissues (normally using incidence with a fixed polarization state) over a field of view, and has demonstrated utility in a number of surgical and diagnostic applications. Here we introduce a compact complete Stokes polarimetric imager that can work for multiple wavelength bands with a frame-rate suitable for real-time applications. The imager was validated with standard polarizing components, and then employed as a polarization state analyzer of a Mueller imaging polarimeter and a standalone Stokes imaging polarimeter respectively to image the process of dehydration of bovine tendon tissue. The results obtained in this work suggested that the polarization properties of the samples rich of collagen fibres can change with the degree of dehydration, and therefore, dehydration of the samples prepared for polarimetric imaging (e.g. polarimetric microscopy) should be carefully controlled.</description><issn>2156-7085</issn><issn>2156-7085</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNplkV1LwzAUhoMoKnN3XksuvbAzSZM2vRF0-AXCwI_rcJqezmrbzKQb6K83simKIZDA-_CcAy8hh5xNeJrJ04vZ5URPGJNFmm6RfcFVluRMq-1f_z0yDuGFxSNlzlK9S_ZEwbVmhdgnq3uElg5Nh9S6btHigPRhcK8Y6MK14GMw-MbSpoM5elpCwIq6ngJtmx7Bb6iPmIH38E4tdOiB1s5HawhL_O9p-vkB2amhDTjevCPydHX5OL1J7mbXt9Pzu8SmWg6JUkzUiEqmhchsXgJXCqCSAmquQdTK5oLlWgvNVWkrJWpd6kxEgAspLaQjcrb2LpZlh5XFfvDQmkXcB_y7cdCYv0nfPJu5WxmVFaqQIgqONwLv3pYYBtM1wWLbQo9uGQwvcpaJIt6InqxR610IHuufMZyZr7ZMbMtos24r4ke_V_uBv7tJPwGvJpJC</recordid><startdate>20171101</startdate><enddate>20171101</enddate><creator>Qi, Ji</creator><creator>He, Chao</creator><creator>Elson, Daniel S</creator><general>Optical Society of America</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20171101</creationdate><title>Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging</title><author>Qi, Ji ; He, Chao ; Elson, Daniel S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c384t-5502fee543926c7ba155aad42af18a2f5c7207882815bcd52f8b862d421244ca3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Qi, Ji</creatorcontrib><creatorcontrib>He, Chao</creatorcontrib><creatorcontrib>Elson, Daniel S</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Biomedical optics express</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Qi, Ji</au><au>He, Chao</au><au>Elson, Daniel S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging</atitle><jtitle>Biomedical optics express</jtitle><addtitle>Biomed Opt Express</addtitle><date>2017-11-01</date><risdate>2017</risdate><volume>8</volume><issue>11</issue><spage>4933</spage><epage>4946</epage><pages>4933-4946</pages><issn>2156-7085</issn><eissn>2156-7085</eissn><abstract>Tissue polarimetric imaging measures Mueller matrices of tissues or Stokes vectors of the emergent light from tissues (normally using incidence with a fixed polarization state) over a field of view, and has demonstrated utility in a number of surgical and diagnostic applications. Here we introduce a compact complete Stokes polarimetric imager that can work for multiple wavelength bands with a frame-rate suitable for real-time applications. The imager was validated with standard polarizing components, and then employed as a polarization state analyzer of a Mueller imaging polarimeter and a standalone Stokes imaging polarimeter respectively to image the process of dehydration of bovine tendon tissue. The results obtained in this work suggested that the polarization properties of the samples rich of collagen fibres can change with the degree of dehydration, and therefore, dehydration of the samples prepared for polarimetric imaging (e.g. polarimetric microscopy) should be carefully controlled.</abstract><cop>United States</cop><pub>Optical Society of America</pub><pmid>29188092</pmid><doi>10.1364/BOE.8.004933</doi><tpages>14</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2156-7085 |
ispartof | Biomedical optics express, 2017-11, Vol.8 (11), p.4933-4946 |
issn | 2156-7085 2156-7085 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5695942 |
source | PubMed Central; EZB Electronic Journals Library |
title | Real time complete Stokes polarimetric imager based on a linear polarizer array camera for tissue polarimetric imaging |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T14%3A35%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Real%20time%20complete%20Stokes%20polarimetric%20imager%20based%20on%20a%20linear%20polarizer%20array%20camera%20for%20tissue%20polarimetric%20imaging&rft.jtitle=Biomedical%20optics%20express&rft.au=Qi,%20Ji&rft.date=2017-11-01&rft.volume=8&rft.issue=11&rft.spage=4933&rft.epage=4946&rft.pages=4933-4946&rft.issn=2156-7085&rft.eissn=2156-7085&rft_id=info:doi/10.1364/BOE.8.004933&rft_dat=%3Cproquest_pubme%3E1970629629%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c384t-5502fee543926c7ba155aad42af18a2f5c7207882815bcd52f8b862d421244ca3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1970629629&rft_id=info:pmid/29188092&rfr_iscdi=true |