Loading…
Walker Parameter for Mean Stress Correction in Fatigue Testing of Al-7%Si-Mg Alloy Castings
In this study, performance of two existing Walker parameter estimation models has been investigated. Results show that those developed mainly for steel did not provide reasonable fits to experimental Walker parameters for fatigue data for Al-7%Si-Mg alloy castings in the literature. A strong relatio...
Saved in:
Published in: | Materials 2017-12, Vol.10 (12), p.1401 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c378t-3ef8ccf811d673571eb945f0a67e8328501693d8f1eb57c8a6996f21f5436d333 |
---|---|
cites | cdi_FETCH-LOGICAL-c378t-3ef8ccf811d673571eb945f0a67e8328501693d8f1eb57c8a6996f21f5436d333 |
container_end_page | |
container_issue | 12 |
container_start_page | 1401 |
container_title | Materials |
container_volume | 10 |
creator | Özdeş, Hüseyin Tiryakioğlu, Murat |
description | In this study, performance of two existing Walker parameter estimation models has been investigated. Results show that those developed mainly for steel did not provide reasonable fits to experimental Walker parameters for fatigue data for Al-7%Si-Mg alloy castings in the literature. A strong relationship between the Walker parameter and the structural quality, quantified by the quality index, Q
, was observed and an empirical equation to estimate the Walker parameter for these alloys was developed. These findings indicate that the Walker parameter is not an intrinsic material property and the structural quality of the specimens must be taken into account for mean stress correction in fatigue testing. |
doi_str_mv | 10.3390/ma10121401 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5744336</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1983848244</sourcerecordid><originalsourceid>FETCH-LOGICAL-c378t-3ef8ccf811d673571eb945f0a67e8328501693d8f1eb57c8a6996f21f5436d333</originalsourceid><addsrcrecordid>eNpVUV1LwzAUDaK4MffiD5C8CCJUm960TV6EUZwKGwqb-OBDyLpkRttmJp2wf290U-e9D_fAOZz7hdAxiS8AeHxZSxKThNCY7KEu4TyLCKd0fwd3UN_71zgEAGEJP0SdhIfMadZFz0-yelMOP0gna9UGpK3DYyUbPGmd8h4X1jlVtsY22DR4KFuzWCk8Vb41zQJbjQdVlJ9OTDReBFjZNS7kN-eP0IGWlVf9be2hx-H1tLiNRvc3d8VgFJWQszYCpVlZakbIPMshzYmacZrqWGa5YpCwNCYZhznTgUjzksksbKYTolMK2RwAeuhq47tczWo1L1XTOlmJpTO1dGthpRH_mca8iIX9EGlOKUAWDM62Bs6-r8Jmoja-VFUlG2VXXhDOgFGWBHUPnW-kpbPeO6V_25BYfD1E_D0kiE92B_uV_pwfPgFiXYT8</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1983848244</pqid></control><display><type>article</type><title>Walker Parameter for Mean Stress Correction in Fatigue Testing of Al-7%Si-Mg Alloy Castings</title><source>Publicly Available Content Database</source><source>Full-Text Journals in Chemistry (Open access)</source><source>PubMed Central</source><creator>Özdeş, Hüseyin ; Tiryakioğlu, Murat</creator><creatorcontrib>Özdeş, Hüseyin ; Tiryakioğlu, Murat</creatorcontrib><description>In this study, performance of two existing Walker parameter estimation models has been investigated. Results show that those developed mainly for steel did not provide reasonable fits to experimental Walker parameters for fatigue data for Al-7%Si-Mg alloy castings in the literature. A strong relationship between the Walker parameter and the structural quality, quantified by the quality index, Q
, was observed and an empirical equation to estimate the Walker parameter for these alloys was developed. These findings indicate that the Walker parameter is not an intrinsic material property and the structural quality of the specimens must be taken into account for mean stress correction in fatigue testing.</description><identifier>ISSN: 1996-1944</identifier><identifier>EISSN: 1996-1944</identifier><identifier>DOI: 10.3390/ma10121401</identifier><identifier>PMID: 29292746</identifier><language>eng</language><publisher>Switzerland: MDPI</publisher><ispartof>Materials, 2017-12, Vol.10 (12), p.1401</ispartof><rights>2017 by the authors. 2017</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c378t-3ef8ccf811d673571eb945f0a67e8328501693d8f1eb57c8a6996f21f5436d333</citedby><cites>FETCH-LOGICAL-c378t-3ef8ccf811d673571eb945f0a67e8328501693d8f1eb57c8a6996f21f5436d333</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5744336/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5744336/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27923,27924,37012,53790,53792</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29292746$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Özdeş, Hüseyin</creatorcontrib><creatorcontrib>Tiryakioğlu, Murat</creatorcontrib><title>Walker Parameter for Mean Stress Correction in Fatigue Testing of Al-7%Si-Mg Alloy Castings</title><title>Materials</title><addtitle>Materials (Basel)</addtitle><description>In this study, performance of two existing Walker parameter estimation models has been investigated. Results show that those developed mainly for steel did not provide reasonable fits to experimental Walker parameters for fatigue data for Al-7%Si-Mg alloy castings in the literature. A strong relationship between the Walker parameter and the structural quality, quantified by the quality index, Q
, was observed and an empirical equation to estimate the Walker parameter for these alloys was developed. These findings indicate that the Walker parameter is not an intrinsic material property and the structural quality of the specimens must be taken into account for mean stress correction in fatigue testing.</description><issn>1996-1944</issn><issn>1996-1944</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNpVUV1LwzAUDaK4MffiD5C8CCJUm960TV6EUZwKGwqb-OBDyLpkRttmJp2wf290U-e9D_fAOZz7hdAxiS8AeHxZSxKThNCY7KEu4TyLCKd0fwd3UN_71zgEAGEJP0SdhIfMadZFz0-yelMOP0gna9UGpK3DYyUbPGmd8h4X1jlVtsY22DR4KFuzWCk8Vb41zQJbjQdVlJ9OTDReBFjZNS7kN-eP0IGWlVf9be2hx-H1tLiNRvc3d8VgFJWQszYCpVlZakbIPMshzYmacZrqWGa5YpCwNCYZhznTgUjzksksbKYTolMK2RwAeuhq47tczWo1L1XTOlmJpTO1dGthpRH_mca8iIX9EGlOKUAWDM62Bs6-r8Jmoja-VFUlG2VXXhDOgFGWBHUPnW-kpbPeO6V_25BYfD1E_D0kiE92B_uV_pwfPgFiXYT8</recordid><startdate>20171208</startdate><enddate>20171208</enddate><creator>Özdeş, Hüseyin</creator><creator>Tiryakioğlu, Murat</creator><general>MDPI</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20171208</creationdate><title>Walker Parameter for Mean Stress Correction in Fatigue Testing of Al-7%Si-Mg Alloy Castings</title><author>Özdeş, Hüseyin ; Tiryakioğlu, Murat</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c378t-3ef8ccf811d673571eb945f0a67e8328501693d8f1eb57c8a6996f21f5436d333</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Özdeş, Hüseyin</creatorcontrib><creatorcontrib>Tiryakioğlu, Murat</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Özdeş, Hüseyin</au><au>Tiryakioğlu, Murat</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Walker Parameter for Mean Stress Correction in Fatigue Testing of Al-7%Si-Mg Alloy Castings</atitle><jtitle>Materials</jtitle><addtitle>Materials (Basel)</addtitle><date>2017-12-08</date><risdate>2017</risdate><volume>10</volume><issue>12</issue><spage>1401</spage><pages>1401-</pages><issn>1996-1944</issn><eissn>1996-1944</eissn><abstract>In this study, performance of two existing Walker parameter estimation models has been investigated. Results show that those developed mainly for steel did not provide reasonable fits to experimental Walker parameters for fatigue data for Al-7%Si-Mg alloy castings in the literature. A strong relationship between the Walker parameter and the structural quality, quantified by the quality index, Q
, was observed and an empirical equation to estimate the Walker parameter for these alloys was developed. These findings indicate that the Walker parameter is not an intrinsic material property and the structural quality of the specimens must be taken into account for mean stress correction in fatigue testing.</abstract><cop>Switzerland</cop><pub>MDPI</pub><pmid>29292746</pmid><doi>10.3390/ma10121401</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1996-1944 |
ispartof | Materials, 2017-12, Vol.10 (12), p.1401 |
issn | 1996-1944 1996-1944 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5744336 |
source | Publicly Available Content Database; Full-Text Journals in Chemistry (Open access); PubMed Central |
title | Walker Parameter for Mean Stress Correction in Fatigue Testing of Al-7%Si-Mg Alloy Castings |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T21%3A56%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Walker%20Parameter%20for%20Mean%20Stress%20Correction%20in%20Fatigue%20Testing%20of%20Al-7%25Si-Mg%20Alloy%20Castings&rft.jtitle=Materials&rft.au=%C3%96zde%C5%9F,%20H%C3%BCseyin&rft.date=2017-12-08&rft.volume=10&rft.issue=12&rft.spage=1401&rft.pages=1401-&rft.issn=1996-1944&rft.eissn=1996-1944&rft_id=info:doi/10.3390/ma10121401&rft_dat=%3Cproquest_pubme%3E1983848244%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c378t-3ef8ccf811d673571eb945f0a67e8328501693d8f1eb57c8a6996f21f5436d333%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=1983848244&rft_id=info:pmid/29292746&rfr_iscdi=true |