Regional variations in baseline characteristics of cardiac rhythm device recipients: The PANORAMA observational cohort study

Abstract Background The PANORAMA study was designed to collect concurrent data on subjects from different worldwide regions implanted with CRM devices. Methods In this prospective, multi-center study, we analyzed baseline data on 8586 subjects implanted with CRM devices with no additional selection...

Full description

Saved in:
Bibliographic Details
Published in:International journal of cardiology. Heart & vessels 2014-09, Vol.4, p.90-96
Main Authors: Al Kandari, Fawziah, Erglis, Andrejs, Sweidan, Raed, Dannheimer, Ingrid, Sepsi, Milan, Bénézet, Juan, Padour, Michal, Naik, Ajay, Escudero, Jaime, West, Teena, Holbrook, Reece, Lorgat, Faizel
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c4998-bfbea552598ccb4c72b40308c9030fbff562de53bd8cae749e4defadc53f6ed03
cites cdi_FETCH-LOGICAL-c4998-bfbea552598ccb4c72b40308c9030fbff562de53bd8cae749e4defadc53f6ed03
container_end_page 96
container_issue
container_start_page 90
container_title International journal of cardiology. Heart & vessels
container_volume 4
creator Al Kandari, Fawziah
Erglis, Andrejs
Sweidan, Raed
Dannheimer, Ingrid
Sepsi, Milan
Bénézet, Juan
Padour, Michal
Naik, Ajay
Escudero, Jaime
West, Teena
Holbrook, Reece
Lorgat, Faizel
description Abstract Background The PANORAMA study was designed to collect concurrent data on subjects from different worldwide regions implanted with CRM devices. Methods In this prospective, multi-center study, we analyzed baseline data on 8586 subjects implanted with CRM devices with no additional selection criteria (66% pacemaker (IPG), 16% implantable cardiac defibrillators (ICD), 17% cardiac resynchronization therapy (CRT) and < 1% Internal Loop Recorder) from 156 hospitals across 6 geographical regions between 2005 and 2011. Results Regardless of the device implanted, subjects from the Middle East and India often had more diabetes than other regions. Eastern and Western Europe had higher rates of atrial fibrillation reported, and men were more likely to smoke than women (46% vs 11%, p < 0.001). Within the CRT cohort there was significant variation in the proportion of males receiving a device, ranging from 55% in India to 83% in Eastern Europe. Conclusions We provide comprehensive descriptive data on patients receiving CRM devices from a range of geographies that are not typically reported in literature. We found significant variations in clinical characteristics and implant practices. Long term follow-up data will help evaluate if these variations require adjustments to outcome expectations.
doi_str_mv 10.1016/j.ijchv.2014.06.008
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5801449</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S2214763214000479</els_id><sourcerecordid>2003038145</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4998-bfbea552598ccb4c72b40308c9030fbff562de53bd8cae749e4defadc53f6ed03</originalsourceid><addsrcrecordid>eNqFkk9r3DAQxU1paUKaT1AoOvayriRLXrvQwBL6D9KmpOlZyKNxPFuvtZFsw0I_fLXZNKS99CIJ9ObN8H6TZS8FzwUX5Zt1Tmvo5lxyoXJe5pxXT7JjKYVaLMtCPn30PspOY1xzzoUWQqjqeXYka6W5qMrj7NcV3pAfbM9mG8iO6R0ZDayxEXsakEFng4URA8WRIDLfMrDBkQUWut3YbZjDmQBZQKAt4TDGt-y6Q_Zt9fXyavVlxXwTMcx31qkN-M6HkcVxcrsX2bPW9hFP7--T7MeH99fnnxYXlx8_n68uFqDqulo0bYNWa6nrCqBRsJSN4gWvoE5n27StLqVDXTSuAotLVaNy2FoHumhLdLw4yc4Ovtup2aCDNGSwvdkG2tiwM96S-ftnoM7c-NnoKsWr6mTw-t4g-NsJ42g2FAH73g7op2gkT5MUlVA6SYuDFIKPMWD70EZws0dn1uYOndmjM7w0CV2qevV4woeaP6CS4N1BgCmnmTCYCClsQEcp-NE4T_9pcPZPPSS8BLb_iTuMaz-FRCcaYaI03Hzfb89-eYRKi6OWdfEbSdzEOA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2003038145</pqid></control><display><type>article</type><title>Regional variations in baseline characteristics of cardiac rhythm device recipients: The PANORAMA observational cohort study</title><source>PMC (PubMed Central)</source><source>ScienceDirect Journals</source><creator>Al Kandari, Fawziah ; Erglis, Andrejs ; Sweidan, Raed ; Dannheimer, Ingrid ; Sepsi, Milan ; Bénézet, Juan ; Padour, Michal ; Naik, Ajay ; Escudero, Jaime ; West, Teena ; Holbrook, Reece ; Lorgat, Faizel</creator><creatorcontrib>Al Kandari, Fawziah ; Erglis, Andrejs ; Sweidan, Raed ; Dannheimer, Ingrid ; Sepsi, Milan ; Bénézet, Juan ; Padour, Michal ; Naik, Ajay ; Escudero, Jaime ; West, Teena ; Holbrook, Reece ; Lorgat, Faizel ; On behalf of the PANORAMA investigators ; PANORAMA investigators</creatorcontrib><description>Abstract Background The PANORAMA study was designed to collect concurrent data on subjects from different worldwide regions implanted with CRM devices. Methods In this prospective, multi-center study, we analyzed baseline data on 8586 subjects implanted with CRM devices with no additional selection criteria (66% pacemaker (IPG), 16% implantable cardiac defibrillators (ICD), 17% cardiac resynchronization therapy (CRT) and &lt; 1% Internal Loop Recorder) from 156 hospitals across 6 geographical regions between 2005 and 2011. Results Regardless of the device implanted, subjects from the Middle East and India often had more diabetes than other regions. Eastern and Western Europe had higher rates of atrial fibrillation reported, and men were more likely to smoke than women (46% vs 11%, p &lt; 0.001). Within the CRT cohort there was significant variation in the proportion of males receiving a device, ranging from 55% in India to 83% in Eastern Europe. Conclusions We provide comprehensive descriptive data on patients receiving CRM devices from a range of geographies that are not typically reported in literature. We found significant variations in clinical characteristics and implant practices. Long term follow-up data will help evaluate if these variations require adjustments to outcome expectations.</description><identifier>ISSN: 2214-7632</identifier><identifier>EISSN: 2214-7632</identifier><identifier>DOI: 10.1016/j.ijchv.2014.06.008</identifier><identifier>PMID: 29450186</identifier><language>eng</language><publisher>Ireland: Elsevier Ireland Ltd</publisher><subject>Bradyarrhythmias ; Cardiac pacing ; Cardiac resynchronization ; Cardiovascular ; Defibrillators ; Heart failure ; Tachyarrhythmias</subject><ispartof>International journal of cardiology. Heart &amp; vessels, 2014-09, Vol.4, p.90-96</ispartof><rights>2014 The Authors</rights><rights>2014 The Authors 2014</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4998-bfbea552598ccb4c72b40308c9030fbff562de53bd8cae749e4defadc53f6ed03</citedby><cites>FETCH-LOGICAL-c4998-bfbea552598ccb4c72b40308c9030fbff562de53bd8cae749e4defadc53f6ed03</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5801449/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.sciencedirect.com/science/article/pii/S2214763214000479$$EHTML$$P50$$Gelsevier$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,3548,27923,27924,45779,53790,53792</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29450186$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Al Kandari, Fawziah</creatorcontrib><creatorcontrib>Erglis, Andrejs</creatorcontrib><creatorcontrib>Sweidan, Raed</creatorcontrib><creatorcontrib>Dannheimer, Ingrid</creatorcontrib><creatorcontrib>Sepsi, Milan</creatorcontrib><creatorcontrib>Bénézet, Juan</creatorcontrib><creatorcontrib>Padour, Michal</creatorcontrib><creatorcontrib>Naik, Ajay</creatorcontrib><creatorcontrib>Escudero, Jaime</creatorcontrib><creatorcontrib>West, Teena</creatorcontrib><creatorcontrib>Holbrook, Reece</creatorcontrib><creatorcontrib>Lorgat, Faizel</creatorcontrib><creatorcontrib>On behalf of the PANORAMA investigators</creatorcontrib><creatorcontrib>PANORAMA investigators</creatorcontrib><title>Regional variations in baseline characteristics of cardiac rhythm device recipients: The PANORAMA observational cohort study</title><title>International journal of cardiology. Heart &amp; vessels</title><addtitle>Int J Cardiol Heart Vessel</addtitle><description>Abstract Background The PANORAMA study was designed to collect concurrent data on subjects from different worldwide regions implanted with CRM devices. Methods In this prospective, multi-center study, we analyzed baseline data on 8586 subjects implanted with CRM devices with no additional selection criteria (66% pacemaker (IPG), 16% implantable cardiac defibrillators (ICD), 17% cardiac resynchronization therapy (CRT) and &lt; 1% Internal Loop Recorder) from 156 hospitals across 6 geographical regions between 2005 and 2011. Results Regardless of the device implanted, subjects from the Middle East and India often had more diabetes than other regions. Eastern and Western Europe had higher rates of atrial fibrillation reported, and men were more likely to smoke than women (46% vs 11%, p &lt; 0.001). Within the CRT cohort there was significant variation in the proportion of males receiving a device, ranging from 55% in India to 83% in Eastern Europe. Conclusions We provide comprehensive descriptive data on patients receiving CRM devices from a range of geographies that are not typically reported in literature. We found significant variations in clinical characteristics and implant practices. Long term follow-up data will help evaluate if these variations require adjustments to outcome expectations.</description><subject>Bradyarrhythmias</subject><subject>Cardiac pacing</subject><subject>Cardiac resynchronization</subject><subject>Cardiovascular</subject><subject>Defibrillators</subject><subject>Heart failure</subject><subject>Tachyarrhythmias</subject><issn>2214-7632</issn><issn>2214-7632</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNqFkk9r3DAQxU1paUKaT1AoOvayriRLXrvQwBL6D9KmpOlZyKNxPFuvtZFsw0I_fLXZNKS99CIJ9ObN8H6TZS8FzwUX5Zt1Tmvo5lxyoXJe5pxXT7JjKYVaLMtCPn30PspOY1xzzoUWQqjqeXYka6W5qMrj7NcV3pAfbM9mG8iO6R0ZDayxEXsakEFng4URA8WRIDLfMrDBkQUWut3YbZjDmQBZQKAt4TDGt-y6Q_Zt9fXyavVlxXwTMcx31qkN-M6HkcVxcrsX2bPW9hFP7--T7MeH99fnnxYXlx8_n68uFqDqulo0bYNWa6nrCqBRsJSN4gWvoE5n27StLqVDXTSuAotLVaNy2FoHumhLdLw4yc4Ovtup2aCDNGSwvdkG2tiwM96S-ftnoM7c-NnoKsWr6mTw-t4g-NsJ42g2FAH73g7op2gkT5MUlVA6SYuDFIKPMWD70EZws0dn1uYOndmjM7w0CV2qevV4woeaP6CS4N1BgCmnmTCYCClsQEcp-NE4T_9pcPZPPSS8BLb_iTuMaz-FRCcaYaI03Hzfb89-eYRKi6OWdfEbSdzEOA</recordid><startdate>201409</startdate><enddate>201409</enddate><creator>Al Kandari, Fawziah</creator><creator>Erglis, Andrejs</creator><creator>Sweidan, Raed</creator><creator>Dannheimer, Ingrid</creator><creator>Sepsi, Milan</creator><creator>Bénézet, Juan</creator><creator>Padour, Michal</creator><creator>Naik, Ajay</creator><creator>Escudero, Jaime</creator><creator>West, Teena</creator><creator>Holbrook, Reece</creator><creator>Lorgat, Faizel</creator><general>Elsevier Ireland Ltd</general><general>Elsevier</general><scope>6I.</scope><scope>AAFTH</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>201409</creationdate><title>Regional variations in baseline characteristics of cardiac rhythm device recipients: The PANORAMA observational cohort study</title><author>Al Kandari, Fawziah ; Erglis, Andrejs ; Sweidan, Raed ; Dannheimer, Ingrid ; Sepsi, Milan ; Bénézet, Juan ; Padour, Michal ; Naik, Ajay ; Escudero, Jaime ; West, Teena ; Holbrook, Reece ; Lorgat, Faizel</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4998-bfbea552598ccb4c72b40308c9030fbff562de53bd8cae749e4defadc53f6ed03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Bradyarrhythmias</topic><topic>Cardiac pacing</topic><topic>Cardiac resynchronization</topic><topic>Cardiovascular</topic><topic>Defibrillators</topic><topic>Heart failure</topic><topic>Tachyarrhythmias</topic><toplevel>online_resources</toplevel><creatorcontrib>Al Kandari, Fawziah</creatorcontrib><creatorcontrib>Erglis, Andrejs</creatorcontrib><creatorcontrib>Sweidan, Raed</creatorcontrib><creatorcontrib>Dannheimer, Ingrid</creatorcontrib><creatorcontrib>Sepsi, Milan</creatorcontrib><creatorcontrib>Bénézet, Juan</creatorcontrib><creatorcontrib>Padour, Michal</creatorcontrib><creatorcontrib>Naik, Ajay</creatorcontrib><creatorcontrib>Escudero, Jaime</creatorcontrib><creatorcontrib>West, Teena</creatorcontrib><creatorcontrib>Holbrook, Reece</creatorcontrib><creatorcontrib>Lorgat, Faizel</creatorcontrib><creatorcontrib>On behalf of the PANORAMA investigators</creatorcontrib><creatorcontrib>PANORAMA investigators</creatorcontrib><collection>ScienceDirect Open Access Titles</collection><collection>Elsevier:ScienceDirect:Open Access</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>International journal of cardiology. Heart &amp; vessels</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Al Kandari, Fawziah</au><au>Erglis, Andrejs</au><au>Sweidan, Raed</au><au>Dannheimer, Ingrid</au><au>Sepsi, Milan</au><au>Bénézet, Juan</au><au>Padour, Michal</au><au>Naik, Ajay</au><au>Escudero, Jaime</au><au>West, Teena</au><au>Holbrook, Reece</au><au>Lorgat, Faizel</au><aucorp>On behalf of the PANORAMA investigators</aucorp><aucorp>PANORAMA investigators</aucorp><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Regional variations in baseline characteristics of cardiac rhythm device recipients: The PANORAMA observational cohort study</atitle><jtitle>International journal of cardiology. Heart &amp; vessels</jtitle><addtitle>Int J Cardiol Heart Vessel</addtitle><date>2014-09</date><risdate>2014</risdate><volume>4</volume><spage>90</spage><epage>96</epage><pages>90-96</pages><issn>2214-7632</issn><eissn>2214-7632</eissn><abstract>Abstract Background The PANORAMA study was designed to collect concurrent data on subjects from different worldwide regions implanted with CRM devices. Methods In this prospective, multi-center study, we analyzed baseline data on 8586 subjects implanted with CRM devices with no additional selection criteria (66% pacemaker (IPG), 16% implantable cardiac defibrillators (ICD), 17% cardiac resynchronization therapy (CRT) and &lt; 1% Internal Loop Recorder) from 156 hospitals across 6 geographical regions between 2005 and 2011. Results Regardless of the device implanted, subjects from the Middle East and India often had more diabetes than other regions. Eastern and Western Europe had higher rates of atrial fibrillation reported, and men were more likely to smoke than women (46% vs 11%, p &lt; 0.001). Within the CRT cohort there was significant variation in the proportion of males receiving a device, ranging from 55% in India to 83% in Eastern Europe. Conclusions We provide comprehensive descriptive data on patients receiving CRM devices from a range of geographies that are not typically reported in literature. We found significant variations in clinical characteristics and implant practices. Long term follow-up data will help evaluate if these variations require adjustments to outcome expectations.</abstract><cop>Ireland</cop><pub>Elsevier Ireland Ltd</pub><pmid>29450186</pmid><doi>10.1016/j.ijchv.2014.06.008</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2214-7632
ispartof International journal of cardiology. Heart & vessels, 2014-09, Vol.4, p.90-96
issn 2214-7632
2214-7632
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5801449
source PMC (PubMed Central); ScienceDirect Journals
subjects Bradyarrhythmias
Cardiac pacing
Cardiac resynchronization
Cardiovascular
Defibrillators
Heart failure
Tachyarrhythmias
title Regional variations in baseline characteristics of cardiac rhythm device recipients: The PANORAMA observational cohort study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T17%3A41%3A10IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Regional%20variations%20in%20baseline%20characteristics%20of%20cardiac%20rhythm%20device%20recipients:%20The%20PANORAMA%20observational%20cohort%20study&rft.jtitle=International%20journal%20of%20cardiology.%20Heart%20&%20vessels&rft.au=Al%20Kandari,%20Fawziah&rft.aucorp=On%20behalf%20of%20the%20PANORAMA%20investigators&rft.date=2014-09&rft.volume=4&rft.spage=90&rft.epage=96&rft.pages=90-96&rft.issn=2214-7632&rft.eissn=2214-7632&rft_id=info:doi/10.1016/j.ijchv.2014.06.008&rft_dat=%3Cproquest_pubme%3E2003038145%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4998-bfbea552598ccb4c72b40308c9030fbff562de53bd8cae749e4defadc53f6ed03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2003038145&rft_id=info:pmid/29450186&rfr_iscdi=true