Loading…

High accuracy dosimetry with small pieces of Gafchromic films

To investigate the influence of several factors on the accuracy of dose measurements and feasibility of application of small Gafchromic detectors for postal audit. Our experience showed that precision of dose measurements with small pieces of Gafchromic films may be significantly improved. Gafchromi...

Full description

Saved in:
Bibliographic Details
Published in:Reports of practical oncology and radiotherapy 2018-03, Vol.23 (2), p.114-120
Main Authors: Dąbrowski, Ryszard, Drozdyk, Izabela, Kukołowicz, Paweł
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c455t-f1fd3f0ed4c7f56d2540291ce691a10f9ed6ee082373435938380467a2f7f8b93
cites cdi_FETCH-LOGICAL-c455t-f1fd3f0ed4c7f56d2540291ce691a10f9ed6ee082373435938380467a2f7f8b93
container_end_page 120
container_issue 2
container_start_page 114
container_title Reports of practical oncology and radiotherapy
container_volume 23
creator Dąbrowski, Ryszard
Drozdyk, Izabela
Kukołowicz, Paweł
description To investigate the influence of several factors on the accuracy of dose measurements and feasibility of application of small Gafchromic detectors for postal audit. Our experience showed that precision of dose measurements with small pieces of Gafchromic films may be significantly improved. Gafchromic films with dimensions of 1×1, 2×2 and 3×3cm2 were exposed to 6MV X-rays at dose levels of 50cGy-210cGy. The single- and multichannel methods (MM) were used for dose measurements. Detectors were scanned with an Epson V750PRO flatbed colour scanner. For 1×1 and larger detector sizes, separate calibration curves were established. The influence of the following factors was investigated: the heterogeneity of Gafchromic detectors group for single- and MM, ambient thermal detector conditions, the dose delivered on the measurement accuracy, application of two separate calibration curves for the smallest and larger pieces of films. The MM improves significantly the precision of dose measurement. The uncertainty attributed to detector active layer differences and scanner instabilities was about 1cGy (1 StDev) regardless of dose and detector size. The ambient temperature of the environment in which films were stored after irradiation influenced the dose reading. Significant difference of transmission for detectors sized 1×1 and 2×2cm2 was observed. The maximal difference between applied dose and dose reading performed was 1.1%. The MM with a scaling protocol leads to a very high precision of dose measurements. The ambient thermal detector environment causes significant changes of measured signal. The detector size has relevant impact on dose reading.
doi_str_mv 10.1016/j.rpor.2018.01.001
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5908271</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S1507136718300142</els_id><sourcerecordid>2029648152</sourcerecordid><originalsourceid>FETCH-LOGICAL-c455t-f1fd3f0ed4c7f56d2540291ce691a10f9ed6ee082373435938380467a2f7f8b93</originalsourceid><addsrcrecordid>eNp9kE1LHEEQhptgiIvxD-QQ5uhlxqr-nAENiCQaEHJJzk3bU-32MrO9ds8q---dZVWSS-pSh3rrqeJh7AtCg4D6fNXkTcoNB2wbwAYAP7AFh1bUUks4YgtUYGoU2hyz01JWsC8DXJlP7Jh3ukVj5IJd3saHZeW832bnd1WfShxpyrvqOU7LqoxuGKpNJE-lSqG6ccEvcxqjr0IcxvKZfQxuKHT62k_Ynx_ff1_f1ne_bn5eX93VXio11QFDLwJQL70JSvdcSeAdetIdOoTQUa-JoOXCCClUJ1rRgtTG8WBCe9-JE_btwN1s70fqPa2n7Aa7yXF0eWeTi_bfyTou7UN6sqqbqQZnwNkrIKfHLZXJjrF4Gga3prQtls__aNmi4nOUH6I-p1IyhfczCHav3q7sXr3dq7eAdlY_L339-8H3lTfRc-DiEKBZ01OkbIuPtPbUx0x-sn2K_-O_AA6olS0</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2029648152</pqid></control><display><type>article</type><title>High accuracy dosimetry with small pieces of Gafchromic films</title><source>NCBI_PubMed Central(免费)</source><creator>Dąbrowski, Ryszard ; Drozdyk, Izabela ; Kukołowicz, Paweł</creator><creatorcontrib>Dąbrowski, Ryszard ; Drozdyk, Izabela ; Kukołowicz, Paweł</creatorcontrib><description>To investigate the influence of several factors on the accuracy of dose measurements and feasibility of application of small Gafchromic detectors for postal audit. Our experience showed that precision of dose measurements with small pieces of Gafchromic films may be significantly improved. Gafchromic films with dimensions of 1×1, 2×2 and 3×3cm2 were exposed to 6MV X-rays at dose levels of 50cGy-210cGy. The single- and multichannel methods (MM) were used for dose measurements. Detectors were scanned with an Epson V750PRO flatbed colour scanner. For 1×1 and larger detector sizes, separate calibration curves were established. The influence of the following factors was investigated: the heterogeneity of Gafchromic detectors group for single- and MM, ambient thermal detector conditions, the dose delivered on the measurement accuracy, application of two separate calibration curves for the smallest and larger pieces of films. The MM improves significantly the precision of dose measurement. The uncertainty attributed to detector active layer differences and scanner instabilities was about 1cGy (1 StDev) regardless of dose and detector size. The ambient temperature of the environment in which films were stored after irradiation influenced the dose reading. Significant difference of transmission for detectors sized 1×1 and 2×2cm2 was observed. The maximal difference between applied dose and dose reading performed was 1.1%. The MM with a scaling protocol leads to a very high precision of dose measurements. The ambient thermal detector environment causes significant changes of measured signal. The detector size has relevant impact on dose reading.</description><identifier>ISSN: 1507-1367</identifier><identifier>EISSN: 2083-4640</identifier><identifier>DOI: 10.1016/j.rpor.2018.01.001</identifier><identifier>PMID: 29681774</identifier><language>eng</language><publisher>Poland: Elsevier Urban &amp; Partner Sp. z o.o</publisher><subject>Gafchromic films ; High precision measurements ; Multichannel method ; Original research article ; Postal dosimetry audit</subject><ispartof>Reports of practical oncology and radiotherapy, 2018-03, Vol.23 (2), p.114-120</ispartof><rights>2018 Greater Poland Cancer Centre</rights><rights>2018 Greater Poland Cancer Centre. Published by Elsevier Sp. z o.o. All rights reserved. 2018 Greater Poland Cancer Centre</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c455t-f1fd3f0ed4c7f56d2540291ce691a10f9ed6ee082373435938380467a2f7f8b93</citedby><cites>FETCH-LOGICAL-c455t-f1fd3f0ed4c7f56d2540291ce691a10f9ed6ee082373435938380467a2f7f8b93</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5908271/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5908271/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,723,776,780,881,27903,27904,53769,53771</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29681774$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Dąbrowski, Ryszard</creatorcontrib><creatorcontrib>Drozdyk, Izabela</creatorcontrib><creatorcontrib>Kukołowicz, Paweł</creatorcontrib><title>High accuracy dosimetry with small pieces of Gafchromic films</title><title>Reports of practical oncology and radiotherapy</title><addtitle>Rep Pract Oncol Radiother</addtitle><description>To investigate the influence of several factors on the accuracy of dose measurements and feasibility of application of small Gafchromic detectors for postal audit. Our experience showed that precision of dose measurements with small pieces of Gafchromic films may be significantly improved. Gafchromic films with dimensions of 1×1, 2×2 and 3×3cm2 were exposed to 6MV X-rays at dose levels of 50cGy-210cGy. The single- and multichannel methods (MM) were used for dose measurements. Detectors were scanned with an Epson V750PRO flatbed colour scanner. For 1×1 and larger detector sizes, separate calibration curves were established. The influence of the following factors was investigated: the heterogeneity of Gafchromic detectors group for single- and MM, ambient thermal detector conditions, the dose delivered on the measurement accuracy, application of two separate calibration curves for the smallest and larger pieces of films. The MM improves significantly the precision of dose measurement. The uncertainty attributed to detector active layer differences and scanner instabilities was about 1cGy (1 StDev) regardless of dose and detector size. The ambient temperature of the environment in which films were stored after irradiation influenced the dose reading. Significant difference of transmission for detectors sized 1×1 and 2×2cm2 was observed. The maximal difference between applied dose and dose reading performed was 1.1%. The MM with a scaling protocol leads to a very high precision of dose measurements. The ambient thermal detector environment causes significant changes of measured signal. The detector size has relevant impact on dose reading.</description><subject>Gafchromic films</subject><subject>High precision measurements</subject><subject>Multichannel method</subject><subject>Original research article</subject><subject>Postal dosimetry audit</subject><issn>1507-1367</issn><issn>2083-4640</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LHEEQhptgiIvxD-QQ5uhlxqr-nAENiCQaEHJJzk3bU-32MrO9ds8q---dZVWSS-pSh3rrqeJh7AtCg4D6fNXkTcoNB2wbwAYAP7AFh1bUUks4YgtUYGoU2hyz01JWsC8DXJlP7Jh3ukVj5IJd3saHZeW832bnd1WfShxpyrvqOU7LqoxuGKpNJE-lSqG6ccEvcxqjr0IcxvKZfQxuKHT62k_Ynx_ff1_f1ne_bn5eX93VXio11QFDLwJQL70JSvdcSeAdetIdOoTQUa-JoOXCCClUJ1rRgtTG8WBCe9-JE_btwN1s70fqPa2n7Aa7yXF0eWeTi_bfyTou7UN6sqqbqQZnwNkrIKfHLZXJjrF4Gga3prQtls__aNmi4nOUH6I-p1IyhfczCHav3q7sXr3dq7eAdlY_L339-8H3lTfRc-DiEKBZ01OkbIuPtPbUx0x-sn2K_-O_AA6olS0</recordid><startdate>20180301</startdate><enddate>20180301</enddate><creator>Dąbrowski, Ryszard</creator><creator>Drozdyk, Izabela</creator><creator>Kukołowicz, Paweł</creator><general>Elsevier Urban &amp; Partner Sp. z o.o</general><general>Elsevier</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20180301</creationdate><title>High accuracy dosimetry with small pieces of Gafchromic films</title><author>Dąbrowski, Ryszard ; Drozdyk, Izabela ; Kukołowicz, Paweł</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c455t-f1fd3f0ed4c7f56d2540291ce691a10f9ed6ee082373435938380467a2f7f8b93</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Gafchromic films</topic><topic>High precision measurements</topic><topic>Multichannel method</topic><topic>Original research article</topic><topic>Postal dosimetry audit</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Dąbrowski, Ryszard</creatorcontrib><creatorcontrib>Drozdyk, Izabela</creatorcontrib><creatorcontrib>Kukołowicz, Paweł</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Reports of practical oncology and radiotherapy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Dąbrowski, Ryszard</au><au>Drozdyk, Izabela</au><au>Kukołowicz, Paweł</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High accuracy dosimetry with small pieces of Gafchromic films</atitle><jtitle>Reports of practical oncology and radiotherapy</jtitle><addtitle>Rep Pract Oncol Radiother</addtitle><date>2018-03-01</date><risdate>2018</risdate><volume>23</volume><issue>2</issue><spage>114</spage><epage>120</epage><pages>114-120</pages><issn>1507-1367</issn><eissn>2083-4640</eissn><abstract>To investigate the influence of several factors on the accuracy of dose measurements and feasibility of application of small Gafchromic detectors for postal audit. Our experience showed that precision of dose measurements with small pieces of Gafchromic films may be significantly improved. Gafchromic films with dimensions of 1×1, 2×2 and 3×3cm2 were exposed to 6MV X-rays at dose levels of 50cGy-210cGy. The single- and multichannel methods (MM) were used for dose measurements. Detectors were scanned with an Epson V750PRO flatbed colour scanner. For 1×1 and larger detector sizes, separate calibration curves were established. The influence of the following factors was investigated: the heterogeneity of Gafchromic detectors group for single- and MM, ambient thermal detector conditions, the dose delivered on the measurement accuracy, application of two separate calibration curves for the smallest and larger pieces of films. The MM improves significantly the precision of dose measurement. The uncertainty attributed to detector active layer differences and scanner instabilities was about 1cGy (1 StDev) regardless of dose and detector size. The ambient temperature of the environment in which films were stored after irradiation influenced the dose reading. Significant difference of transmission for detectors sized 1×1 and 2×2cm2 was observed. The maximal difference between applied dose and dose reading performed was 1.1%. The MM with a scaling protocol leads to a very high precision of dose measurements. The ambient thermal detector environment causes significant changes of measured signal. The detector size has relevant impact on dose reading.</abstract><cop>Poland</cop><pub>Elsevier Urban &amp; Partner Sp. z o.o</pub><pmid>29681774</pmid><doi>10.1016/j.rpor.2018.01.001</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1507-1367
ispartof Reports of practical oncology and radiotherapy, 2018-03, Vol.23 (2), p.114-120
issn 1507-1367
2083-4640
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5908271
source NCBI_PubMed Central(免费)
subjects Gafchromic films
High precision measurements
Multichannel method
Original research article
Postal dosimetry audit
title High accuracy dosimetry with small pieces of Gafchromic films
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-25T22%3A13%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High%20accuracy%20dosimetry%20with%20small%20pieces%20of%20Gafchromic%20films&rft.jtitle=Reports%20of%20practical%20oncology%20and%20radiotherapy&rft.au=D%C4%85browski,%20Ryszard&rft.date=2018-03-01&rft.volume=23&rft.issue=2&rft.spage=114&rft.epage=120&rft.pages=114-120&rft.issn=1507-1367&rft.eissn=2083-4640&rft_id=info:doi/10.1016/j.rpor.2018.01.001&rft_dat=%3Cproquest_pubme%3E2029648152%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c455t-f1fd3f0ed4c7f56d2540291ce691a10f9ed6ee082373435938380467a2f7f8b93%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2029648152&rft_id=info:pmid/29681774&rfr_iscdi=true