Loading…

Accuracy of the Lee-White Clotting Time Performed in the Hospital Routine to Detect Coagulopathy in Bothrops atrox Envenomation

Snake envenomation is a major public health problem in Brazil. Systemic complications that may arise from snakebites are mainly related to coagulopathy. The Lee-White clotting time (LWCT) is a simple and inexpensive test and available even in remote health facilities. However, the diagnostic value o...

Full description

Saved in:
Bibliographic Details
Published in:The American journal of tropical medicine and hygiene 2018-01, Vol.98 (5), p.1547-1551
Main Authors: de Brito Sousa, Jose Diego, Sachett, Jacqueline Almeida Gonçalves, de Oliveira, Sâmella Silva, Mendonça-da-Silva, Iran, Marques, Hedylamar Oliveira, de Lacerda, Marcus Vinicius Guimarães, Fan, Hui Wen, Monteiro, Wuelton Marcelo
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c415t-4248947144edb3733272f01678a59bd58d56ef01ac78ac708b522c9ee51101523
cites
container_end_page 1551
container_issue 5
container_start_page 1547
container_title The American journal of tropical medicine and hygiene
container_volume 98
creator de Brito Sousa, Jose Diego
Sachett, Jacqueline Almeida Gonçalves
de Oliveira, Sâmella Silva
Mendonça-da-Silva, Iran
Marques, Hedylamar Oliveira
de Lacerda, Marcus Vinicius Guimarães
Fan, Hui Wen
Monteiro, Wuelton Marcelo
description Snake envenomation is a major public health problem in Brazil. Systemic complications that may arise from snakebites are mainly related to coagulopathy. The Lee-White clotting time (LWCT) is a simple and inexpensive test and available even in remote health facilities. However, the diagnostic value of such test needs to be evaluated to accurately diagnose coagulopathy in the clinical practice. This study aimed to assess the reliability of the LWCT performed in hospital routine to diagnose venom-induced coagulopathy. We studied 186 patients admitted at the Tropical Medicine Foundation Dr. Heitor Vieira Dourado in Manaus, Amazonas, Brazil, with envenomation diagnosis. At admission, blood samples were collected for performing LWCT and the concentration of fibrinogen. Sensitivity, specificity, positive predictive value, negative predictive value, likelihood ratios, diagnostic odds ratio, and accuracy were calculated with 95% confidence intervals. From the total, 85.5% had hypofibrinogenemia. The sensitivity of the LWCT to the diagnosis of hypofibrinogenemia was 78.0% and the specificity 40.7%. The accuracy of the test was 72.6%, and patients with a prolonged LWCT had 2.4 higher odds of developing hypofibrinogenemia. In addition, the LWCT was also compared with venom antigen levels and systemic hemorrhage. The LWCT showed moderate sensitivity to detect consumption coagulopathy and constitutes a valuable tool for the diagnosis of snake envenomation and indication of antivenom therapy.
doi_str_mv 10.4269/ajtmh.17-0992
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5953394</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2113594547</sourcerecordid><originalsourceid>FETCH-LOGICAL-c415t-4248947144edb3733272f01678a59bd58d56ef01ac78ac708b522c9ee51101523</originalsourceid><addsrcrecordid>eNpdkc1rFEEQxRtRzBo9epUGL14m9uf09kVI1miEBUUiHpve3pqdXmamxu6e4J78151NYlBPBa9-POrVI-QlZ2dK1Pat35e-PeOmYtaKR2TBlakrXiv9mCwYY6KytTQn5FnOe8b4UnD-lJwIW3OumVyQX-chTMmHA8WGlhboGqD63sYCdNVhKXHY0evYA_0CqcHUw5bG4Ra8wjzG4jv6FacZA1qQvocCodAV-t3U4ehLezjiF1jahGOmviT8SS-HGxiw9yXi8Jw8aXyX4cX9PCXfPlxer66q9eePn1bn6yoorkulhFpaZbhSsN1II6UwomG8Nkuv7Warl1tdwyz4MCvBsOVGCxEsgOaccS3kKXl35ztOmzlEgKEk37kxxd6ng0Mf3b-bIbZuhzdOWy2lVbPBm3uDhD8myMX1MQfoOj8ATtkJJrgUQsgj-vo_dI9TGuZ4bn6_1FZpZWaquqNCwpwTNA_HcOaO1brbah037ljtzL_6O8ED_adL-RsBcKD8</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2113594547</pqid></control><display><type>article</type><title>Accuracy of the Lee-White Clotting Time Performed in the Hospital Routine to Detect Coagulopathy in Bothrops atrox Envenomation</title><source>PubMed Central</source><creator>de Brito Sousa, Jose Diego ; Sachett, Jacqueline Almeida Gonçalves ; de Oliveira, Sâmella Silva ; Mendonça-da-Silva, Iran ; Marques, Hedylamar Oliveira ; de Lacerda, Marcus Vinicius Guimarães ; Fan, Hui Wen ; Monteiro, Wuelton Marcelo</creator><creatorcontrib>de Brito Sousa, Jose Diego ; Sachett, Jacqueline Almeida Gonçalves ; de Oliveira, Sâmella Silva ; Mendonça-da-Silva, Iran ; Marques, Hedylamar Oliveira ; de Lacerda, Marcus Vinicius Guimarães ; Fan, Hui Wen ; Monteiro, Wuelton Marcelo</creatorcontrib><description>Snake envenomation is a major public health problem in Brazil. Systemic complications that may arise from snakebites are mainly related to coagulopathy. The Lee-White clotting time (LWCT) is a simple and inexpensive test and available even in remote health facilities. However, the diagnostic value of such test needs to be evaluated to accurately diagnose coagulopathy in the clinical practice. This study aimed to assess the reliability of the LWCT performed in hospital routine to diagnose venom-induced coagulopathy. We studied 186 patients admitted at the Tropical Medicine Foundation Dr. Heitor Vieira Dourado in Manaus, Amazonas, Brazil, with envenomation diagnosis. At admission, blood samples were collected for performing LWCT and the concentration of fibrinogen. Sensitivity, specificity, positive predictive value, negative predictive value, likelihood ratios, diagnostic odds ratio, and accuracy were calculated with 95% confidence intervals. From the total, 85.5% had hypofibrinogenemia. The sensitivity of the LWCT to the diagnosis of hypofibrinogenemia was 78.0% and the specificity 40.7%. The accuracy of the test was 72.6%, and patients with a prolonged LWCT had 2.4 higher odds of developing hypofibrinogenemia. In addition, the LWCT was also compared with venom antigen levels and systemic hemorrhage. The LWCT showed moderate sensitivity to detect consumption coagulopathy and constitutes a valuable tool for the diagnosis of snake envenomation and indication of antivenom therapy.</description><identifier>ISSN: 0002-9637</identifier><identifier>EISSN: 1476-1645</identifier><identifier>DOI: 10.4269/ajtmh.17-0992</identifier><identifier>PMID: 29611503</identifier><language>eng</language><publisher>United States: Institute of Tropical Medicine</publisher><subject>Accuracy ; Snakes ; Venom</subject><ispartof>The American journal of tropical medicine and hygiene, 2018-01, Vol.98 (5), p.1547-1551</ispartof><rights>Copyright Institute of Tropical Medicine 2018</rights><rights>The American Society of Tropical Medicine and Hygiene 2018</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c415t-4248947144edb3733272f01678a59bd58d56ef01ac78ac708b522c9ee51101523</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5953394/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5953394/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,723,776,780,881,27901,27902,53766,53768</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29611503$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>de Brito Sousa, Jose Diego</creatorcontrib><creatorcontrib>Sachett, Jacqueline Almeida Gonçalves</creatorcontrib><creatorcontrib>de Oliveira, Sâmella Silva</creatorcontrib><creatorcontrib>Mendonça-da-Silva, Iran</creatorcontrib><creatorcontrib>Marques, Hedylamar Oliveira</creatorcontrib><creatorcontrib>de Lacerda, Marcus Vinicius Guimarães</creatorcontrib><creatorcontrib>Fan, Hui Wen</creatorcontrib><creatorcontrib>Monteiro, Wuelton Marcelo</creatorcontrib><title>Accuracy of the Lee-White Clotting Time Performed in the Hospital Routine to Detect Coagulopathy in Bothrops atrox Envenomation</title><title>The American journal of tropical medicine and hygiene</title><addtitle>Am J Trop Med Hyg</addtitle><description>Snake envenomation is a major public health problem in Brazil. Systemic complications that may arise from snakebites are mainly related to coagulopathy. The Lee-White clotting time (LWCT) is a simple and inexpensive test and available even in remote health facilities. However, the diagnostic value of such test needs to be evaluated to accurately diagnose coagulopathy in the clinical practice. This study aimed to assess the reliability of the LWCT performed in hospital routine to diagnose venom-induced coagulopathy. We studied 186 patients admitted at the Tropical Medicine Foundation Dr. Heitor Vieira Dourado in Manaus, Amazonas, Brazil, with envenomation diagnosis. At admission, blood samples were collected for performing LWCT and the concentration of fibrinogen. Sensitivity, specificity, positive predictive value, negative predictive value, likelihood ratios, diagnostic odds ratio, and accuracy were calculated with 95% confidence intervals. From the total, 85.5% had hypofibrinogenemia. The sensitivity of the LWCT to the diagnosis of hypofibrinogenemia was 78.0% and the specificity 40.7%. The accuracy of the test was 72.6%, and patients with a prolonged LWCT had 2.4 higher odds of developing hypofibrinogenemia. In addition, the LWCT was also compared with venom antigen levels and systemic hemorrhage. The LWCT showed moderate sensitivity to detect consumption coagulopathy and constitutes a valuable tool for the diagnosis of snake envenomation and indication of antivenom therapy.</description><subject>Accuracy</subject><subject>Snakes</subject><subject>Venom</subject><issn>0002-9637</issn><issn>1476-1645</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNpdkc1rFEEQxRtRzBo9epUGL14m9uf09kVI1miEBUUiHpve3pqdXmamxu6e4J78151NYlBPBa9-POrVI-QlZ2dK1Pat35e-PeOmYtaKR2TBlakrXiv9mCwYY6KytTQn5FnOe8b4UnD-lJwIW3OumVyQX-chTMmHA8WGlhboGqD63sYCdNVhKXHY0evYA_0CqcHUw5bG4Ra8wjzG4jv6FacZA1qQvocCodAV-t3U4ehLezjiF1jahGOmviT8SS-HGxiw9yXi8Jw8aXyX4cX9PCXfPlxer66q9eePn1bn6yoorkulhFpaZbhSsN1II6UwomG8Nkuv7Warl1tdwyz4MCvBsOVGCxEsgOaccS3kKXl35ztOmzlEgKEk37kxxd6ng0Mf3b-bIbZuhzdOWy2lVbPBm3uDhD8myMX1MQfoOj8ATtkJJrgUQsgj-vo_dI9TGuZ4bn6_1FZpZWaquqNCwpwTNA_HcOaO1brbah037ljtzL_6O8ED_adL-RsBcKD8</recordid><startdate>20180101</startdate><enddate>20180101</enddate><creator>de Brito Sousa, Jose Diego</creator><creator>Sachett, Jacqueline Almeida Gonçalves</creator><creator>de Oliveira, Sâmella Silva</creator><creator>Mendonça-da-Silva, Iran</creator><creator>Marques, Hedylamar Oliveira</creator><creator>de Lacerda, Marcus Vinicius Guimarães</creator><creator>Fan, Hui Wen</creator><creator>Monteiro, Wuelton Marcelo</creator><general>Institute of Tropical Medicine</general><general>The American Society of Tropical Medicine and Hygiene</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20180101</creationdate><title>Accuracy of the Lee-White Clotting Time Performed in the Hospital Routine to Detect Coagulopathy in Bothrops atrox Envenomation</title><author>de Brito Sousa, Jose Diego ; Sachett, Jacqueline Almeida Gonçalves ; de Oliveira, Sâmella Silva ; Mendonça-da-Silva, Iran ; Marques, Hedylamar Oliveira ; de Lacerda, Marcus Vinicius Guimarães ; Fan, Hui Wen ; Monteiro, Wuelton Marcelo</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c415t-4248947144edb3733272f01678a59bd58d56ef01ac78ac708b522c9ee51101523</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Accuracy</topic><topic>Snakes</topic><topic>Venom</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>de Brito Sousa, Jose Diego</creatorcontrib><creatorcontrib>Sachett, Jacqueline Almeida Gonçalves</creatorcontrib><creatorcontrib>de Oliveira, Sâmella Silva</creatorcontrib><creatorcontrib>Mendonça-da-Silva, Iran</creatorcontrib><creatorcontrib>Marques, Hedylamar Oliveira</creatorcontrib><creatorcontrib>de Lacerda, Marcus Vinicius Guimarães</creatorcontrib><creatorcontrib>Fan, Hui Wen</creatorcontrib><creatorcontrib>Monteiro, Wuelton Marcelo</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>The American journal of tropical medicine and hygiene</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>de Brito Sousa, Jose Diego</au><au>Sachett, Jacqueline Almeida Gonçalves</au><au>de Oliveira, Sâmella Silva</au><au>Mendonça-da-Silva, Iran</au><au>Marques, Hedylamar Oliveira</au><au>de Lacerda, Marcus Vinicius Guimarães</au><au>Fan, Hui Wen</au><au>Monteiro, Wuelton Marcelo</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Accuracy of the Lee-White Clotting Time Performed in the Hospital Routine to Detect Coagulopathy in Bothrops atrox Envenomation</atitle><jtitle>The American journal of tropical medicine and hygiene</jtitle><addtitle>Am J Trop Med Hyg</addtitle><date>2018-01-01</date><risdate>2018</risdate><volume>98</volume><issue>5</issue><spage>1547</spage><epage>1551</epage><pages>1547-1551</pages><issn>0002-9637</issn><eissn>1476-1645</eissn><abstract>Snake envenomation is a major public health problem in Brazil. Systemic complications that may arise from snakebites are mainly related to coagulopathy. The Lee-White clotting time (LWCT) is a simple and inexpensive test and available even in remote health facilities. However, the diagnostic value of such test needs to be evaluated to accurately diagnose coagulopathy in the clinical practice. This study aimed to assess the reliability of the LWCT performed in hospital routine to diagnose venom-induced coagulopathy. We studied 186 patients admitted at the Tropical Medicine Foundation Dr. Heitor Vieira Dourado in Manaus, Amazonas, Brazil, with envenomation diagnosis. At admission, blood samples were collected for performing LWCT and the concentration of fibrinogen. Sensitivity, specificity, positive predictive value, negative predictive value, likelihood ratios, diagnostic odds ratio, and accuracy were calculated with 95% confidence intervals. From the total, 85.5% had hypofibrinogenemia. The sensitivity of the LWCT to the diagnosis of hypofibrinogenemia was 78.0% and the specificity 40.7%. The accuracy of the test was 72.6%, and patients with a prolonged LWCT had 2.4 higher odds of developing hypofibrinogenemia. In addition, the LWCT was also compared with venom antigen levels and systemic hemorrhage. The LWCT showed moderate sensitivity to detect consumption coagulopathy and constitutes a valuable tool for the diagnosis of snake envenomation and indication of antivenom therapy.</abstract><cop>United States</cop><pub>Institute of Tropical Medicine</pub><pmid>29611503</pmid><doi>10.4269/ajtmh.17-0992</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0002-9637
ispartof The American journal of tropical medicine and hygiene, 2018-01, Vol.98 (5), p.1547-1551
issn 0002-9637
1476-1645
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_5953394
source PubMed Central
subjects Accuracy
Snakes
Venom
title Accuracy of the Lee-White Clotting Time Performed in the Hospital Routine to Detect Coagulopathy in Bothrops atrox Envenomation
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T11%3A12%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Accuracy%20of%20the%20Lee-White%20Clotting%20Time%20Performed%20in%20the%20Hospital%20Routine%20to%20Detect%20Coagulopathy%20in%20Bothrops%20atrox%20Envenomation&rft.jtitle=The%20American%20journal%20of%20tropical%20medicine%20and%20hygiene&rft.au=de%20Brito%20Sousa,%20Jose%20Diego&rft.date=2018-01-01&rft.volume=98&rft.issue=5&rft.spage=1547&rft.epage=1551&rft.pages=1547-1551&rft.issn=0002-9637&rft.eissn=1476-1645&rft_id=info:doi/10.4269/ajtmh.17-0992&rft_dat=%3Cproquest_pubme%3E2113594547%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c415t-4248947144edb3733272f01678a59bd58d56ef01ac78ac708b522c9ee51101523%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2113594547&rft_id=info:pmid/29611503&rfr_iscdi=true