Loading…

Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves

Three dimensional ultrasound (3-D US) imaging methods based on 2-D array probes are increasingly investigated. However, the experimental test of new 3-D US approaches is contrasted by the need of controlling very large numbers of probe elements. Although this problem may be overcome by the use of 2-...

Full description

Saved in:
Bibliographic Details
Published in:Scientific reports 2018-06, Vol.8 (1), p.9108-12, Article 9108
Main Authors: Roux, Emmanuel, Varray, François, Petrusca, Lorena, Cachard, Christian, Tortoli, Piero, Liebgott, Hervé
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c508t-d56fa7f7821c610231e1a6c5af9d0d0bd131276e2f4314eec485fedb743041d03
cites cdi_FETCH-LOGICAL-c508t-d56fa7f7821c610231e1a6c5af9d0d0bd131276e2f4314eec485fedb743041d03
container_end_page 12
container_issue 1
container_start_page 9108
container_title Scientific reports
container_volume 8
creator Roux, Emmanuel
Varray, François
Petrusca, Lorena
Cachard, Christian
Tortoli, Piero
Liebgott, Hervé
description Three dimensional ultrasound (3-D US) imaging methods based on 2-D array probes are increasingly investigated. However, the experimental test of new 3-D US approaches is contrasted by the need of controlling very large numbers of probe elements. Although this problem may be overcome by the use of 2-D sparse arrays, just a few experimental results have so far corroborated the validity of this approach. In this paper, we experimentally compare the performance of a fully wired 1024-element (32 × 32) array, assumed as reference, to that of a 256-element random and of an “optimized” 2-D sparse array, in both focused and compounded diverging wave (DW) transmission modes. The experimental results in 3-D focused mode show that the resolution and contrast produced by the optimized sparse array are close to those of the full array while using 25% of elements. Furthermore, the experimental results in 3-D DW mode and 3-D focused mode are also compared for the first time and they show that both the contrast and the resolution performance are higher when using the 3-D DW at volume rates up to 90/second which represent a 36x speed up factor compared to the focused mode.
doi_str_mv 10.1038/s41598-018-27490-2
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6002520</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2056396251</sourcerecordid><originalsourceid>FETCH-LOGICAL-c508t-d56fa7f7821c610231e1a6c5af9d0d0bd131276e2f4314eec485fedb743041d03</originalsourceid><addsrcrecordid>eNp9UU1P3DAQtapWgCh_gEMViUs5pNjjj8SXSqsFukgrcWgRFyTLG092g7LJ1k625d_X2VC-Dvhiy_Pem3nzCDlm9BujPD8Lgkmdp5TlKWRC0xQ-kAOgQqbAAT6-eO-ToxDuaTwStGB6j-yD1lSwHA7I3cXfDfpqjU1n64Sn58lN3Xkb2r5xydXaLqtmmfypulUCsfZzY33AZOK9fQhJH4biZVv0AV1iI-G82qLfUW7tFsNn8qm0dcCjx_uQ3Fxe_JrO0vn1j6vpZJ4WkuZd6qQqbVZmObBCMQqcIbOqkLbUjjq6cIwzyBRCKTgTiIXIZYlukQkeXTjKD8n3UXfTL9boimjG29psoi_rH0xrK_O60lQrs2y3RlEKEgaB01Fg9YY2m8zN8BfXzLVWfMsi9utjM9_-7jF0Zl2FAuvaNtj2wQCVimsFcoCevIHet71v4ioGlIz5KaEjCkZU4dsQPJZPEzBqhqzNmPUwhNllbSCSvry0_ET5n2wE8BEQYqlZon_u_Y7sPwIRstQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2055598649</pqid></control><display><type>article</type><title>Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves</title><source>NCBI_PubMed Central(免费)</source><source>Publicly Available Content Database</source><source>Free Full-Text Journals in Chemistry</source><source>Springer Nature - nature.com Journals - Fully Open Access</source><creator>Roux, Emmanuel ; Varray, François ; Petrusca, Lorena ; Cachard, Christian ; Tortoli, Piero ; Liebgott, Hervé</creator><creatorcontrib>Roux, Emmanuel ; Varray, François ; Petrusca, Lorena ; Cachard, Christian ; Tortoli, Piero ; Liebgott, Hervé</creatorcontrib><description>Three dimensional ultrasound (3-D US) imaging methods based on 2-D array probes are increasingly investigated. However, the experimental test of new 3-D US approaches is contrasted by the need of controlling very large numbers of probe elements. Although this problem may be overcome by the use of 2-D sparse arrays, just a few experimental results have so far corroborated the validity of this approach. In this paper, we experimentally compare the performance of a fully wired 1024-element (32 × 32) array, assumed as reference, to that of a 256-element random and of an “optimized” 2-D sparse array, in both focused and compounded diverging wave (DW) transmission modes. The experimental results in 3-D focused mode show that the resolution and contrast produced by the optimized sparse array are close to those of the full array while using 25% of elements. Furthermore, the experimental results in 3-D DW mode and 3-D focused mode are also compared for the first time and they show that both the contrast and the resolution performance are higher when using the 3-D DW at volume rates up to 90/second which represent a 36x speed up factor compared to the focused mode.</description><identifier>ISSN: 2045-2322</identifier><identifier>EISSN: 2045-2322</identifier><identifier>DOI: 10.1038/s41598-018-27490-2</identifier><identifier>PMID: 29904182</identifier><language>eng</language><publisher>London: Nature Publishing Group UK</publisher><subject>639/166/987 ; 639/766/25/3927 ; Acoustics ; Bioengineering ; Engineering Sciences ; Humanities and Social Sciences ; Imaging ; Life Sciences ; multidisciplinary ; Science ; Science (multidisciplinary) ; Ultrasonic imaging ; Ultrasound</subject><ispartof>Scientific reports, 2018-06, Vol.8 (1), p.9108-12, Article 9108</ispartof><rights>The Author(s) 2018</rights><rights>2018. This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>Distributed under a Creative Commons Attribution 4.0 International License</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c508t-d56fa7f7821c610231e1a6c5af9d0d0bd131276e2f4314eec485fedb743041d03</citedby><cites>FETCH-LOGICAL-c508t-d56fa7f7821c610231e1a6c5af9d0d0bd131276e2f4314eec485fedb743041d03</cites><orcidid>0000-0002-0666-5607 ; 0000-0001-8168-5643 ; 0000-0001-6228-5900 ; 0000-0002-7602-1452</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2055598649/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2055598649?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,25753,27924,27925,37012,37013,44590,53791,53793,75126</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/29904182$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink><backlink>$$Uhttps://hal.science/hal-01839963$$DView record in HAL$$Hfree_for_read</backlink></links><search><creatorcontrib>Roux, Emmanuel</creatorcontrib><creatorcontrib>Varray, François</creatorcontrib><creatorcontrib>Petrusca, Lorena</creatorcontrib><creatorcontrib>Cachard, Christian</creatorcontrib><creatorcontrib>Tortoli, Piero</creatorcontrib><creatorcontrib>Liebgott, Hervé</creatorcontrib><title>Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves</title><title>Scientific reports</title><addtitle>Sci Rep</addtitle><addtitle>Sci Rep</addtitle><description>Three dimensional ultrasound (3-D US) imaging methods based on 2-D array probes are increasingly investigated. However, the experimental test of new 3-D US approaches is contrasted by the need of controlling very large numbers of probe elements. Although this problem may be overcome by the use of 2-D sparse arrays, just a few experimental results have so far corroborated the validity of this approach. In this paper, we experimentally compare the performance of a fully wired 1024-element (32 × 32) array, assumed as reference, to that of a 256-element random and of an “optimized” 2-D sparse array, in both focused and compounded diverging wave (DW) transmission modes. The experimental results in 3-D focused mode show that the resolution and contrast produced by the optimized sparse array are close to those of the full array while using 25% of elements. Furthermore, the experimental results in 3-D DW mode and 3-D focused mode are also compared for the first time and they show that both the contrast and the resolution performance are higher when using the 3-D DW at volume rates up to 90/second which represent a 36x speed up factor compared to the focused mode.</description><subject>639/166/987</subject><subject>639/766/25/3927</subject><subject>Acoustics</subject><subject>Bioengineering</subject><subject>Engineering Sciences</subject><subject>Humanities and Social Sciences</subject><subject>Imaging</subject><subject>Life Sciences</subject><subject>multidisciplinary</subject><subject>Science</subject><subject>Science (multidisciplinary)</subject><subject>Ultrasonic imaging</subject><subject>Ultrasound</subject><issn>2045-2322</issn><issn>2045-2322</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNp9UU1P3DAQtapWgCh_gEMViUs5pNjjj8SXSqsFukgrcWgRFyTLG092g7LJ1k625d_X2VC-Dvhiy_Pem3nzCDlm9BujPD8Lgkmdp5TlKWRC0xQ-kAOgQqbAAT6-eO-ToxDuaTwStGB6j-yD1lSwHA7I3cXfDfpqjU1n64Sn58lN3Xkb2r5xydXaLqtmmfypulUCsfZzY33AZOK9fQhJH4biZVv0AV1iI-G82qLfUW7tFsNn8qm0dcCjx_uQ3Fxe_JrO0vn1j6vpZJ4WkuZd6qQqbVZmObBCMQqcIbOqkLbUjjq6cIwzyBRCKTgTiIXIZYlukQkeXTjKD8n3UXfTL9boimjG29psoi_rH0xrK_O60lQrs2y3RlEKEgaB01Fg9YY2m8zN8BfXzLVWfMsi9utjM9_-7jF0Zl2FAuvaNtj2wQCVimsFcoCevIHet71v4ioGlIz5KaEjCkZU4dsQPJZPEzBqhqzNmPUwhNllbSCSvry0_ET5n2wE8BEQYqlZon_u_Y7sPwIRstQ</recordid><startdate>20180614</startdate><enddate>20180614</enddate><creator>Roux, Emmanuel</creator><creator>Varray, François</creator><creator>Petrusca, Lorena</creator><creator>Cachard, Christian</creator><creator>Tortoli, Piero</creator><creator>Liebgott, Hervé</creator><general>Nature Publishing Group UK</general><general>Nature Publishing Group</general><scope>C6C</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88A</scope><scope>88E</scope><scope>88I</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M2P</scope><scope>M7P</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>Q9U</scope><scope>7X8</scope><scope>1XC</scope><scope>VOOES</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-0666-5607</orcidid><orcidid>https://orcid.org/0000-0001-8168-5643</orcidid><orcidid>https://orcid.org/0000-0001-6228-5900</orcidid><orcidid>https://orcid.org/0000-0002-7602-1452</orcidid></search><sort><creationdate>20180614</creationdate><title>Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves</title><author>Roux, Emmanuel ; Varray, François ; Petrusca, Lorena ; Cachard, Christian ; Tortoli, Piero ; Liebgott, Hervé</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c508t-d56fa7f7821c610231e1a6c5af9d0d0bd131276e2f4314eec485fedb743041d03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>639/166/987</topic><topic>639/766/25/3927</topic><topic>Acoustics</topic><topic>Bioengineering</topic><topic>Engineering Sciences</topic><topic>Humanities and Social Sciences</topic><topic>Imaging</topic><topic>Life Sciences</topic><topic>multidisciplinary</topic><topic>Science</topic><topic>Science (multidisciplinary)</topic><topic>Ultrasonic imaging</topic><topic>Ultrasound</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Roux, Emmanuel</creatorcontrib><creatorcontrib>Varray, François</creatorcontrib><creatorcontrib>Petrusca, Lorena</creatorcontrib><creatorcontrib>Cachard, Christian</creatorcontrib><creatorcontrib>Tortoli, Piero</creatorcontrib><creatorcontrib>Liebgott, Hervé</creatorcontrib><collection>Springer_OA刊</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>ProQuest_Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Biology Database (Alumni Edition)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Science Database (Alumni Edition)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection (Proquest) (PQ_SDU_P3)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>PML(ProQuest Medical Library)</collection><collection>ProQuest Science Journals</collection><collection>ProQuest Biological Science Journals</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><collection>Hyper Article en Ligne (HAL)</collection><collection>Hyper Article en Ligne (HAL) (Open Access)</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Scientific reports</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Roux, Emmanuel</au><au>Varray, François</au><au>Petrusca, Lorena</au><au>Cachard, Christian</au><au>Tortoli, Piero</au><au>Liebgott, Hervé</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves</atitle><jtitle>Scientific reports</jtitle><stitle>Sci Rep</stitle><addtitle>Sci Rep</addtitle><date>2018-06-14</date><risdate>2018</risdate><volume>8</volume><issue>1</issue><spage>9108</spage><epage>12</epage><pages>9108-12</pages><artnum>9108</artnum><issn>2045-2322</issn><eissn>2045-2322</eissn><abstract>Three dimensional ultrasound (3-D US) imaging methods based on 2-D array probes are increasingly investigated. However, the experimental test of new 3-D US approaches is contrasted by the need of controlling very large numbers of probe elements. Although this problem may be overcome by the use of 2-D sparse arrays, just a few experimental results have so far corroborated the validity of this approach. In this paper, we experimentally compare the performance of a fully wired 1024-element (32 × 32) array, assumed as reference, to that of a 256-element random and of an “optimized” 2-D sparse array, in both focused and compounded diverging wave (DW) transmission modes. The experimental results in 3-D focused mode show that the resolution and contrast produced by the optimized sparse array are close to those of the full array while using 25% of elements. Furthermore, the experimental results in 3-D DW mode and 3-D focused mode are also compared for the first time and they show that both the contrast and the resolution performance are higher when using the 3-D DW at volume rates up to 90/second which represent a 36x speed up factor compared to the focused mode.</abstract><cop>London</cop><pub>Nature Publishing Group UK</pub><pmid>29904182</pmid><doi>10.1038/s41598-018-27490-2</doi><tpages>12</tpages><orcidid>https://orcid.org/0000-0002-0666-5607</orcidid><orcidid>https://orcid.org/0000-0001-8168-5643</orcidid><orcidid>https://orcid.org/0000-0001-6228-5900</orcidid><orcidid>https://orcid.org/0000-0002-7602-1452</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2045-2322
ispartof Scientific reports, 2018-06, Vol.8 (1), p.9108-12, Article 9108
issn 2045-2322
2045-2322
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6002520
source NCBI_PubMed Central(免费); Publicly Available Content Database; Free Full-Text Journals in Chemistry; Springer Nature - nature.com Journals - Fully Open Access
subjects 639/166/987
639/766/25/3927
Acoustics
Bioengineering
Engineering Sciences
Humanities and Social Sciences
Imaging
Life Sciences
multidisciplinary
Science
Science (multidisciplinary)
Ultrasonic imaging
Ultrasound
title Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T04%3A53%3A18IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Experimental%203-D%20Ultrasound%20Imaging%20with%202-D%20Sparse%20Arrays%20using%20Focused%20and%20Diverging%20Waves&rft.jtitle=Scientific%20reports&rft.au=Roux,%20Emmanuel&rft.date=2018-06-14&rft.volume=8&rft.issue=1&rft.spage=9108&rft.epage=12&rft.pages=9108-12&rft.artnum=9108&rft.issn=2045-2322&rft.eissn=2045-2322&rft_id=info:doi/10.1038/s41598-018-27490-2&rft_dat=%3Cproquest_pubme%3E2056396251%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c508t-d56fa7f7821c610231e1a6c5af9d0d0bd131276e2f4314eec485fedb743041d03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2055598649&rft_id=info:pmid/29904182&rfr_iscdi=true