Loading…
Computed Tomographic Characterization of Traumastem-A New Oxidized Cellulose Hemostatic Agent
Oxidized regenerated cellulose (ORC) is a commonly used surgical hemostatic agent. When retained at the surgical site, it is frequently misdiagnosed on postoperative computed tomography (CT) images as an abscess or a recurrent tumor. Oxidized nonregenerated cellulose (ONC) is a new, more effective v...
Saved in:
Published in: | Tomography (Ann Arbor) 2016-09, Vol.2 (3), p.175-178 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c329t-55cdced574bdfc06e138d6567bbb2d930157b4a9b8030d9fbe725f52cd49cf983 |
---|---|
cites | |
container_end_page | 178 |
container_issue | 3 |
container_start_page | 175 |
container_title | Tomography (Ann Arbor) |
container_volume | 2 |
creator | Lewis, Paul B Wilson, Scott T Kentala, Dustin R Barry, John Lewis, Kevin M |
description | Oxidized regenerated cellulose (ORC) is a commonly used surgical hemostatic agent. When retained at the surgical site, it is frequently misdiagnosed on postoperative computed tomography (CT) images as an abscess or a recurrent tumor. Oxidized nonregenerated cellulose (ONC) is a new, more effective version of ORC. It is more effective because of its unorganized fiber structure and greater material density, which may also alter its appearance on CT images relative to ORC. This image report compares the CT characteristics of ONC and ORC. A rabbit's bilateral femoral arteries were punctured to model peripheral vascular surgery. ORC was used to treat 1 of the femoral artery punctures and ONC to treat the contralateral puncture. Noncontrast CT imaging was performed immediately following surgery (day 0) and on postoperative day 14. On day 0, both ORC and ONC were isoattenuating relative to muscle and hyperattenuating to fat, although ONC appears more homogenous. On day 14, neither ORC nor ONC was clearly identifiable. Thus, postoperative retention of ONC can obscure immediate postoperative CT interpretation and, similar to ORC, lead to an erroneous diagnosis of an abscess. By day 14, ONC retention may not obscure CT interpretation. In noncontrast CT imaging, ONC appears more homogeneous than ORC, but is otherwise indistinguishable. The greater homogeneity of ONC may be caused by the unorganized fiber structure or greater material density. Intraoperative use of ONC should be clinically investigated before radiographically diagnosing a postoperative abscess or recurrent tumor. |
doi_str_mv | 10.18383/j.tom.2016.00238 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6024394</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2076241883</sourcerecordid><originalsourceid>FETCH-LOGICAL-c329t-55cdced574bdfc06e138d6567bbb2d930157b4a9b8030d9fbe725f52cd49cf983</originalsourceid><addsrcrecordid>eNpVkUtLAzEUhYMoKtUf4EZm6WZqHvPKRiiDWqHYTQU3EjJJpk2ZTGqS8dFfb6wPFC7cCznn3Fw-AM4QHKOKVORyPQ7WjDFExRhCTKo9cIxJSVNE6OP-n_kInHq_hlEDcazyEBwRCDNMC3wMnmprNkNQMllYY5eOb1ZaJPWKOy6CcnrLg7Z9Yttk4fhguA_KpJPkXr0m8zct9TY6a9V1Q2e9SqbKWB-iRSSTperDCThoeefV6XcfgYeb60U9TWfz27t6MksFwTSkeS6kUDIvs0a2AhYKkUoWeVE2TYMlJRDlZZNx2lSQQEnbRpU4b3MsZEZFSysyAldfuZuhMSpm9cHxjm2cNty9M8s1-__S6xVb2hdWQJwRmsWAi-8AZ58H5QMz2ot4F--VHTzDsCxwhqqKRCn6kgpnvXeq_V2DINuRYWsWybBPMmxHJnrO__7v1_HDgXwApLyNSg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2076241883</pqid></control><display><type>article</type><title>Computed Tomographic Characterization of Traumastem-A New Oxidized Cellulose Hemostatic Agent</title><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><creator>Lewis, Paul B ; Wilson, Scott T ; Kentala, Dustin R ; Barry, John ; Lewis, Kevin M</creator><creatorcontrib>Lewis, Paul B ; Wilson, Scott T ; Kentala, Dustin R ; Barry, John ; Lewis, Kevin M</creatorcontrib><description>Oxidized regenerated cellulose (ORC) is a commonly used surgical hemostatic agent. When retained at the surgical site, it is frequently misdiagnosed on postoperative computed tomography (CT) images as an abscess or a recurrent tumor. Oxidized nonregenerated cellulose (ONC) is a new, more effective version of ORC. It is more effective because of its unorganized fiber structure and greater material density, which may also alter its appearance on CT images relative to ORC. This image report compares the CT characteristics of ONC and ORC. A rabbit's bilateral femoral arteries were punctured to model peripheral vascular surgery. ORC was used to treat 1 of the femoral artery punctures and ONC to treat the contralateral puncture. Noncontrast CT imaging was performed immediately following surgery (day 0) and on postoperative day 14. On day 0, both ORC and ONC were isoattenuating relative to muscle and hyperattenuating to fat, although ONC appears more homogenous. On day 14, neither ORC nor ONC was clearly identifiable. Thus, postoperative retention of ONC can obscure immediate postoperative CT interpretation and, similar to ORC, lead to an erroneous diagnosis of an abscess. By day 14, ONC retention may not obscure CT interpretation. In noncontrast CT imaging, ONC appears more homogeneous than ORC, but is otherwise indistinguishable. The greater homogeneity of ONC may be caused by the unorganized fiber structure or greater material density. Intraoperative use of ONC should be clinically investigated before radiographically diagnosing a postoperative abscess or recurrent tumor.</description><identifier>ISSN: 2379-139X</identifier><identifier>ISSN: 2379-1381</identifier><identifier>EISSN: 2379-139X</identifier><identifier>DOI: 10.18383/j.tom.2016.00238</identifier><identifier>PMID: 30042962</identifier><language>eng</language><publisher>United States: Grapho Publications, LLC</publisher><subject>Image Report</subject><ispartof>Tomography (Ann Arbor), 2016-09, Vol.2 (3), p.175-178</ispartof><rights>2016 The Authors. Published by Grapho Publications, LLC 2016 Grapho Publications, LLC</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c329t-55cdced574bdfc06e138d6567bbb2d930157b4a9b8030d9fbe725f52cd49cf983</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6024394/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6024394/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30042962$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lewis, Paul B</creatorcontrib><creatorcontrib>Wilson, Scott T</creatorcontrib><creatorcontrib>Kentala, Dustin R</creatorcontrib><creatorcontrib>Barry, John</creatorcontrib><creatorcontrib>Lewis, Kevin M</creatorcontrib><title>Computed Tomographic Characterization of Traumastem-A New Oxidized Cellulose Hemostatic Agent</title><title>Tomography (Ann Arbor)</title><addtitle>Tomography</addtitle><description>Oxidized regenerated cellulose (ORC) is a commonly used surgical hemostatic agent. When retained at the surgical site, it is frequently misdiagnosed on postoperative computed tomography (CT) images as an abscess or a recurrent tumor. Oxidized nonregenerated cellulose (ONC) is a new, more effective version of ORC. It is more effective because of its unorganized fiber structure and greater material density, which may also alter its appearance on CT images relative to ORC. This image report compares the CT characteristics of ONC and ORC. A rabbit's bilateral femoral arteries were punctured to model peripheral vascular surgery. ORC was used to treat 1 of the femoral artery punctures and ONC to treat the contralateral puncture. Noncontrast CT imaging was performed immediately following surgery (day 0) and on postoperative day 14. On day 0, both ORC and ONC were isoattenuating relative to muscle and hyperattenuating to fat, although ONC appears more homogenous. On day 14, neither ORC nor ONC was clearly identifiable. Thus, postoperative retention of ONC can obscure immediate postoperative CT interpretation and, similar to ORC, lead to an erroneous diagnosis of an abscess. By day 14, ONC retention may not obscure CT interpretation. In noncontrast CT imaging, ONC appears more homogeneous than ORC, but is otherwise indistinguishable. The greater homogeneity of ONC may be caused by the unorganized fiber structure or greater material density. Intraoperative use of ONC should be clinically investigated before radiographically diagnosing a postoperative abscess or recurrent tumor.</description><subject>Image Report</subject><issn>2379-139X</issn><issn>2379-1381</issn><issn>2379-139X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2016</creationdate><recordtype>article</recordtype><recordid>eNpVkUtLAzEUhYMoKtUf4EZm6WZqHvPKRiiDWqHYTQU3EjJJpk2ZTGqS8dFfb6wPFC7cCznn3Fw-AM4QHKOKVORyPQ7WjDFExRhCTKo9cIxJSVNE6OP-n_kInHq_hlEDcazyEBwRCDNMC3wMnmprNkNQMllYY5eOb1ZaJPWKOy6CcnrLg7Z9Yttk4fhguA_KpJPkXr0m8zct9TY6a9V1Q2e9SqbKWB-iRSSTperDCThoeefV6XcfgYeb60U9TWfz27t6MksFwTSkeS6kUDIvs0a2AhYKkUoWeVE2TYMlJRDlZZNx2lSQQEnbRpU4b3MsZEZFSysyAldfuZuhMSpm9cHxjm2cNty9M8s1-__S6xVb2hdWQJwRmsWAi-8AZ58H5QMz2ot4F--VHTzDsCxwhqqKRCn6kgpnvXeq_V2DINuRYWsWybBPMmxHJnrO__7v1_HDgXwApLyNSg</recordid><startdate>201609</startdate><enddate>201609</enddate><creator>Lewis, Paul B</creator><creator>Wilson, Scott T</creator><creator>Kentala, Dustin R</creator><creator>Barry, John</creator><creator>Lewis, Kevin M</creator><general>Grapho Publications, LLC</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>201609</creationdate><title>Computed Tomographic Characterization of Traumastem-A New Oxidized Cellulose Hemostatic Agent</title><author>Lewis, Paul B ; Wilson, Scott T ; Kentala, Dustin R ; Barry, John ; Lewis, Kevin M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c329t-55cdced574bdfc06e138d6567bbb2d930157b4a9b8030d9fbe725f52cd49cf983</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2016</creationdate><topic>Image Report</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lewis, Paul B</creatorcontrib><creatorcontrib>Wilson, Scott T</creatorcontrib><creatorcontrib>Kentala, Dustin R</creatorcontrib><creatorcontrib>Barry, John</creatorcontrib><creatorcontrib>Lewis, Kevin M</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Tomography (Ann Arbor)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lewis, Paul B</au><au>Wilson, Scott T</au><au>Kentala, Dustin R</au><au>Barry, John</au><au>Lewis, Kevin M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Computed Tomographic Characterization of Traumastem-A New Oxidized Cellulose Hemostatic Agent</atitle><jtitle>Tomography (Ann Arbor)</jtitle><addtitle>Tomography</addtitle><date>2016-09</date><risdate>2016</risdate><volume>2</volume><issue>3</issue><spage>175</spage><epage>178</epage><pages>175-178</pages><issn>2379-139X</issn><issn>2379-1381</issn><eissn>2379-139X</eissn><abstract>Oxidized regenerated cellulose (ORC) is a commonly used surgical hemostatic agent. When retained at the surgical site, it is frequently misdiagnosed on postoperative computed tomography (CT) images as an abscess or a recurrent tumor. Oxidized nonregenerated cellulose (ONC) is a new, more effective version of ORC. It is more effective because of its unorganized fiber structure and greater material density, which may also alter its appearance on CT images relative to ORC. This image report compares the CT characteristics of ONC and ORC. A rabbit's bilateral femoral arteries were punctured to model peripheral vascular surgery. ORC was used to treat 1 of the femoral artery punctures and ONC to treat the contralateral puncture. Noncontrast CT imaging was performed immediately following surgery (day 0) and on postoperative day 14. On day 0, both ORC and ONC were isoattenuating relative to muscle and hyperattenuating to fat, although ONC appears more homogenous. On day 14, neither ORC nor ONC was clearly identifiable. Thus, postoperative retention of ONC can obscure immediate postoperative CT interpretation and, similar to ORC, lead to an erroneous diagnosis of an abscess. By day 14, ONC retention may not obscure CT interpretation. In noncontrast CT imaging, ONC appears more homogeneous than ORC, but is otherwise indistinguishable. The greater homogeneity of ONC may be caused by the unorganized fiber structure or greater material density. Intraoperative use of ONC should be clinically investigated before radiographically diagnosing a postoperative abscess or recurrent tumor.</abstract><cop>United States</cop><pub>Grapho Publications, LLC</pub><pmid>30042962</pmid><doi>10.18383/j.tom.2016.00238</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2379-139X |
ispartof | Tomography (Ann Arbor), 2016-09, Vol.2 (3), p.175-178 |
issn | 2379-139X 2379-1381 2379-139X |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6024394 |
source | EZB-FREE-00999 freely available EZB journals; PubMed Central |
subjects | Image Report |
title | Computed Tomographic Characterization of Traumastem-A New Oxidized Cellulose Hemostatic Agent |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-31T23%3A41%3A14IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Computed%20Tomographic%20Characterization%20of%20Traumastem-A%20New%20Oxidized%20Cellulose%20Hemostatic%20Agent&rft.jtitle=Tomography%20(Ann%20Arbor)&rft.au=Lewis,%20Paul%20B&rft.date=2016-09&rft.volume=2&rft.issue=3&rft.spage=175&rft.epage=178&rft.pages=175-178&rft.issn=2379-139X&rft.eissn=2379-139X&rft_id=info:doi/10.18383/j.tom.2016.00238&rft_dat=%3Cproquest_pubme%3E2076241883%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c329t-55cdced574bdfc06e138d6567bbb2d930157b4a9b8030d9fbe725f52cd49cf983%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2076241883&rft_id=info:pmid/30042962&rfr_iscdi=true |