Loading…
Application of a robotic THz imaging system for sub-surface analysis of ancient human remains
We used a robotic-based THz imaging system to investigate the sub-surface structure of an artificially mummified ancient Egyptian human left hand. The results obtained are compared to the results of a conventional CT and a micro-CT scan. Using such a robotic THz system promises new insights into the...
Saved in:
Published in: | Scientific reports 2019-03, Vol.9 (1), p.3390-3390, Article 3390 |
---|---|
Main Authors: | , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c474t-d98a1385f5d87383935790d9e4884d36ae140e25030c71f72db6362d789b6a4c3 |
---|---|
cites | cdi_FETCH-LOGICAL-c474t-d98a1385f5d87383935790d9e4884d36ae140e25030c71f72db6362d789b6a4c3 |
container_end_page | 3390 |
container_issue | 1 |
container_start_page | 3390 |
container_title | Scientific reports |
container_volume | 9 |
creator | Stübling, Eva-Maria Rehn, Arno Siebrecht, Tabea Bauckhage, Yannick Öhrström, Lena Eppenberger, Patrick Balzer, Jan C. Rühli, Frank Koch, Martin |
description | We used a robotic-based THz imaging system to investigate the sub-surface structure of an artificially mummified ancient Egyptian human left hand. The results obtained are compared to the results of a conventional CT and a micro-CT scan. Using such a robotic THz system promises new insights into the sub-surface structure of human remains. The depth resolution of the THz images exceeds the resolution of a conventional CT scan and is comparable with a micro-CT scan. The advantage of THz measurements over micro-CT scans is the fact that even comparatively large samples, like complete bodies, can be scanned. These would not fit into a conventional micro-CT scanner. |
doi_str_mv | 10.1038/s41598-019-40211-7 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6399258</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2187936236</sourcerecordid><originalsourceid>FETCH-LOGICAL-c474t-d98a1385f5d87383935790d9e4884d36ae140e25030c71f72db6362d789b6a4c3</originalsourceid><addsrcrecordid>eNp9kUFvFSEUhYnR2Kb2D7gwJG7cjAKXGWBj0jRqmzRxU5eGMAzzSjMDT-6MyfPXS9-rbXUhG0jud889l0PIa87ecwb6A0reGt0wbhrJBOeNekaOBZNtI0CI50_eR-QU8ZbV0wojuXlJjoBpAAXdMfl-tt1O0bsl5kTzSB0tuc9L9PT64heNs9vEtKG4wyXMdMyF4to3uJbR-UBdctMOI-4bk48hLfRmnV2iJcwuJnxFXoxuwnB6f5-Qb58_XZ9fNFdfv1yen101Xiq5NIPRjoNux3bQCjQYaJVhgwlSazlA5wKXLIiWAfOKj0oMfQedGJQ2feekhxPy8aC7Xfs5DL4aKW6y21IXKDubXbR_V1K8sZv803ZgjGh1FXh3L1DyjzXgYueIPkyTSyGvaAXXWjDN-R369h_0Nq-l_sSeUqYag65S4kD5khFLGB_McGbvArSHAG0N0O4DtKo2vXm6xkPLn7gqAAcAayltQnmc_R_Z38BWpdw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2187936236</pqid></control><display><type>article</type><title>Application of a robotic THz imaging system for sub-surface analysis of ancient human remains</title><source>Open Access: PubMed Central</source><source>Full-Text Journals in Chemistry (Open access)</source><source>Publicly Available Content (ProQuest)</source><source>Springer Nature - nature.com Journals - Fully Open Access</source><creator>Stübling, Eva-Maria ; Rehn, Arno ; Siebrecht, Tabea ; Bauckhage, Yannick ; Öhrström, Lena ; Eppenberger, Patrick ; Balzer, Jan C. ; Rühli, Frank ; Koch, Martin</creator><creatorcontrib>Stübling, Eva-Maria ; Rehn, Arno ; Siebrecht, Tabea ; Bauckhage, Yannick ; Öhrström, Lena ; Eppenberger, Patrick ; Balzer, Jan C. ; Rühli, Frank ; Koch, Martin</creatorcontrib><description>We used a robotic-based THz imaging system to investigate the sub-surface structure of an artificially mummified ancient Egyptian human left hand. The results obtained are compared to the results of a conventional CT and a micro-CT scan. Using such a robotic THz system promises new insights into the sub-surface structure of human remains. The depth resolution of the THz images exceeds the resolution of a conventional CT scan and is comparable with a micro-CT scan. The advantage of THz measurements over micro-CT scans is the fact that even comparatively large samples, like complete bodies, can be scanned. These would not fit into a conventional micro-CT scanner.</description><identifier>ISSN: 2045-2322</identifier><identifier>EISSN: 2045-2322</identifier><identifier>DOI: 10.1038/s41598-019-40211-7</identifier><identifier>PMID: 30833736</identifier><language>eng</language><publisher>London: Nature Publishing Group UK</publisher><subject>639/166/985 ; 639/624/1111 ; 639/766/930/2735 ; Computed tomography ; Human remains ; Humanities and Social Sciences ; Medical imaging ; multidisciplinary ; Robotics ; Science ; Science (multidisciplinary) ; Tomography</subject><ispartof>Scientific reports, 2019-03, Vol.9 (1), p.3390-3390, Article 3390</ispartof><rights>The Author(s) 2019</rights><rights>This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c474t-d98a1385f5d87383935790d9e4884d36ae140e25030c71f72db6362d789b6a4c3</citedby><cites>FETCH-LOGICAL-c474t-d98a1385f5d87383935790d9e4884d36ae140e25030c71f72db6362d789b6a4c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2187936236/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2187936236?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,25753,27924,27925,37012,37013,44590,53791,53793,75126</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30833736$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Stübling, Eva-Maria</creatorcontrib><creatorcontrib>Rehn, Arno</creatorcontrib><creatorcontrib>Siebrecht, Tabea</creatorcontrib><creatorcontrib>Bauckhage, Yannick</creatorcontrib><creatorcontrib>Öhrström, Lena</creatorcontrib><creatorcontrib>Eppenberger, Patrick</creatorcontrib><creatorcontrib>Balzer, Jan C.</creatorcontrib><creatorcontrib>Rühli, Frank</creatorcontrib><creatorcontrib>Koch, Martin</creatorcontrib><title>Application of a robotic THz imaging system for sub-surface analysis of ancient human remains</title><title>Scientific reports</title><addtitle>Sci Rep</addtitle><addtitle>Sci Rep</addtitle><description>We used a robotic-based THz imaging system to investigate the sub-surface structure of an artificially mummified ancient Egyptian human left hand. The results obtained are compared to the results of a conventional CT and a micro-CT scan. Using such a robotic THz system promises new insights into the sub-surface structure of human remains. The depth resolution of the THz images exceeds the resolution of a conventional CT scan and is comparable with a micro-CT scan. The advantage of THz measurements over micro-CT scans is the fact that even comparatively large samples, like complete bodies, can be scanned. These would not fit into a conventional micro-CT scanner.</description><subject>639/166/985</subject><subject>639/624/1111</subject><subject>639/766/930/2735</subject><subject>Computed tomography</subject><subject>Human remains</subject><subject>Humanities and Social Sciences</subject><subject>Medical imaging</subject><subject>multidisciplinary</subject><subject>Robotics</subject><subject>Science</subject><subject>Science (multidisciplinary)</subject><subject>Tomography</subject><issn>2045-2322</issn><issn>2045-2322</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNp9kUFvFSEUhYnR2Kb2D7gwJG7cjAKXGWBj0jRqmzRxU5eGMAzzSjMDT-6MyfPXS9-rbXUhG0jud889l0PIa87ecwb6A0reGt0wbhrJBOeNekaOBZNtI0CI50_eR-QU8ZbV0wojuXlJjoBpAAXdMfl-tt1O0bsl5kTzSB0tuc9L9PT64heNs9vEtKG4wyXMdMyF4to3uJbR-UBdctMOI-4bk48hLfRmnV2iJcwuJnxFXoxuwnB6f5-Qb58_XZ9fNFdfv1yen101Xiq5NIPRjoNux3bQCjQYaJVhgwlSazlA5wKXLIiWAfOKj0oMfQedGJQ2feekhxPy8aC7Xfs5DL4aKW6y21IXKDubXbR_V1K8sZv803ZgjGh1FXh3L1DyjzXgYueIPkyTSyGvaAXXWjDN-R369h_0Nq-l_sSeUqYag65S4kD5khFLGB_McGbvArSHAG0N0O4DtKo2vXm6xkPLn7gqAAcAayltQnmc_R_Z38BWpdw</recordid><startdate>20190304</startdate><enddate>20190304</enddate><creator>Stübling, Eva-Maria</creator><creator>Rehn, Arno</creator><creator>Siebrecht, Tabea</creator><creator>Bauckhage, Yannick</creator><creator>Öhrström, Lena</creator><creator>Eppenberger, Patrick</creator><creator>Balzer, Jan C.</creator><creator>Rühli, Frank</creator><creator>Koch, Martin</creator><general>Nature Publishing Group UK</general><general>Nature Publishing Group</general><scope>C6C</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>88A</scope><scope>88E</scope><scope>88I</scope><scope>8FE</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M2P</scope><scope>M7P</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>Q9U</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20190304</creationdate><title>Application of a robotic THz imaging system for sub-surface analysis of ancient human remains</title><author>Stübling, Eva-Maria ; Rehn, Arno ; Siebrecht, Tabea ; Bauckhage, Yannick ; Öhrström, Lena ; Eppenberger, Patrick ; Balzer, Jan C. ; Rühli, Frank ; Koch, Martin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c474t-d98a1385f5d87383935790d9e4884d36ae140e25030c71f72db6362d789b6a4c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>639/166/985</topic><topic>639/624/1111</topic><topic>639/766/930/2735</topic><topic>Computed tomography</topic><topic>Human remains</topic><topic>Humanities and Social Sciences</topic><topic>Medical imaging</topic><topic>multidisciplinary</topic><topic>Robotics</topic><topic>Science</topic><topic>Science (multidisciplinary)</topic><topic>Tomography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Stübling, Eva-Maria</creatorcontrib><creatorcontrib>Rehn, Arno</creatorcontrib><creatorcontrib>Siebrecht, Tabea</creatorcontrib><creatorcontrib>Bauckhage, Yannick</creatorcontrib><creatorcontrib>Öhrström, Lena</creatorcontrib><creatorcontrib>Eppenberger, Patrick</creatorcontrib><creatorcontrib>Balzer, Jan C.</creatorcontrib><creatorcontrib>Rühli, Frank</creatorcontrib><creatorcontrib>Koch, Martin</creatorcontrib><collection>Springer Nature OA Free Journals</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>ProQuest Health and Medical</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Biology Database (Alumni Edition)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Science Database (Alumni Edition)</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>ProQuest Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>PML(ProQuest Medical Library)</collection><collection>ProQuest Science Journals</collection><collection>ProQuest Biological Science Journals</collection><collection>Publicly Available Content (ProQuest)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Scientific reports</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Stübling, Eva-Maria</au><au>Rehn, Arno</au><au>Siebrecht, Tabea</au><au>Bauckhage, Yannick</au><au>Öhrström, Lena</au><au>Eppenberger, Patrick</au><au>Balzer, Jan C.</au><au>Rühli, Frank</au><au>Koch, Martin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Application of a robotic THz imaging system for sub-surface analysis of ancient human remains</atitle><jtitle>Scientific reports</jtitle><stitle>Sci Rep</stitle><addtitle>Sci Rep</addtitle><date>2019-03-04</date><risdate>2019</risdate><volume>9</volume><issue>1</issue><spage>3390</spage><epage>3390</epage><pages>3390-3390</pages><artnum>3390</artnum><issn>2045-2322</issn><eissn>2045-2322</eissn><abstract>We used a robotic-based THz imaging system to investigate the sub-surface structure of an artificially mummified ancient Egyptian human left hand. The results obtained are compared to the results of a conventional CT and a micro-CT scan. Using such a robotic THz system promises new insights into the sub-surface structure of human remains. The depth resolution of the THz images exceeds the resolution of a conventional CT scan and is comparable with a micro-CT scan. The advantage of THz measurements over micro-CT scans is the fact that even comparatively large samples, like complete bodies, can be scanned. These would not fit into a conventional micro-CT scanner.</abstract><cop>London</cop><pub>Nature Publishing Group UK</pub><pmid>30833736</pmid><doi>10.1038/s41598-019-40211-7</doi><tpages>1</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2045-2322 |
ispartof | Scientific reports, 2019-03, Vol.9 (1), p.3390-3390, Article 3390 |
issn | 2045-2322 2045-2322 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6399258 |
source | Open Access: PubMed Central; Full-Text Journals in Chemistry (Open access); Publicly Available Content (ProQuest); Springer Nature - nature.com Journals - Fully Open Access |
subjects | 639/166/985 639/624/1111 639/766/930/2735 Computed tomography Human remains Humanities and Social Sciences Medical imaging multidisciplinary Robotics Science Science (multidisciplinary) Tomography |
title | Application of a robotic THz imaging system for sub-surface analysis of ancient human remains |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T04%3A08%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Application%20of%20a%20robotic%20THz%20imaging%20system%20for%20sub-surface%20analysis%20of%20ancient%20human%20remains&rft.jtitle=Scientific%20reports&rft.au=St%C3%BCbling,%20Eva-Maria&rft.date=2019-03-04&rft.volume=9&rft.issue=1&rft.spage=3390&rft.epage=3390&rft.pages=3390-3390&rft.artnum=3390&rft.issn=2045-2322&rft.eissn=2045-2322&rft_id=info:doi/10.1038/s41598-019-40211-7&rft_dat=%3Cproquest_pubme%3E2187936236%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c474t-d98a1385f5d87383935790d9e4884d36ae140e25030c71f72db6362d789b6a4c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2187936236&rft_id=info:pmid/30833736&rfr_iscdi=true |