Implementation of Semiautomated Antimicrobial Susceptibility Interpretation Hardware for Nontuberculous Mycobacteria May Overestimate Susceptibility

Nontuberculous mycobacteria (NTM) cause severe opportunistic infections and have a rising incidence in most settings. Rising diagnostic need must be met by national reference laboratories, which rely on Clinical and Laboratory Standards Institute (CLSI) guideline-approved manual readout of microtite...

Full description

Saved in:
Bibliographic Details
Published in:Journal of clinical microbiology 2019-04, Vol.57 (4)
Main Authors: Rockland, Mariëlle, Ruth, Mike Marvin, Aalders, Nicole, Pennings, Lian, Hoefsloot, Wouter, Wattenberg, Melanie, van Ingen, Jakko
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c384t-9d6b4c34777cda39c756cc0c58633a2d0388ad6a166ec354f4b794cf8b0d43d63
cites cdi_FETCH-LOGICAL-c384t-9d6b4c34777cda39c756cc0c58633a2d0388ad6a166ec354f4b794cf8b0d43d63
container_end_page
container_issue 4
container_start_page
container_title Journal of clinical microbiology
container_volume 57
creator Rockland, Mariëlle
Ruth, Mike Marvin
Aalders, Nicole
Pennings, Lian
Hoefsloot, Wouter
Wattenberg, Melanie
van Ingen, Jakko
description Nontuberculous mycobacteria (NTM) cause severe opportunistic infections and have a rising incidence in most settings. Rising diagnostic need must be met by national reference laboratories, which rely on Clinical and Laboratory Standards Institute (CLSI) guideline-approved manual readout of microtiter plates for antimicrobial susceptibility testing (AST) to determine antibiotic minimum inhibitory concentrations (MICs). Interpretation of these plates leads to different outcomes between laboratories. The SensiTitre Vizion digital MIC viewing system (Vizion) offers a more streamlined approach using semiautomated reading. Here, we conducted a blinded trial comparing the outcome of AST between manual readout and Vizion readout for 132 NTM isolates, amounting to 727 individual tests for antibiotic susceptibility ranging across 13 individual antibiotics with established CLSI breakpoints. From this, we calculated specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) and the F1 value, as well as assessing major error (ME) and very major error (VME) rates. We find that Vizion-assisted AST produces significantly lower MICs (paired Wilcox signed rank test; < 0.0001). The Vizion had an accuracy of 89,40%, producing 61 MEs (8.39%) and 16 VMEs (2.20%). The calculated specificity was 0.8370, the sensitivity was 0.9550, the PPV was 0.8460, the NPV was 0.9520, and the F1 score was 0.8970. We show that discrepant readings mostly stem from CLSI guideline breakpoints being close to, or overlapping, the MIC values, leading to small discrepancies crossing the breakpoint, contributing to VMEs and MEs. Using the Vizion in standard clinical diagnostics for NTM might lead to an overestimation of antibiotic susceptibility.
doi_str_mv 10.1128/JCM.01756-18
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6440788</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2200773378</sourcerecordid><originalsourceid>FETCH-LOGICAL-c384t-9d6b4c34777cda39c756cc0c58633a2d0388ad6a166ec354f4b794cf8b0d43d63</originalsourceid><addsrcrecordid>eNpdkUFv1DAQhS0Eokvhxhn5yIGU8dqxnQtStSp0UZceChI3a2I7YJTEwXGK9n_wg_HSpQJOPvibN_PeI-Q5gzPG1vr1-83uDJiqZcX0A7Ji0OhKSvj8kKwAmrpijKsT8mSevwEwIer6MTnhoCTUHFbk53aYej_4MWMOcaSxozd-CLjkOGD2jp6POQzBptgG7OnNMls_5dCGPuQ93Y7Zpyn54_AlJvcDk6ddTPRDHPPS-mSXPi4z3e1tbNEWPiDd4Z5e3_rk5yJe1vyn-5Q86rCf_bPje0o-vb34uLmsrq7fbTfnV5XlWuSqcbIVlgullHXIG1tCsBZsrSXnuHbAtUYnkUnpLa9FJ1rVCNvpFpzgTvJT8uZOd1rawTtbUkjYmymVo9LeRAzm358xfDVf4q2RQoDSugi8PAqk-H0pbswQipG-x9EX02a9BlCKc3VAX92hJcp5Tr67X8PAHIo0pUjzu0jDDviLv0-7h_80x38BO7mfWQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2200773378</pqid></control><display><type>article</type><title>Implementation of Semiautomated Antimicrobial Susceptibility Interpretation Hardware for Nontuberculous Mycobacteria May Overestimate Susceptibility</title><source>PubMed Central Free</source><source>American Society for Microbiology Journals</source><creator>Rockland, Mariëlle ; Ruth, Mike Marvin ; Aalders, Nicole ; Pennings, Lian ; Hoefsloot, Wouter ; Wattenberg, Melanie ; van Ingen, Jakko</creator><contributor>Land, Geoffrey A.</contributor><creatorcontrib>Rockland, Mariëlle ; Ruth, Mike Marvin ; Aalders, Nicole ; Pennings, Lian ; Hoefsloot, Wouter ; Wattenberg, Melanie ; van Ingen, Jakko ; Land, Geoffrey A.</creatorcontrib><description>Nontuberculous mycobacteria (NTM) cause severe opportunistic infections and have a rising incidence in most settings. Rising diagnostic need must be met by national reference laboratories, which rely on Clinical and Laboratory Standards Institute (CLSI) guideline-approved manual readout of microtiter plates for antimicrobial susceptibility testing (AST) to determine antibiotic minimum inhibitory concentrations (MICs). Interpretation of these plates leads to different outcomes between laboratories. The SensiTitre Vizion digital MIC viewing system (Vizion) offers a more streamlined approach using semiautomated reading. Here, we conducted a blinded trial comparing the outcome of AST between manual readout and Vizion readout for 132 NTM isolates, amounting to 727 individual tests for antibiotic susceptibility ranging across 13 individual antibiotics with established CLSI breakpoints. From this, we calculated specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) and the F1 value, as well as assessing major error (ME) and very major error (VME) rates. We find that Vizion-assisted AST produces significantly lower MICs (paired Wilcox signed rank test; &lt; 0.0001). The Vizion had an accuracy of 89,40%, producing 61 MEs (8.39%) and 16 VMEs (2.20%). The calculated specificity was 0.8370, the sensitivity was 0.9550, the PPV was 0.8460, the NPV was 0.9520, and the F1 score was 0.8970. We show that discrepant readings mostly stem from CLSI guideline breakpoints being close to, or overlapping, the MIC values, leading to small discrepancies crossing the breakpoint, contributing to VMEs and MEs. Using the Vizion in standard clinical diagnostics for NTM might lead to an overestimation of antibiotic susceptibility.</description><identifier>ISSN: 0095-1137</identifier><identifier>EISSN: 1098-660X</identifier><identifier>DOI: 10.1128/JCM.01756-18</identifier><identifier>PMID: 30760530</identifier><language>eng</language><publisher>United States: American Society for Microbiology</publisher><subject>Anti-Bacterial Agents - pharmacology ; Humans ; Microbial Sensitivity Tests - instrumentation ; Microbial Sensitivity Tests - standards ; Mycobacteriology and Aerobic Actinomycetes ; Mycobacterium Infections, Nontuberculous - diagnosis ; Mycobacterium Infections, Nontuberculous - microbiology ; Nontuberculous Mycobacteria - drug effects ; Nontuberculous Mycobacteria - isolation &amp; purification ; Sensitivity and Specificity</subject><ispartof>Journal of clinical microbiology, 2019-04, Vol.57 (4)</ispartof><rights>Copyright © 2019 American Society for Microbiology.</rights><rights>Copyright © 2019 American Society for Microbiology. 2019 American Society for Microbiology</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c384t-9d6b4c34777cda39c756cc0c58633a2d0388ad6a166ec354f4b794cf8b0d43d63</citedby><cites>FETCH-LOGICAL-c384t-9d6b4c34777cda39c756cc0c58633a2d0388ad6a166ec354f4b794cf8b0d43d63</cites><orcidid>0000-0002-0581-2003 ; 0000-0003-3343-6823 ; 0000-0003-0281-4895</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6440788/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6440788/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,3188,27924,27925,53791,53793</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30760530$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><contributor>Land, Geoffrey A.</contributor><creatorcontrib>Rockland, Mariëlle</creatorcontrib><creatorcontrib>Ruth, Mike Marvin</creatorcontrib><creatorcontrib>Aalders, Nicole</creatorcontrib><creatorcontrib>Pennings, Lian</creatorcontrib><creatorcontrib>Hoefsloot, Wouter</creatorcontrib><creatorcontrib>Wattenberg, Melanie</creatorcontrib><creatorcontrib>van Ingen, Jakko</creatorcontrib><title>Implementation of Semiautomated Antimicrobial Susceptibility Interpretation Hardware for Nontuberculous Mycobacteria May Overestimate Susceptibility</title><title>Journal of clinical microbiology</title><addtitle>J Clin Microbiol</addtitle><description>Nontuberculous mycobacteria (NTM) cause severe opportunistic infections and have a rising incidence in most settings. Rising diagnostic need must be met by national reference laboratories, which rely on Clinical and Laboratory Standards Institute (CLSI) guideline-approved manual readout of microtiter plates for antimicrobial susceptibility testing (AST) to determine antibiotic minimum inhibitory concentrations (MICs). Interpretation of these plates leads to different outcomes between laboratories. The SensiTitre Vizion digital MIC viewing system (Vizion) offers a more streamlined approach using semiautomated reading. Here, we conducted a blinded trial comparing the outcome of AST between manual readout and Vizion readout for 132 NTM isolates, amounting to 727 individual tests for antibiotic susceptibility ranging across 13 individual antibiotics with established CLSI breakpoints. From this, we calculated specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) and the F1 value, as well as assessing major error (ME) and very major error (VME) rates. We find that Vizion-assisted AST produces significantly lower MICs (paired Wilcox signed rank test; &lt; 0.0001). The Vizion had an accuracy of 89,40%, producing 61 MEs (8.39%) and 16 VMEs (2.20%). The calculated specificity was 0.8370, the sensitivity was 0.9550, the PPV was 0.8460, the NPV was 0.9520, and the F1 score was 0.8970. We show that discrepant readings mostly stem from CLSI guideline breakpoints being close to, or overlapping, the MIC values, leading to small discrepancies crossing the breakpoint, contributing to VMEs and MEs. Using the Vizion in standard clinical diagnostics for NTM might lead to an overestimation of antibiotic susceptibility.</description><subject>Anti-Bacterial Agents - pharmacology</subject><subject>Humans</subject><subject>Microbial Sensitivity Tests - instrumentation</subject><subject>Microbial Sensitivity Tests - standards</subject><subject>Mycobacteriology and Aerobic Actinomycetes</subject><subject>Mycobacterium Infections, Nontuberculous - diagnosis</subject><subject>Mycobacterium Infections, Nontuberculous - microbiology</subject><subject>Nontuberculous Mycobacteria - drug effects</subject><subject>Nontuberculous Mycobacteria - isolation &amp; purification</subject><subject>Sensitivity and Specificity</subject><issn>0095-1137</issn><issn>1098-660X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNpdkUFv1DAQhS0Eokvhxhn5yIGU8dqxnQtStSp0UZceChI3a2I7YJTEwXGK9n_wg_HSpQJOPvibN_PeI-Q5gzPG1vr1-83uDJiqZcX0A7Ji0OhKSvj8kKwAmrpijKsT8mSevwEwIer6MTnhoCTUHFbk53aYej_4MWMOcaSxozd-CLjkOGD2jp6POQzBptgG7OnNMls_5dCGPuQ93Y7Zpyn54_AlJvcDk6ddTPRDHPPS-mSXPi4z3e1tbNEWPiDd4Z5e3_rk5yJe1vyn-5Q86rCf_bPje0o-vb34uLmsrq7fbTfnV5XlWuSqcbIVlgullHXIG1tCsBZsrSXnuHbAtUYnkUnpLa9FJ1rVCNvpFpzgTvJT8uZOd1rawTtbUkjYmymVo9LeRAzm358xfDVf4q2RQoDSugi8PAqk-H0pbswQipG-x9EX02a9BlCKc3VAX92hJcp5Tr67X8PAHIo0pUjzu0jDDviLv0-7h_80x38BO7mfWQ</recordid><startdate>20190401</startdate><enddate>20190401</enddate><creator>Rockland, Mariëlle</creator><creator>Ruth, Mike Marvin</creator><creator>Aalders, Nicole</creator><creator>Pennings, Lian</creator><creator>Hoefsloot, Wouter</creator><creator>Wattenberg, Melanie</creator><creator>van Ingen, Jakko</creator><general>American Society for Microbiology</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-0581-2003</orcidid><orcidid>https://orcid.org/0000-0003-3343-6823</orcidid><orcidid>https://orcid.org/0000-0003-0281-4895</orcidid></search><sort><creationdate>20190401</creationdate><title>Implementation of Semiautomated Antimicrobial Susceptibility Interpretation Hardware for Nontuberculous Mycobacteria May Overestimate Susceptibility</title><author>Rockland, Mariëlle ; Ruth, Mike Marvin ; Aalders, Nicole ; Pennings, Lian ; Hoefsloot, Wouter ; Wattenberg, Melanie ; van Ingen, Jakko</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c384t-9d6b4c34777cda39c756cc0c58633a2d0388ad6a166ec354f4b794cf8b0d43d63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Anti-Bacterial Agents - pharmacology</topic><topic>Humans</topic><topic>Microbial Sensitivity Tests - instrumentation</topic><topic>Microbial Sensitivity Tests - standards</topic><topic>Mycobacteriology and Aerobic Actinomycetes</topic><topic>Mycobacterium Infections, Nontuberculous - diagnosis</topic><topic>Mycobacterium Infections, Nontuberculous - microbiology</topic><topic>Nontuberculous Mycobacteria - drug effects</topic><topic>Nontuberculous Mycobacteria - isolation &amp; purification</topic><topic>Sensitivity and Specificity</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Rockland, Mariëlle</creatorcontrib><creatorcontrib>Ruth, Mike Marvin</creatorcontrib><creatorcontrib>Aalders, Nicole</creatorcontrib><creatorcontrib>Pennings, Lian</creatorcontrib><creatorcontrib>Hoefsloot, Wouter</creatorcontrib><creatorcontrib>Wattenberg, Melanie</creatorcontrib><creatorcontrib>van Ingen, Jakko</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of clinical microbiology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Rockland, Mariëlle</au><au>Ruth, Mike Marvin</au><au>Aalders, Nicole</au><au>Pennings, Lian</au><au>Hoefsloot, Wouter</au><au>Wattenberg, Melanie</au><au>van Ingen, Jakko</au><au>Land, Geoffrey A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Implementation of Semiautomated Antimicrobial Susceptibility Interpretation Hardware for Nontuberculous Mycobacteria May Overestimate Susceptibility</atitle><jtitle>Journal of clinical microbiology</jtitle><addtitle>J Clin Microbiol</addtitle><date>2019-04-01</date><risdate>2019</risdate><volume>57</volume><issue>4</issue><issn>0095-1137</issn><eissn>1098-660X</eissn><abstract>Nontuberculous mycobacteria (NTM) cause severe opportunistic infections and have a rising incidence in most settings. Rising diagnostic need must be met by national reference laboratories, which rely on Clinical and Laboratory Standards Institute (CLSI) guideline-approved manual readout of microtiter plates for antimicrobial susceptibility testing (AST) to determine antibiotic minimum inhibitory concentrations (MICs). Interpretation of these plates leads to different outcomes between laboratories. The SensiTitre Vizion digital MIC viewing system (Vizion) offers a more streamlined approach using semiautomated reading. Here, we conducted a blinded trial comparing the outcome of AST between manual readout and Vizion readout for 132 NTM isolates, amounting to 727 individual tests for antibiotic susceptibility ranging across 13 individual antibiotics with established CLSI breakpoints. From this, we calculated specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) and the F1 value, as well as assessing major error (ME) and very major error (VME) rates. We find that Vizion-assisted AST produces significantly lower MICs (paired Wilcox signed rank test; &lt; 0.0001). The Vizion had an accuracy of 89,40%, producing 61 MEs (8.39%) and 16 VMEs (2.20%). The calculated specificity was 0.8370, the sensitivity was 0.9550, the PPV was 0.8460, the NPV was 0.9520, and the F1 score was 0.8970. We show that discrepant readings mostly stem from CLSI guideline breakpoints being close to, or overlapping, the MIC values, leading to small discrepancies crossing the breakpoint, contributing to VMEs and MEs. Using the Vizion in standard clinical diagnostics for NTM might lead to an overestimation of antibiotic susceptibility.</abstract><cop>United States</cop><pub>American Society for Microbiology</pub><pmid>30760530</pmid><doi>10.1128/JCM.01756-18</doi><orcidid>https://orcid.org/0000-0002-0581-2003</orcidid><orcidid>https://orcid.org/0000-0003-3343-6823</orcidid><orcidid>https://orcid.org/0000-0003-0281-4895</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0095-1137
ispartof Journal of clinical microbiology, 2019-04, Vol.57 (4)
issn 0095-1137
1098-660X
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6440788
source PubMed Central Free; American Society for Microbiology Journals
subjects Anti-Bacterial Agents - pharmacology
Humans
Microbial Sensitivity Tests - instrumentation
Microbial Sensitivity Tests - standards
Mycobacteriology and Aerobic Actinomycetes
Mycobacterium Infections, Nontuberculous - diagnosis
Mycobacterium Infections, Nontuberculous - microbiology
Nontuberculous Mycobacteria - drug effects
Nontuberculous Mycobacteria - isolation & purification
Sensitivity and Specificity
title Implementation of Semiautomated Antimicrobial Susceptibility Interpretation Hardware for Nontuberculous Mycobacteria May Overestimate Susceptibility
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T21%3A38%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Implementation%20of%20Semiautomated%20Antimicrobial%20Susceptibility%20Interpretation%20Hardware%20for%20Nontuberculous%20Mycobacteria%20May%20Overestimate%20Susceptibility&rft.jtitle=Journal%20of%20clinical%20microbiology&rft.au=Rockland,%20Mari%C3%ABlle&rft.date=2019-04-01&rft.volume=57&rft.issue=4&rft.issn=0095-1137&rft.eissn=1098-660X&rft_id=info:doi/10.1128/JCM.01756-18&rft_dat=%3Cproquest_pubme%3E2200773378%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c384t-9d6b4c34777cda39c756cc0c58633a2d0388ad6a166ec354f4b794cf8b0d43d63%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2200773378&rft_id=info:pmid/30760530&rfr_iscdi=true