Loading…

A comparative evaluation of fracture load of monolithic and bilayered zirconia crowns with and without a cervical collar: an in vitro study

The use of zirconia based all-ceramic restorations are preferred nowadays owing to superior biologic and esthetic properties. However, these restorations have also reported higher incidences of fracture and chipping. The clinical success may be enhanced by optimizing the core design, through the int...

Full description

Saved in:
Bibliographic Details
Published in:Medicine and pharmacy reports 2019-04, Vol.92 (2), p.172-177
Main Authors: Saha, Mainak Kanti, Bansal, Surbhi, Pathak, Vandana, Bhardwaj, Shivani, Chauhan, Astha, Nirwan, Amit Singh
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The use of zirconia based all-ceramic restorations are preferred nowadays owing to superior biologic and esthetic properties. However, these restorations have also reported higher incidences of fracture and chipping. The clinical success may be enhanced by optimizing the core design, through the introduction of monolithic zirconia, or the layered crowns can be strengthened by adding the cervical collar to them. This study was performed with the objective to compare and evaluate the fracture load of monolithic and bilayered zirconia crowns with and without a cervical collar. A prospective observational study was carried out to compare 45 fabricated zirconia crowns of three different designs on a customized metal mould. The samples were oriented on the metal mould and subjected to confocal microscope for the evaluation of marginal integrity followed by cementing the crown on the metal mould and subjecting it to the universal testing machine for the analysis for the flexural strength. Data were analyzed using one way Anova and t- test for inter and intra groups. The significance level was set at ≤ 0.05. The monolith zirconia crowns and layered zirconia crowns with cervical collar reported more flexural strength. The amount of force required to fracture the zirconia crowns was higher in the case of monolith zirconia crown and layered zirconia crown with cervical collar as compared to the layered zirconia crown without cervical collar.
ISSN:2602-0807
2668-0572
DOI:10.15386/mpr-985