Description of interference in the measurement of troponin T by a high-sensitivity method

Introduction: Measurement of high-sensitivity troponin T (hs-TnT) has become an essential step in the diagnosis of acute myocardial infarction. This high-sensitivity method allows quantifying the concentration of troponin T in blood of healthy subjects with a lower inaccuracy compared to previous re...

Full description

Saved in:
Bibliographic Details
Published in:Biochemia Medica 2019-06, Vol.29 (2), p.413-419
Main Authors: Aliste-Fernández, Miguel, Sole-Enrech, Gemma, Cano-Corres, Ruth, Teodoro-Marin, Silvia, Berlanga-Escalera, Eugenio
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Introduction: Measurement of high-sensitivity troponin T (hs-TnT) has become an essential step in the diagnosis of acute myocardial infarction. This high-sensitivity method allows quantifying the concentration of troponin T in blood of healthy subjects with a lower inaccuracy compared to previous reagent generations. However, the presence of certain compounds in the sample may interfere with the result. We present a patient who had repeatedly high concentrations of hs-TnT in the serum sample that did not agreed with the signs and symptoms. In addition, ultrasensitive troponin I concentration was undetectable. Materials and methods: To investigate the presence of an interfering compound, different analysis were carried out. In order to discard macro complexes in the sample, the serum was precipitated with polyethylene glycol. In addition, the serum was incubated with Scantibodies Heterophilic Blocking Tube, which can block heterophilic antibodies. Finally, a size exclusion chromatography of the sample was performed by the manufacturer. What happened: The interfering substance was allocated into fractions with proteins of 150kDa, corresponding to high molecular weight proteins like immunoglobulin G (IgG). This compound was responsible for the falsely elevated hs-TnT results and it affected only the high-sensitivity methods. Main lesson: The detected interfering compound was probably an IgG. This type of interference must be kept in mind in front of discordant results, even if they are extremely rare. Therefore, interdisciplinary cooperation between clinicians, laboratory and manufacturer is essential.
ISSN:1330-0962
1846-7482
DOI:10.11613/BM.2019.021001