Jotec E-Ventus BX Stent Graft Deployment in the FEVAR and Iliac Branch Device: Single Centre Experience
Objectives: To evaluate the outcomes of the E-ventus BX balloon-expandable stent graft system (Jotec, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) and the iliac branch device (IBD) of complex aneurysms.Methods: This was a single centre...
Saved in:
Published in: | Annals of Vascular Diseases 2019/06/25, Vol.12(2), pp.171-175 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c475t-a7089732bf801bb53df8f3e42cab90db1ce51b19d5e8cd168fd2de9be84bef993 |
---|---|
cites | cdi_FETCH-LOGICAL-c475t-a7089732bf801bb53df8f3e42cab90db1ce51b19d5e8cd168fd2de9be84bef993 |
container_end_page | 175 |
container_issue | 2 |
container_start_page | 171 |
container_title | Annals of Vascular Diseases |
container_volume | 12 |
creator | Sayed, Tamer Ahmed, Islam Rodway, Alexander Sakka, Karim El Yusuf, Syed Waquar |
description | Objectives: To evaluate the outcomes of the E-ventus BX balloon-expandable stent graft system (Jotec, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) and the iliac branch device (IBD) of complex aneurysms.Methods: This was a single centre retrospective analysis prospective study including all consecutive patients treated by FEVAR and the IBD performed with E-ventus BX stent grafts as bridging stents. Demographics of patients, the diameter and length of the bridging stent grafts, technical success, reinterventions, occlusions, post-operative events, and imaging (computed tomography [CT] scan and ultrasound) were prospectively collected in an electronic database. Follow-ups were performed with clinical assessment and a CT angiogram scan at four weeks after discharge followed by a duplex ultrasound every six months for two years and then a yearly duplex scan afterwards.Results: Between June 2015 and October 2017, 40 consecutive patients (three females) were treated with custom made fenestrated endografts and the iliac branch device for complex aneurysms, using the E-Ventus BX stent graft. All 82 E-Ventus BX stent grafts were successfully delivered and deployed. There was no in-hospital mortality. The early bridging stents patency rate was 97.6% (80 out of 82). The two-target vessel post-operative occlusion was secondary to kink of the renal stents and failure for re-lining of the renal artery. Of the two patients, only one needed permanent dialysis. On the late follow-up (after 30 days), two other patients demonstrated a renal stent occlusion, with one treated successfully with re-lining of the stent and the other patient treated conservatively. Neither of them needed permanent dialysis. A follow-up was maintained for 36 patients until April 2018 with a median follow-up of 18 months. All bridging stents E-Ventus BX stent grafts remained patent (78 out of 82, 95.1%).Conclusion: E-Ventus BX stent grafts used as bridging stents during FEVAR and the IBD are associated with favourable outcomes at the mid-term follow-up. Long-term follow-up is required to confirm these promising results. |
doi_str_mv | 10.3400/avd.oa.18-00101 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6600105</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2253284489</sourcerecordid><originalsourceid>FETCH-LOGICAL-c475t-a7089732bf801bb53df8f3e42cab90db1ce51b19d5e8cd168fd2de9be84bef993</originalsourceid><addsrcrecordid>eNpVkc1PGzEQxa2KqkDac2-Vj1w22N6PeHuoBGFJgyJVKi3KzfLHbGK08QbbieC_7y6hq3CxR57fvDfyQ-grJeM0I-RS7s24lWPKE0IooR_QGeWcJkXG-MlQ0-UpOg_hkZCiKEr-CZ2mlE3yrCjP0OqujaBxlTyAi7uAr5f4PnYlnnlZR3wD26Z92fQP1uG4BnxbPVz9xtIZPG-s1PjaS6fXHbi3Gr7je-tWDeBpN-EBV89b8Bachs_oYy2bAF_e7hH6e1v9mf5MFr9m8-nVItHZJI-JnBBeTlKmak6oUnlqal6nkDEtVUmMohpyqmhpcuDa0ILXhhkoFfBMQV2W6Qj9OOhud2oDRvd7yEZsvd1I_yJaacX7jrNrsWr3oij6H8w7gYs3Ad8-7SBEsbFBQ9NIB-0uCMbylPEs473X5QHVvg3BQz3YUCL6eEQXT2cpKBev8XQT3463G_j_eXRAdQAeQ5QrGADpo9UNvApSJlh_HAkPfb2WXoBL_wHVhKYq</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2253284489</pqid></control><display><type>article</type><title>Jotec E-Ventus BX Stent Graft Deployment in the FEVAR and Iliac Branch Device: Single Centre Experience</title><source>PubMed Central</source><creator>Sayed, Tamer ; Ahmed, Islam ; Rodway, Alexander ; Sakka, Karim El ; Yusuf, Syed Waquar</creator><creatorcontrib>Sayed, Tamer ; Ahmed, Islam ; Rodway, Alexander ; Sakka, Karim El ; Yusuf, Syed Waquar</creatorcontrib><description>Objectives: To evaluate the outcomes of the E-ventus BX balloon-expandable stent graft system (Jotec, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) and the iliac branch device (IBD) of complex aneurysms.Methods: This was a single centre retrospective analysis prospective study including all consecutive patients treated by FEVAR and the IBD performed with E-ventus BX stent grafts as bridging stents. Demographics of patients, the diameter and length of the bridging stent grafts, technical success, reinterventions, occlusions, post-operative events, and imaging (computed tomography [CT] scan and ultrasound) were prospectively collected in an electronic database. Follow-ups were performed with clinical assessment and a CT angiogram scan at four weeks after discharge followed by a duplex ultrasound every six months for two years and then a yearly duplex scan afterwards.Results: Between June 2015 and October 2017, 40 consecutive patients (three females) were treated with custom made fenestrated endografts and the iliac branch device for complex aneurysms, using the E-Ventus BX stent graft. All 82 E-Ventus BX stent grafts were successfully delivered and deployed. There was no in-hospital mortality. The early bridging stents patency rate was 97.6% (80 out of 82). The two-target vessel post-operative occlusion was secondary to kink of the renal stents and failure for re-lining of the renal artery. Of the two patients, only one needed permanent dialysis. On the late follow-up (after 30 days), two other patients demonstrated a renal stent occlusion, with one treated successfully with re-lining of the stent and the other patient treated conservatively. Neither of them needed permanent dialysis. A follow-up was maintained for 36 patients until April 2018 with a median follow-up of 18 months. All bridging stents E-Ventus BX stent grafts remained patent (78 out of 82, 95.1%).Conclusion: E-Ventus BX stent grafts used as bridging stents during FEVAR and the IBD are associated with favourable outcomes at the mid-term follow-up. Long-term follow-up is required to confirm these promising results.</description><identifier>ISSN: 1881-641X</identifier><identifier>EISSN: 1881-6428</identifier><identifier>DOI: 10.3400/avd.oa.18-00101</identifier><identifier>PMID: 31275469</identifier><language>eng</language><publisher>Japan: The Editorial Committee of Annals of Vascular Diseases</publisher><subject>aortic aneurysm ; bridging stents ; E-Ventus ; FEVAR ; IBD ; Original</subject><ispartof>Annals of Vascular Diseases, 2019/06/25, Vol.12(2), pp.171-175</ispartof><rights>2019 The Editorial Committee of Annals of Vascular Diseases. This article is distributed under the terms of the Creative Commons Attribution License, which permits use, distribution, and reproduction in any medium, provided the credit of the original work, a link to the license, and indication of any change are properly given, and the original work is not used for commercial purposes. Remixed or transformed contributions must be distributed under the same license as the original.</rights><rights>Copyright © 2019 Annals of Vascular Diseases 2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c475t-a7089732bf801bb53df8f3e42cab90db1ce51b19d5e8cd168fd2de9be84bef993</citedby><cites>FETCH-LOGICAL-c475t-a7089732bf801bb53df8f3e42cab90db1ce51b19d5e8cd168fd2de9be84bef993</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6600105/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6600105/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,27903,27904,53770,53772</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31275469$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Sayed, Tamer</creatorcontrib><creatorcontrib>Ahmed, Islam</creatorcontrib><creatorcontrib>Rodway, Alexander</creatorcontrib><creatorcontrib>Sakka, Karim El</creatorcontrib><creatorcontrib>Yusuf, Syed Waquar</creatorcontrib><title>Jotec E-Ventus BX Stent Graft Deployment in the FEVAR and Iliac Branch Device: Single Centre Experience</title><title>Annals of Vascular Diseases</title><addtitle>Annals of Vascular Diseases</addtitle><description>Objectives: To evaluate the outcomes of the E-ventus BX balloon-expandable stent graft system (Jotec, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) and the iliac branch device (IBD) of complex aneurysms.Methods: This was a single centre retrospective analysis prospective study including all consecutive patients treated by FEVAR and the IBD performed with E-ventus BX stent grafts as bridging stents. Demographics of patients, the diameter and length of the bridging stent grafts, technical success, reinterventions, occlusions, post-operative events, and imaging (computed tomography [CT] scan and ultrasound) were prospectively collected in an electronic database. Follow-ups were performed with clinical assessment and a CT angiogram scan at four weeks after discharge followed by a duplex ultrasound every six months for two years and then a yearly duplex scan afterwards.Results: Between June 2015 and October 2017, 40 consecutive patients (three females) were treated with custom made fenestrated endografts and the iliac branch device for complex aneurysms, using the E-Ventus BX stent graft. All 82 E-Ventus BX stent grafts were successfully delivered and deployed. There was no in-hospital mortality. The early bridging stents patency rate was 97.6% (80 out of 82). The two-target vessel post-operative occlusion was secondary to kink of the renal stents and failure for re-lining of the renal artery. Of the two patients, only one needed permanent dialysis. On the late follow-up (after 30 days), two other patients demonstrated a renal stent occlusion, with one treated successfully with re-lining of the stent and the other patient treated conservatively. Neither of them needed permanent dialysis. A follow-up was maintained for 36 patients until April 2018 with a median follow-up of 18 months. All bridging stents E-Ventus BX stent grafts remained patent (78 out of 82, 95.1%).Conclusion: E-Ventus BX stent grafts used as bridging stents during FEVAR and the IBD are associated with favourable outcomes at the mid-term follow-up. Long-term follow-up is required to confirm these promising results.</description><subject>aortic aneurysm</subject><subject>bridging stents</subject><subject>E-Ventus</subject><subject>FEVAR</subject><subject>IBD</subject><subject>Original</subject><issn>1881-641X</issn><issn>1881-6428</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNpVkc1PGzEQxa2KqkDac2-Vj1w22N6PeHuoBGFJgyJVKi3KzfLHbGK08QbbieC_7y6hq3CxR57fvDfyQ-grJeM0I-RS7s24lWPKE0IooR_QGeWcJkXG-MlQ0-UpOg_hkZCiKEr-CZ2mlE3yrCjP0OqujaBxlTyAi7uAr5f4PnYlnnlZR3wD26Z92fQP1uG4BnxbPVz9xtIZPG-s1PjaS6fXHbi3Gr7je-tWDeBpN-EBV89b8Bachs_oYy2bAF_e7hH6e1v9mf5MFr9m8-nVItHZJI-JnBBeTlKmak6oUnlqal6nkDEtVUmMohpyqmhpcuDa0ILXhhkoFfBMQV2W6Qj9OOhud2oDRvd7yEZsvd1I_yJaacX7jrNrsWr3oij6H8w7gYs3Ad8-7SBEsbFBQ9NIB-0uCMbylPEs473X5QHVvg3BQz3YUCL6eEQXT2cpKBev8XQT3463G_j_eXRAdQAeQ5QrGADpo9UNvApSJlh_HAkPfb2WXoBL_wHVhKYq</recordid><startdate>20190625</startdate><enddate>20190625</enddate><creator>Sayed, Tamer</creator><creator>Ahmed, Islam</creator><creator>Rodway, Alexander</creator><creator>Sakka, Karim El</creator><creator>Yusuf, Syed Waquar</creator><general>The Editorial Committee of Annals of Vascular Diseases</general><general>Japanese College of Angiology / The Japanese Society for Vascular Surgery / Japanese Society of Phlebology</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20190625</creationdate><title>Jotec E-Ventus BX Stent Graft Deployment in the FEVAR and Iliac Branch Device: Single Centre Experience</title><author>Sayed, Tamer ; Ahmed, Islam ; Rodway, Alexander ; Sakka, Karim El ; Yusuf, Syed Waquar</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c475t-a7089732bf801bb53df8f3e42cab90db1ce51b19d5e8cd168fd2de9be84bef993</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>aortic aneurysm</topic><topic>bridging stents</topic><topic>E-Ventus</topic><topic>FEVAR</topic><topic>IBD</topic><topic>Original</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sayed, Tamer</creatorcontrib><creatorcontrib>Ahmed, Islam</creatorcontrib><creatorcontrib>Rodway, Alexander</creatorcontrib><creatorcontrib>Sakka, Karim El</creatorcontrib><creatorcontrib>Yusuf, Syed Waquar</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Annals of Vascular Diseases</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sayed, Tamer</au><au>Ahmed, Islam</au><au>Rodway, Alexander</au><au>Sakka, Karim El</au><au>Yusuf, Syed Waquar</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Jotec E-Ventus BX Stent Graft Deployment in the FEVAR and Iliac Branch Device: Single Centre Experience</atitle><jtitle>Annals of Vascular Diseases</jtitle><addtitle>Annals of Vascular Diseases</addtitle><date>2019-06-25</date><risdate>2019</risdate><volume>12</volume><issue>2</issue><spage>171</spage><epage>175</epage><pages>171-175</pages><issn>1881-641X</issn><eissn>1881-6428</eissn><abstract>Objectives: To evaluate the outcomes of the E-ventus BX balloon-expandable stent graft system (Jotec, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) and the iliac branch device (IBD) of complex aneurysms.Methods: This was a single centre retrospective analysis prospective study including all consecutive patients treated by FEVAR and the IBD performed with E-ventus BX stent grafts as bridging stents. Demographics of patients, the diameter and length of the bridging stent grafts, technical success, reinterventions, occlusions, post-operative events, and imaging (computed tomography [CT] scan and ultrasound) were prospectively collected in an electronic database. Follow-ups were performed with clinical assessment and a CT angiogram scan at four weeks after discharge followed by a duplex ultrasound every six months for two years and then a yearly duplex scan afterwards.Results: Between June 2015 and October 2017, 40 consecutive patients (three females) were treated with custom made fenestrated endografts and the iliac branch device for complex aneurysms, using the E-Ventus BX stent graft. All 82 E-Ventus BX stent grafts were successfully delivered and deployed. There was no in-hospital mortality. The early bridging stents patency rate was 97.6% (80 out of 82). The two-target vessel post-operative occlusion was secondary to kink of the renal stents and failure for re-lining of the renal artery. Of the two patients, only one needed permanent dialysis. On the late follow-up (after 30 days), two other patients demonstrated a renal stent occlusion, with one treated successfully with re-lining of the stent and the other patient treated conservatively. Neither of them needed permanent dialysis. A follow-up was maintained for 36 patients until April 2018 with a median follow-up of 18 months. All bridging stents E-Ventus BX stent grafts remained patent (78 out of 82, 95.1%).Conclusion: E-Ventus BX stent grafts used as bridging stents during FEVAR and the IBD are associated with favourable outcomes at the mid-term follow-up. Long-term follow-up is required to confirm these promising results.</abstract><cop>Japan</cop><pub>The Editorial Committee of Annals of Vascular Diseases</pub><pmid>31275469</pmid><doi>10.3400/avd.oa.18-00101</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1881-641X |
ispartof | Annals of Vascular Diseases, 2019/06/25, Vol.12(2), pp.171-175 |
issn | 1881-641X 1881-6428 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6600105 |
source | PubMed Central |
subjects | aortic aneurysm bridging stents E-Ventus FEVAR IBD Original |
title | Jotec E-Ventus BX Stent Graft Deployment in the FEVAR and Iliac Branch Device: Single Centre Experience |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T12%3A22%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Jotec%20E-Ventus%20BX%20Stent%20Graft%20Deployment%20in%20the%20FEVAR%20and%20Iliac%20Branch%20Device:%20Single%20Centre%20Experience&rft.jtitle=Annals%20of%20Vascular%20Diseases&rft.au=Sayed,%20Tamer&rft.date=2019-06-25&rft.volume=12&rft.issue=2&rft.spage=171&rft.epage=175&rft.pages=171-175&rft.issn=1881-641X&rft.eissn=1881-6428&rft_id=info:doi/10.3400/avd.oa.18-00101&rft_dat=%3Cproquest_pubme%3E2253284489%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c475t-a7089732bf801bb53df8f3e42cab90db1ce51b19d5e8cd168fd2de9be84bef993%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2253284489&rft_id=info:pmid/31275469&rfr_iscdi=true |