Neutron flux intercomparison at NBS

National Bureau of Standards (NBS) participation in an International Bureau of Weights and Measures (BIPM) sponsored neutron flux intercomparison is described. The efficiencies of two transfer instruments, a gas-filled 3 He proportional counter and a BF 3 counter imbedded in a polyethylene sphere, w...

Full description

Saved in:
Bibliographic Details
Published in:Journal of research of the National Bureau of Standards (1977) 1978-11, Vol.83 (6), p.555-561
Main Authors: Duvall, K.C., Meier, M.M., Wasson, O.A., Huynh, V.D.
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c386t-34e584b76cedae765cabbe71b1d956517059b0e62bedb2568b2588345367cd113
cites
container_end_page 561
container_issue 6
container_start_page 555
container_title Journal of research of the National Bureau of Standards (1977)
container_volume 83
creator Duvall, K.C.
Meier, M.M.
Wasson, O.A.
Huynh, V.D.
description National Bureau of Standards (NBS) participation in an International Bureau of Weights and Measures (BIPM) sponsored neutron flux intercomparison is described. The efficiencies of two transfer instruments, a gas-filled 3 He proportional counter and a BF 3 counter imbedded in a polyethylene sphere, were determined at neutron energies of 250 keV and 560 keV. The efficiency of the 3 He detector was determined by placing it in the flux monitored by the NBS “black” detector. Since the polyethylene sphere detector shadows the “black” detector, a secondary BF 3 counter was calibrated and it normalized the sphere and “black” detector runs. The efficiencies are reported and compared to the quantities determined at other participating standards laboratories.
doi_str_mv 10.6028/jres.083.037
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6752636</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2576917482</sourcerecordid><originalsourceid>FETCH-LOGICAL-c386t-34e584b76cedae765cabbe71b1d956517059b0e62bedb2568b2588345367cd113</originalsourceid><addsrcrecordid>eNpVkE1LAzEQhoMotlZv_oCCFw9uzcdmkr0IWvyCUg_qOSTZqW7Zj5rsiv57UyqClxlm5uV9h4eQU0ZnQLm-XAeMM6rFjAq1R8ZcKMgkl8U-GVMGNGMqZyNyFOOaUimAFodkJHIJkMYxOVvi0Ieuna7q4WtatT0G3zUbG6qYlrafLm-ej8nBytYRT377hLze3b7MH7LF0_3j_HqReaGhz0SOUudOgcfSogLprXOomGNlIUEyRWXhKAJ3WDouQaeidXpFgPIlY2JCrna-m8E1WHps-2BrswlVY8O36Wxl_l_a6t28dZ8GlOQgIBmc_xqE7mPA2Jumih7r2rbYDdFwqaBIPDRP0oud1IcuxoCrvxhGzZar2XI1iatJXMUPK_Jp2A</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2576917482</pqid></control><display><type>article</type><title>Neutron flux intercomparison at NBS</title><source>PubMed Central</source><creator>Duvall, K.C. ; Meier, M.M. ; Wasson, O.A. ; Huynh, V.D.</creator><creatorcontrib>Duvall, K.C. ; Meier, M.M. ; Wasson, O.A. ; Huynh, V.D.</creatorcontrib><description>National Bureau of Standards (NBS) participation in an International Bureau of Weights and Measures (BIPM) sponsored neutron flux intercomparison is described. The efficiencies of two transfer instruments, a gas-filled 3 He proportional counter and a BF 3 counter imbedded in a polyethylene sphere, were determined at neutron energies of 250 keV and 560 keV. The efficiency of the 3 He detector was determined by placing it in the flux monitored by the NBS “black” detector. Since the polyethylene sphere detector shadows the “black” detector, a secondary BF 3 counter was calibrated and it normalized the sphere and “black” detector runs. The efficiencies are reported and compared to the quantities determined at other participating standards laboratories.</description><identifier>ISSN: 0160-1741</identifier><identifier>EISSN: 2376-5259</identifier><identifier>DOI: 10.6028/jres.083.037</identifier><identifier>PMID: 34566005</identifier><language>eng</language><publisher>National Institute of Standards and Technology</publisher><subject>Physics and Chemistry</subject><ispartof>Journal of research of the National Bureau of Standards (1977), 1978-11, Vol.83 (6), p.555-561</ispartof><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c386t-34e584b76cedae765cabbe71b1d956517059b0e62bedb2568b2588345367cd113</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6752636/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6752636/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids></links><search><creatorcontrib>Duvall, K.C.</creatorcontrib><creatorcontrib>Meier, M.M.</creatorcontrib><creatorcontrib>Wasson, O.A.</creatorcontrib><creatorcontrib>Huynh, V.D.</creatorcontrib><title>Neutron flux intercomparison at NBS</title><title>Journal of research of the National Bureau of Standards (1977)</title><description>National Bureau of Standards (NBS) participation in an International Bureau of Weights and Measures (BIPM) sponsored neutron flux intercomparison is described. The efficiencies of two transfer instruments, a gas-filled 3 He proportional counter and a BF 3 counter imbedded in a polyethylene sphere, were determined at neutron energies of 250 keV and 560 keV. The efficiency of the 3 He detector was determined by placing it in the flux monitored by the NBS “black” detector. Since the polyethylene sphere detector shadows the “black” detector, a secondary BF 3 counter was calibrated and it normalized the sphere and “black” detector runs. The efficiencies are reported and compared to the quantities determined at other participating standards laboratories.</description><subject>Physics and Chemistry</subject><issn>0160-1741</issn><issn>2376-5259</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1978</creationdate><recordtype>article</recordtype><recordid>eNpVkE1LAzEQhoMotlZv_oCCFw9uzcdmkr0IWvyCUg_qOSTZqW7Zj5rsiv57UyqClxlm5uV9h4eQU0ZnQLm-XAeMM6rFjAq1R8ZcKMgkl8U-GVMGNGMqZyNyFOOaUimAFodkJHIJkMYxOVvi0Ieuna7q4WtatT0G3zUbG6qYlrafLm-ej8nBytYRT377hLze3b7MH7LF0_3j_HqReaGhz0SOUudOgcfSogLprXOomGNlIUEyRWXhKAJ3WDouQaeidXpFgPIlY2JCrna-m8E1WHps-2BrswlVY8O36Wxl_l_a6t28dZ8GlOQgIBmc_xqE7mPA2Jumih7r2rbYDdFwqaBIPDRP0oud1IcuxoCrvxhGzZar2XI1iatJXMUPK_Jp2A</recordid><startdate>19781101</startdate><enddate>19781101</enddate><creator>Duvall, K.C.</creator><creator>Meier, M.M.</creator><creator>Wasson, O.A.</creator><creator>Huynh, V.D.</creator><general>National Institute of Standards and Technology</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>19781101</creationdate><title>Neutron flux intercomparison at NBS</title><author>Duvall, K.C. ; Meier, M.M. ; Wasson, O.A. ; Huynh, V.D.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c386t-34e584b76cedae765cabbe71b1d956517059b0e62bedb2568b2588345367cd113</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1978</creationdate><topic>Physics and Chemistry</topic><toplevel>online_resources</toplevel><creatorcontrib>Duvall, K.C.</creatorcontrib><creatorcontrib>Meier, M.M.</creatorcontrib><creatorcontrib>Wasson, O.A.</creatorcontrib><creatorcontrib>Huynh, V.D.</creatorcontrib><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of research of the National Bureau of Standards (1977)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Duvall, K.C.</au><au>Meier, M.M.</au><au>Wasson, O.A.</au><au>Huynh, V.D.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Neutron flux intercomparison at NBS</atitle><jtitle>Journal of research of the National Bureau of Standards (1977)</jtitle><date>1978-11-01</date><risdate>1978</risdate><volume>83</volume><issue>6</issue><spage>555</spage><epage>561</epage><pages>555-561</pages><issn>0160-1741</issn><eissn>2376-5259</eissn><abstract>National Bureau of Standards (NBS) participation in an International Bureau of Weights and Measures (BIPM) sponsored neutron flux intercomparison is described. The efficiencies of two transfer instruments, a gas-filled 3 He proportional counter and a BF 3 counter imbedded in a polyethylene sphere, were determined at neutron energies of 250 keV and 560 keV. The efficiency of the 3 He detector was determined by placing it in the flux monitored by the NBS “black” detector. Since the polyethylene sphere detector shadows the “black” detector, a secondary BF 3 counter was calibrated and it normalized the sphere and “black” detector runs. The efficiencies are reported and compared to the quantities determined at other participating standards laboratories.</abstract><pub>National Institute of Standards and Technology</pub><pmid>34566005</pmid><doi>10.6028/jres.083.037</doi><tpages>7</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0160-1741
ispartof Journal of research of the National Bureau of Standards (1977), 1978-11, Vol.83 (6), p.555-561
issn 0160-1741
2376-5259
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6752636
source PubMed Central
subjects Physics and Chemistry
title Neutron flux intercomparison at NBS
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T21%3A57%3A25IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Neutron%20flux%20intercomparison%20at%20NBS&rft.jtitle=Journal%20of%20research%20of%20the%20National%20Bureau%20of%20Standards%20(1977)&rft.au=Duvall,%20K.C.&rft.date=1978-11-01&rft.volume=83&rft.issue=6&rft.spage=555&rft.epage=561&rft.pages=555-561&rft.issn=0160-1741&rft.eissn=2376-5259&rft_id=info:doi/10.6028/jres.083.037&rft_dat=%3Cproquest_pubme%3E2576917482%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c386t-34e584b76cedae765cabbe71b1d956517059b0e62bedb2568b2588345367cd113%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2576917482&rft_id=info:pmid/34566005&rfr_iscdi=true