Urethral pressure profilometry in artificial urinary sphincter implantation: A case report

Artificial urethral sphincter (AUS) implantation is currently the gold standard for treating moderate and severe urinary incontinence. Currently, cuffs are chosen based on the surgeon's experience, and adjusting cuff tightness is crucial. The T-DOC air-charged catheter has not been proven to be...

Full description

Saved in:
Bibliographic Details
Published in:World journal of clinical cases 2019-12, Vol.7 (23), p.4084-4090
Main Authors: Meng, Ling-Feng, Liu, Xiao-Dong, Wang, Miao, Zhang, Wei, Zhang, Yao-Guang
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Artificial urethral sphincter (AUS) implantation is currently the gold standard for treating moderate and severe urinary incontinence. Currently, cuffs are chosen based on the surgeon's experience, and adjusting cuff tightness is crucial. The T-DOC air-charged catheter has not been proven to be inferior to traditional catheters. We report how intraoperative urethral pressure profilometry is performed using a T-DOC air-charged catheter with ambulatory urodynamic equipment, to guide cuff selection and adjustment. A 67-year-old man presented to our hospital with complete urinary incontinence following transurethral prostatectomy, using five pads/d to maintain local dryness. Preoperatively, the maximum urethral pressure (MUP) and maximum urethral closure pressure (MUCP) were 52 cmH2O and 17 cmH2O, respectively. An AUS was implanted. Intraoperatively, in the inactivated state, the MUP and MUCP were 53 cmH2O and 50 cmH2O, respectively; in the activated state, they were 112 cmH2O and 109 cmH2O, respectively. The pump was activated 6 wk postoperatively. Re-measurement of the urethral pressure on the same day showed that in the inactivated state, MUP and MUCP were 89 cmH2O and 51 cmH2O, respectively, and in the activated state, 120 cmH2O and 92 cmH2O, respectively. One month after device activation, telephonic follow-up revealed that pad use had decreased from five pads/d to one pad/d, which met the standard for social continence (0-1 pad per day). There were no complications. The relationship between intraoperative urethral pressure and urinary continence post-surgery can provide data for standardizing AUS implantation and evaluating efficacy.
ISSN:2307-8960
2307-8960
DOI:10.12998/wjcc.v7.i23.4084