Loading…

Fracture Resistance of Partial Indirect Restorations Made With CAD/CAM Technology. A Systematic Review and Meta-analysis

The aim of this systematic review and meta-analysis was to determine the fracture resistance and survival rate of partial indirect restorations inlays, onlays, and overlays fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technology from ceramics, composite resin, re...

Full description

Saved in:
Bibliographic Details
Published in:Journal of clinical medicine 2019-11, Vol.8 (11), p.1932
Main Authors: Amesti-Garaizabal, Amaia, Agustín-Panadero, Rubén, Verdejo-Solá, Blanca, Fons-Font, Antonio, Fernández-Estevan, Lucía, Montiel-Company, Jose, Solá-Ruíz, María Fernanda
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c378t-1f9e940d376233055191e2d0e8ac9349f9d9314f971849a245a4cea48b9016583
cites cdi_FETCH-LOGICAL-c378t-1f9e940d376233055191e2d0e8ac9349f9d9314f971849a245a4cea48b9016583
container_end_page
container_issue 11
container_start_page 1932
container_title Journal of clinical medicine
container_volume 8
creator Amesti-Garaizabal, Amaia
Agustín-Panadero, Rubén
Verdejo-Solá, Blanca
Fons-Font, Antonio
Fernández-Estevan, Lucía
Montiel-Company, Jose
Solá-Ruíz, María Fernanda
description The aim of this systematic review and meta-analysis was to determine the fracture resistance and survival rate of partial indirect restorations inlays, onlays, and overlays fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technology from ceramics, composite resin, resin nanoceramic, or hybrid ceramic and to analyze the influence of proximal box elevation on fracture resistance. This systematic review was based on guidelines proposed by the preferred reporting items for systematic reviews and meta-analyses (PRISMA). An electronic search was conducted in databases US National Library of Medicine National Institutes of Health (PubMed), Scopus, Web of Science (WOS), and Embase. In vitro trials published during the last 10 years were included in the review. Applying inclusion criteria based on the review's population, intervention, comparison, outcome (PICO) question, 13 articles were selected. Meta-analysis by restoration type estimated the fracture resistance of inlays to be 1923.45 Newtons (N); of onlays 1644 N and of overlays 1383.6 N. Meta-analysis by restoration material obtained an estimated fracture resistance for ceramic of 1529.5 N, for composite resin of 1600 Ne, for resin nanoceramic 2478.7 N, and hybrid ceramic 2108 N. Resin nanoceramic inlays present significantly higher fracture resistance values. Proximal box elevation does not exert any influence on the fracture resistance of indirect restorations.
doi_str_mv 10.3390/jcm8111932
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6912690</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2314251048</sourcerecordid><originalsourceid>FETCH-LOGICAL-c378t-1f9e940d376233055191e2d0e8ac9349f9d9314f971849a245a4cea48b9016583</originalsourceid><addsrcrecordid>eNpVUV1LHTEQDdJSxfrSHyB5FGE1X7ubvAiXa62Clxa19DGM2VlvZDfRJNf2_nv3orV2XmbgnDlnmEPIF86OpDTs-N6NmnNupNgiO4K1bcWklh_ezdtkL-d7NpXWSvD2E9mWvOVtw9kO-XOWwJVVQnqF2ecCwSGNPf0BqXgY6EXofEJXNnCJCYqPIdMFdEh_-bKk89np8Xy2oDfoliEO8W59RGf0ep0LjhPZTXtPHn9TCB1dYIEKAgzryekz-djDkHHvte-Sn2dfb-bn1eX3bxfz2WXlZKtLxXuDRrFOto2QktU1NxxFx1CDM1KZ3nRGctWblmtlQKgalENQ-tYw3tRa7pKTF92H1e2IncNQEgz2IfkR0tpG8PZ_JPilvYtPtjFcNIZNAgevAik-rqYv2NFnh8MAAeMqWzHZi5oztfE6fKG6FHNO2L_ZcGY3adl_aU3k_feHvVH_ZiOfAZAwj7o</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2314251048</pqid></control><display><type>article</type><title>Fracture Resistance of Partial Indirect Restorations Made With CAD/CAM Technology. A Systematic Review and Meta-analysis</title><source>Publicly Available Content Database</source><source>PubMed Central</source><creator>Amesti-Garaizabal, Amaia ; Agustín-Panadero, Rubén ; Verdejo-Solá, Blanca ; Fons-Font, Antonio ; Fernández-Estevan, Lucía ; Montiel-Company, Jose ; Solá-Ruíz, María Fernanda</creator><creatorcontrib>Amesti-Garaizabal, Amaia ; Agustín-Panadero, Rubén ; Verdejo-Solá, Blanca ; Fons-Font, Antonio ; Fernández-Estevan, Lucía ; Montiel-Company, Jose ; Solá-Ruíz, María Fernanda</creatorcontrib><description>The aim of this systematic review and meta-analysis was to determine the fracture resistance and survival rate of partial indirect restorations inlays, onlays, and overlays fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technology from ceramics, composite resin, resin nanoceramic, or hybrid ceramic and to analyze the influence of proximal box elevation on fracture resistance. This systematic review was based on guidelines proposed by the preferred reporting items for systematic reviews and meta-analyses (PRISMA). An electronic search was conducted in databases US National Library of Medicine National Institutes of Health (PubMed), Scopus, Web of Science (WOS), and Embase. In vitro trials published during the last 10 years were included in the review. Applying inclusion criteria based on the review's population, intervention, comparison, outcome (PICO) question, 13 articles were selected. Meta-analysis by restoration type estimated the fracture resistance of inlays to be 1923.45 Newtons (N); of onlays 1644 N and of overlays 1383.6 N. Meta-analysis by restoration material obtained an estimated fracture resistance for ceramic of 1529.5 N, for composite resin of 1600 Ne, for resin nanoceramic 2478.7 N, and hybrid ceramic 2108 N. Resin nanoceramic inlays present significantly higher fracture resistance values. Proximal box elevation does not exert any influence on the fracture resistance of indirect restorations.</description><identifier>ISSN: 2077-0383</identifier><identifier>EISSN: 2077-0383</identifier><identifier>DOI: 10.3390/jcm8111932</identifier><identifier>PMID: 31717610</identifier><language>eng</language><publisher>Switzerland: MDPI</publisher><subject>Review</subject><ispartof>Journal of clinical medicine, 2019-11, Vol.8 (11), p.1932</ispartof><rights>2019 by the authors. 2019</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c378t-1f9e940d376233055191e2d0e8ac9349f9d9314f971849a245a4cea48b9016583</citedby><cites>FETCH-LOGICAL-c378t-1f9e940d376233055191e2d0e8ac9349f9d9314f971849a245a4cea48b9016583</cites><orcidid>0000-0002-3952-7681 ; 0000-0001-7663-6740 ; 0000-0002-7946-6932 ; 0000-0003-2757-6619</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6912690/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC6912690/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,723,776,780,881,27903,27904,36992,53769,53771</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31717610$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Amesti-Garaizabal, Amaia</creatorcontrib><creatorcontrib>Agustín-Panadero, Rubén</creatorcontrib><creatorcontrib>Verdejo-Solá, Blanca</creatorcontrib><creatorcontrib>Fons-Font, Antonio</creatorcontrib><creatorcontrib>Fernández-Estevan, Lucía</creatorcontrib><creatorcontrib>Montiel-Company, Jose</creatorcontrib><creatorcontrib>Solá-Ruíz, María Fernanda</creatorcontrib><title>Fracture Resistance of Partial Indirect Restorations Made With CAD/CAM Technology. A Systematic Review and Meta-analysis</title><title>Journal of clinical medicine</title><addtitle>J Clin Med</addtitle><description>The aim of this systematic review and meta-analysis was to determine the fracture resistance and survival rate of partial indirect restorations inlays, onlays, and overlays fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technology from ceramics, composite resin, resin nanoceramic, or hybrid ceramic and to analyze the influence of proximal box elevation on fracture resistance. This systematic review was based on guidelines proposed by the preferred reporting items for systematic reviews and meta-analyses (PRISMA). An electronic search was conducted in databases US National Library of Medicine National Institutes of Health (PubMed), Scopus, Web of Science (WOS), and Embase. In vitro trials published during the last 10 years were included in the review. Applying inclusion criteria based on the review's population, intervention, comparison, outcome (PICO) question, 13 articles were selected. Meta-analysis by restoration type estimated the fracture resistance of inlays to be 1923.45 Newtons (N); of onlays 1644 N and of overlays 1383.6 N. Meta-analysis by restoration material obtained an estimated fracture resistance for ceramic of 1529.5 N, for composite resin of 1600 Ne, for resin nanoceramic 2478.7 N, and hybrid ceramic 2108 N. Resin nanoceramic inlays present significantly higher fracture resistance values. Proximal box elevation does not exert any influence on the fracture resistance of indirect restorations.</description><subject>Review</subject><issn>2077-0383</issn><issn>2077-0383</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNpVUV1LHTEQDdJSxfrSHyB5FGE1X7ubvAiXa62Clxa19DGM2VlvZDfRJNf2_nv3orV2XmbgnDlnmEPIF86OpDTs-N6NmnNupNgiO4K1bcWklh_ezdtkL-d7NpXWSvD2E9mWvOVtw9kO-XOWwJVVQnqF2ecCwSGNPf0BqXgY6EXofEJXNnCJCYqPIdMFdEh_-bKk89np8Xy2oDfoliEO8W59RGf0ep0LjhPZTXtPHn9TCB1dYIEKAgzryekz-djDkHHvte-Sn2dfb-bn1eX3bxfz2WXlZKtLxXuDRrFOto2QktU1NxxFx1CDM1KZ3nRGctWblmtlQKgalENQ-tYw3tRa7pKTF92H1e2IncNQEgz2IfkR0tpG8PZ_JPilvYtPtjFcNIZNAgevAik-rqYv2NFnh8MAAeMqWzHZi5oztfE6fKG6FHNO2L_ZcGY3adl_aU3k_feHvVH_ZiOfAZAwj7o</recordid><startdate>20191109</startdate><enddate>20191109</enddate><creator>Amesti-Garaizabal, Amaia</creator><creator>Agustín-Panadero, Rubén</creator><creator>Verdejo-Solá, Blanca</creator><creator>Fons-Font, Antonio</creator><creator>Fernández-Estevan, Lucía</creator><creator>Montiel-Company, Jose</creator><creator>Solá-Ruíz, María Fernanda</creator><general>MDPI</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-3952-7681</orcidid><orcidid>https://orcid.org/0000-0001-7663-6740</orcidid><orcidid>https://orcid.org/0000-0002-7946-6932</orcidid><orcidid>https://orcid.org/0000-0003-2757-6619</orcidid></search><sort><creationdate>20191109</creationdate><title>Fracture Resistance of Partial Indirect Restorations Made With CAD/CAM Technology. A Systematic Review and Meta-analysis</title><author>Amesti-Garaizabal, Amaia ; Agustín-Panadero, Rubén ; Verdejo-Solá, Blanca ; Fons-Font, Antonio ; Fernández-Estevan, Lucía ; Montiel-Company, Jose ; Solá-Ruíz, María Fernanda</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c378t-1f9e940d376233055191e2d0e8ac9349f9d9314f971849a245a4cea48b9016583</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Review</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Amesti-Garaizabal, Amaia</creatorcontrib><creatorcontrib>Agustín-Panadero, Rubén</creatorcontrib><creatorcontrib>Verdejo-Solá, Blanca</creatorcontrib><creatorcontrib>Fons-Font, Antonio</creatorcontrib><creatorcontrib>Fernández-Estevan, Lucía</creatorcontrib><creatorcontrib>Montiel-Company, Jose</creatorcontrib><creatorcontrib>Solá-Ruíz, María Fernanda</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of clinical medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Amesti-Garaizabal, Amaia</au><au>Agustín-Panadero, Rubén</au><au>Verdejo-Solá, Blanca</au><au>Fons-Font, Antonio</au><au>Fernández-Estevan, Lucía</au><au>Montiel-Company, Jose</au><au>Solá-Ruíz, María Fernanda</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fracture Resistance of Partial Indirect Restorations Made With CAD/CAM Technology. A Systematic Review and Meta-analysis</atitle><jtitle>Journal of clinical medicine</jtitle><addtitle>J Clin Med</addtitle><date>2019-11-09</date><risdate>2019</risdate><volume>8</volume><issue>11</issue><spage>1932</spage><pages>1932-</pages><issn>2077-0383</issn><eissn>2077-0383</eissn><abstract>The aim of this systematic review and meta-analysis was to determine the fracture resistance and survival rate of partial indirect restorations inlays, onlays, and overlays fabricated using computer-aided design and computer-aided manufacturing (CAD-CAM) technology from ceramics, composite resin, resin nanoceramic, or hybrid ceramic and to analyze the influence of proximal box elevation on fracture resistance. This systematic review was based on guidelines proposed by the preferred reporting items for systematic reviews and meta-analyses (PRISMA). An electronic search was conducted in databases US National Library of Medicine National Institutes of Health (PubMed), Scopus, Web of Science (WOS), and Embase. In vitro trials published during the last 10 years were included in the review. Applying inclusion criteria based on the review's population, intervention, comparison, outcome (PICO) question, 13 articles were selected. Meta-analysis by restoration type estimated the fracture resistance of inlays to be 1923.45 Newtons (N); of onlays 1644 N and of overlays 1383.6 N. Meta-analysis by restoration material obtained an estimated fracture resistance for ceramic of 1529.5 N, for composite resin of 1600 Ne, for resin nanoceramic 2478.7 N, and hybrid ceramic 2108 N. Resin nanoceramic inlays present significantly higher fracture resistance values. Proximal box elevation does not exert any influence on the fracture resistance of indirect restorations.</abstract><cop>Switzerland</cop><pub>MDPI</pub><pmid>31717610</pmid><doi>10.3390/jcm8111932</doi><orcidid>https://orcid.org/0000-0002-3952-7681</orcidid><orcidid>https://orcid.org/0000-0001-7663-6740</orcidid><orcidid>https://orcid.org/0000-0002-7946-6932</orcidid><orcidid>https://orcid.org/0000-0003-2757-6619</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2077-0383
ispartof Journal of clinical medicine, 2019-11, Vol.8 (11), p.1932
issn 2077-0383
2077-0383
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_6912690
source Publicly Available Content Database; PubMed Central
subjects Review
title Fracture Resistance of Partial Indirect Restorations Made With CAD/CAM Technology. A Systematic Review and Meta-analysis
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-27T02%3A00%3A16IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fracture%20Resistance%20of%20Partial%20Indirect%20Restorations%20Made%20With%20CAD/CAM%20Technology.%20A%20Systematic%20Review%20and%20Meta-analysis&rft.jtitle=Journal%20of%20clinical%20medicine&rft.au=Amesti-Garaizabal,%20Amaia&rft.date=2019-11-09&rft.volume=8&rft.issue=11&rft.spage=1932&rft.pages=1932-&rft.issn=2077-0383&rft.eissn=2077-0383&rft_id=info:doi/10.3390/jcm8111932&rft_dat=%3Cproquest_pubme%3E2314251048%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c378t-1f9e940d376233055191e2d0e8ac9349f9d9314f971849a245a4cea48b9016583%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2314251048&rft_id=info:pmid/31717610&rfr_iscdi=true