Loading…

Spray Drift from a Conventional Axial Fan Airblast Sprayer in a Modern Orchard Work Environment

Abstract Pesticide spray drift represents an important cause of crop damage and farmworker illness, especially among orchard workers. We drew upon exposure characteristics from known human illness cases to design a series of six spray trials that measured drift from a conventional axial fan airblast...

Full description

Saved in:
Bibliographic Details
Published in:Annals of work exposures and health 2018-11, Vol.62 (9), p.1134-1146
Main Authors: Kasner, Edward J, Fenske, Richard A, Hoheisel, Gwen A, Galvin, Kit, Blanco, Magali N, Seto, Edmund Y W, Yost, Michael G
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c420t-65bd7b18d8b2398e48239c742861908ded11e8d7aeffe06495dd53e90c4f4b6c3
cites cdi_FETCH-LOGICAL-c420t-65bd7b18d8b2398e48239c742861908ded11e8d7aeffe06495dd53e90c4f4b6c3
container_end_page 1146
container_issue 9
container_start_page 1134
container_title Annals of work exposures and health
container_volume 62
creator Kasner, Edward J
Fenske, Richard A
Hoheisel, Gwen A
Galvin, Kit
Blanco, Magali N
Seto, Edmund Y W
Yost, Michael G
description Abstract Pesticide spray drift represents an important cause of crop damage and farmworker illness, especially among orchard workers. We drew upon exposure characteristics from known human illness cases to design a series of six spray trials that measured drift from a conventional axial fan airblast sprayer operating in a modern orchard work environment. Polyester line drift samples (n = 270; 45 per trial) were suspended on 15 vertical masts downwind of foliar applications of zinc, molybdenum, and copper micronutrient tracers. Samples were analyzed using inductively coupled plasma mass spectrometry and resulting masses were normalized by sprayer tank mix concentration to create tracer-based drift volume levels. Mixed-effects modeling described these levels in the context of spatial variability and buffers designed to protect workers from drift exposure. Field-based measurements showed evidence of drift up to 52 m downwind, which is approximately 1.7 times greater than the 30 m (100 ft) ‘Application Exclusion Zone’ defined for airblast sprayers by the United States Environmental Protection Agency Worker Protection Standard. When stratified by near (5 m), mid (26 m), and far (52 m) distances, geometric means and standard deviations for drift levels were 257 (1.8), 52 (2.0), and 20 (2.3) µl, respectively. Fixed effect model coefficients showed that higher wind speed [0.53; 95% confidence interval (CI): 0.35, 0.70] and sampling height (0.16; 95% CI: 0.11, 0.20) were positively associated with drift; increasing downwind distance (−0.05; 95% CI: −0.06, −0.04) was negatively associated with drift. Random effects showed large within-location variability, but relatively few systematic changes for individual locations across spray trials after accounting for wind speed, height, and distance. Our study findings demonstrate that buffers may offer drift exposure protection to orchard workers from airblast spraying. Variables such as orchard architecture, sampling height, and wind speed should be included in the evaluation and mitigation of risks from drift exposure. Data from our study may prove useful for estimating potential exposure and validating orchard-based bystander exposure models.
doi_str_mv 10.1093/annweh/wxy082
format article
fullrecord <record><control><sourceid>oup_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7104543</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><oup_id>10.1093/annweh/wxy082</oup_id><sourcerecordid>10.1093/annweh/wxy082</sourcerecordid><originalsourceid>FETCH-LOGICAL-c420t-65bd7b18d8b2398e48239c742861908ded11e8d7aeffe06495dd53e90c4f4b6c3</originalsourceid><addsrcrecordid>eNqFkD1PwzAQhi0EolXpyIo8sqS1Y8dxFqSqtIBU1AEQo-XEDjUkduSkX_-elEAFE8vdSX7uPesB4BKjEUYJGUtrt3o13u72iIcnoB-ShAcxwez0OCPeA8O6fkcI4TiihLBz0COIUEZZ0gfiqfJyD2-9yRuYe1dCCafObrRtjLOygJOdaetcWjgxPi1k3cCvFe2hsS386JT2Fi59tpJewVfnP-DMbox3tmxDLsBZLotaD7_7ALzMZ8_T-2CxvHuYThZBRkPUBCxKVZxirnh6-LemvG1ZTEPOcIK40gpjzVUsdZ5rxGgSKRURnaCM5jRlGRmAmy63WqelVll72stCVN6U0u-Fk0b8fbFmJd7cRsQY0YOWAQi6gMy7uvY6P-5iJA6yRSdbdLJb_ur3wSP9o7YFrjvArat_sj4BATmM1A</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Spray Drift from a Conventional Axial Fan Airblast Sprayer in a Modern Orchard Work Environment</title><source>Oxford Journals Online</source><creator>Kasner, Edward J ; Fenske, Richard A ; Hoheisel, Gwen A ; Galvin, Kit ; Blanco, Magali N ; Seto, Edmund Y W ; Yost, Michael G</creator><creatorcontrib>Kasner, Edward J ; Fenske, Richard A ; Hoheisel, Gwen A ; Galvin, Kit ; Blanco, Magali N ; Seto, Edmund Y W ; Yost, Michael G</creatorcontrib><description>Abstract Pesticide spray drift represents an important cause of crop damage and farmworker illness, especially among orchard workers. We drew upon exposure characteristics from known human illness cases to design a series of six spray trials that measured drift from a conventional axial fan airblast sprayer operating in a modern orchard work environment. Polyester line drift samples (n = 270; 45 per trial) were suspended on 15 vertical masts downwind of foliar applications of zinc, molybdenum, and copper micronutrient tracers. Samples were analyzed using inductively coupled plasma mass spectrometry and resulting masses were normalized by sprayer tank mix concentration to create tracer-based drift volume levels. Mixed-effects modeling described these levels in the context of spatial variability and buffers designed to protect workers from drift exposure. Field-based measurements showed evidence of drift up to 52 m downwind, which is approximately 1.7 times greater than the 30 m (100 ft) ‘Application Exclusion Zone’ defined for airblast sprayers by the United States Environmental Protection Agency Worker Protection Standard. When stratified by near (5 m), mid (26 m), and far (52 m) distances, geometric means and standard deviations for drift levels were 257 (1.8), 52 (2.0), and 20 (2.3) µl, respectively. Fixed effect model coefficients showed that higher wind speed [0.53; 95% confidence interval (CI): 0.35, 0.70] and sampling height (0.16; 95% CI: 0.11, 0.20) were positively associated with drift; increasing downwind distance (−0.05; 95% CI: −0.06, −0.04) was negatively associated with drift. Random effects showed large within-location variability, but relatively few systematic changes for individual locations across spray trials after accounting for wind speed, height, and distance. Our study findings demonstrate that buffers may offer drift exposure protection to orchard workers from airblast spraying. Variables such as orchard architecture, sampling height, and wind speed should be included in the evaluation and mitigation of risks from drift exposure. Data from our study may prove useful for estimating potential exposure and validating orchard-based bystander exposure models.</description><identifier>ISSN: 2398-7308</identifier><identifier>EISSN: 2398-7316</identifier><identifier>DOI: 10.1093/annweh/wxy082</identifier><identifier>PMID: 30346469</identifier><language>eng</language><publisher>UK: Oxford University Press</publisher><subject>Agriculture - methods ; Air Movements ; Air Pollutants - analysis ; Environmental Monitoring - methods ; Humans ; Occupational Exposure - analysis ; Original ; Particulate Matter - analysis ; Pesticides - analysis ; Wind</subject><ispartof>Annals of work exposures and health, 2018-11, Vol.62 (9), p.1134-1146</ispartof><rights>The Author(s) 2018. Published by Oxford University Press on behalf of the British Occupational Hygiene Society. 2018</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c420t-65bd7b18d8b2398e48239c742861908ded11e8d7aeffe06495dd53e90c4f4b6c3</citedby><cites>FETCH-LOGICAL-c420t-65bd7b18d8b2398e48239c742861908ded11e8d7aeffe06495dd53e90c4f4b6c3</cites><orcidid>0000-0002-1077-5286</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27922,27923</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/30346469$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kasner, Edward J</creatorcontrib><creatorcontrib>Fenske, Richard A</creatorcontrib><creatorcontrib>Hoheisel, Gwen A</creatorcontrib><creatorcontrib>Galvin, Kit</creatorcontrib><creatorcontrib>Blanco, Magali N</creatorcontrib><creatorcontrib>Seto, Edmund Y W</creatorcontrib><creatorcontrib>Yost, Michael G</creatorcontrib><title>Spray Drift from a Conventional Axial Fan Airblast Sprayer in a Modern Orchard Work Environment</title><title>Annals of work exposures and health</title><addtitle>Ann Work Expo Health</addtitle><description>Abstract Pesticide spray drift represents an important cause of crop damage and farmworker illness, especially among orchard workers. We drew upon exposure characteristics from known human illness cases to design a series of six spray trials that measured drift from a conventional axial fan airblast sprayer operating in a modern orchard work environment. Polyester line drift samples (n = 270; 45 per trial) were suspended on 15 vertical masts downwind of foliar applications of zinc, molybdenum, and copper micronutrient tracers. Samples were analyzed using inductively coupled plasma mass spectrometry and resulting masses were normalized by sprayer tank mix concentration to create tracer-based drift volume levels. Mixed-effects modeling described these levels in the context of spatial variability and buffers designed to protect workers from drift exposure. Field-based measurements showed evidence of drift up to 52 m downwind, which is approximately 1.7 times greater than the 30 m (100 ft) ‘Application Exclusion Zone’ defined for airblast sprayers by the United States Environmental Protection Agency Worker Protection Standard. When stratified by near (5 m), mid (26 m), and far (52 m) distances, geometric means and standard deviations for drift levels were 257 (1.8), 52 (2.0), and 20 (2.3) µl, respectively. Fixed effect model coefficients showed that higher wind speed [0.53; 95% confidence interval (CI): 0.35, 0.70] and sampling height (0.16; 95% CI: 0.11, 0.20) were positively associated with drift; increasing downwind distance (−0.05; 95% CI: −0.06, −0.04) was negatively associated with drift. Random effects showed large within-location variability, but relatively few systematic changes for individual locations across spray trials after accounting for wind speed, height, and distance. Our study findings demonstrate that buffers may offer drift exposure protection to orchard workers from airblast spraying. Variables such as orchard architecture, sampling height, and wind speed should be included in the evaluation and mitigation of risks from drift exposure. Data from our study may prove useful for estimating potential exposure and validating orchard-based bystander exposure models.</description><subject>Agriculture - methods</subject><subject>Air Movements</subject><subject>Air Pollutants - analysis</subject><subject>Environmental Monitoring - methods</subject><subject>Humans</subject><subject>Occupational Exposure - analysis</subject><subject>Original</subject><subject>Particulate Matter - analysis</subject><subject>Pesticides - analysis</subject><subject>Wind</subject><issn>2398-7308</issn><issn>2398-7316</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2018</creationdate><recordtype>article</recordtype><recordid>eNqFkD1PwzAQhi0EolXpyIo8sqS1Y8dxFqSqtIBU1AEQo-XEDjUkduSkX_-elEAFE8vdSX7uPesB4BKjEUYJGUtrt3o13u72iIcnoB-ShAcxwez0OCPeA8O6fkcI4TiihLBz0COIUEZZ0gfiqfJyD2-9yRuYe1dCCafObrRtjLOygJOdaetcWjgxPi1k3cCvFe2hsS386JT2Fi59tpJewVfnP-DMbox3tmxDLsBZLotaD7_7ALzMZ8_T-2CxvHuYThZBRkPUBCxKVZxirnh6-LemvG1ZTEPOcIK40gpjzVUsdZ5rxGgSKRURnaCM5jRlGRmAmy63WqelVll72stCVN6U0u-Fk0b8fbFmJd7cRsQY0YOWAQi6gMy7uvY6P-5iJA6yRSdbdLJb_ur3wSP9o7YFrjvArat_sj4BATmM1A</recordid><startdate>20181112</startdate><enddate>20181112</enddate><creator>Kasner, Edward J</creator><creator>Fenske, Richard A</creator><creator>Hoheisel, Gwen A</creator><creator>Galvin, Kit</creator><creator>Blanco, Magali N</creator><creator>Seto, Edmund Y W</creator><creator>Yost, Michael G</creator><general>Oxford University Press</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-1077-5286</orcidid></search><sort><creationdate>20181112</creationdate><title>Spray Drift from a Conventional Axial Fan Airblast Sprayer in a Modern Orchard Work Environment</title><author>Kasner, Edward J ; Fenske, Richard A ; Hoheisel, Gwen A ; Galvin, Kit ; Blanco, Magali N ; Seto, Edmund Y W ; Yost, Michael G</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c420t-65bd7b18d8b2398e48239c742861908ded11e8d7aeffe06495dd53e90c4f4b6c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2018</creationdate><topic>Agriculture - methods</topic><topic>Air Movements</topic><topic>Air Pollutants - analysis</topic><topic>Environmental Monitoring - methods</topic><topic>Humans</topic><topic>Occupational Exposure - analysis</topic><topic>Original</topic><topic>Particulate Matter - analysis</topic><topic>Pesticides - analysis</topic><topic>Wind</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kasner, Edward J</creatorcontrib><creatorcontrib>Fenske, Richard A</creatorcontrib><creatorcontrib>Hoheisel, Gwen A</creatorcontrib><creatorcontrib>Galvin, Kit</creatorcontrib><creatorcontrib>Blanco, Magali N</creatorcontrib><creatorcontrib>Seto, Edmund Y W</creatorcontrib><creatorcontrib>Yost, Michael G</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Annals of work exposures and health</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kasner, Edward J</au><au>Fenske, Richard A</au><au>Hoheisel, Gwen A</au><au>Galvin, Kit</au><au>Blanco, Magali N</au><au>Seto, Edmund Y W</au><au>Yost, Michael G</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Spray Drift from a Conventional Axial Fan Airblast Sprayer in a Modern Orchard Work Environment</atitle><jtitle>Annals of work exposures and health</jtitle><addtitle>Ann Work Expo Health</addtitle><date>2018-11-12</date><risdate>2018</risdate><volume>62</volume><issue>9</issue><spage>1134</spage><epage>1146</epage><pages>1134-1146</pages><issn>2398-7308</issn><eissn>2398-7316</eissn><abstract>Abstract Pesticide spray drift represents an important cause of crop damage and farmworker illness, especially among orchard workers. We drew upon exposure characteristics from known human illness cases to design a series of six spray trials that measured drift from a conventional axial fan airblast sprayer operating in a modern orchard work environment. Polyester line drift samples (n = 270; 45 per trial) were suspended on 15 vertical masts downwind of foliar applications of zinc, molybdenum, and copper micronutrient tracers. Samples were analyzed using inductively coupled plasma mass spectrometry and resulting masses were normalized by sprayer tank mix concentration to create tracer-based drift volume levels. Mixed-effects modeling described these levels in the context of spatial variability and buffers designed to protect workers from drift exposure. Field-based measurements showed evidence of drift up to 52 m downwind, which is approximately 1.7 times greater than the 30 m (100 ft) ‘Application Exclusion Zone’ defined for airblast sprayers by the United States Environmental Protection Agency Worker Protection Standard. When stratified by near (5 m), mid (26 m), and far (52 m) distances, geometric means and standard deviations for drift levels were 257 (1.8), 52 (2.0), and 20 (2.3) µl, respectively. Fixed effect model coefficients showed that higher wind speed [0.53; 95% confidence interval (CI): 0.35, 0.70] and sampling height (0.16; 95% CI: 0.11, 0.20) were positively associated with drift; increasing downwind distance (−0.05; 95% CI: −0.06, −0.04) was negatively associated with drift. Random effects showed large within-location variability, but relatively few systematic changes for individual locations across spray trials after accounting for wind speed, height, and distance. Our study findings demonstrate that buffers may offer drift exposure protection to orchard workers from airblast spraying. Variables such as orchard architecture, sampling height, and wind speed should be included in the evaluation and mitigation of risks from drift exposure. Data from our study may prove useful for estimating potential exposure and validating orchard-based bystander exposure models.</abstract><cop>UK</cop><pub>Oxford University Press</pub><pmid>30346469</pmid><doi>10.1093/annweh/wxy082</doi><tpages>13</tpages><orcidid>https://orcid.org/0000-0002-1077-5286</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2398-7308
ispartof Annals of work exposures and health, 2018-11, Vol.62 (9), p.1134-1146
issn 2398-7308
2398-7316
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7104543
source Oxford Journals Online
subjects Agriculture - methods
Air Movements
Air Pollutants - analysis
Environmental Monitoring - methods
Humans
Occupational Exposure - analysis
Original
Particulate Matter - analysis
Pesticides - analysis
Wind
title Spray Drift from a Conventional Axial Fan Airblast Sprayer in a Modern Orchard Work Environment
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T12%3A01%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-oup_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Spray%20Drift%20from%20a%20Conventional%20Axial%20Fan%20Airblast%20Sprayer%20in%20a%20Modern%20Orchard%20Work%20Environment&rft.jtitle=Annals%20of%20work%20exposures%20and%20health&rft.au=Kasner,%20Edward%20J&rft.date=2018-11-12&rft.volume=62&rft.issue=9&rft.spage=1134&rft.epage=1146&rft.pages=1134-1146&rft.issn=2398-7308&rft.eissn=2398-7316&rft_id=info:doi/10.1093/annweh/wxy082&rft_dat=%3Coup_pubme%3E10.1093/annweh/wxy082%3C/oup_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c420t-65bd7b18d8b2398e48239c742861908ded11e8d7aeffe06495dd53e90c4f4b6c3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/30346469&rft_oup_id=10.1093/annweh/wxy082&rfr_iscdi=true