Loading…

Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study

The aim of this study was to construct a novel, repeatable, reproducible, and accurate measurement protocol for the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel remo...

Full description

Saved in:
Bibliographic Details
Published in:Journal of clinical medicine 2020-04, Vol.9 (4), p.1098
Main Authors: Zubizarreta-Macho, Álvaro, Triduo, Martina, Alonso Pérez-Barquero, Jorge, Guinot Barona, Clara, Albaladejo Martínez, Alberto
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c406t-63a0594929e9bd8cb479349f59e0e6480fc0126aa2e1761d4324e2a33ffcdada3
cites cdi_FETCH-LOGICAL-c406t-63a0594929e9bd8cb479349f59e0e6480fc0126aa2e1761d4324e2a33ffcdada3
container_end_page
container_issue 4
container_start_page 1098
container_title Journal of clinical medicine
container_volume 9
creator Zubizarreta-Macho, Álvaro
Triduo, Martina
Alonso Pérez-Barquero, Jorge
Guinot Barona, Clara
Albaladejo Martínez, Alberto
description The aim of this study was to construct a novel, repeatable, reproducible, and accurate measurement protocol for the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere fixed multibracket appliances. A total of 30 brackets were cemented and removed with over 30 extracted teeth embedded into three experimental models of epoxy resin. The models were scanned before and after bracket placement, bracket debonding, and polishing the remaining cement. The brackets were submitted to micro-computed tomography. The standard tessellation language digital files were aligned, segmented, and re-aligned using geomorphometric software. The digital measurement technique accuracy, repeatability, and reproducibility were analyzed using Gage R&R statistical analysis. The variability attributable to the area and volume measurement techniques of the total variability of the samples was 0.70% and 0.11% for repeatability, respectively, and 0.79% and 0.01% for reproducibility, respectively. The re-alignment procedure is a repeatable, reproducible, and accurate technique that can be used to measure the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere the fixed multibracket appliance.
doi_str_mv 10.3390/jcm9041098
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7230799</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2641059084</sourcerecordid><originalsourceid>FETCH-LOGICAL-c406t-63a0594929e9bd8cb479349f59e0e6480fc0126aa2e1761d4324e2a33ffcdada3</originalsourceid><addsrcrecordid>eNpdks1u1DAQgCMEolXphQdAI3FBSAuO7fyYA9Jq20KlAgKWXq2JM9n1ktjBcSr2hXhODC2l4ItHnk-fZjyTZY9z9kIIxV7uzKCYzJmq72WHnFXVgola3L8TH2TH07Rj6dS15Hn1MDsQnCtWFPIw-_HeX1EPJ3ZjI_awJrN19ttMED18nNFF2-0hbgmWgRDQtXDp-3kg8B2saCAX4RMNaJ11m9_pU4dDEqbHJG4Bu0gBzuz3FL-b-2ibgOYrRViOY2_RGYL1lgKOezihxrs2eV7B0sG5g0sbg4fPcW73j7IHHfYTHd_cR9mXs9P16u3i4sOb89XyYmEkK-OiFMgKJRVXpJq2No2slJCqKxQxKmXNOsNyXiJyyqsyb6XgkjgK0XWmxRbFUfb62jvOzUCtSf0F7PUY7IBhrz1a_W_G2a3e-CtdccEqpZLg2Y0g-PSNU9SDnQz1PTry86R5mlkuFWMioU__Q3d-Di61p3mZJlooVstEPb-mTPDTFKi7LSZn-tcG6L8bkOAnd8u_Rf_MW_wEXgatdw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2641059084</pqid></control><display><type>article</type><title>Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study</title><source>Publicly Available Content Database</source><source>PubMed Central</source><creator>Zubizarreta-Macho, Álvaro ; Triduo, Martina ; Alonso Pérez-Barquero, Jorge ; Guinot Barona, Clara ; Albaladejo Martínez, Alberto</creator><creatorcontrib>Zubizarreta-Macho, Álvaro ; Triduo, Martina ; Alonso Pérez-Barquero, Jorge ; Guinot Barona, Clara ; Albaladejo Martínez, Alberto</creatorcontrib><description>The aim of this study was to construct a novel, repeatable, reproducible, and accurate measurement protocol for the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere fixed multibracket appliances. A total of 30 brackets were cemented and removed with over 30 extracted teeth embedded into three experimental models of epoxy resin. The models were scanned before and after bracket placement, bracket debonding, and polishing the remaining cement. The brackets were submitted to micro-computed tomography. The standard tessellation language digital files were aligned, segmented, and re-aligned using geomorphometric software. The digital measurement technique accuracy, repeatability, and reproducibility were analyzed using Gage R&amp;R statistical analysis. The variability attributable to the area and volume measurement techniques of the total variability of the samples was 0.70% and 0.11% for repeatability, respectively, and 0.79% and 0.01% for reproducibility, respectively. The re-alignment procedure is a repeatable, reproducible, and accurate technique that can be used to measure the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere the fixed multibracket appliance.</description><identifier>ISSN: 2077-0383</identifier><identifier>EISSN: 2077-0383</identifier><identifier>DOI: 10.3390/jcm9041098</identifier><identifier>PMID: 32290554</identifier><language>eng</language><publisher>Switzerland: MDPI AG</publisher><subject>Accuracy ; Acids ; Adhesion ; Adhesives ; Bond strength ; Cement ; Clinical medicine ; Composite materials ; Enamel ; Orthodontics ; Retention ; Teeth ; Tomography</subject><ispartof>Journal of clinical medicine, 2020-04, Vol.9 (4), p.1098</ispartof><rights>2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>2020 by the authors. 2020</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c406t-63a0594929e9bd8cb479349f59e0e6480fc0126aa2e1761d4324e2a33ffcdada3</citedby><cites>FETCH-LOGICAL-c406t-63a0594929e9bd8cb479349f59e0e6480fc0126aa2e1761d4324e2a33ffcdada3</cites><orcidid>0000-0001-9362-9702</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2641059084/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2641059084?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,25752,27923,27924,37011,37012,44589,53790,53792,74897</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/32290554$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Zubizarreta-Macho, Álvaro</creatorcontrib><creatorcontrib>Triduo, Martina</creatorcontrib><creatorcontrib>Alonso Pérez-Barquero, Jorge</creatorcontrib><creatorcontrib>Guinot Barona, Clara</creatorcontrib><creatorcontrib>Albaladejo Martínez, Alberto</creatorcontrib><title>Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study</title><title>Journal of clinical medicine</title><addtitle>J Clin Med</addtitle><description>The aim of this study was to construct a novel, repeatable, reproducible, and accurate measurement protocol for the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere fixed multibracket appliances. A total of 30 brackets were cemented and removed with over 30 extracted teeth embedded into three experimental models of epoxy resin. The models were scanned before and after bracket placement, bracket debonding, and polishing the remaining cement. The brackets were submitted to micro-computed tomography. The standard tessellation language digital files were aligned, segmented, and re-aligned using geomorphometric software. The digital measurement technique accuracy, repeatability, and reproducibility were analyzed using Gage R&amp;R statistical analysis. The variability attributable to the area and volume measurement techniques of the total variability of the samples was 0.70% and 0.11% for repeatability, respectively, and 0.79% and 0.01% for reproducibility, respectively. The re-alignment procedure is a repeatable, reproducible, and accurate technique that can be used to measure the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere the fixed multibracket appliance.</description><subject>Accuracy</subject><subject>Acids</subject><subject>Adhesion</subject><subject>Adhesives</subject><subject>Bond strength</subject><subject>Cement</subject><subject>Clinical medicine</subject><subject>Composite materials</subject><subject>Enamel</subject><subject>Orthodontics</subject><subject>Retention</subject><subject>Teeth</subject><subject>Tomography</subject><issn>2077-0383</issn><issn>2077-0383</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNpdks1u1DAQgCMEolXphQdAI3FBSAuO7fyYA9Jq20KlAgKWXq2JM9n1ktjBcSr2hXhODC2l4ItHnk-fZjyTZY9z9kIIxV7uzKCYzJmq72WHnFXVgola3L8TH2TH07Rj6dS15Hn1MDsQnCtWFPIw-_HeX1EPJ3ZjI_awJrN19ttMED18nNFF2-0hbgmWgRDQtXDp-3kg8B2saCAX4RMNaJ11m9_pU4dDEqbHJG4Bu0gBzuz3FL-b-2ibgOYrRViOY2_RGYL1lgKOezihxrs2eV7B0sG5g0sbg4fPcW73j7IHHfYTHd_cR9mXs9P16u3i4sOb89XyYmEkK-OiFMgKJRVXpJq2No2slJCqKxQxKmXNOsNyXiJyyqsyb6XgkjgK0XWmxRbFUfb62jvOzUCtSf0F7PUY7IBhrz1a_W_G2a3e-CtdccEqpZLg2Y0g-PSNU9SDnQz1PTry86R5mlkuFWMioU__Q3d-Di61p3mZJlooVstEPb-mTPDTFKi7LSZn-tcG6L8bkOAnd8u_Rf_MW_wEXgatdw</recordid><startdate>20200412</startdate><enddate>20200412</enddate><creator>Zubizarreta-Macho, Álvaro</creator><creator>Triduo, Martina</creator><creator>Alonso Pérez-Barquero, Jorge</creator><creator>Guinot Barona, Clara</creator><creator>Albaladejo Martínez, Alberto</creator><general>MDPI AG</general><general>MDPI</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7X7</scope><scope>7XB</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>K9.</scope><scope>M0S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0001-9362-9702</orcidid></search><sort><creationdate>20200412</creationdate><title>Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study</title><author>Zubizarreta-Macho, Álvaro ; Triduo, Martina ; Alonso Pérez-Barquero, Jorge ; Guinot Barona, Clara ; Albaladejo Martínez, Alberto</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c406t-63a0594929e9bd8cb479349f59e0e6480fc0126aa2e1761d4324e2a33ffcdada3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Accuracy</topic><topic>Acids</topic><topic>Adhesion</topic><topic>Adhesives</topic><topic>Bond strength</topic><topic>Cement</topic><topic>Clinical medicine</topic><topic>Composite materials</topic><topic>Enamel</topic><topic>Orthodontics</topic><topic>Retention</topic><topic>Teeth</topic><topic>Tomography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zubizarreta-Macho, Álvaro</creatorcontrib><creatorcontrib>Triduo, Martina</creatorcontrib><creatorcontrib>Alonso Pérez-Barquero, Jorge</creatorcontrib><creatorcontrib>Guinot Barona, Clara</creatorcontrib><creatorcontrib>Albaladejo Martínez, Alberto</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Health &amp; Medical Collection</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of clinical medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zubizarreta-Macho, Álvaro</au><au>Triduo, Martina</au><au>Alonso Pérez-Barquero, Jorge</au><au>Guinot Barona, Clara</au><au>Albaladejo Martínez, Alberto</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study</atitle><jtitle>Journal of clinical medicine</jtitle><addtitle>J Clin Med</addtitle><date>2020-04-12</date><risdate>2020</risdate><volume>9</volume><issue>4</issue><spage>1098</spage><pages>1098-</pages><issn>2077-0383</issn><eissn>2077-0383</eissn><abstract>The aim of this study was to construct a novel, repeatable, reproducible, and accurate measurement protocol for the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere fixed multibracket appliances. A total of 30 brackets were cemented and removed with over 30 extracted teeth embedded into three experimental models of epoxy resin. The models were scanned before and after bracket placement, bracket debonding, and polishing the remaining cement. The brackets were submitted to micro-computed tomography. The standard tessellation language digital files were aligned, segmented, and re-aligned using geomorphometric software. The digital measurement technique accuracy, repeatability, and reproducibility were analyzed using Gage R&amp;R statistical analysis. The variability attributable to the area and volume measurement techniques of the total variability of the samples was 0.70% and 0.11% for repeatability, respectively, and 0.79% and 0.01% for reproducibility, respectively. The re-alignment procedure is a repeatable, reproducible, and accurate technique that can be used to measure the area and volume of the remaining cement after removal of fixed multibracket appliances, the area and volume of remaining cement after cement removal, the area and volume of enamel removed after cement removal, and the volume of cement used to adhere the fixed multibracket appliance.</abstract><cop>Switzerland</cop><pub>MDPI AG</pub><pmid>32290554</pmid><doi>10.3390/jcm9041098</doi><orcidid>https://orcid.org/0000-0001-9362-9702</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2077-0383
ispartof Journal of clinical medicine, 2020-04, Vol.9 (4), p.1098
issn 2077-0383
2077-0383
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7230799
source Publicly Available Content Database; PubMed Central
subjects Accuracy
Acids
Adhesion
Adhesives
Bond strength
Cement
Clinical medicine
Composite materials
Enamel
Orthodontics
Retention
Teeth
Tomography
title Novel Digital Technique to Quantify the Area and Volume of Cement Remaining and Enamel Removed after Fixed Multibracket Appliance Therapy Debonding: An In Vitro Study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-12T15%3A12%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Novel%20Digital%20Technique%20to%20Quantify%20the%20Area%20and%20Volume%20of%20Cement%20Remaining%20and%20Enamel%20Removed%20after%20Fixed%20Multibracket%20Appliance%20Therapy%20Debonding:%20An%20In%20Vitro%20Study&rft.jtitle=Journal%20of%20clinical%20medicine&rft.au=Zubizarreta-Macho,%20%C3%81lvaro&rft.date=2020-04-12&rft.volume=9&rft.issue=4&rft.spage=1098&rft.pages=1098-&rft.issn=2077-0383&rft.eissn=2077-0383&rft_id=info:doi/10.3390/jcm9041098&rft_dat=%3Cproquest_pubme%3E2641059084%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c406t-63a0594929e9bd8cb479349f59e0e6480fc0126aa2e1761d4324e2a33ffcdada3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2641059084&rft_id=info:pmid/32290554&rfr_iscdi=true