Loading…
Different digital imaging techniques in dental practice
Different imaging techniques are used to pick up the signal of interest in digital sensors, including charge-coupled devices (CCD), complementary metal-oxide semiconductors (CMOS), photostimulable phosphors plates (PSP) and tuned-aperture computed tomography (TACT) Digital radiography sensors are di...
Saved in:
Published in: | Bosnian journal of basic medical sciences 2004-05, Vol.4 (2), p.37-40 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 40 |
container_issue | 2 |
container_start_page | 37 |
container_title | Bosnian journal of basic medical sciences |
container_volume | 4 |
creator | Lacević, Amela Vranić, Edina |
description | Different imaging techniques are used to pick up the signal of interest in digital sensors, including charge-coupled devices (CCD), complementary metal-oxide semiconductors (CMOS), photostimulable phosphors plates (PSP) and tuned-aperture computed tomography (TACT) Digital radiography sensors are divided into: storage phosphor plates (SPP) called photostimulable phosphor plates (PSP), silicon devices such as charge-coupled devices (CCD) or complementary metal oxide semiconductors (CMOS). Relatively new type of imaging that may hold advantage over current radiographic modalities is tuned-aperture computed tomography (TACT). |
doi_str_mv | 10.17305/bjbms.2004.3412 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7250122</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>67206256</sourcerecordid><originalsourceid>FETCH-LOGICAL-c220t-6e6867d22576f0380f04e6e16247fb3c8d10a81db58e8f584df21f079ee6f5a03</originalsourceid><addsrcrecordid>eNpVkElPwzAQhS0EoqVw54Ry4pYyntiOe0FCZZUqcYGz5Th26ipLsVMk_j3pIpbTjDRv3rz5CLmkMKV5BvymWBVNnCIAm2aM4hEZU8kgZZLi8dBziqkUQEfkLMYVgJhlkp2SEeUCZ4A4Jvm9d84G2_ZJ6Svf6zrxja58WyW9NcvWf2xsTHyblINkGK6DNr039pycOF1He3GoE_L--PA2f04Xr08v87tFahChT4UVUuQlIs-Fg0yCA2aFpQJZ7orMyJKClrQsuLTScclKh9RBPrNWOK4hm5Dbve96UzS2NEOKoGu1DkPK8KU67dX_SeuXquo-VY4cKOJgcH0wCN32l141Phpb17q13SYqkSMI5GIQwl5oQhdjsO7nCAW1o612tNWWttrSHlau_ob7XTjgzb4BxaF8fg</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>67206256</pqid></control><display><type>article</type><title>Different digital imaging techniques in dental practice</title><source>PubMed Central</source><source>EZB Electronic Journals Library</source><creator>Lacević, Amela ; Vranić, Edina</creator><creatorcontrib>Lacević, Amela ; Vranić, Edina</creatorcontrib><description>Different imaging techniques are used to pick up the signal of interest in digital sensors, including charge-coupled devices (CCD), complementary metal-oxide semiconductors (CMOS), photostimulable phosphors plates (PSP) and tuned-aperture computed tomography (TACT) Digital radiography sensors are divided into: storage phosphor plates (SPP) called photostimulable phosphor plates (PSP), silicon devices such as charge-coupled devices (CCD) or complementary metal oxide semiconductors (CMOS). Relatively new type of imaging that may hold advantage over current radiographic modalities is tuned-aperture computed tomography (TACT).</description><identifier>ISSN: 1512-8601</identifier><identifier>EISSN: 1840-4812</identifier><identifier>DOI: 10.17305/bjbms.2004.3412</identifier><identifier>PMID: 15629022</identifier><language>eng</language><publisher>Bosnia and Herzegovina: Association of Basic Medical Sciences of Federation of Bosnia and Herzegovina</publisher><subject>Humans ; Image Processing, Computer-Assisted ; Radiography, Dental, Digital - methods ; Tomography, X-Ray Computed</subject><ispartof>Bosnian journal of basic medical sciences, 2004-05, Vol.4 (2), p.37-40</ispartof><rights>Copyright: © 2004 ABMSFBIH 2004</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7250122/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7250122/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,27923,27924,53790,53792</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/15629022$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Lacević, Amela</creatorcontrib><creatorcontrib>Vranić, Edina</creatorcontrib><title>Different digital imaging techniques in dental practice</title><title>Bosnian journal of basic medical sciences</title><addtitle>Bosn J Basic Med Sci</addtitle><description>Different imaging techniques are used to pick up the signal of interest in digital sensors, including charge-coupled devices (CCD), complementary metal-oxide semiconductors (CMOS), photostimulable phosphors plates (PSP) and tuned-aperture computed tomography (TACT) Digital radiography sensors are divided into: storage phosphor plates (SPP) called photostimulable phosphor plates (PSP), silicon devices such as charge-coupled devices (CCD) or complementary metal oxide semiconductors (CMOS). Relatively new type of imaging that may hold advantage over current radiographic modalities is tuned-aperture computed tomography (TACT).</description><subject>Humans</subject><subject>Image Processing, Computer-Assisted</subject><subject>Radiography, Dental, Digital - methods</subject><subject>Tomography, X-Ray Computed</subject><issn>1512-8601</issn><issn>1840-4812</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2004</creationdate><recordtype>article</recordtype><recordid>eNpVkElPwzAQhS0EoqVw54Ry4pYyntiOe0FCZZUqcYGz5Th26ipLsVMk_j3pIpbTjDRv3rz5CLmkMKV5BvymWBVNnCIAm2aM4hEZU8kgZZLi8dBziqkUQEfkLMYVgJhlkp2SEeUCZ4A4Jvm9d84G2_ZJ6Svf6zrxja58WyW9NcvWf2xsTHyblINkGK6DNr039pycOF1He3GoE_L--PA2f04Xr08v87tFahChT4UVUuQlIs-Fg0yCA2aFpQJZ7orMyJKClrQsuLTScclKh9RBPrNWOK4hm5Dbve96UzS2NEOKoGu1DkPK8KU67dX_SeuXquo-VY4cKOJgcH0wCN32l141Phpb17q13SYqkSMI5GIQwl5oQhdjsO7nCAW1o612tNWWttrSHlau_ob7XTjgzb4BxaF8fg</recordid><startdate>20040501</startdate><enddate>20040501</enddate><creator>Lacević, Amela</creator><creator>Vranić, Edina</creator><general>Association of Basic Medical Sciences of Federation of Bosnia and Herzegovina</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>20040501</creationdate><title>Different digital imaging techniques in dental practice</title><author>Lacević, Amela ; Vranić, Edina</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c220t-6e6867d22576f0380f04e6e16247fb3c8d10a81db58e8f584df21f079ee6f5a03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2004</creationdate><topic>Humans</topic><topic>Image Processing, Computer-Assisted</topic><topic>Radiography, Dental, Digital - methods</topic><topic>Tomography, X-Ray Computed</topic><toplevel>online_resources</toplevel><creatorcontrib>Lacević, Amela</creatorcontrib><creatorcontrib>Vranić, Edina</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Bosnian journal of basic medical sciences</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lacević, Amela</au><au>Vranić, Edina</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Different digital imaging techniques in dental practice</atitle><jtitle>Bosnian journal of basic medical sciences</jtitle><addtitle>Bosn J Basic Med Sci</addtitle><date>2004-05-01</date><risdate>2004</risdate><volume>4</volume><issue>2</issue><spage>37</spage><epage>40</epage><pages>37-40</pages><issn>1512-8601</issn><eissn>1840-4812</eissn><abstract>Different imaging techniques are used to pick up the signal of interest in digital sensors, including charge-coupled devices (CCD), complementary metal-oxide semiconductors (CMOS), photostimulable phosphors plates (PSP) and tuned-aperture computed tomography (TACT) Digital radiography sensors are divided into: storage phosphor plates (SPP) called photostimulable phosphor plates (PSP), silicon devices such as charge-coupled devices (CCD) or complementary metal oxide semiconductors (CMOS). Relatively new type of imaging that may hold advantage over current radiographic modalities is tuned-aperture computed tomography (TACT).</abstract><cop>Bosnia and Herzegovina</cop><pub>Association of Basic Medical Sciences of Federation of Bosnia and Herzegovina</pub><pmid>15629022</pmid><doi>10.17305/bjbms.2004.3412</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1512-8601 |
ispartof | Bosnian journal of basic medical sciences, 2004-05, Vol.4 (2), p.37-40 |
issn | 1512-8601 1840-4812 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7250122 |
source | PubMed Central; EZB Electronic Journals Library |
subjects | Humans Image Processing, Computer-Assisted Radiography, Dental, Digital - methods Tomography, X-Ray Computed |
title | Different digital imaging techniques in dental practice |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-08T21%3A00%3A24IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Different%20digital%20imaging%20techniques%20in%20dental%20practice&rft.jtitle=Bosnian%20journal%20of%20basic%20medical%20sciences&rft.au=Lacevi%C4%87,%20Amela&rft.date=2004-05-01&rft.volume=4&rft.issue=2&rft.spage=37&rft.epage=40&rft.pages=37-40&rft.issn=1512-8601&rft.eissn=1840-4812&rft_id=info:doi/10.17305/bjbms.2004.3412&rft_dat=%3Cproquest_pubme%3E67206256%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c220t-6e6867d22576f0380f04e6e16247fb3c8d10a81db58e8f584df21f079ee6f5a03%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=67206256&rft_id=info:pmid/15629022&rfr_iscdi=true |