Loading…

Wear Morphology on the Surfaces of CoCrMo Unicompartmental Knee Joint Endoprostheses as Elements of Metal-Metal Friction Nodes

The article assesses the strength and structural parameters of load-bearing layers of metal biobearings made of CoCrMo alloy. The research material consisted of unicompartmental knee joint endoprostheses used in the human body, removed due to excessive wear. No patient participated in the examinatio...

Full description

Saved in:
Bibliographic Details
Published in:Materials 2020-06, Vol.13 (12), p.2689
Main Authors: Szarek, Arkadiusz, Stradomski, Grzegorz, Łukomska-Szarek, Justyna, Rydz, Dariusz, Wolański, Wojciech, Joszko, Kamil
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The article assesses the strength and structural parameters of load-bearing layers of metal biobearings made of CoCrMo alloy. The research material consisted of unicompartmental knee joint endoprostheses used in the human body, removed due to excessive wear. No patient participated in the examinations. The endoprostheses used as research material underwent the liquidation procedures in the hospital, which has all necessary permissions and certifications to perform endoprosthetic procedures. Endoprostheses selected for the examinations had been used for 6 to 12 years at similar load conditions as declared by the patients, i.e., body weight of F = 835 N, declared activity expressed as the number of load cycles up to 100 thousand/year, and no artificial joint infections. To assess the homogeneity of the research material, the analysis of chemical composition using a Joel scanning electron microscope with EDS (Energy-dispersive X-ray spectroscopy) was made to exclude endoprostheses with various alloying additives. Microscopic examinations were performed using the Phenom XL microscope, while the wear surface was examined using a Keyence VHX-900F microscope. Several experimental tests were also carried out on load-bearing surfaces to assess changes in strength parameters of the base material after a known life cycle and load conditions. Material hardness using the Vickers method, yield point, critical value of stress intensity coefficient, and the coefficient of friction µ were evaluated. The examinations allowed for the systematization of wear in the knee and femoral components of unicompartmental hip endoprostheses. The statistical evaluation of the number and costs of hip joint replacement surgeries in Poland was also made.
ISSN:1996-1944
1996-1944
DOI:10.3390/ma13122689