Loading…

Endograft Conformability in Fenestrated Endovascular Aneurysm Repair for Complex Abdominal Aortic Aneurysms

Purpose: To compare the impact of 2 commercially available custom-made fenestrated endografts on patient anatomy. Materials and Methods: The records of 234 patients who underwent fenestrated endovascular aneurysm repair for abdominal aortic aneurysm from March 2002 to July 2016 in 2 hospitals were s...

Full description

Saved in:
Bibliographic Details
Published in:Journal of endovascular therapy 2020-10, Vol.27 (5), p.848-856
Main Authors: de Niet, Arne, Donselaar, Esmé J., Holewijn, Suzanne, Tielliu, Ignace F. J., Lardenoije, Jan Willem H. P., Zeebregts, Clark J., Reijnen, Michel M. P. J.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c411t-543bcb959dcf73e55e93f5bffd754355c233b40f9f6ff404203ae58e6da41fa23
cites cdi_FETCH-LOGICAL-c411t-543bcb959dcf73e55e93f5bffd754355c233b40f9f6ff404203ae58e6da41fa23
container_end_page 856
container_issue 5
container_start_page 848
container_title Journal of endovascular therapy
container_volume 27
creator de Niet, Arne
Donselaar, Esmé J.
Holewijn, Suzanne
Tielliu, Ignace F. J.
Lardenoije, Jan Willem H. P.
Zeebregts, Clark J.
Reijnen, Michel M. P. J.
description Purpose: To compare the impact of 2 commercially available custom-made fenestrated endografts on patient anatomy. Materials and Methods: The records of 234 patients who underwent fenestrated endovascular aneurysm repair for abdominal aortic aneurysm from March 2002 to July 2016 in 2 hospitals were screened to identify those who had pre- and postoperative computed tomography angiography assessments with a slice thickness of ≤2 mm. The search identified 145 patients for further analysis: 110 patients (mean age 72.4±7.1 years; 94 men) who had been treated with the Zenith Fenestrated (ZF) endograft and 35 patients (mean age 72.3±7.3 years; 30 men) treated with the Fenestrated Anaconda (FA) endograft. Measurements included aortic diameters at the level of the superior mesenteric artery (SMA) and renal arteries, target vessel angles, target vessel clock positions, and the target vessel tortuosity index. Variables were tested for inter- and intraobserver agreement. Results: There was a good agreement between observers in all tested variables. The native anatomy changed in both groups after endograft implantation. In the ZF group, changes were seen in the angles of the celiac artery (p=0.012), SMA (p=0.022), left renal artery (LRA) (p
doi_str_mv 10.1177/1526602820936185
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7536524</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sage_id>10.1177_1526602820936185</sage_id><sourcerecordid>2415831989</sourcerecordid><originalsourceid>FETCH-LOGICAL-c411t-543bcb959dcf73e55e93f5bffd754355c233b40f9f6ff404203ae58e6da41fa23</originalsourceid><addsrcrecordid>eNp1kc1r3DAQxUVpaNIk9x517MWtvka2L4VlSdpCoFCas5Dl0VapLW0lO2T_-2rZEGihpxl4v_eGmSHkHWcfOG_bjxyE1kx0gvVS8w5ekQsOChoOwF4fe6Gbo35O3pbywJjggvM35FwK0G2v1QX5dRPHtMvWL3Sbok95tkOYwnKgIdJbjFiWbBcc6ZF7tMWtk810E3HNhzLT77i3IdPqq_Z5P-ET3QxjmkO0E92kvAT3ApcrcubtVPD6uV6S-9ubH9svzd23z1-3m7vGKc6XBpQc3NBDPzrfSgTAXnoYvB_bKgE4IeWgmO-99l4xJZi0CB3q0SrurZCX5NMpd78OM44OY91hMvscZpsPJtlg_lZi-Gl26dG0IDUIVQPePwfk9HutJzBzKA6nyUZMazFCcegk77u-ouyEupxKyehfxnBmjj8y__6oWpqTpdgdmoe05nqs8n_-DxyaknE</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2415831989</pqid></control><display><type>article</type><title>Endograft Conformability in Fenestrated Endovascular Aneurysm Repair for Complex Abdominal Aortic Aneurysms</title><source>SAGE</source><creator>de Niet, Arne ; Donselaar, Esmé J. ; Holewijn, Suzanne ; Tielliu, Ignace F. J. ; Lardenoije, Jan Willem H. P. ; Zeebregts, Clark J. ; Reijnen, Michel M. P. J.</creator><creatorcontrib>de Niet, Arne ; Donselaar, Esmé J. ; Holewijn, Suzanne ; Tielliu, Ignace F. J. ; Lardenoije, Jan Willem H. P. ; Zeebregts, Clark J. ; Reijnen, Michel M. P. J.</creatorcontrib><description><![CDATA[Purpose: To compare the impact of 2 commercially available custom-made fenestrated endografts on patient anatomy. Materials and Methods: The records of 234 patients who underwent fenestrated endovascular aneurysm repair for abdominal aortic aneurysm from March 2002 to July 2016 in 2 hospitals were screened to identify those who had pre- and postoperative computed tomography angiography assessments with a slice thickness of ≤2 mm. The search identified 145 patients for further analysis: 110 patients (mean age 72.4±7.1 years; 94 men) who had been treated with the Zenith Fenestrated (ZF) endograft and 35 patients (mean age 72.3±7.3 years; 30 men) treated with the Fenestrated Anaconda (FA) endograft. Measurements included aortic diameters at the level of the superior mesenteric artery (SMA) and renal arteries, target vessel angles, target vessel clock positions, and the target vessel tortuosity index. Variables were tested for inter- and intraobserver agreement. Results: There was a good agreement between observers in all tested variables. The native anatomy changed in both groups after endograft implantation. In the ZF group, changes were seen in the angles of the celiac artery (p=0.012), SMA (p=0.022), left renal artery (LRA) (p<0.001), and the right renal artery (RRA) (p<0.001); the aortic diameter at the SMA level (p<0.001); and the LRA (p<0.001) and RRA (p<0.001) clock positions. In the FA group, changes were seen in the angles of the LRA (p=0.001) and RRA (p<0.001) and in the SMA tortuosity index (p=0.044). Between group differences in changes were seen for the aortic diameters at the SMA and renal artery levels (p<0.001 for both) and the LRA clock position (p=0.019). Conclusion: Both custom-made fenestrated endografts altered vascular anatomy. The data suggest a higher conformability of the Fenestrated Anaconda endograft compared with the Zenith Fenestrated.]]></description><identifier>ISSN: 1526-6028</identifier><identifier>EISSN: 1545-1550</identifier><identifier>DOI: 10.1177/1526602820936185</identifier><identifier>PMID: 32567964</identifier><language>eng</language><publisher>Los Angeles, CA: SAGE Publications</publisher><subject>Endovascular Aneurysm Repair</subject><ispartof>Journal of endovascular therapy, 2020-10, Vol.27 (5), p.848-856</ispartof><rights>The Author(s) 2020</rights><rights>The Author(s) 2020 2020 SAGE Publications</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c411t-543bcb959dcf73e55e93f5bffd754355c233b40f9f6ff404203ae58e6da41fa23</citedby><cites>FETCH-LOGICAL-c411t-543bcb959dcf73e55e93f5bffd754355c233b40f9f6ff404203ae58e6da41fa23</cites><orcidid>0000-0001-8830-863X ; 0000-0002-5021-1768</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27903,27904,79111</link.rule.ids></links><search><creatorcontrib>de Niet, Arne</creatorcontrib><creatorcontrib>Donselaar, Esmé J.</creatorcontrib><creatorcontrib>Holewijn, Suzanne</creatorcontrib><creatorcontrib>Tielliu, Ignace F. J.</creatorcontrib><creatorcontrib>Lardenoije, Jan Willem H. P.</creatorcontrib><creatorcontrib>Zeebregts, Clark J.</creatorcontrib><creatorcontrib>Reijnen, Michel M. P. J.</creatorcontrib><title>Endograft Conformability in Fenestrated Endovascular Aneurysm Repair for Complex Abdominal Aortic Aneurysms</title><title>Journal of endovascular therapy</title><description><![CDATA[Purpose: To compare the impact of 2 commercially available custom-made fenestrated endografts on patient anatomy. Materials and Methods: The records of 234 patients who underwent fenestrated endovascular aneurysm repair for abdominal aortic aneurysm from March 2002 to July 2016 in 2 hospitals were screened to identify those who had pre- and postoperative computed tomography angiography assessments with a slice thickness of ≤2 mm. The search identified 145 patients for further analysis: 110 patients (mean age 72.4±7.1 years; 94 men) who had been treated with the Zenith Fenestrated (ZF) endograft and 35 patients (mean age 72.3±7.3 years; 30 men) treated with the Fenestrated Anaconda (FA) endograft. Measurements included aortic diameters at the level of the superior mesenteric artery (SMA) and renal arteries, target vessel angles, target vessel clock positions, and the target vessel tortuosity index. Variables were tested for inter- and intraobserver agreement. Results: There was a good agreement between observers in all tested variables. The native anatomy changed in both groups after endograft implantation. In the ZF group, changes were seen in the angles of the celiac artery (p=0.012), SMA (p=0.022), left renal artery (LRA) (p<0.001), and the right renal artery (RRA) (p<0.001); the aortic diameter at the SMA level (p<0.001); and the LRA (p<0.001) and RRA (p<0.001) clock positions. In the FA group, changes were seen in the angles of the LRA (p=0.001) and RRA (p<0.001) and in the SMA tortuosity index (p=0.044). Between group differences in changes were seen for the aortic diameters at the SMA and renal artery levels (p<0.001 for both) and the LRA clock position (p=0.019). Conclusion: Both custom-made fenestrated endografts altered vascular anatomy. The data suggest a higher conformability of the Fenestrated Anaconda endograft compared with the Zenith Fenestrated.]]></description><subject>Endovascular Aneurysm Repair</subject><issn>1526-6028</issn><issn>1545-1550</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>AFRWT</sourceid><recordid>eNp1kc1r3DAQxUVpaNIk9x517MWtvka2L4VlSdpCoFCas5Dl0VapLW0lO2T_-2rZEGihpxl4v_eGmSHkHWcfOG_bjxyE1kx0gvVS8w5ekQsOChoOwF4fe6Gbo35O3pbywJjggvM35FwK0G2v1QX5dRPHtMvWL3Sbok95tkOYwnKgIdJbjFiWbBcc6ZF7tMWtk810E3HNhzLT77i3IdPqq_Z5P-ET3QxjmkO0E92kvAT3ApcrcubtVPD6uV6S-9ubH9svzd23z1-3m7vGKc6XBpQc3NBDPzrfSgTAXnoYvB_bKgE4IeWgmO-99l4xJZi0CB3q0SrurZCX5NMpd78OM44OY91hMvscZpsPJtlg_lZi-Gl26dG0IDUIVQPePwfk9HutJzBzKA6nyUZMazFCcegk77u-ouyEupxKyehfxnBmjj8y__6oWpqTpdgdmoe05nqs8n_-DxyaknE</recordid><startdate>20201001</startdate><enddate>20201001</enddate><creator>de Niet, Arne</creator><creator>Donselaar, Esmé J.</creator><creator>Holewijn, Suzanne</creator><creator>Tielliu, Ignace F. J.</creator><creator>Lardenoije, Jan Willem H. P.</creator><creator>Zeebregts, Clark J.</creator><creator>Reijnen, Michel M. P. J.</creator><general>SAGE Publications</general><scope>AFRWT</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0001-8830-863X</orcidid><orcidid>https://orcid.org/0000-0002-5021-1768</orcidid></search><sort><creationdate>20201001</creationdate><title>Endograft Conformability in Fenestrated Endovascular Aneurysm Repair for Complex Abdominal Aortic Aneurysms</title><author>de Niet, Arne ; Donselaar, Esmé J. ; Holewijn, Suzanne ; Tielliu, Ignace F. J. ; Lardenoije, Jan Willem H. P. ; Zeebregts, Clark J. ; Reijnen, Michel M. P. J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c411t-543bcb959dcf73e55e93f5bffd754355c233b40f9f6ff404203ae58e6da41fa23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Endovascular Aneurysm Repair</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>de Niet, Arne</creatorcontrib><creatorcontrib>Donselaar, Esmé J.</creatorcontrib><creatorcontrib>Holewijn, Suzanne</creatorcontrib><creatorcontrib>Tielliu, Ignace F. J.</creatorcontrib><creatorcontrib>Lardenoije, Jan Willem H. P.</creatorcontrib><creatorcontrib>Zeebregts, Clark J.</creatorcontrib><creatorcontrib>Reijnen, Michel M. P. J.</creatorcontrib><collection>Sage Journals GOLD Open Access 2024</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of endovascular therapy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>de Niet, Arne</au><au>Donselaar, Esmé J.</au><au>Holewijn, Suzanne</au><au>Tielliu, Ignace F. J.</au><au>Lardenoije, Jan Willem H. P.</au><au>Zeebregts, Clark J.</au><au>Reijnen, Michel M. P. J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Endograft Conformability in Fenestrated Endovascular Aneurysm Repair for Complex Abdominal Aortic Aneurysms</atitle><jtitle>Journal of endovascular therapy</jtitle><date>2020-10-01</date><risdate>2020</risdate><volume>27</volume><issue>5</issue><spage>848</spage><epage>856</epage><pages>848-856</pages><issn>1526-6028</issn><eissn>1545-1550</eissn><abstract><![CDATA[Purpose: To compare the impact of 2 commercially available custom-made fenestrated endografts on patient anatomy. Materials and Methods: The records of 234 patients who underwent fenestrated endovascular aneurysm repair for abdominal aortic aneurysm from March 2002 to July 2016 in 2 hospitals were screened to identify those who had pre- and postoperative computed tomography angiography assessments with a slice thickness of ≤2 mm. The search identified 145 patients for further analysis: 110 patients (mean age 72.4±7.1 years; 94 men) who had been treated with the Zenith Fenestrated (ZF) endograft and 35 patients (mean age 72.3±7.3 years; 30 men) treated with the Fenestrated Anaconda (FA) endograft. Measurements included aortic diameters at the level of the superior mesenteric artery (SMA) and renal arteries, target vessel angles, target vessel clock positions, and the target vessel tortuosity index. Variables were tested for inter- and intraobserver agreement. Results: There was a good agreement between observers in all tested variables. The native anatomy changed in both groups after endograft implantation. In the ZF group, changes were seen in the angles of the celiac artery (p=0.012), SMA (p=0.022), left renal artery (LRA) (p<0.001), and the right renal artery (RRA) (p<0.001); the aortic diameter at the SMA level (p<0.001); and the LRA (p<0.001) and RRA (p<0.001) clock positions. In the FA group, changes were seen in the angles of the LRA (p=0.001) and RRA (p<0.001) and in the SMA tortuosity index (p=0.044). Between group differences in changes were seen for the aortic diameters at the SMA and renal artery levels (p<0.001 for both) and the LRA clock position (p=0.019). Conclusion: Both custom-made fenestrated endografts altered vascular anatomy. The data suggest a higher conformability of the Fenestrated Anaconda endograft compared with the Zenith Fenestrated.]]></abstract><cop>Los Angeles, CA</cop><pub>SAGE Publications</pub><pmid>32567964</pmid><doi>10.1177/1526602820936185</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0001-8830-863X</orcidid><orcidid>https://orcid.org/0000-0002-5021-1768</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1526-6028
ispartof Journal of endovascular therapy, 2020-10, Vol.27 (5), p.848-856
issn 1526-6028
1545-1550
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7536524
source SAGE
subjects Endovascular Aneurysm Repair
title Endograft Conformability in Fenestrated Endovascular Aneurysm Repair for Complex Abdominal Aortic Aneurysms
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T17%3A08%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Endograft%20Conformability%20in%20Fenestrated%20Endovascular%20Aneurysm%20Repair%20for%20Complex%20Abdominal%20Aortic%20Aneurysms&rft.jtitle=Journal%20of%20endovascular%20therapy&rft.au=de%20Niet,%20Arne&rft.date=2020-10-01&rft.volume=27&rft.issue=5&rft.spage=848&rft.epage=856&rft.pages=848-856&rft.issn=1526-6028&rft.eissn=1545-1550&rft_id=info:doi/10.1177/1526602820936185&rft_dat=%3Cproquest_pubme%3E2415831989%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c411t-543bcb959dcf73e55e93f5bffd754355c233b40f9f6ff404203ae58e6da41fa23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2415831989&rft_id=info:pmid/32567964&rft_sage_id=10.1177_1526602820936185&rfr_iscdi=true