Influence of the Chelating Solutions in the Resistance of Glass Fiber Posts to the Root Dentin
Abstract Objective This study aimed to evaluate the influence of chelating agents (EDTA, citric acid and Tetraclean) on glass fiber posts adhesion to root dentin. Materials and Methods Forty mandibular premolars single canals, with complete apical root, straight, circular cross sections were selec...
Saved in:
Published in: | European journal of dentistry 2020-10, Vol.14 (4), p.584-589 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c3201-4e95d1a827df1923ab4b99fdce0845cb23bba769be830675db9e7309e11762b33 |
---|---|
cites | cdi_FETCH-LOGICAL-c3201-4e95d1a827df1923ab4b99fdce0845cb23bba769be830675db9e7309e11762b33 |
container_end_page | 589 |
container_issue | 4 |
container_start_page | 584 |
container_title | European journal of dentistry |
container_volume | 14 |
creator | Marques, Eduardo Fernandes Marceliano-Alves, Marília Fagury Videira Pelegrine, Rina Andrea Pinheiro, Sérgio Luiz Bueno, Carlos Eduardo Da Silveira |
description | Abstract
Objective
This study aimed to evaluate the influence of chelating agents (EDTA, citric acid and Tetraclean) on glass fiber posts adhesion to root dentin.
Materials and Methods
Forty mandibular premolars single canals, with complete apical root, straight, circular cross sections were selected, accessed and had the cervical third prepared with Gates-Glidden drills, then included in resin, instrumented with ProTaper Universal and the root canal obturation was carried out. After, the samples were randomly divided into 4 groups (n = 10) to test the final irrigation solutions: G1:17% EDTA; G2:10% citric acid; G3: Tetraclean and G4: saline solution (control). After 30 days of storage (36.5° C and 100% humidity), the post preparation was performed leaving 4 mm of apical endodontic filling. Then, a fiber-glass post previously selected was coated with ED Primer adhesive system and resin sealer Panavia, installed and stored for 24 hours at 37°C. The samples were subjected to a tensile test with a constant speed of 1 mm/min with 2000 Kgf. The results were analyzed with the ANOVA test.
Results
The statistical analyzes indicated no significant differences between the groups (p > 0.05).
Conclusion
The type of chelating agent used in the final irrigation of the endodontic treatment did not influence the tensile strength of the fixation system used to sealer the glass fiber posts to the intracanal dentin. |
doi_str_mv | 10.1055/s-0040-1714761 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7541334</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2436394491</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3201-4e95d1a827df1923ab4b99fdce0845cb23bba769be830675db9e7309e11762b33</originalsourceid><addsrcrecordid>eNp1kc1LAzEQxYMoflSvnnP0sjXZZJPmIkj9KgiKH1dDsp21kW1Sd7KC_72rLYIHTzPwfu8NzCPkmLMxZ1V1igVjkhVcc6kV3yL7XLCq0FLJ7d-9UnvkAPGNMSWUMbtkT5STkkkt9snLLDZtD7EGmhqaF0CnC2hdDvGVPqa2zyFFpCH-SA-AAbPbwNetQ6RXwUNH7xNmpDmtsZQyvYA4hBySnca1CEebOSLPV5dP05vi9u56Nj2_LWpRMl5IMNWcu0mp5w03pXBeemOaeQ1sIqval8J7p5XxMBFM6WruDWjBDHCuVemFGJGzde6q90sYfDF3rrWrLixd92mTC_avEsPCvqYPqyvJhZBDwMkmoEvvPWC2y4A1tK2LkHq0pRRKGCkNH9DxGq27hNhB83uGM_tdikX7XYrdlDIYirUhLwIswb6lvovDN_7jvwB4NYwo</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2436394491</pqid></control><display><type>article</type><title>Influence of the Chelating Solutions in the Resistance of Glass Fiber Posts to the Root Dentin</title><source>PubMed Central Free</source><source>Thieme Connect Journals Open Access</source><creator>Marques, Eduardo Fernandes ; Marceliano-Alves, Marília Fagury Videira ; Pelegrine, Rina Andrea ; Pinheiro, Sérgio Luiz ; Bueno, Carlos Eduardo Da Silveira</creator><creatorcontrib>Marques, Eduardo Fernandes ; Marceliano-Alves, Marília Fagury Videira ; Pelegrine, Rina Andrea ; Pinheiro, Sérgio Luiz ; Bueno, Carlos Eduardo Da Silveira</creatorcontrib><description>Abstract
Objective
This study aimed to evaluate the influence of chelating agents (EDTA, citric acid and Tetraclean) on glass fiber posts adhesion to root dentin.
Materials and Methods
Forty mandibular premolars single canals, with complete apical root, straight, circular cross sections were selected, accessed and had the cervical third prepared with Gates-Glidden drills, then included in resin, instrumented with ProTaper Universal and the root canal obturation was carried out. After, the samples were randomly divided into 4 groups (n = 10) to test the final irrigation solutions: G1:17% EDTA; G2:10% citric acid; G3: Tetraclean and G4: saline solution (control). After 30 days of storage (36.5° C and 100% humidity), the post preparation was performed leaving 4 mm of apical endodontic filling. Then, a fiber-glass post previously selected was coated with ED Primer adhesive system and resin sealer Panavia, installed and stored for 24 hours at 37°C. The samples were subjected to a tensile test with a constant speed of 1 mm/min with 2000 Kgf. The results were analyzed with the ANOVA test.
Results
The statistical analyzes indicated no significant differences between the groups (p > 0.05).
Conclusion
The type of chelating agent used in the final irrigation of the endodontic treatment did not influence the tensile strength of the fixation system used to sealer the glass fiber posts to the intracanal dentin.</description><identifier>ISSN: 1305-7456</identifier><identifier>EISSN: 1305-7464</identifier><identifier>DOI: 10.1055/s-0040-1714761</identifier><identifier>PMID: 32820473</identifier><language>eng</language><publisher>A-12, Second Floor, Sector -2, NOIDA -201301, India: Thieme Medical and Scientific Publishers Private Ltd</publisher><subject>Original ; Original Article</subject><ispartof>European journal of dentistry, 2020-10, Vol.14 (4), p.584-589</ispartof><rights>Dental Investigation Society</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3201-4e95d1a827df1923ab4b99fdce0845cb23bba769be830675db9e7309e11762b33</citedby><cites>FETCH-LOGICAL-c3201-4e95d1a827df1923ab4b99fdce0845cb23bba769be830675db9e7309e11762b33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7541334/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7541334/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,20891,27924,27925,53791,53793,54587,54615</link.rule.ids></links><search><creatorcontrib>Marques, Eduardo Fernandes</creatorcontrib><creatorcontrib>Marceliano-Alves, Marília Fagury Videira</creatorcontrib><creatorcontrib>Pelegrine, Rina Andrea</creatorcontrib><creatorcontrib>Pinheiro, Sérgio Luiz</creatorcontrib><creatorcontrib>Bueno, Carlos Eduardo Da Silveira</creatorcontrib><title>Influence of the Chelating Solutions in the Resistance of Glass Fiber Posts to the Root Dentin</title><title>European journal of dentistry</title><addtitle>Eur J Dent</addtitle><description>Abstract
Objective
This study aimed to evaluate the influence of chelating agents (EDTA, citric acid and Tetraclean) on glass fiber posts adhesion to root dentin.
Materials and Methods
Forty mandibular premolars single canals, with complete apical root, straight, circular cross sections were selected, accessed and had the cervical third prepared with Gates-Glidden drills, then included in resin, instrumented with ProTaper Universal and the root canal obturation was carried out. After, the samples were randomly divided into 4 groups (n = 10) to test the final irrigation solutions: G1:17% EDTA; G2:10% citric acid; G3: Tetraclean and G4: saline solution (control). After 30 days of storage (36.5° C and 100% humidity), the post preparation was performed leaving 4 mm of apical endodontic filling. Then, a fiber-glass post previously selected was coated with ED Primer adhesive system and resin sealer Panavia, installed and stored for 24 hours at 37°C. The samples were subjected to a tensile test with a constant speed of 1 mm/min with 2000 Kgf. The results were analyzed with the ANOVA test.
Results
The statistical analyzes indicated no significant differences between the groups (p > 0.05).
Conclusion
The type of chelating agent used in the final irrigation of the endodontic treatment did not influence the tensile strength of the fixation system used to sealer the glass fiber posts to the intracanal dentin.</description><subject>Original</subject><subject>Original Article</subject><issn>1305-7456</issn><issn>1305-7464</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>0U6</sourceid><recordid>eNp1kc1LAzEQxYMoflSvnnP0sjXZZJPmIkj9KgiKH1dDsp21kW1Sd7KC_72rLYIHTzPwfu8NzCPkmLMxZ1V1igVjkhVcc6kV3yL7XLCq0FLJ7d-9UnvkAPGNMSWUMbtkT5STkkkt9snLLDZtD7EGmhqaF0CnC2hdDvGVPqa2zyFFpCH-SA-AAbPbwNetQ6RXwUNH7xNmpDmtsZQyvYA4hBySnca1CEebOSLPV5dP05vi9u56Nj2_LWpRMl5IMNWcu0mp5w03pXBeemOaeQ1sIqval8J7p5XxMBFM6WruDWjBDHCuVemFGJGzde6q90sYfDF3rrWrLixd92mTC_avEsPCvqYPqyvJhZBDwMkmoEvvPWC2y4A1tK2LkHq0pRRKGCkNH9DxGq27hNhB83uGM_tdikX7XYrdlDIYirUhLwIswb6lvovDN_7jvwB4NYwo</recordid><startdate>202010</startdate><enddate>202010</enddate><creator>Marques, Eduardo Fernandes</creator><creator>Marceliano-Alves, Marília Fagury Videira</creator><creator>Pelegrine, Rina Andrea</creator><creator>Pinheiro, Sérgio Luiz</creator><creator>Bueno, Carlos Eduardo Da Silveira</creator><general>Thieme Medical and Scientific Publishers Private Ltd</general><scope>0U6</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>202010</creationdate><title>Influence of the Chelating Solutions in the Resistance of Glass Fiber Posts to the Root Dentin</title><author>Marques, Eduardo Fernandes ; Marceliano-Alves, Marília Fagury Videira ; Pelegrine, Rina Andrea ; Pinheiro, Sérgio Luiz ; Bueno, Carlos Eduardo Da Silveira</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3201-4e95d1a827df1923ab4b99fdce0845cb23bba769be830675db9e7309e11762b33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Original</topic><topic>Original Article</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Marques, Eduardo Fernandes</creatorcontrib><creatorcontrib>Marceliano-Alves, Marília Fagury Videira</creatorcontrib><creatorcontrib>Pelegrine, Rina Andrea</creatorcontrib><creatorcontrib>Pinheiro, Sérgio Luiz</creatorcontrib><creatorcontrib>Bueno, Carlos Eduardo Da Silveira</creatorcontrib><collection>Thieme Connect Journals Open Access</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>European journal of dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Marques, Eduardo Fernandes</au><au>Marceliano-Alves, Marília Fagury Videira</au><au>Pelegrine, Rina Andrea</au><au>Pinheiro, Sérgio Luiz</au><au>Bueno, Carlos Eduardo Da Silveira</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of the Chelating Solutions in the Resistance of Glass Fiber Posts to the Root Dentin</atitle><jtitle>European journal of dentistry</jtitle><addtitle>Eur J Dent</addtitle><date>2020-10</date><risdate>2020</risdate><volume>14</volume><issue>4</issue><spage>584</spage><epage>589</epage><pages>584-589</pages><issn>1305-7456</issn><eissn>1305-7464</eissn><abstract>Abstract
Objective
This study aimed to evaluate the influence of chelating agents (EDTA, citric acid and Tetraclean) on glass fiber posts adhesion to root dentin.
Materials and Methods
Forty mandibular premolars single canals, with complete apical root, straight, circular cross sections were selected, accessed and had the cervical third prepared with Gates-Glidden drills, then included in resin, instrumented with ProTaper Universal and the root canal obturation was carried out. After, the samples were randomly divided into 4 groups (n = 10) to test the final irrigation solutions: G1:17% EDTA; G2:10% citric acid; G3: Tetraclean and G4: saline solution (control). After 30 days of storage (36.5° C and 100% humidity), the post preparation was performed leaving 4 mm of apical endodontic filling. Then, a fiber-glass post previously selected was coated with ED Primer adhesive system and resin sealer Panavia, installed and stored for 24 hours at 37°C. The samples were subjected to a tensile test with a constant speed of 1 mm/min with 2000 Kgf. The results were analyzed with the ANOVA test.
Results
The statistical analyzes indicated no significant differences between the groups (p > 0.05).
Conclusion
The type of chelating agent used in the final irrigation of the endodontic treatment did not influence the tensile strength of the fixation system used to sealer the glass fiber posts to the intracanal dentin.</abstract><cop>A-12, Second Floor, Sector -2, NOIDA -201301, India</cop><pub>Thieme Medical and Scientific Publishers Private Ltd</pub><pmid>32820473</pmid><doi>10.1055/s-0040-1714761</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1305-7456 |
ispartof | European journal of dentistry, 2020-10, Vol.14 (4), p.584-589 |
issn | 1305-7456 1305-7464 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7541334 |
source | PubMed Central Free; Thieme Connect Journals Open Access |
subjects | Original Original Article |
title | Influence of the Chelating Solutions in the Resistance of Glass Fiber Posts to the Root Dentin |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T18%3A13%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20the%20Chelating%20Solutions%20in%20the%20Resistance%20of%20Glass%20Fiber%20Posts%20to%20the%20Root%20Dentin&rft.jtitle=European%20journal%20of%20dentistry&rft.au=Marques,%20Eduardo%20Fernandes&rft.date=2020-10&rft.volume=14&rft.issue=4&rft.spage=584&rft.epage=589&rft.pages=584-589&rft.issn=1305-7456&rft.eissn=1305-7464&rft_id=info:doi/10.1055/s-0040-1714761&rft_dat=%3Cproquest_pubme%3E2436394491%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3201-4e95d1a827df1923ab4b99fdce0845cb23bba769be830675db9e7309e11762b33%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2436394491&rft_id=info:pmid/32820473&rfr_iscdi=true |