Loading…

Influence of the Chelating Solutions in the Resistance of Glass Fiber Posts to the Root Dentin

Abstract Objective  This study aimed to evaluate the influence of chelating agents (EDTA, citric acid and Tetraclean) on glass fiber posts adhesion to root dentin. Materials and Methods  Forty mandibular premolars single canals, with complete apical root, straight, circular cross sections were selec...

Full description

Saved in:
Bibliographic Details
Published in:European journal of dentistry 2020-10, Vol.14 (4), p.584-589
Main Authors: Marques, Eduardo Fernandes, Marceliano-Alves, Marília Fagury Videira, Pelegrine, Rina Andrea, Pinheiro, Sérgio Luiz, Bueno, Carlos Eduardo Da Silveira
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3201-4e95d1a827df1923ab4b99fdce0845cb23bba769be830675db9e7309e11762b33
cites cdi_FETCH-LOGICAL-c3201-4e95d1a827df1923ab4b99fdce0845cb23bba769be830675db9e7309e11762b33
container_end_page 589
container_issue 4
container_start_page 584
container_title European journal of dentistry
container_volume 14
creator Marques, Eduardo Fernandes
Marceliano-Alves, Marília Fagury Videira
Pelegrine, Rina Andrea
Pinheiro, Sérgio Luiz
Bueno, Carlos Eduardo Da Silveira
description Abstract Objective  This study aimed to evaluate the influence of chelating agents (EDTA, citric acid and Tetraclean) on glass fiber posts adhesion to root dentin. Materials and Methods  Forty mandibular premolars single canals, with complete apical root, straight, circular cross sections were selected, accessed and had the cervical third prepared with Gates-Glidden drills, then included in resin, instrumented with ProTaper Universal and the root canal obturation was carried out. After, the samples were randomly divided into 4 groups (n = 10) to test the final irrigation solutions: G1:17% EDTA; G2:10% citric acid; G3: Tetraclean and G4: saline solution (control). After 30 days of storage (36.5° C and 100% humidity), the post preparation was performed leaving 4 mm of apical endodontic filling. Then, a fiber-glass post previously selected was coated with ED Primer adhesive system and resin sealer Panavia, installed and stored for 24 hours at 37°C. The samples were subjected to a tensile test with a constant speed of 1 mm/min with 2000 Kgf. The results were analyzed with the ANOVA test. Results  The statistical analyzes indicated no significant differences between the groups (p > 0.05). Conclusion  The type of chelating agent used in the final irrigation of the endodontic treatment did not influence the tensile strength of the fixation system used to sealer the glass fiber posts to the intracanal dentin.
doi_str_mv 10.1055/s-0040-1714761
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7541334</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2436394491</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3201-4e95d1a827df1923ab4b99fdce0845cb23bba769be830675db9e7309e11762b33</originalsourceid><addsrcrecordid>eNp1kc1LAzEQxYMoflSvnnP0sjXZZJPmIkj9KgiKH1dDsp21kW1Sd7KC_72rLYIHTzPwfu8NzCPkmLMxZ1V1igVjkhVcc6kV3yL7XLCq0FLJ7d-9UnvkAPGNMSWUMbtkT5STkkkt9snLLDZtD7EGmhqaF0CnC2hdDvGVPqa2zyFFpCH-SA-AAbPbwNetQ6RXwUNH7xNmpDmtsZQyvYA4hBySnca1CEebOSLPV5dP05vi9u56Nj2_LWpRMl5IMNWcu0mp5w03pXBeemOaeQ1sIqval8J7p5XxMBFM6WruDWjBDHCuVemFGJGzde6q90sYfDF3rrWrLixd92mTC_avEsPCvqYPqyvJhZBDwMkmoEvvPWC2y4A1tK2LkHq0pRRKGCkNH9DxGq27hNhB83uGM_tdikX7XYrdlDIYirUhLwIswb6lvovDN_7jvwB4NYwo</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2436394491</pqid></control><display><type>article</type><title>Influence of the Chelating Solutions in the Resistance of Glass Fiber Posts to the Root Dentin</title><source>PubMed Central Free</source><source>Thieme Connect Journals Open Access</source><creator>Marques, Eduardo Fernandes ; Marceliano-Alves, Marília Fagury Videira ; Pelegrine, Rina Andrea ; Pinheiro, Sérgio Luiz ; Bueno, Carlos Eduardo Da Silveira</creator><creatorcontrib>Marques, Eduardo Fernandes ; Marceliano-Alves, Marília Fagury Videira ; Pelegrine, Rina Andrea ; Pinheiro, Sérgio Luiz ; Bueno, Carlos Eduardo Da Silveira</creatorcontrib><description>Abstract Objective  This study aimed to evaluate the influence of chelating agents (EDTA, citric acid and Tetraclean) on glass fiber posts adhesion to root dentin. Materials and Methods  Forty mandibular premolars single canals, with complete apical root, straight, circular cross sections were selected, accessed and had the cervical third prepared with Gates-Glidden drills, then included in resin, instrumented with ProTaper Universal and the root canal obturation was carried out. After, the samples were randomly divided into 4 groups (n = 10) to test the final irrigation solutions: G1:17% EDTA; G2:10% citric acid; G3: Tetraclean and G4: saline solution (control). After 30 days of storage (36.5° C and 100% humidity), the post preparation was performed leaving 4 mm of apical endodontic filling. Then, a fiber-glass post previously selected was coated with ED Primer adhesive system and resin sealer Panavia, installed and stored for 24 hours at 37°C. The samples were subjected to a tensile test with a constant speed of 1 mm/min with 2000 Kgf. The results were analyzed with the ANOVA test. Results  The statistical analyzes indicated no significant differences between the groups (p &gt; 0.05). Conclusion  The type of chelating agent used in the final irrigation of the endodontic treatment did not influence the tensile strength of the fixation system used to sealer the glass fiber posts to the intracanal dentin.</description><identifier>ISSN: 1305-7456</identifier><identifier>EISSN: 1305-7464</identifier><identifier>DOI: 10.1055/s-0040-1714761</identifier><identifier>PMID: 32820473</identifier><language>eng</language><publisher>A-12, Second Floor, Sector -2, NOIDA -201301, India: Thieme Medical and Scientific Publishers Private Ltd</publisher><subject>Original ; Original Article</subject><ispartof>European journal of dentistry, 2020-10, Vol.14 (4), p.584-589</ispartof><rights>Dental Investigation Society</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3201-4e95d1a827df1923ab4b99fdce0845cb23bba769be830675db9e7309e11762b33</citedby><cites>FETCH-LOGICAL-c3201-4e95d1a827df1923ab4b99fdce0845cb23bba769be830675db9e7309e11762b33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7541334/pdf/$$EPDF$$P50$$Gpubmedcentral$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7541334/$$EHTML$$P50$$Gpubmedcentral$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,20891,27924,27925,53791,53793,54587,54615</link.rule.ids></links><search><creatorcontrib>Marques, Eduardo Fernandes</creatorcontrib><creatorcontrib>Marceliano-Alves, Marília Fagury Videira</creatorcontrib><creatorcontrib>Pelegrine, Rina Andrea</creatorcontrib><creatorcontrib>Pinheiro, Sérgio Luiz</creatorcontrib><creatorcontrib>Bueno, Carlos Eduardo Da Silveira</creatorcontrib><title>Influence of the Chelating Solutions in the Resistance of Glass Fiber Posts to the Root Dentin</title><title>European journal of dentistry</title><addtitle>Eur J Dent</addtitle><description>Abstract Objective  This study aimed to evaluate the influence of chelating agents (EDTA, citric acid and Tetraclean) on glass fiber posts adhesion to root dentin. Materials and Methods  Forty mandibular premolars single canals, with complete apical root, straight, circular cross sections were selected, accessed and had the cervical third prepared with Gates-Glidden drills, then included in resin, instrumented with ProTaper Universal and the root canal obturation was carried out. After, the samples were randomly divided into 4 groups (n = 10) to test the final irrigation solutions: G1:17% EDTA; G2:10% citric acid; G3: Tetraclean and G4: saline solution (control). After 30 days of storage (36.5° C and 100% humidity), the post preparation was performed leaving 4 mm of apical endodontic filling. Then, a fiber-glass post previously selected was coated with ED Primer adhesive system and resin sealer Panavia, installed and stored for 24 hours at 37°C. The samples were subjected to a tensile test with a constant speed of 1 mm/min with 2000 Kgf. The results were analyzed with the ANOVA test. Results  The statistical analyzes indicated no significant differences between the groups (p &gt; 0.05). Conclusion  The type of chelating agent used in the final irrigation of the endodontic treatment did not influence the tensile strength of the fixation system used to sealer the glass fiber posts to the intracanal dentin.</description><subject>Original</subject><subject>Original Article</subject><issn>1305-7456</issn><issn>1305-7464</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>0U6</sourceid><recordid>eNp1kc1LAzEQxYMoflSvnnP0sjXZZJPmIkj9KgiKH1dDsp21kW1Sd7KC_72rLYIHTzPwfu8NzCPkmLMxZ1V1igVjkhVcc6kV3yL7XLCq0FLJ7d-9UnvkAPGNMSWUMbtkT5STkkkt9snLLDZtD7EGmhqaF0CnC2hdDvGVPqa2zyFFpCH-SA-AAbPbwNetQ6RXwUNH7xNmpDmtsZQyvYA4hBySnca1CEebOSLPV5dP05vi9u56Nj2_LWpRMl5IMNWcu0mp5w03pXBeemOaeQ1sIqval8J7p5XxMBFM6WruDWjBDHCuVemFGJGzde6q90sYfDF3rrWrLixd92mTC_avEsPCvqYPqyvJhZBDwMkmoEvvPWC2y4A1tK2LkHq0pRRKGCkNH9DxGq27hNhB83uGM_tdikX7XYrdlDIYirUhLwIswb6lvovDN_7jvwB4NYwo</recordid><startdate>202010</startdate><enddate>202010</enddate><creator>Marques, Eduardo Fernandes</creator><creator>Marceliano-Alves, Marília Fagury Videira</creator><creator>Pelegrine, Rina Andrea</creator><creator>Pinheiro, Sérgio Luiz</creator><creator>Bueno, Carlos Eduardo Da Silveira</creator><general>Thieme Medical and Scientific Publishers Private Ltd</general><scope>0U6</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope><scope>5PM</scope></search><sort><creationdate>202010</creationdate><title>Influence of the Chelating Solutions in the Resistance of Glass Fiber Posts to the Root Dentin</title><author>Marques, Eduardo Fernandes ; Marceliano-Alves, Marília Fagury Videira ; Pelegrine, Rina Andrea ; Pinheiro, Sérgio Luiz ; Bueno, Carlos Eduardo Da Silveira</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3201-4e95d1a827df1923ab4b99fdce0845cb23bba769be830675db9e7309e11762b33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Original</topic><topic>Original Article</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Marques, Eduardo Fernandes</creatorcontrib><creatorcontrib>Marceliano-Alves, Marília Fagury Videira</creatorcontrib><creatorcontrib>Pelegrine, Rina Andrea</creatorcontrib><creatorcontrib>Pinheiro, Sérgio Luiz</creatorcontrib><creatorcontrib>Bueno, Carlos Eduardo Da Silveira</creatorcontrib><collection>Thieme Connect Journals Open Access</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>European journal of dentistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Marques, Eduardo Fernandes</au><au>Marceliano-Alves, Marília Fagury Videira</au><au>Pelegrine, Rina Andrea</au><au>Pinheiro, Sérgio Luiz</au><au>Bueno, Carlos Eduardo Da Silveira</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of the Chelating Solutions in the Resistance of Glass Fiber Posts to the Root Dentin</atitle><jtitle>European journal of dentistry</jtitle><addtitle>Eur J Dent</addtitle><date>2020-10</date><risdate>2020</risdate><volume>14</volume><issue>4</issue><spage>584</spage><epage>589</epage><pages>584-589</pages><issn>1305-7456</issn><eissn>1305-7464</eissn><abstract>Abstract Objective  This study aimed to evaluate the influence of chelating agents (EDTA, citric acid and Tetraclean) on glass fiber posts adhesion to root dentin. Materials and Methods  Forty mandibular premolars single canals, with complete apical root, straight, circular cross sections were selected, accessed and had the cervical third prepared with Gates-Glidden drills, then included in resin, instrumented with ProTaper Universal and the root canal obturation was carried out. After, the samples were randomly divided into 4 groups (n = 10) to test the final irrigation solutions: G1:17% EDTA; G2:10% citric acid; G3: Tetraclean and G4: saline solution (control). After 30 days of storage (36.5° C and 100% humidity), the post preparation was performed leaving 4 mm of apical endodontic filling. Then, a fiber-glass post previously selected was coated with ED Primer adhesive system and resin sealer Panavia, installed and stored for 24 hours at 37°C. The samples were subjected to a tensile test with a constant speed of 1 mm/min with 2000 Kgf. The results were analyzed with the ANOVA test. Results  The statistical analyzes indicated no significant differences between the groups (p &gt; 0.05). Conclusion  The type of chelating agent used in the final irrigation of the endodontic treatment did not influence the tensile strength of the fixation system used to sealer the glass fiber posts to the intracanal dentin.</abstract><cop>A-12, Second Floor, Sector -2, NOIDA -201301, India</cop><pub>Thieme Medical and Scientific Publishers Private Ltd</pub><pmid>32820473</pmid><doi>10.1055/s-0040-1714761</doi><tpages>6</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1305-7456
ispartof European journal of dentistry, 2020-10, Vol.14 (4), p.584-589
issn 1305-7456
1305-7464
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7541334
source PubMed Central Free; Thieme Connect Journals Open Access
subjects Original
Original Article
title Influence of the Chelating Solutions in the Resistance of Glass Fiber Posts to the Root Dentin
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-02T18%3A13%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20the%20Chelating%20Solutions%20in%20the%20Resistance%20of%20Glass%20Fiber%20Posts%20to%20the%20Root%20Dentin&rft.jtitle=European%20journal%20of%20dentistry&rft.au=Marques,%20Eduardo%20Fernandes&rft.date=2020-10&rft.volume=14&rft.issue=4&rft.spage=584&rft.epage=589&rft.pages=584-589&rft.issn=1305-7456&rft.eissn=1305-7464&rft_id=info:doi/10.1055/s-0040-1714761&rft_dat=%3Cproquest_pubme%3E2436394491%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3201-4e95d1a827df1923ab4b99fdce0845cb23bba769be830675db9e7309e11762b33%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2436394491&rft_id=info:pmid/32820473&rfr_iscdi=true