Uncoiling of a Cook Resonance Metallic Ureteral Stent

Introduction and Background: The Cook Resonance® metallic ureteral stent's unique configuration allows adequate urine drainage while providing improved resistance to external ureteral compression. We report a case in which a stent broke and subsequently uncoiled during stent removal under cysto...

Full description

Saved in:
Bibliographic Details
Published in:Journal of endourology case reports 2020-09, Vol.6 (3), p.228-230
Main Authors: Lo, Eric M., Zhao, Hanson, Gupta, Amit
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c2659-2370d39255cdad02c516ac30969822ae99a840b6eb1744a416fa589f7c80bdc33
container_end_page 230
container_issue 3
container_start_page 228
container_title Journal of endourology case reports
container_volume 6
creator Lo, Eric M.
Zhao, Hanson
Gupta, Amit
description Introduction and Background: The Cook Resonance® metallic ureteral stent's unique configuration allows adequate urine drainage while providing improved resistance to external ureteral compression. We report a case in which a stent broke and subsequently uncoiled during stent removal under cystoscopy. Case Presentation: A 46-year-old woman with a history of cervical carcinoma treated with radiation therapy and chemotherapy and bilateral ureteral strictures presented for cystoscopic removal of bilateral Cook Resonance ureteral stents. During removal of the right ureteral stent, a snap was felt with subsequent uncoiling of the stent. Firm tension to the inner wire and outside curls allowed eventual complete removal of the stent without any retained fragments. Discussion: The all-metal Cook Resonance stent is an attractive alternative to polymeric stents because of reduced frequency of stent exchange and resistance to external compression. However, the metal stent possesses risks such as increased urothelial hyperplasia and stent embedment.
doi_str_mv 10.1089/cren.2020.0049
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7580634</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2443617727</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2659-2370d39255cdad02c516ac30969822ae99a840b6eb1744a416fa589f7c80bdc33</originalsourceid><addsrcrecordid>eNpVkE1Lw0AQhhdRrNRePQc8J85-714EKX5BRVB7XjabTU1Nd-smFfz3JrSInmZghvd9eBC6wFBgUPrKJR8KAgQKAKaP0BmhUudaKX38Z5-gWdetAQBzKTShp2hCKQYiKT1DfBlcbNomrLJYZzabx_iRvfguBhucz558b9u2cdky-d4n22avvQ_9OTqpbdv52WFO0fLu9m3-kC-e7x_nN4vcEcF1PiBARTXh3FW2AuI4FtZR0EIrQqzX2ioGpfAlloxZhkVtudK1dArKylE6Rdf73O2u3PjKDdUDg9mmZmPTt4m2Mf8voXk3q_hlJFcgKBsCLg8BKX7ufNebddylMDAbwhgVWMrBwxQV-y-XYtclX_82YDCjaTOaNqNpM5qmPyiTbvQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2443617727</pqid></control><display><type>article</type><title>Uncoiling of a Cook Resonance Metallic Ureteral Stent</title><source>PubMed Central (Open access)</source><creator>Lo, Eric M. ; Zhao, Hanson ; Gupta, Amit</creator><creatorcontrib>Lo, Eric M. ; Zhao, Hanson ; Gupta, Amit</creatorcontrib><description>Introduction and Background: The Cook Resonance® metallic ureteral stent's unique configuration allows adequate urine drainage while providing improved resistance to external ureteral compression. We report a case in which a stent broke and subsequently uncoiled during stent removal under cystoscopy. Case Presentation: A 46-year-old woman with a history of cervical carcinoma treated with radiation therapy and chemotherapy and bilateral ureteral strictures presented for cystoscopic removal of bilateral Cook Resonance ureteral stents. During removal of the right ureteral stent, a snap was felt with subsequent uncoiling of the stent. Firm tension to the inner wire and outside curls allowed eventual complete removal of the stent without any retained fragments. Discussion: The all-metal Cook Resonance stent is an attractive alternative to polymeric stents because of reduced frequency of stent exchange and resistance to external compression. However, the metal stent possesses risks such as increased urothelial hyperplasia and stent embedment.</description><identifier>ISSN: 2379-9889</identifier><identifier>EISSN: 2379-9889</identifier><identifier>DOI: 10.1089/cren.2020.0049</identifier><identifier>PMID: 33102733</identifier><language>eng</language><publisher>New Rochelle: Mary Ann Liebert, Inc</publisher><subject>Case Reports ; Cervical cancer ; Stents ; Urological surgery</subject><ispartof>Journal of endourology case reports, 2020-09, Vol.6 (3), p.228-230</ispartof><rights>Copyright Mary Ann Liebert, Inc. Sep 2020</rights><rights>Copyright 2020, Mary Ann Liebert, Inc., publishers 2020 Mary Ann Liebert, Inc., publishers</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2659-2370d39255cdad02c516ac30969822ae99a840b6eb1744a416fa589f7c80bdc33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7580634/pdf/$$EPDF$$P50$$Gpubmedcentral$$H</linktopdf><linktohtml>$$Uhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC7580634/$$EHTML$$P50$$Gpubmedcentral$$H</linktohtml><link.rule.ids>230,314,727,780,784,885,27924,27925,53791,53793</link.rule.ids></links><search><creatorcontrib>Lo, Eric M.</creatorcontrib><creatorcontrib>Zhao, Hanson</creatorcontrib><creatorcontrib>Gupta, Amit</creatorcontrib><title>Uncoiling of a Cook Resonance Metallic Ureteral Stent</title><title>Journal of endourology case reports</title><description>Introduction and Background: The Cook Resonance® metallic ureteral stent's unique configuration allows adequate urine drainage while providing improved resistance to external ureteral compression. We report a case in which a stent broke and subsequently uncoiled during stent removal under cystoscopy. Case Presentation: A 46-year-old woman with a history of cervical carcinoma treated with radiation therapy and chemotherapy and bilateral ureteral strictures presented for cystoscopic removal of bilateral Cook Resonance ureteral stents. During removal of the right ureteral stent, a snap was felt with subsequent uncoiling of the stent. Firm tension to the inner wire and outside curls allowed eventual complete removal of the stent without any retained fragments. Discussion: The all-metal Cook Resonance stent is an attractive alternative to polymeric stents because of reduced frequency of stent exchange and resistance to external compression. However, the metal stent possesses risks such as increased urothelial hyperplasia and stent embedment.</description><subject>Case Reports</subject><subject>Cervical cancer</subject><subject>Stents</subject><subject>Urological surgery</subject><issn>2379-9889</issn><issn>2379-9889</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNpVkE1Lw0AQhhdRrNRePQc8J85-714EKX5BRVB7XjabTU1Nd-smFfz3JrSInmZghvd9eBC6wFBgUPrKJR8KAgQKAKaP0BmhUudaKX38Z5-gWdetAQBzKTShp2hCKQYiKT1DfBlcbNomrLJYZzabx_iRvfguBhucz558b9u2cdky-d4n22avvQ_9OTqpbdv52WFO0fLu9m3-kC-e7x_nN4vcEcF1PiBARTXh3FW2AuI4FtZR0EIrQqzX2ioGpfAlloxZhkVtudK1dArKylE6Rdf73O2u3PjKDdUDg9mmZmPTt4m2Mf8voXk3q_hlJFcgKBsCLg8BKX7ufNebddylMDAbwhgVWMrBwxQV-y-XYtclX_82YDCjaTOaNqNpM5qmPyiTbvQ</recordid><startdate>20200901</startdate><enddate>20200901</enddate><creator>Lo, Eric M.</creator><creator>Zhao, Hanson</creator><creator>Gupta, Amit</creator><general>Mary Ann Liebert, Inc</general><general>Mary Ann Liebert, Inc., publishers</general><scope>AAYXX</scope><scope>CITATION</scope><scope>K9.</scope><scope>5PM</scope></search><sort><creationdate>20200901</creationdate><title>Uncoiling of a Cook Resonance Metallic Ureteral Stent</title><author>Lo, Eric M. ; Zhao, Hanson ; Gupta, Amit</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2659-2370d39255cdad02c516ac30969822ae99a840b6eb1744a416fa589f7c80bdc33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Case Reports</topic><topic>Cervical cancer</topic><topic>Stents</topic><topic>Urological surgery</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lo, Eric M.</creatorcontrib><creatorcontrib>Zhao, Hanson</creatorcontrib><creatorcontrib>Gupta, Amit</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Journal of endourology case reports</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lo, Eric M.</au><au>Zhao, Hanson</au><au>Gupta, Amit</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Uncoiling of a Cook Resonance Metallic Ureteral Stent</atitle><jtitle>Journal of endourology case reports</jtitle><date>2020-09-01</date><risdate>2020</risdate><volume>6</volume><issue>3</issue><spage>228</spage><epage>230</epage><pages>228-230</pages><issn>2379-9889</issn><eissn>2379-9889</eissn><abstract>Introduction and Background: The Cook Resonance® metallic ureteral stent's unique configuration allows adequate urine drainage while providing improved resistance to external ureteral compression. We report a case in which a stent broke and subsequently uncoiled during stent removal under cystoscopy. Case Presentation: A 46-year-old woman with a history of cervical carcinoma treated with radiation therapy and chemotherapy and bilateral ureteral strictures presented for cystoscopic removal of bilateral Cook Resonance ureteral stents. During removal of the right ureteral stent, a snap was felt with subsequent uncoiling of the stent. Firm tension to the inner wire and outside curls allowed eventual complete removal of the stent without any retained fragments. Discussion: The all-metal Cook Resonance stent is an attractive alternative to polymeric stents because of reduced frequency of stent exchange and resistance to external compression. However, the metal stent possesses risks such as increased urothelial hyperplasia and stent embedment.</abstract><cop>New Rochelle</cop><pub>Mary Ann Liebert, Inc</pub><pmid>33102733</pmid><doi>10.1089/cren.2020.0049</doi><tpages>3</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2379-9889
ispartof Journal of endourology case reports, 2020-09, Vol.6 (3), p.228-230
issn 2379-9889
2379-9889
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_7580634
source PubMed Central (Open access)
subjects Case Reports
Cervical cancer
Stents
Urological surgery
title Uncoiling of a Cook Resonance Metallic Ureteral Stent
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T10%3A37%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Uncoiling%20of%20a%20Cook%20Resonance%20Metallic%20Ureteral%20Stent&rft.jtitle=Journal%20of%20endourology%20case%20reports&rft.au=Lo,%20Eric%20M.&rft.date=2020-09-01&rft.volume=6&rft.issue=3&rft.spage=228&rft.epage=230&rft.pages=228-230&rft.issn=2379-9889&rft.eissn=2379-9889&rft_id=info:doi/10.1089/cren.2020.0049&rft_dat=%3Cproquest_pubme%3E2443617727%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2659-2370d39255cdad02c516ac30969822ae99a840b6eb1744a416fa589f7c80bdc33%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2443617727&rft_id=info:pmid/33102733&rfr_iscdi=true