PET detectors with 127 ps CTR for the Tachyon-II time-of-flight PET scanner

The signal-to-noise ratio (SNR) of the reconstructed image of Positron Emission Tomography (PET) can be improved by the timing measurement. In this article, we designed, fabricated and tested 32 time-of-flight (TOF) detectors for the second generation of Tachyon TOF-PET scanners. The detector module...

Full description

Saved in:
Bibliographic Details
Published in:Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2019-07, Vol.933, p.48-55
Main Authors: Xie, Siwei, Zhang, Xi, Peng, Hui, Yang, Jingwu, Huang, Qiu, Xu, Jianfeng, Peng, Qiyu
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The signal-to-noise ratio (SNR) of the reconstructed image of Positron Emission Tomography (PET) can be improved by the timing measurement. In this article, we designed, fabricated and tested 32 time-of-flight (TOF) detectors for the second generation of Tachyon TOF-PET scanners. The detector module consists of two arrays of 2 × 12 lutetium–yttrium oxyorthosilicate (LYSO) crystal cubes of 6 ×6× 6 mm3. The discrete crystals were coupled to the 6 mm silicon photomultipliers (SiPMs) with optical glue. All the SiPM were tested for dark current. To correct the errors in the timing measurements caused by time-walk, two compensation methods (log-correction and linear-correction) based on the relationship between energy and timing information were purposed. As a comparison, the SiPM arrays coupled to 4 mm and 6 mm side crystal cube without optical glue were tested for coincidence timing resolution (CTR). The mean and standard deviations (SD) of dark current for the 1536 tested SiPMs were 12.72 +/- 1.70 μA at the bias voltage of 31.5 V and the temperature of 20 °C (±1 °C). CTR performance has increased by ∼5% within a narrow energy window, and ∼10% in a wide energy window by log-correction. The mean and SD of the CTR of 6 mm side crystal cube glue coupled was 126.9 +/- 3.6 ps for the 768 pairs of tested SiPMs. The detector is expected to provide a technical reference for the next generation of ultra-fast CTR commercial PET scanner using multilayer detectors.
ISSN:0168-9002
1872-9576
DOI:10.1016/j.nima.2019.03.083