Loading…

Indoor Formaldehyde Concentration, Personal Formaldehyde Exposure and Clinical Symptoms during Anatomy Dissection Sessions, University of Medicine 1, Yangon

The formaldehyde (FA) embalming method, the world's most common protocol for the fixation of cadavers, has been consistently used in medical universities in Myanmar. This study was designed to examine the indoor FA concentrations in anatomy dissection rooms, an exposed site, and lecture theater...

Full description

Saved in:
Bibliographic Details
Published in:International journal of environmental research and public health 2021-01, Vol.18 (2), p.712
Main Authors: Aung, Win-Yu, Sakamoto, Hironari, Sato, Ayana, Yi, Ei-Ei-Pan-Nu, Thein, Zaw-Lin, Nwe, Myint-San, Shein, Nanda, Linn, Htin, Uchiyama, Shigehisa, Kunugita, Naoki, Win-Shwe, Tin-Tin, Mar, Ohn
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The formaldehyde (FA) embalming method, the world's most common protocol for the fixation of cadavers, has been consistently used in medical universities in Myanmar. This study was designed to examine the indoor FA concentrations in anatomy dissection rooms, an exposed site, and lecture theater, an unexposed control site, and to access personal exposure levels of FA and clinical symptoms of medical students and instructors. In total, 208 second year medical students (1/2019 batch) and 18 instructors from Department of Anatomy, University of Medicine 1, participated. Thirteen dissection sessions were investigated from February 2019 to January 2020. Diffusive sampling devices were used as air samplers and high-performance liquid chromatography was used for measurement of FA. Average indoor FA concentration of four dissection rooms was 0.43 (0.09-1.22) ppm and all dissection rooms showed indoor concentrations above the occupational exposure limits and short-term exposure limit for general population. Personal FA exposure values were higher than indoor FA concentrations and the instructors (0.68, 0.04-2.11 ppm) had higher exposure than the students (0.44, 0.06-1.72 ppm). Unpleasant odor, eye and nose irritations and inability to concentrate were frequently reported FA-related symptoms, and the students were found to have significantly higher risks ( < 0.05) of having these symptoms during the dissection sessions than during lecture.
ISSN:1660-4601
1661-7827
1660-4601
DOI:10.3390/ijerph18020712