Loading…
Accuracy of intraoral scanning in completely and partially edentulous maxillary and mandibular jaws: an in vitro analysis
Objectives New generation intraoral scanners are promoted to be suitable for digital scans of long-span edentulous spaces and completely edentulous arches; however, the evidence is lacking. The current study evaluated the accuracy of intraoral scanning (IOS) in partially and completely edentulous ar...
Saved in:
Published in: | Clinical oral investigations 2021-04, Vol.25 (4), p.1839-1847 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Objectives
New generation intraoral scanners are promoted to be suitable for digital scans of long-span edentulous spaces and completely edentulous arches; however, the evidence is lacking. The current study evaluated the accuracy of intraoral scanning (IOS) in partially and completely edentulous arch models and analyzed the influence of operator experience on accuracy.
Materials and methods
Four different resin models (completely and partially edentulous maxilla and mandible) were scanned, using a new generation IOS device (
n
= 20 each). Ten scans of each model were performed by an IOS-experienced and an inexperienced operator. An industrial high-precision scanner was employed to obtain reference scans. IOS files of each model-operator combination, their respective reference scan files (
n
= 10 each; total = 80), as well as the IOS files from each model generated by the same operator, were superimposed (
n
= 45; total = 360) to calculate trueness and precision. An ANOVA for mixed models and post hoc
t
tests for mixed models were used to assess group-wise differences (α = 0.05).
Results
The median overall trueness and precision were 24.2 μm (IQR 20.7–27.4 μm) and 18.3 μm (IQR 14.4–22.1 μm), respectively. The scans of the inexperienced operator had significantly higher trueness in the edentulous mandibular model (
p
= 0.0001) and higher precision in the edentulous maxillary model (
p
= 0.0004).
Conclusion
The accuracy of IOS for partially and completely edentulous arches in in vitro settings was high. Experience with IOS had small influence on the accuracy of the scans.
Clinical relevance
IOS with the tested new generation intraoral scanner may be suitable for the fabrication of removable dentures regardless of clinician’s experience in IOS. |
---|---|
ISSN: | 1432-6981 1436-3771 |
DOI: | 10.1007/s00784-020-03486-z |