Loading…

Free-breathing Cardiorespiratory Synchronized Cine MRI for Assessment of Left and Right Ventricular Volume and Function in Sedated Children and Adolescents with Impaired Breath-holding Capacity

To prospectively compare left ventricular and right ventricular volume, function, and image quality of a free-breathing (FB) cardiorespiratory synchronized balanced steady-state free precession cine MRI sequence with that of a standard of reference breath-hold (BH) technique in sedated children and...

Full description

Saved in:
Bibliographic Details
Published in:Radiology. Cardiothoracic imaging 2019-06, Vol.1 (2), p.e180027-e180027
Main Authors: Pednekar, Amol S, Jadhav, Siddharth, Noel, Cory, Masand, Prakash
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:To prospectively compare left ventricular and right ventricular volume, function, and image quality of a free-breathing (FB) cardiorespiratory synchronized balanced steady-state free precession cine MRI sequence with that of a standard of reference breath-hold (BH) technique in sedated children and adolescents who are unable to perform BHs. Cohort 1 included 30 patients able to perform BHs (mean age, 19 years; age range, 9-69 years). Cohort 1 underwent both BH and FB cine short-axis imaging with identical acquisition parameters. Cohort 2 included 63 patients unable to perform BHs (50 sedated patients [mean age, 9 years; age range, 4 months to 28 years], 13 unsedated patients [mean age, 21 years; age range, 8-58 years]). Cohort 2 underwent FB cine imaging in multiple views with spatiotemporal resolution equivalent to BH imaging. Comparative quantitative analysis was performed for left ventricular and right ventricular volumes in cohort 1 and for qualitative image quality scores in all patients. Global left ventricular and right ventricular volumetric indexes and image quality scores were comparable between BH and FB sequences in cohort 1. FB image quality was graded as excellent (37 sequences), good (197 sequences), adequate (26 sequences), and suboptimal (three sequences) for 263 cine sequences in cohort 2. In cohort 1, de facto image acquisition time for FB (6.1 minutes ± 1.9 [standard deviation]) was comparable to the equivalent for BH (6.1 minutes ± 2.6) for a stack of 14 sections. In cohorts of sedated children, adolescents, and young adults unable to perform BHs consistently, left ventricular and right ventricular volumes and function were comparable and image quality was noninferior between FB and standard of reference BH techniques.© RSNA, 2019.
ISSN:2638-6135
2638-6135
DOI:10.1148/ryct.2019180027