Loading…
The First 100 Cases of Two Innovations Combined: Video-Assisted Minimally Invasive Aortic Valve Replacement Through Right Anterior Mini-Thoracotomy Using a Novel Aortic Prosthesis
Introduction Aortic valve replacement (AVR) via right anterior mini-thoracotomy (RAMT) is less traumatic than via other surgical routes; using a novel aortic valve may confer long-term resistance against valve deterioration, and thus be useful in younger, more active patients. Here we aim to validat...
Saved in:
Published in: | Advances in therapy 2021-05, Vol.38 (5), p.2435-2446 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Introduction
Aortic valve replacement (AVR) via right anterior mini-thoracotomy (RAMT) is less traumatic than via other surgical routes; using a novel aortic valve may confer long-term resistance against valve deterioration, and thus be useful in younger, more active patients. Here we aim to validate using the INSPIRIS RESILIA valve with minimally invasive RAMT.
Methods
Between April 2017 and June 2019, 100 patients underwent video-assisted minimally invasive AVR by RAMT, using the INSPIRIS RESILIA aortic valve. Cannulation for cardiopulmonary bypass (CPB) was through femoral vessels. Clinical data were prospectively entered into our institutional database.
Results
Cardiopulmonary bypass (CPB) and cross-clamping times were 79 ± 38 and 41 ± 17 min. Surgical access was successful in 100% of cases. There were no cases of intraoperative mortality, 30-day mortality, cerebrovascular events, rethoracotomy for bleeding, valve-related reoperation, right internal mammary artery injury, or conversion to sternotomy. Intensive care and hospital stays were 2 ± 1 and 6 ± 3 days, respectively. One patient had a pacemaker fitted. Postoperative dialysis was necessary in one patient. Trace to mild aortic valve regurgitation occurred in two patients. No structural valve deterioration (SVD) and paravalvular leak were seen. At 1-year follow-up mean effective orifice area (EOA) was 1.8 ± 0.1 cm
2
, peak gradient was 22.1 ± 3.1 mmHg, and mean gradient was 11.5 ± 2.3 mmHg.
Conclusion
Our preliminary experience suggests that RAMT for AVR using the INSPIRIS RESILIA aortic valve is safe, effective, and reproducible. Larger studies are needed to evaluate the long-term efficacy and durability of this new valve. |
---|---|
ISSN: | 0741-238X 1865-8652 |
DOI: | 10.1007/s12325-021-01705-x |