MRI for Guided Right and Left Heart Cardiac Catheterization: A Prospective Study in Congenital Heart Disease
Background Improvements in outcomes for patients with congenital heart disease (CHD) have increased the need for diagnostic and interventional procedures. Cumulative radiation risk is a growing concern. MRI‐guided interventions are a promising ionizing radiation‐free, alternative approach. Purpose T...
Saved in:
Published in: | Journal of magnetic resonance imaging 2021-05, Vol.53 (5), p.1446-1457 |
---|---|
Main Authors: | , , , , , , , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Background
Improvements in outcomes for patients with congenital heart disease (CHD) have increased the need for diagnostic and interventional procedures. Cumulative radiation risk is a growing concern. MRI‐guided interventions are a promising ionizing radiation‐free, alternative approach.
Purpose
To assess the feasibility of MRI‐guided catheterization in young patients with CHD using advanced visualization passive tracking techniques.
Study Type
Prospective.
Population
A total of 30 patients with CHD referred for MRI‐guided catheterization and pulmonary vascular resistance analysis (median age/weight: 4 years / 15 kg).
Field Strength/Sequence
1.5T; partially saturated (pSAT) real‐time single‐shot balanced steady‐state free‐precession (bSSFP) sequence.
Assessment
Images were visualized by a single viewer on the scanner console (interactive mode) or using a commercially available advanced visualization platform (iSuite, Philips). Image quality for anatomy and catheter visualization was evaluated by three cardiologists with >5 years' experience in MRI‐catheterization using a 1–5 scale (1, poor, 5, excellent). Catheter balloon signal‐to‐noise ratio (SNR), blood and myocardium SNR, catheter balloon/blood contrast‐to‐noise ratio (CNR), balloon/myocardium CNR, and blood/myocardium CNR were measured. Procedure findings, feasibility, and adverse events were recorded. A fraction of time in which the catheter was visible was compared between iSuite and the interactive mode.
Statistical Tests
T‐test for numerical variables. Wilcoxon signed rank test for categorical variables.
Results
Nine patients had right heart catheterization, 11 had both left and right heart catheterization, and 10 had single ventricle circulation. Nine patients underwent solely MRI‐guided catheterization. The mean score for anatomical visualization and contrast between balloon tip and soft tissue was 3.9 ± 0.9 and 4.5 ± 0.7, respectively. iSuite provided a significant improvement in the time during which the balloon was visible in relation to interactive imaging mode (66 ± 17% vs. 46 ± 14%, P |
---|---|
ISSN: | 1053-1807 1522-2586 |
DOI: | 10.1002/jmri.27426 |