Loading…

The electrocardiographic forward problem: A benchmark study

Electrocardiographic forward problems are crucial components for noninvasive electrocardiographic imaging (ECGI) that compute torso potentials from cardiac source measurements. Forward problems have few sources of error as they are physically well posed and supported by mature numerical and computat...

Full description

Saved in:
Bibliographic Details
Published in:Computers in biology and medicine 2021-07, Vol.134, p.104476-104476, Article 104476
Main Authors: Bergquist, Jake A., Good, Wilson W., Zenger, Brian, Tate, Jess D., Rupp, Lindsay C., MacLeod, Rob S.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c484t-db0099023ab732a25d17c3410b942c1f8a2ad47e960c12b21438b19b8b61c9f53
cites cdi_FETCH-LOGICAL-c484t-db0099023ab732a25d17c3410b942c1f8a2ad47e960c12b21438b19b8b61c9f53
container_end_page 104476
container_issue
container_start_page 104476
container_title Computers in biology and medicine
container_volume 134
creator Bergquist, Jake A.
Good, Wilson W.
Zenger, Brian
Tate, Jess D.
Rupp, Lindsay C.
MacLeod, Rob S.
description Electrocardiographic forward problems are crucial components for noninvasive electrocardiographic imaging (ECGI) that compute torso potentials from cardiac source measurements. Forward problems have few sources of error as they are physically well posed and supported by mature numerical and computational techniques. However, the residual errors reported from experimental validation studies between forward computed and measured torso signals remain surprisingly high. To test the hypothesis that incomplete cardiac source sampling, especially above the atrioventricular (AV) plane is a major contributor to forward solution errors. We used a modified Langendorff preparation suspended in a human-shaped electrolytic torso-tank and a novel pericardiac-cage recording array to thoroughly sample the cardiac potentials. With this carefully controlled experimental preparation, we minimized possible sources of error, including geometric error and torso inhomogeneities. We progressively removed recorded signals from above the atrioventricular plane to determine how the forward-computed torso-tank potentials were affected by incomplete source sampling. We studied 240 beats total recorded from three different activation sequence types (sinus, and posterior and anterior left-ventricular free-wall pacing) in each of two experiments. With complete sampling by the cage electrodes, all correlation metrics between computed and measured torso-tank potentials were above 0.93 (maximum 0.99). The mean root-mean-squared error across all beat types was also low, less than or equal to 0.10 mV. A precipitous drop in forward solution accuracy was observed when we included only cage measurements below the AV plane. First, our forward computed potentials using complete cardiac source measurements set a benchmark for similar studies. Second, this study validates the importance of complete cardiac source sampling above the AV plane to produce accurate forward computed torso potentials. Testing ECGI systems and techniques with these more complete and highly accurate datasets will improve inverse techniques and noninvasive detection of cardiac electrical abnormalities. •The electrocardiographic forward problem is an essential component of electrocardiographic imaging.•The forward model, despite being solved, produces higher errors than expected in experimental validation studies.•This study describes a benchmark experimental preparation for forward problem solution accuracy across multiple bea
doi_str_mv 10.1016/j.compbiomed.2021.104476
format article
fullrecord <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8263490</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0010482521002705</els_id><sourcerecordid>2547540123</sourcerecordid><originalsourceid>FETCH-LOGICAL-c484t-db0099023ab732a25d17c3410b942c1f8a2ad47e960c12b21438b19b8b61c9f53</originalsourceid><addsrcrecordid>eNqFkUtLxTAQhYMoen38h4IbN73OJOlLQVDxBYIbXYckTb25tk1N2iv-eyNXFN24Gpj55jBzDiEJwhwB8-PlXLtuUNZ1pp5ToBjbnBf5BplhWVQpZIxvkhkAQspLmu2Q3RCWAMCBwTbZYRwy5BmbkdPHhUlMa_TonZa-tu7Zy2FhddI4_xYbyeCdak13kpwnyvR60Un_koRxqt_3yVYj22AOvuoeebq-ery8Te8fbu4uz-9TzUs-prUCqCqgTKqCUUmzGgvNOIKqONXYlJLKmhemykEjVRQ5KxVWqlQ56qrJ2B45W-sOk4oPa9OPXrZi8Dbe8i6ctOL3pLcL8exWoqQ54xVEgaMvAe9eJxNG0dmgTdvK3rgpCBrtyhEzpBE9_IMu3eT7-F6keJFxiFCkyjWlvQvBm-b7GATxmZBYip-ExGdCYp1QXL1Yr5ro2MoaL4K20VdTWx9TELWz_4t8AJu-nIA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2547540123</pqid></control><display><type>article</type><title>The electrocardiographic forward problem: A benchmark study</title><source>ScienceDirect Journals</source><creator>Bergquist, Jake A. ; Good, Wilson W. ; Zenger, Brian ; Tate, Jess D. ; Rupp, Lindsay C. ; MacLeod, Rob S.</creator><creatorcontrib>Bergquist, Jake A. ; Good, Wilson W. ; Zenger, Brian ; Tate, Jess D. ; Rupp, Lindsay C. ; MacLeod, Rob S.</creatorcontrib><description>Electrocardiographic forward problems are crucial components for noninvasive electrocardiographic imaging (ECGI) that compute torso potentials from cardiac source measurements. Forward problems have few sources of error as they are physically well posed and supported by mature numerical and computational techniques. However, the residual errors reported from experimental validation studies between forward computed and measured torso signals remain surprisingly high. To test the hypothesis that incomplete cardiac source sampling, especially above the atrioventricular (AV) plane is a major contributor to forward solution errors. We used a modified Langendorff preparation suspended in a human-shaped electrolytic torso-tank and a novel pericardiac-cage recording array to thoroughly sample the cardiac potentials. With this carefully controlled experimental preparation, we minimized possible sources of error, including geometric error and torso inhomogeneities. We progressively removed recorded signals from above the atrioventricular plane to determine how the forward-computed torso-tank potentials were affected by incomplete source sampling. We studied 240 beats total recorded from three different activation sequence types (sinus, and posterior and anterior left-ventricular free-wall pacing) in each of two experiments. With complete sampling by the cage electrodes, all correlation metrics between computed and measured torso-tank potentials were above 0.93 (maximum 0.99). The mean root-mean-squared error across all beat types was also low, less than or equal to 0.10 mV. A precipitous drop in forward solution accuracy was observed when we included only cage measurements below the AV plane. First, our forward computed potentials using complete cardiac source measurements set a benchmark for similar studies. Second, this study validates the importance of complete cardiac source sampling above the AV plane to produce accurate forward computed torso potentials. Testing ECGI systems and techniques with these more complete and highly accurate datasets will improve inverse techniques and noninvasive detection of cardiac electrical abnormalities. •The electrocardiographic forward problem is an essential component of electrocardiographic imaging.•The forward model, despite being solved, produces higher errors than expected in experimental validation studies.•This study describes a benchmark experimental preparation for forward problem solution accuracy across multiple beat types.•Errors reported previously could be explained by incomplete cardiac source sampling above the atrioventricular plane.•We generated an experimental dataset to test and verify ECGI, which is publicly available on the EDGAR database.</description><identifier>ISSN: 0010-4825</identifier><identifier>EISSN: 1879-0534</identifier><identifier>DOI: 10.1016/j.compbiomed.2021.104476</identifier><identifier>PMID: 34051453</identifier><language>eng</language><publisher>Oxford: Elsevier Ltd</publisher><subject>Abnormalities ; Arrays ; Benchmarks ; Cages ; Cardiac bioelectricity ; Cardiac electrophysiology ; Computation ; Computer applications ; Conductivity ; Electrocardiographic forward problem ; Electrocardiographic imaging ; Electrodes ; Errors ; Experimental cardiac electrophysiology ; Experimental validation ; Experiments ; Forward problem ; Heart ; Laboratory animals ; Sampling ; Signal processing ; Torso ; Validation studies ; Ventricle</subject><ispartof>Computers in biology and medicine, 2021-07, Vol.134, p.104476-104476, Article 104476</ispartof><rights>2021 Elsevier Ltd</rights><rights>2021. Elsevier Ltd</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c484t-db0099023ab732a25d17c3410b942c1f8a2ad47e960c12b21438b19b8b61c9f53</citedby><cites>FETCH-LOGICAL-c484t-db0099023ab732a25d17c3410b942c1f8a2ad47e960c12b21438b19b8b61c9f53</cites><orcidid>0000-0002-0039-9184</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,780,784,885,27924,27925</link.rule.ids></links><search><creatorcontrib>Bergquist, Jake A.</creatorcontrib><creatorcontrib>Good, Wilson W.</creatorcontrib><creatorcontrib>Zenger, Brian</creatorcontrib><creatorcontrib>Tate, Jess D.</creatorcontrib><creatorcontrib>Rupp, Lindsay C.</creatorcontrib><creatorcontrib>MacLeod, Rob S.</creatorcontrib><title>The electrocardiographic forward problem: A benchmark study</title><title>Computers in biology and medicine</title><description>Electrocardiographic forward problems are crucial components for noninvasive electrocardiographic imaging (ECGI) that compute torso potentials from cardiac source measurements. Forward problems have few sources of error as they are physically well posed and supported by mature numerical and computational techniques. However, the residual errors reported from experimental validation studies between forward computed and measured torso signals remain surprisingly high. To test the hypothesis that incomplete cardiac source sampling, especially above the atrioventricular (AV) plane is a major contributor to forward solution errors. We used a modified Langendorff preparation suspended in a human-shaped electrolytic torso-tank and a novel pericardiac-cage recording array to thoroughly sample the cardiac potentials. With this carefully controlled experimental preparation, we minimized possible sources of error, including geometric error and torso inhomogeneities. We progressively removed recorded signals from above the atrioventricular plane to determine how the forward-computed torso-tank potentials were affected by incomplete source sampling. We studied 240 beats total recorded from three different activation sequence types (sinus, and posterior and anterior left-ventricular free-wall pacing) in each of two experiments. With complete sampling by the cage electrodes, all correlation metrics between computed and measured torso-tank potentials were above 0.93 (maximum 0.99). The mean root-mean-squared error across all beat types was also low, less than or equal to 0.10 mV. A precipitous drop in forward solution accuracy was observed when we included only cage measurements below the AV plane. First, our forward computed potentials using complete cardiac source measurements set a benchmark for similar studies. Second, this study validates the importance of complete cardiac source sampling above the AV plane to produce accurate forward computed torso potentials. Testing ECGI systems and techniques with these more complete and highly accurate datasets will improve inverse techniques and noninvasive detection of cardiac electrical abnormalities. •The electrocardiographic forward problem is an essential component of electrocardiographic imaging.•The forward model, despite being solved, produces higher errors than expected in experimental validation studies.•This study describes a benchmark experimental preparation for forward problem solution accuracy across multiple beat types.•Errors reported previously could be explained by incomplete cardiac source sampling above the atrioventricular plane.•We generated an experimental dataset to test and verify ECGI, which is publicly available on the EDGAR database.</description><subject>Abnormalities</subject><subject>Arrays</subject><subject>Benchmarks</subject><subject>Cages</subject><subject>Cardiac bioelectricity</subject><subject>Cardiac electrophysiology</subject><subject>Computation</subject><subject>Computer applications</subject><subject>Conductivity</subject><subject>Electrocardiographic forward problem</subject><subject>Electrocardiographic imaging</subject><subject>Electrodes</subject><subject>Errors</subject><subject>Experimental cardiac electrophysiology</subject><subject>Experimental validation</subject><subject>Experiments</subject><subject>Forward problem</subject><subject>Heart</subject><subject>Laboratory animals</subject><subject>Sampling</subject><subject>Signal processing</subject><subject>Torso</subject><subject>Validation studies</subject><subject>Ventricle</subject><issn>0010-4825</issn><issn>1879-0534</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNqFkUtLxTAQhYMoen38h4IbN73OJOlLQVDxBYIbXYckTb25tk1N2iv-eyNXFN24Gpj55jBzDiEJwhwB8-PlXLtuUNZ1pp5ToBjbnBf5BplhWVQpZIxvkhkAQspLmu2Q3RCWAMCBwTbZYRwy5BmbkdPHhUlMa_TonZa-tu7Zy2FhddI4_xYbyeCdak13kpwnyvR60Un_koRxqt_3yVYj22AOvuoeebq-ery8Te8fbu4uz-9TzUs-prUCqCqgTKqCUUmzGgvNOIKqONXYlJLKmhemykEjVRQ5KxVWqlQ56qrJ2B45W-sOk4oPa9OPXrZi8Dbe8i6ctOL3pLcL8exWoqQ54xVEgaMvAe9eJxNG0dmgTdvK3rgpCBrtyhEzpBE9_IMu3eT7-F6keJFxiFCkyjWlvQvBm-b7GATxmZBYip-ExGdCYp1QXL1Yr5ro2MoaL4K20VdTWx9TELWz_4t8AJu-nIA</recordid><startdate>20210701</startdate><enddate>20210701</enddate><creator>Bergquist, Jake A.</creator><creator>Good, Wilson W.</creator><creator>Zenger, Brian</creator><creator>Tate, Jess D.</creator><creator>Rupp, Lindsay C.</creator><creator>MacLeod, Rob S.</creator><general>Elsevier Ltd</general><general>Elsevier Limited</general><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7RV</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8AL</scope><scope>8AO</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>8G5</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>GUQSH</scope><scope>HCIFZ</scope><scope>JQ2</scope><scope>K7-</scope><scope>K9.</scope><scope>KB0</scope><scope>LK8</scope><scope>M0N</scope><scope>M0S</scope><scope>M1P</scope><scope>M2O</scope><scope>M7P</scope><scope>M7Z</scope><scope>MBDVC</scope><scope>NAPCQ</scope><scope>P5Z</scope><scope>P62</scope><scope>P64</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>Q9U</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-0039-9184</orcidid></search><sort><creationdate>20210701</creationdate><title>The electrocardiographic forward problem: A benchmark study</title><author>Bergquist, Jake A. ; Good, Wilson W. ; Zenger, Brian ; Tate, Jess D. ; Rupp, Lindsay C. ; MacLeod, Rob S.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c484t-db0099023ab732a25d17c3410b942c1f8a2ad47e960c12b21438b19b8b61c9f53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Abnormalities</topic><topic>Arrays</topic><topic>Benchmarks</topic><topic>Cages</topic><topic>Cardiac bioelectricity</topic><topic>Cardiac electrophysiology</topic><topic>Computation</topic><topic>Computer applications</topic><topic>Conductivity</topic><topic>Electrocardiographic forward problem</topic><topic>Electrocardiographic imaging</topic><topic>Electrodes</topic><topic>Errors</topic><topic>Experimental cardiac electrophysiology</topic><topic>Experimental validation</topic><topic>Experiments</topic><topic>Forward problem</topic><topic>Heart</topic><topic>Laboratory animals</topic><topic>Sampling</topic><topic>Signal processing</topic><topic>Torso</topic><topic>Validation studies</topic><topic>Ventricle</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Bergquist, Jake A.</creatorcontrib><creatorcontrib>Good, Wilson W.</creatorcontrib><creatorcontrib>Zenger, Brian</creatorcontrib><creatorcontrib>Tate, Jess D.</creatorcontrib><creatorcontrib>Rupp, Lindsay C.</creatorcontrib><creatorcontrib>MacLeod, Rob S.</creatorcontrib><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Nursing &amp; Allied Health Database</collection><collection>ProQuest Health and Medical</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Computing Database (Alumni Edition)</collection><collection>ProQuest Pharma Collection</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>Research Library (Alumni Edition)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Advanced Technologies &amp; Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>Research Library Prep</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Computer Science Collection</collection><collection>Computer science database</collection><collection>ProQuest Health &amp; Medical Complete (Alumni)</collection><collection>Nursing &amp; Allied Health Database (Alumni Edition)</collection><collection>ProQuest Biological Science Collection</collection><collection>Computing Database</collection><collection>Health &amp; Medical Collection (Alumni Edition)</collection><collection>Medical Database</collection><collection>ProQuest Research Library</collection><collection>ProQuest Biological Science Journals</collection><collection>Biochemistry Abstracts 1</collection><collection>Research Library (Corporate)</collection><collection>Nursing &amp; Allied Health Premium</collection><collection>ProQuest advanced technologies &amp; aerospace journals</collection><collection>ProQuest Advanced Technologies &amp; Aerospace Collection</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>ProQuest Central Basic</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Computers in biology and medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Bergquist, Jake A.</au><au>Good, Wilson W.</au><au>Zenger, Brian</au><au>Tate, Jess D.</au><au>Rupp, Lindsay C.</au><au>MacLeod, Rob S.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The electrocardiographic forward problem: A benchmark study</atitle><jtitle>Computers in biology and medicine</jtitle><date>2021-07-01</date><risdate>2021</risdate><volume>134</volume><spage>104476</spage><epage>104476</epage><pages>104476-104476</pages><artnum>104476</artnum><issn>0010-4825</issn><eissn>1879-0534</eissn><abstract>Electrocardiographic forward problems are crucial components for noninvasive electrocardiographic imaging (ECGI) that compute torso potentials from cardiac source measurements. Forward problems have few sources of error as they are physically well posed and supported by mature numerical and computational techniques. However, the residual errors reported from experimental validation studies between forward computed and measured torso signals remain surprisingly high. To test the hypothesis that incomplete cardiac source sampling, especially above the atrioventricular (AV) plane is a major contributor to forward solution errors. We used a modified Langendorff preparation suspended in a human-shaped electrolytic torso-tank and a novel pericardiac-cage recording array to thoroughly sample the cardiac potentials. With this carefully controlled experimental preparation, we minimized possible sources of error, including geometric error and torso inhomogeneities. We progressively removed recorded signals from above the atrioventricular plane to determine how the forward-computed torso-tank potentials were affected by incomplete source sampling. We studied 240 beats total recorded from three different activation sequence types (sinus, and posterior and anterior left-ventricular free-wall pacing) in each of two experiments. With complete sampling by the cage electrodes, all correlation metrics between computed and measured torso-tank potentials were above 0.93 (maximum 0.99). The mean root-mean-squared error across all beat types was also low, less than or equal to 0.10 mV. A precipitous drop in forward solution accuracy was observed when we included only cage measurements below the AV plane. First, our forward computed potentials using complete cardiac source measurements set a benchmark for similar studies. Second, this study validates the importance of complete cardiac source sampling above the AV plane to produce accurate forward computed torso potentials. Testing ECGI systems and techniques with these more complete and highly accurate datasets will improve inverse techniques and noninvasive detection of cardiac electrical abnormalities. •The electrocardiographic forward problem is an essential component of electrocardiographic imaging.•The forward model, despite being solved, produces higher errors than expected in experimental validation studies.•This study describes a benchmark experimental preparation for forward problem solution accuracy across multiple beat types.•Errors reported previously could be explained by incomplete cardiac source sampling above the atrioventricular plane.•We generated an experimental dataset to test and verify ECGI, which is publicly available on the EDGAR database.</abstract><cop>Oxford</cop><pub>Elsevier Ltd</pub><pmid>34051453</pmid><doi>10.1016/j.compbiomed.2021.104476</doi><tpages>1</tpages><orcidid>https://orcid.org/0000-0002-0039-9184</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0010-4825
ispartof Computers in biology and medicine, 2021-07, Vol.134, p.104476-104476, Article 104476
issn 0010-4825
1879-0534
language eng
recordid cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8263490
source ScienceDirect Journals
subjects Abnormalities
Arrays
Benchmarks
Cages
Cardiac bioelectricity
Cardiac electrophysiology
Computation
Computer applications
Conductivity
Electrocardiographic forward problem
Electrocardiographic imaging
Electrodes
Errors
Experimental cardiac electrophysiology
Experimental validation
Experiments
Forward problem
Heart
Laboratory animals
Sampling
Signal processing
Torso
Validation studies
Ventricle
title The electrocardiographic forward problem: A benchmark study
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T16%3A26%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20electrocardiographic%20forward%20problem:%20A%20benchmark%20study&rft.jtitle=Computers%20in%20biology%20and%20medicine&rft.au=Bergquist,%20Jake%20A.&rft.date=2021-07-01&rft.volume=134&rft.spage=104476&rft.epage=104476&rft.pages=104476-104476&rft.artnum=104476&rft.issn=0010-4825&rft.eissn=1879-0534&rft_id=info:doi/10.1016/j.compbiomed.2021.104476&rft_dat=%3Cproquest_pubme%3E2547540123%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c484t-db0099023ab732a25d17c3410b942c1f8a2ad47e960c12b21438b19b8b61c9f53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2547540123&rft_id=info:pmid/34051453&rfr_iscdi=true