Loading…
Fast and Precise Non-Contact Measurement of Cylindrical Surfaces with Air Gauges
In this paper, the results of an investigation on the application of air gauges in the measurement of out-of-roundness parameters are presented. The principle of the measuring system is explained, in particular the novel design of the floating gauge head. An algorithm for fully automated measurement...
Saved in:
Published in: | Materials 2021-07, Vol.14 (13), p.3728 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c313t-23d0af5ace198bdf9f283176f4bc69cd24215a0483887034d5800c2f581a1d083 |
---|---|
cites | cdi_FETCH-LOGICAL-c313t-23d0af5ace198bdf9f283176f4bc69cd24215a0483887034d5800c2f581a1d083 |
container_end_page | |
container_issue | 13 |
container_start_page | 3728 |
container_title | Materials |
container_volume | 14 |
creator | Jermak, Czeslaw Janusz Jakubowicz, Michal Wieczorowski, Michal Rucki, Miroslaw |
description | In this paper, the results of an investigation on the application of air gauges in the measurement of out-of-roundness parameters are presented. The principle of the measuring system is explained, in particular the novel design of the floating gauge head. An algorithm for fully automated measurement and data processing is described. The results from a series of initial measurements provided the data for further simulations, which revealed possible sources of errors. The simulations helped to evaluate the influence of some of the parameters on the final measurement results. After various accuracy tests, the method accuracy (MA) parameter was calculated in relation to the dedicated reference form tester. The result MA = 9.29% was judged to be highly satisfactory considering the short measurement time and non-contact method. |
doi_str_mv | 10.3390/ma14133728 |
format | article |
fullrecord | <record><control><sourceid>proquest_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8269857</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2553233736</sourcerecordid><originalsourceid>FETCH-LOGICAL-c313t-23d0af5ace198bdf9f283176f4bc69cd24215a0483887034d5800c2f581a1d083</originalsourceid><addsrcrecordid>eNpdkVtLxDAQhYMo7rLui78g4IsI1SSTtsmLIIs3WHVBfQ7ZNNEsbaNJq-y_t4vibV5mYD4OZ-YgtE_JMYAkJ42mnAKUTGyhMZWyyKjkfPvXPELTlFZkKAAqmNxFI-CslEwWY7S40KnDuq3wIlrjk8W3oc1moe206fCN1amPtrFth4PDs3Xt2yp6o2t830enjU343XfP-MxHfKn7J5v20I7TdbLTrz5BjxfnD7OrbH53eT07m2cGKHQZg4polw8KVIpl5aRjAmhZOL40hTQV44zmmnABQpQEeJULQgxzuaCaVkTABJ1-6r70y8ZWZrAYda1eom90XKugvfq7af2zegpvSrBCirwcBA6_BGJ47W3qVOOTsXWtWxv6pFieAxseC8WAHvxDV6GP7XDeQHHJBQG6oY4-KRNDStG6bzOUqE1W6icr-AC5eoPL</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2549480316</pqid></control><display><type>article</type><title>Fast and Precise Non-Contact Measurement of Cylindrical Surfaces with Air Gauges</title><source>NCBI_PubMed Central(免费)</source><source>ProQuest - Publicly Available Content Database</source><source>Free Full-Text Journals in Chemistry</source><creator>Jermak, Czeslaw Janusz ; Jakubowicz, Michal ; Wieczorowski, Michal ; Rucki, Miroslaw</creator><creatorcontrib>Jermak, Czeslaw Janusz ; Jakubowicz, Michal ; Wieczorowski, Michal ; Rucki, Miroslaw</creatorcontrib><description>In this paper, the results of an investigation on the application of air gauges in the measurement of out-of-roundness parameters are presented. The principle of the measuring system is explained, in particular the novel design of the floating gauge head. An algorithm for fully automated measurement and data processing is described. The results from a series of initial measurements provided the data for further simulations, which revealed possible sources of errors. The simulations helped to evaluate the influence of some of the parameters on the final measurement results. After various accuracy tests, the method accuracy (MA) parameter was calculated in relation to the dedicated reference form tester. The result MA = 9.29% was judged to be highly satisfactory considering the short measurement time and non-contact method.</description><identifier>ISSN: 1996-1944</identifier><identifier>EISSN: 1996-1944</identifier><identifier>DOI: 10.3390/ma14133728</identifier><identifier>PMID: 34279296</identifier><language>eng</language><publisher>Basel: MDPI AG</publisher><subject>Accuracy ; Algorithms ; Data collection ; Data processing ; Data smoothing ; Data transmission ; Gauges ; Nozzles ; Parameters ; Roundness ; Software ; Topography</subject><ispartof>Materials, 2021-07, Vol.14 (13), p.3728</ispartof><rights>2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>2021 by the authors. 2021</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c313t-23d0af5ace198bdf9f283176f4bc69cd24215a0483887034d5800c2f581a1d083</citedby><cites>FETCH-LOGICAL-c313t-23d0af5ace198bdf9f283176f4bc69cd24215a0483887034d5800c2f581a1d083</cites><orcidid>0000-0002-6350-0411 ; 0000-0001-7526-8368 ; 0000-0001-7666-7686</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2549480316/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2549480316?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,727,780,784,885,25753,27924,27925,37012,37013,44590,53791,53793,75126</link.rule.ids></links><search><creatorcontrib>Jermak, Czeslaw Janusz</creatorcontrib><creatorcontrib>Jakubowicz, Michal</creatorcontrib><creatorcontrib>Wieczorowski, Michal</creatorcontrib><creatorcontrib>Rucki, Miroslaw</creatorcontrib><title>Fast and Precise Non-Contact Measurement of Cylindrical Surfaces with Air Gauges</title><title>Materials</title><description>In this paper, the results of an investigation on the application of air gauges in the measurement of out-of-roundness parameters are presented. The principle of the measuring system is explained, in particular the novel design of the floating gauge head. An algorithm for fully automated measurement and data processing is described. The results from a series of initial measurements provided the data for further simulations, which revealed possible sources of errors. The simulations helped to evaluate the influence of some of the parameters on the final measurement results. After various accuracy tests, the method accuracy (MA) parameter was calculated in relation to the dedicated reference form tester. The result MA = 9.29% was judged to be highly satisfactory considering the short measurement time and non-contact method.</description><subject>Accuracy</subject><subject>Algorithms</subject><subject>Data collection</subject><subject>Data processing</subject><subject>Data smoothing</subject><subject>Data transmission</subject><subject>Gauges</subject><subject>Nozzles</subject><subject>Parameters</subject><subject>Roundness</subject><subject>Software</subject><subject>Topography</subject><issn>1996-1944</issn><issn>1996-1944</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNpdkVtLxDAQhYMo7rLui78g4IsI1SSTtsmLIIs3WHVBfQ7ZNNEsbaNJq-y_t4vibV5mYD4OZ-YgtE_JMYAkJ42mnAKUTGyhMZWyyKjkfPvXPELTlFZkKAAqmNxFI-CslEwWY7S40KnDuq3wIlrjk8W3oc1moe206fCN1amPtrFth4PDs3Xt2yp6o2t830enjU343XfP-MxHfKn7J5v20I7TdbLTrz5BjxfnD7OrbH53eT07m2cGKHQZg4polw8KVIpl5aRjAmhZOL40hTQV44zmmnABQpQEeJULQgxzuaCaVkTABJ1-6r70y8ZWZrAYda1eom90XKugvfq7af2zegpvSrBCirwcBA6_BGJ47W3qVOOTsXWtWxv6pFieAxseC8WAHvxDV6GP7XDeQHHJBQG6oY4-KRNDStG6bzOUqE1W6icr-AC5eoPL</recordid><startdate>20210702</startdate><enddate>20210702</enddate><creator>Jermak, Czeslaw Janusz</creator><creator>Jakubowicz, Michal</creator><creator>Wieczorowski, Michal</creator><creator>Rucki, Miroslaw</creator><general>MDPI AG</general><general>MDPI</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>D1I</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>JG9</scope><scope>KB.</scope><scope>PDBOC</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0002-6350-0411</orcidid><orcidid>https://orcid.org/0000-0001-7526-8368</orcidid><orcidid>https://orcid.org/0000-0001-7666-7686</orcidid></search><sort><creationdate>20210702</creationdate><title>Fast and Precise Non-Contact Measurement of Cylindrical Surfaces with Air Gauges</title><author>Jermak, Czeslaw Janusz ; Jakubowicz, Michal ; Wieczorowski, Michal ; Rucki, Miroslaw</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c313t-23d0af5ace198bdf9f283176f4bc69cd24215a0483887034d5800c2f581a1d083</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Accuracy</topic><topic>Algorithms</topic><topic>Data collection</topic><topic>Data processing</topic><topic>Data smoothing</topic><topic>Data transmission</topic><topic>Gauges</topic><topic>Nozzles</topic><topic>Parameters</topic><topic>Roundness</topic><topic>Software</topic><topic>Topography</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jermak, Czeslaw Janusz</creatorcontrib><creatorcontrib>Jakubowicz, Michal</creatorcontrib><creatorcontrib>Wieczorowski, Michal</creatorcontrib><creatorcontrib>Rucki, Miroslaw</creatorcontrib><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>ProQuest Central Essentials</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Materials Science Collection</collection><collection>ProQuest Central</collection><collection>SciTech Premium Collection</collection><collection>Materials Research Database</collection><collection>Materials Science Database</collection><collection>Materials Science Collection</collection><collection>ProQuest - Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>Materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jermak, Czeslaw Janusz</au><au>Jakubowicz, Michal</au><au>Wieczorowski, Michal</au><au>Rucki, Miroslaw</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fast and Precise Non-Contact Measurement of Cylindrical Surfaces with Air Gauges</atitle><jtitle>Materials</jtitle><date>2021-07-02</date><risdate>2021</risdate><volume>14</volume><issue>13</issue><spage>3728</spage><pages>3728-</pages><issn>1996-1944</issn><eissn>1996-1944</eissn><abstract>In this paper, the results of an investigation on the application of air gauges in the measurement of out-of-roundness parameters are presented. The principle of the measuring system is explained, in particular the novel design of the floating gauge head. An algorithm for fully automated measurement and data processing is described. The results from a series of initial measurements provided the data for further simulations, which revealed possible sources of errors. The simulations helped to evaluate the influence of some of the parameters on the final measurement results. After various accuracy tests, the method accuracy (MA) parameter was calculated in relation to the dedicated reference form tester. The result MA = 9.29% was judged to be highly satisfactory considering the short measurement time and non-contact method.</abstract><cop>Basel</cop><pub>MDPI AG</pub><pmid>34279296</pmid><doi>10.3390/ma14133728</doi><orcidid>https://orcid.org/0000-0002-6350-0411</orcidid><orcidid>https://orcid.org/0000-0001-7526-8368</orcidid><orcidid>https://orcid.org/0000-0001-7666-7686</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1996-1944 |
ispartof | Materials, 2021-07, Vol.14 (13), p.3728 |
issn | 1996-1944 1996-1944 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8269857 |
source | NCBI_PubMed Central(免费); ProQuest - Publicly Available Content Database; Free Full-Text Journals in Chemistry |
subjects | Accuracy Algorithms Data collection Data processing Data smoothing Data transmission Gauges Nozzles Parameters Roundness Software Topography |
title | Fast and Precise Non-Contact Measurement of Cylindrical Surfaces with Air Gauges |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T05%3A28%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fast%20and%20Precise%20Non-Contact%20Measurement%20of%20Cylindrical%20Surfaces%20with%20Air%20Gauges&rft.jtitle=Materials&rft.au=Jermak,%20Czeslaw%20Janusz&rft.date=2021-07-02&rft.volume=14&rft.issue=13&rft.spage=3728&rft.pages=3728-&rft.issn=1996-1944&rft.eissn=1996-1944&rft_id=info:doi/10.3390/ma14133728&rft_dat=%3Cproquest_pubme%3E2553233736%3C/proquest_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c313t-23d0af5ace198bdf9f283176f4bc69cd24215a0483887034d5800c2f581a1d083%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2549480316&rft_id=info:pmid/34279296&rfr_iscdi=true |