Loading…
Surgical Drill Guide for Insertion of an Infra-Acetabular Screw Based on an Anatomically Precontoured Plate System: A Cadaveric Study
Purpose. Due to the anatomic structure of the pelvis, free-hand placement of screws in the acetabular fracture management can be difficult. Infra-acetabular screw fixation increases acetabular stability by distal fixation of the cup. Aim of this cadaveric study is to investigate if a plate-reference...
Saved in:
Published in: | BioMed research international 2021, Vol.2021, p.1-7 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c481t-2ca4e373c14c005f6680959b66c0cedd911f15a9c25c0fe25488f94afe8144df3 |
---|---|
cites | cdi_FETCH-LOGICAL-c481t-2ca4e373c14c005f6680959b66c0cedd911f15a9c25c0fe25488f94afe8144df3 |
container_end_page | 7 |
container_issue | |
container_start_page | 1 |
container_title | BioMed research international |
container_volume | 2021 |
creator | Freigang, Viola Gottsauner, Maximilian Rupp, Markus Pfeifer, Christian Grechenig, Stephan Kerner, Alexander Alt, Volker Baumann, Florian |
description | Purpose. Due to the anatomic structure of the pelvis, free-hand placement of screws in the acetabular fracture management can be difficult. Infra-acetabular screw fixation increases acetabular stability by distal fixation of the cup. Aim of this cadaveric study is to investigate if a plate-referenced drill guide can provide save placement of an infra-acetabular screw over a precontoured suprapectineal quadrilateral buttress plate (SQBP). Methods. We constructed a drill guide for an infra-acetabular screw based on the surface of an anatomically precontoured SQBP. A total of 12 adult cadaveric acetabular specimens were used for drill guide-assisted placement of the infra-acetabular screw. The drill guide contains a radiopaque spiral to allow longitudinal fine adjustment of the SQBP along the pelvic brim to assure correct position of the plate-drill-guide construct in relation to the Koehler’s teardrop. After screw placement, we conducted a computed tomography (CT) scan of all specimens to assess the actual position of the screw in relation of the infra-acetabular corridor and the acetabular joint surface. Results. The position of the screw was within the infra-acetabular corridor in all cases. We did not see any intra-articular or intrapelvic screw penetration. The mean distance of the centerline of the screw to the medial border of the infra-acetabular corridor was 3.35 mm. The secure distance to the virtual surface of the femoral head to was 7.3 mm. Conclusions. A plate-referenced drill guide can provide safe placement of an infra-acetabular screw for treatment of acetabular fractures. Radiographic fine adjustment is necessary to access the optimal entry point. |
doi_str_mv | 10.1155/2021/2321504 |
format | article |
fullrecord | <record><control><sourceid>gale_pubme</sourceid><recordid>TN_cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8331300</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A696876546</galeid><sourcerecordid>A696876546</sourcerecordid><originalsourceid>FETCH-LOGICAL-c481t-2ca4e373c14c005f6680959b66c0cedd911f15a9c25c0fe25488f94afe8144df3</originalsourceid><addsrcrecordid>eNp9kt9qFDEUhwdRbKm98wEC3gg6Nv93xgthXLUWChZWr0M2c7JNySQ1ybTsA_jeZt2lohfNTRLOly854dc0Lwl-R4gQZxRTckYZJQLzJ80xZYS3knDy9GHN2FFzmvMNrqMjEvfyeXPEOBP1BD5ufq3mtHFGe_QpOe_R-exGQDYmdBEypOJiQNEiHereJt0OBopez14ntDIJ7tFHnWFElarIEHSJ087mt-gqgYmhxDnV-pXXBdBqmwtM79GAlnrUd5CcQasyj9sXzTOrfYbTw3zS_Pjy-fvya3v57fxiOVy2hnektNRoDmzBDOEGY2Gl7HAv-rWUBhsYx54QS4TuDRUGW6CCd53tubbQEc5Hy06aD3vv7byeYDQQStJe3SY36bRVUTv1byW4a7WJd6pjjDCMq-D1QZDizxlyUZPLBrzXAeKcFRWi55TLBa3oq__Qm_oXobb3h2Ksvhb_pTbag3LBxnqv2UnVIHvZLaTg8nGqY2LBKO8q9XZPmRRzTmAfGiNY7eKidnFRh7hU_M0ev3Zh1Pfucfo3qcW7PA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2559339110</pqid></control><display><type>article</type><title>Surgical Drill Guide for Insertion of an Infra-Acetabular Screw Based on an Anatomically Precontoured Plate System: A Cadaveric Study</title><source>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</source><source>Wiley Online Library Open Access</source><creator>Freigang, Viola ; Gottsauner, Maximilian ; Rupp, Markus ; Pfeifer, Christian ; Grechenig, Stephan ; Kerner, Alexander ; Alt, Volker ; Baumann, Florian</creator><contributor>Fortina, Mattia ; Mattia Fortina</contributor><creatorcontrib>Freigang, Viola ; Gottsauner, Maximilian ; Rupp, Markus ; Pfeifer, Christian ; Grechenig, Stephan ; Kerner, Alexander ; Alt, Volker ; Baumann, Florian ; Fortina, Mattia ; Mattia Fortina</creatorcontrib><description>Purpose. Due to the anatomic structure of the pelvis, free-hand placement of screws in the acetabular fracture management can be difficult. Infra-acetabular screw fixation increases acetabular stability by distal fixation of the cup. Aim of this cadaveric study is to investigate if a plate-referenced drill guide can provide save placement of an infra-acetabular screw over a precontoured suprapectineal quadrilateral buttress plate (SQBP). Methods. We constructed a drill guide for an infra-acetabular screw based on the surface of an anatomically precontoured SQBP. A total of 12 adult cadaveric acetabular specimens were used for drill guide-assisted placement of the infra-acetabular screw. The drill guide contains a radiopaque spiral to allow longitudinal fine adjustment of the SQBP along the pelvic brim to assure correct position of the plate-drill-guide construct in relation to the Koehler’s teardrop. After screw placement, we conducted a computed tomography (CT) scan of all specimens to assess the actual position of the screw in relation of the infra-acetabular corridor and the acetabular joint surface. Results. The position of the screw was within the infra-acetabular corridor in all cases. We did not see any intra-articular or intrapelvic screw penetration. The mean distance of the centerline of the screw to the medial border of the infra-acetabular corridor was 3.35 mm. The secure distance to the virtual surface of the femoral head to was 7.3 mm. Conclusions. A plate-referenced drill guide can provide safe placement of an infra-acetabular screw for treatment of acetabular fractures. Radiographic fine adjustment is necessary to access the optimal entry point.</description><identifier>ISSN: 2314-6133</identifier><identifier>EISSN: 2314-6141</identifier><identifier>DOI: 10.1155/2021/2321504</identifier><identifier>PMID: 34355040</identifier><language>eng</language><publisher>New York: Hindawi</publisher><subject>Acetabulum ; Analysis ; Bone implants ; Buttresses ; Cadavers ; Cartilage ; Computed tomography ; Fixation ; Fracture fixation ; Fractures ; Hip joint ; Internal fixation in fractures ; Management ; Methods ; Pelvis ; Quadrilaterals ; Software ; Statistical analysis ; Surgical techniques</subject><ispartof>BioMed research international, 2021, Vol.2021, p.1-7</ispartof><rights>Copyright © 2021 Viola Freigang et al.</rights><rights>COPYRIGHT 2021 John Wiley & Sons, Inc.</rights><rights>Copyright © 2021 Viola Freigang et al. This is an open access article distributed under the Creative Commons Attribution License (the “License”), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. https://creativecommons.org/licenses/by/4.0</rights><rights>Copyright © 2021 Viola Freigang et al. 2021</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c481t-2ca4e373c14c005f6680959b66c0cedd911f15a9c25c0fe25488f94afe8144df3</citedby><cites>FETCH-LOGICAL-c481t-2ca4e373c14c005f6680959b66c0cedd911f15a9c25c0fe25488f94afe8144df3</cites><orcidid>0000-0003-1413-3587</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://www.proquest.com/docview/2559339110/fulltextPDF?pq-origsite=primo$$EPDF$$P50$$Gproquest$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://www.proquest.com/docview/2559339110?pq-origsite=primo$$EHTML$$P50$$Gproquest$$Hfree_for_read</linktohtml><link.rule.ids>230,314,780,784,885,4024,25753,27923,27924,27925,37012,37013,44590,75126</link.rule.ids></links><search><contributor>Fortina, Mattia</contributor><contributor>Mattia Fortina</contributor><creatorcontrib>Freigang, Viola</creatorcontrib><creatorcontrib>Gottsauner, Maximilian</creatorcontrib><creatorcontrib>Rupp, Markus</creatorcontrib><creatorcontrib>Pfeifer, Christian</creatorcontrib><creatorcontrib>Grechenig, Stephan</creatorcontrib><creatorcontrib>Kerner, Alexander</creatorcontrib><creatorcontrib>Alt, Volker</creatorcontrib><creatorcontrib>Baumann, Florian</creatorcontrib><title>Surgical Drill Guide for Insertion of an Infra-Acetabular Screw Based on an Anatomically Precontoured Plate System: A Cadaveric Study</title><title>BioMed research international</title><description>Purpose. Due to the anatomic structure of the pelvis, free-hand placement of screws in the acetabular fracture management can be difficult. Infra-acetabular screw fixation increases acetabular stability by distal fixation of the cup. Aim of this cadaveric study is to investigate if a plate-referenced drill guide can provide save placement of an infra-acetabular screw over a precontoured suprapectineal quadrilateral buttress plate (SQBP). Methods. We constructed a drill guide for an infra-acetabular screw based on the surface of an anatomically precontoured SQBP. A total of 12 adult cadaveric acetabular specimens were used for drill guide-assisted placement of the infra-acetabular screw. The drill guide contains a radiopaque spiral to allow longitudinal fine adjustment of the SQBP along the pelvic brim to assure correct position of the plate-drill-guide construct in relation to the Koehler’s teardrop. After screw placement, we conducted a computed tomography (CT) scan of all specimens to assess the actual position of the screw in relation of the infra-acetabular corridor and the acetabular joint surface. Results. The position of the screw was within the infra-acetabular corridor in all cases. We did not see any intra-articular or intrapelvic screw penetration. The mean distance of the centerline of the screw to the medial border of the infra-acetabular corridor was 3.35 mm. The secure distance to the virtual surface of the femoral head to was 7.3 mm. Conclusions. A plate-referenced drill guide can provide safe placement of an infra-acetabular screw for treatment of acetabular fractures. Radiographic fine adjustment is necessary to access the optimal entry point.</description><subject>Acetabulum</subject><subject>Analysis</subject><subject>Bone implants</subject><subject>Buttresses</subject><subject>Cadavers</subject><subject>Cartilage</subject><subject>Computed tomography</subject><subject>Fixation</subject><subject>Fracture fixation</subject><subject>Fractures</subject><subject>Hip joint</subject><subject>Internal fixation in fractures</subject><subject>Management</subject><subject>Methods</subject><subject>Pelvis</subject><subject>Quadrilaterals</subject><subject>Software</subject><subject>Statistical analysis</subject><subject>Surgical techniques</subject><issn>2314-6133</issn><issn>2314-6141</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>PIMPY</sourceid><recordid>eNp9kt9qFDEUhwdRbKm98wEC3gg6Nv93xgthXLUWChZWr0M2c7JNySQ1ybTsA_jeZt2lohfNTRLOly854dc0Lwl-R4gQZxRTckYZJQLzJ80xZYS3knDy9GHN2FFzmvMNrqMjEvfyeXPEOBP1BD5ufq3mtHFGe_QpOe_R-exGQDYmdBEypOJiQNEiHereJt0OBopez14ntDIJ7tFHnWFElarIEHSJ087mt-gqgYmhxDnV-pXXBdBqmwtM79GAlnrUd5CcQasyj9sXzTOrfYbTw3zS_Pjy-fvya3v57fxiOVy2hnektNRoDmzBDOEGY2Gl7HAv-rWUBhsYx54QS4TuDRUGW6CCd53tubbQEc5Hy06aD3vv7byeYDQQStJe3SY36bRVUTv1byW4a7WJd6pjjDCMq-D1QZDizxlyUZPLBrzXAeKcFRWi55TLBa3oq__Qm_oXobb3h2Ksvhb_pTbag3LBxnqv2UnVIHvZLaTg8nGqY2LBKO8q9XZPmRRzTmAfGiNY7eKidnFRh7hU_M0ev3Zh1Pfucfo3qcW7PA</recordid><startdate>2021</startdate><enddate>2021</enddate><creator>Freigang, Viola</creator><creator>Gottsauner, Maximilian</creator><creator>Rupp, Markus</creator><creator>Pfeifer, Christian</creator><creator>Grechenig, Stephan</creator><creator>Kerner, Alexander</creator><creator>Alt, Volker</creator><creator>Baumann, Florian</creator><general>Hindawi</general><general>John Wiley & Sons, Inc</general><general>Hindawi Limited</general><scope>RHU</scope><scope>RHW</scope><scope>RHX</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>3V.</scope><scope>7QL</scope><scope>7QO</scope><scope>7T7</scope><scope>7TK</scope><scope>7U7</scope><scope>7U9</scope><scope>7X7</scope><scope>7XB</scope><scope>88E</scope><scope>8FD</scope><scope>8FE</scope><scope>8FG</scope><scope>8FH</scope><scope>8FI</scope><scope>8FJ</scope><scope>8FK</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>ARAPS</scope><scope>AZQEC</scope><scope>BBNVY</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>BHPHI</scope><scope>C1K</scope><scope>CCPQU</scope><scope>CWDGH</scope><scope>DWQXO</scope><scope>FR3</scope><scope>FYUFA</scope><scope>GHDGH</scope><scope>GNUQQ</scope><scope>H94</scope><scope>HCIFZ</scope><scope>K9.</scope><scope>LK8</scope><scope>M0S</scope><scope>M1P</scope><scope>M7N</scope><scope>M7P</scope><scope>P5Z</scope><scope>P62</scope><scope>P64</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>7X8</scope><scope>5PM</scope><orcidid>https://orcid.org/0000-0003-1413-3587</orcidid></search><sort><creationdate>2021</creationdate><title>Surgical Drill Guide for Insertion of an Infra-Acetabular Screw Based on an Anatomically Precontoured Plate System: A Cadaveric Study</title><author>Freigang, Viola ; Gottsauner, Maximilian ; Rupp, Markus ; Pfeifer, Christian ; Grechenig, Stephan ; Kerner, Alexander ; Alt, Volker ; Baumann, Florian</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c481t-2ca4e373c14c005f6680959b66c0cedd911f15a9c25c0fe25488f94afe8144df3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Acetabulum</topic><topic>Analysis</topic><topic>Bone implants</topic><topic>Buttresses</topic><topic>Cadavers</topic><topic>Cartilage</topic><topic>Computed tomography</topic><topic>Fixation</topic><topic>Fracture fixation</topic><topic>Fractures</topic><topic>Hip joint</topic><topic>Internal fixation in fractures</topic><topic>Management</topic><topic>Methods</topic><topic>Pelvis</topic><topic>Quadrilaterals</topic><topic>Software</topic><topic>Statistical analysis</topic><topic>Surgical techniques</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Freigang, Viola</creatorcontrib><creatorcontrib>Gottsauner, Maximilian</creatorcontrib><creatorcontrib>Rupp, Markus</creatorcontrib><creatorcontrib>Pfeifer, Christian</creatorcontrib><creatorcontrib>Grechenig, Stephan</creatorcontrib><creatorcontrib>Kerner, Alexander</creatorcontrib><creatorcontrib>Alt, Volker</creatorcontrib><creatorcontrib>Baumann, Florian</creatorcontrib><collection>Hindawi Publishing Complete</collection><collection>Hindawi Publishing Subscription Journals</collection><collection>Hindawi Publishing Open Access</collection><collection>CrossRef</collection><collection>ProQuest Central (Corporate)</collection><collection>Bacteriology Abstracts (Microbiology B)</collection><collection>Biotechnology Research Abstracts</collection><collection>Industrial and Applied Microbiology Abstracts (Microbiology A)</collection><collection>Neurosciences Abstracts</collection><collection>Toxicology Abstracts</collection><collection>Virology and AIDS Abstracts</collection><collection>ProQuest Health and Medical</collection><collection>ProQuest Central (purchase pre-March 2016)</collection><collection>Medical Database (Alumni Edition)</collection><collection>Technology Research Database</collection><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Hospital Premium Collection</collection><collection>Hospital Premium Collection (Alumni Edition)</collection><collection>ProQuest Central (Alumni) (purchase pre-March 2016)</collection><collection>ProQuest Central (Alumni)</collection><collection>ProQuest Central</collection><collection>Advanced Technologies & Aerospace Collection</collection><collection>ProQuest Central Essentials</collection><collection>Biological Science Collection</collection><collection>AUTh Library subscriptions: ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest Natural Science Collection</collection><collection>Environmental Sciences and Pollution Management</collection><collection>ProQuest One Community College</collection><collection>Middle East & Africa Database</collection><collection>ProQuest Central</collection><collection>Engineering Research Database</collection><collection>Health Research Premium Collection</collection><collection>Health Research Premium Collection (Alumni)</collection><collection>ProQuest Central Student</collection><collection>AIDS and Cancer Research Abstracts</collection><collection>SciTech Premium Collection (Proquest) (PQ_SDU_P3)</collection><collection>ProQuest Health & Medical Complete (Alumni)</collection><collection>ProQuest Biological Science Collection</collection><collection>Health & Medical Collection (Alumni Edition)</collection><collection>PML(ProQuest Medical Library)</collection><collection>Algology Mycology and Protozoology Abstracts (Microbiology C)</collection><collection>ProQuest Biological Science Journals</collection><collection>ProQuest advanced technologies & aerospace journals</collection><collection>ProQuest Advanced Technologies & Aerospace Collection</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Publicly Available Content Database (Proquest) (PQ_SDU_P3)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>MEDLINE - Academic</collection><collection>PubMed Central (Full Participant titles)</collection><jtitle>BioMed research international</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Freigang, Viola</au><au>Gottsauner, Maximilian</au><au>Rupp, Markus</au><au>Pfeifer, Christian</au><au>Grechenig, Stephan</au><au>Kerner, Alexander</au><au>Alt, Volker</au><au>Baumann, Florian</au><au>Fortina, Mattia</au><au>Mattia Fortina</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Surgical Drill Guide for Insertion of an Infra-Acetabular Screw Based on an Anatomically Precontoured Plate System: A Cadaveric Study</atitle><jtitle>BioMed research international</jtitle><date>2021</date><risdate>2021</risdate><volume>2021</volume><spage>1</spage><epage>7</epage><pages>1-7</pages><issn>2314-6133</issn><eissn>2314-6141</eissn><abstract>Purpose. Due to the anatomic structure of the pelvis, free-hand placement of screws in the acetabular fracture management can be difficult. Infra-acetabular screw fixation increases acetabular stability by distal fixation of the cup. Aim of this cadaveric study is to investigate if a plate-referenced drill guide can provide save placement of an infra-acetabular screw over a precontoured suprapectineal quadrilateral buttress plate (SQBP). Methods. We constructed a drill guide for an infra-acetabular screw based on the surface of an anatomically precontoured SQBP. A total of 12 adult cadaveric acetabular specimens were used for drill guide-assisted placement of the infra-acetabular screw. The drill guide contains a radiopaque spiral to allow longitudinal fine adjustment of the SQBP along the pelvic brim to assure correct position of the plate-drill-guide construct in relation to the Koehler’s teardrop. After screw placement, we conducted a computed tomography (CT) scan of all specimens to assess the actual position of the screw in relation of the infra-acetabular corridor and the acetabular joint surface. Results. The position of the screw was within the infra-acetabular corridor in all cases. We did not see any intra-articular or intrapelvic screw penetration. The mean distance of the centerline of the screw to the medial border of the infra-acetabular corridor was 3.35 mm. The secure distance to the virtual surface of the femoral head to was 7.3 mm. Conclusions. A plate-referenced drill guide can provide safe placement of an infra-acetabular screw for treatment of acetabular fractures. Radiographic fine adjustment is necessary to access the optimal entry point.</abstract><cop>New York</cop><pub>Hindawi</pub><pmid>34355040</pmid><doi>10.1155/2021/2321504</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0003-1413-3587</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2314-6133 |
ispartof | BioMed research international, 2021, Vol.2021, p.1-7 |
issn | 2314-6133 2314-6141 |
language | eng |
recordid | cdi_pubmedcentral_primary_oai_pubmedcentral_nih_gov_8331300 |
source | Publicly Available Content Database (Proquest) (PQ_SDU_P3); Wiley Online Library Open Access |
subjects | Acetabulum Analysis Bone implants Buttresses Cadavers Cartilage Computed tomography Fixation Fracture fixation Fractures Hip joint Internal fixation in fractures Management Methods Pelvis Quadrilaterals Software Statistical analysis Surgical techniques |
title | Surgical Drill Guide for Insertion of an Infra-Acetabular Screw Based on an Anatomically Precontoured Plate System: A Cadaveric Study |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T14%3A13%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_pubme&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Surgical%20Drill%20Guide%20for%20Insertion%20of%20an%20Infra-Acetabular%20Screw%20Based%20on%20an%20Anatomically%20Precontoured%20Plate%20System:%20A%20Cadaveric%20Study&rft.jtitle=BioMed%20research%20international&rft.au=Freigang,%20Viola&rft.date=2021&rft.volume=2021&rft.spage=1&rft.epage=7&rft.pages=1-7&rft.issn=2314-6133&rft.eissn=2314-6141&rft_id=info:doi/10.1155/2021/2321504&rft_dat=%3Cgale_pubme%3EA696876546%3C/gale_pubme%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c481t-2ca4e373c14c005f6680959b66c0cedd911f15a9c25c0fe25488f94afe8144df3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=2559339110&rft_id=info:pmid/34355040&rft_galeid=A696876546&rfr_iscdi=true |